Michael Nagel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Michael Nagel has a total of 154 co-authors. Here are the top co-authors by number of shared publications:
H. Kurz
AMO GmbH, Otto-Blumenthal-Straße 25, 52074 Aachen, Germany
31 shared publicationsHeinrich Kurz
AMO GmbH, Otto-Blumenthal-Straße 25, 52074 Aachen, Germany
17 shared publications- Peter Haring Bolívar
Institute of High Frequency and Quantum Electronics, University of Siegen, Siegen, Germany
9 shared publications M. Awad
Institute of Semiconductor Electronics, RWTH Aachen University Sommerfeldstr. 24, 52074 Aachen, Germany
8 shared publicationsM. Brucherseifer
Institut für Halbleitertechnik, RWTH Aachen, Sommerfeldstr. 24, D-52056 Aachen, Germany
7 shared publications- Simon Sawallich
Protemics GmbH, Aachen, Germany
7 shared publications
Latest Publications
- Open Access
- 12 March 2026
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 26 (11) , 3823-3829
On-Chip THz-TDS Platform for High-Sensitivity Analysis of Graphene and Thin-Film Conductors
Terahertz (THz) technology enables nondestructive characterization of conductive thin films but faces challenges in analyzing ultrathin, weakly conductive two-dimensional materials because of their weak light-matter interactions. On-chip spectroscopy (OCS) using planar waveguides addresses this limitation by confining THz fields, thereby enhancing electromagnetic coupling to samples. However, most OCS devices are firmly integrated with samples, limiting their reusability. Here, we developed a compact, high-sensitivity on-chip THz sensor featuring a symmetric coplanar stripline embedded in low-permittivity polymer films. Its modular design, comprising a rigid motherboard and a detachable daughterboard for sample mounting, enabled multisample testing with a single device. Air-gap-dependent measurements confirmed effective field coupling. Our THz OCS platform demonstrated absorption enhancements exceeding 8.8 dB for graphene and 21.6 dB for chromium with distinct phase shifts and pulse broadening compared to conventional free-space systems. The exchangeable daughterboard allows tunable and reproducible sample interactions for highly sensitive characterization of ultrathin films.
- 12 March 2026
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 26 (11) , 3823-3829
Open AccessOn-Chip THz-TDS Platform for High-Sensitivity Analysis of Graphene and Thin-Film Conductors
Terahertz (THz) technology enables nondestructive characterization of conductive thin films but faces challenges in analyzing ultrathin, weakly conductive two-dimensional materials because of their weak light-matter interactions. On-chip spectroscopy (OCS) using planar waveguides addresses this limitation by confining THz fields, thereby enhancing electromagnetic coupling to samples. However, most OCS devices are firmly integrated with samples, limiting their reusability. Here, we developed a compact, high-sensitivity on-chip THz sensor featuring a symmetric coplanar stripline embedded in low-permittivity polymer films. Its modular design, comprising a rigid motherboard and a detachable daughterboard for sample mounting, enabled multisample testing with a single device. Air-gap-dependent measurements confirmed effective field coupling. Our THz OCS platform demonstrated absorption enhancements exceeding 8.8 dB for graphene and 21.6 dB for chromium with distinct phase shifts and pulse broadening compared to conventional free-space systems. The exchangeable daughterboard allows tunable and reproducible sample interactions for highly sensitive characterization of ultrathin films.
- Open Access
- 24 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 20648-20657
Near-Field Semiconductor Imaging and Classification Enabled by Signal Cancellation Using Truncated mm-Wave Silicon Waveguide
We demonstrate that a straightforward truncated silicon dielectric waveguide serves as an effective millimeter-wave (mm-wave) near-field semiconductor imaging sensor. The strong localization of modal fields at the truncated silicon tip interface results in fine resolution below the diffraction limit. It is found that, at a specific probing distance, high conductance of a metallized sample exhibits lower reflection than bare silicon substrate due to the signal cancellation with the reflection generated from the significant mismatch at the truncated interface. We experimentally validate that this cancellation effect is dependent upon conductivity and it allows us to differentiate multiple levels of conductivity. With this technique, we achieve the resolution of ~1/3 λ0 and a high image contrast of ~20 dB between conductors and the bare silicon substrate. In addition, a cancellation effect is employed that allows for accurate calibration of working distance, providing stable responses across the scanning area. We demonstrate how this effect can be exploited for high-accuracy material classification with broadband spectral correlation analysis enabled by the silicon sensor. The proposed method can be easily incorporated with integrated all-silicon circuits, showing promise for cost-effective, compact imaging modules, which is highly beneficial for real-world deployment in the industry.
- 24 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 20648-20657
Open AccessNear-Field Semiconductor Imaging and Classification Enabled by Signal Cancellation Using Truncated mm-Wave Silicon Waveguide
We demonstrate that a straightforward truncated silicon dielectric waveguide serves as an effective millimeter-wave (mm-wave) near-field semiconductor imaging sensor. The strong localization of modal fields at the truncated silicon tip interface results in fine resolution below the diffraction limit. It is found that, at a specific probing distance, high conductance of a metallized sample exhibits lower reflection than bare silicon substrate due to the signal cancellation with the reflection generated from the significant mismatch at the truncated interface. We experimentally validate that this cancellation effect is dependent upon conductivity and it allows us to differentiate multiple levels of conductivity. With this technique, we achieve the resolution of ~1/3 λ0 and a high image contrast of ~20 dB between conductors and the bare silicon substrate. In addition, a cancellation effect is employed that allows for accurate calibration of working distance, providing stable responses across the scanning area. We demonstrate how this effect can be exploited for high-accuracy material classification with broadband spectral correlation analysis enabled by the silicon sensor. The proposed method can be easily incorporated with integrated all-silicon circuits, showing promise for cost-effective, compact imaging modules, which is highly beneficial for real-world deployment in the industry.
- 23 November 2024
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 667, 124996
Sparse-deconvolution terahertz near-field microprobe tomography enabling non-destructive inspection of small solid dosage forms
- 23 November 2024
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 667, 124996
Sparse-deconvolution terahertz near-field microprobe tomography enabling non-destructive inspection of small solid dosage forms
- 5 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (16) , 9521-9532
Graphene and Silver Nanoparticle-Coated Poly(vinyl) Alcohol/Graphene Oxide/Dioctyl Terephthalate: Bis(2-hydroxyethyl) Terephthalate Composite Strain Sensors
- 5 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 6 (16) , 9521-9532
Graphene and Silver Nanoparticle-Coated Poly(vinyl) Alcohol/Graphene Oxide/Dioctyl Terephthalate: Bis(2-hydroxyethyl) Terephthalate Composite Strain Sensors
- 17 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Photoconductive THz near-field detectors operated with a 1550 nm cw-laser system for high spatial- and spectral-resolution measurements
We combine terahertz (THz) near-field detectors with a continuous-wave frequency-domain THz-system operating at 1550 nm. This configuration enables high spatial-resolution nearfield imaging in conjugation with a high spectral-resolution and more than 1.3 THz bandwidth.
- 17 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Photoconductive THz near-field detectors operated with a 1550 nm cw-laser system for high spatial- and spectral-resolution measurements
We combine terahertz (THz) near-field detectors with a continuous-wave frequency-domain THz-system operating at 1550 nm. This configuration enables high spatial-resolution nearfield imaging in conjugation with a high spectral-resolution and more than 1.3 THz bandwidth.
- 1 May 2023
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 23 (9) , 3835-3841
On-Chip Time-Domain Terahertz Spectroscopy of Superconducting Films below the Diffraction Limit
Free-space time domain THz spectroscopy accesses electrodynamic responses in a frequency regime ideally matched to interacting condensed matter systems. However, THz spectroscopy is challenging when samples are physically smaller than the diffraction limit of ∼0.5 mm, as is typical, for example, in van der Waals materials and heterostructures. Here, we present an on-chip, time-domain THz spectrometer based on semiconducting photoconductive switches with a bandwidth of 200 to 750 GHz. We measure the optical conductivity of a 7.5-μm wide NbN film across the superconducting transition, demonstrating spectroscopic signatures of the superconducting gap in a sample smaller than 2% of the Rayleigh diffraction limit. Our spectrometer features an interchangeable sample architecture, making it ideal for probing superconductivity, magnetism, and charge order in strongly correlated van der Waals materials.
- 1 May 2023
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 23 (9) , 3835-3841
On-Chip Time-Domain Terahertz Spectroscopy of Superconducting Films below the Diffraction Limit
Free-space time domain THz spectroscopy accesses electrodynamic responses in a frequency regime ideally matched to interacting condensed matter systems. However, THz spectroscopy is challenging when samples are physically smaller than the diffraction limit of ∼0.5 mm, as is typical, for example, in van der Waals materials and heterostructures. Here, we present an on-chip, time-domain THz spectrometer based on semiconducting photoconductive switches with a bandwidth of 200 to 750 GHz. We measure the optical conductivity of a 7.5-μm wide NbN film across the superconducting transition, demonstrating spectroscopic signatures of the superconducting gap in a sample smaller than 2% of the Rayleigh diffraction limit. Our spectrometer features an interchangeable sample architecture, making it ideal for probing superconductivity, magnetism, and charge order in strongly correlated van der Waals materials.
- Open Access
- 29 January 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (8)
Assessment of Wafer‐Level Transfer Techniques of Graphene with Respect to Semiconductor Industry Requirements
Graphene is a promising candidate for future electronic applications. Manufacturing graphene‐based electronic devices typically requires graphene transfer from its growth substrate to another desired substrate. This key step for device integration must be applicable at the wafer level and meet the stringent requirements of semiconductor fabrication lines. In this work, wet and semidry transfer (i.e. wafer bonding) are evaluated regarding wafer scalability, handling, potential for automation, yield, contamination, and electrical performance. A wafer scale tool is developed to transfer graphene from 150 mm copper foils to 200 mm silicon wafers without adhesive intermediate polymers. The transferred graphene coverage ranges from 97.9 % to 99.2 % for wet transfer and from 17.2 % to 90.8 % for semidry transfer, with average copper contaminations of 4.7 × 1013 (wet) and 8.2 × 1012 atoms/cm2 (semidry). The corresponding electrical sheet resistance extracted from terahertz time‐domain spectroscopy varied from 450 to 550 Ω sq−1 for wet transfer and from 1000 to 1650 Ω sq−1 for semidry transfer. Although the wet transfer is superior in terms of yield, carbon contamination level, and electrical quality, wafer bonding yields lower copper contamination levels and provides scalability due to existing industrial tools and processes. Our conclusions can be generalized to all 2D materials.
- 29 January 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (8)
Open AccessAssessment of Wafer‐Level Transfer Techniques of Graphene with Respect to Semiconductor Industry Requirements
Graphene is a promising candidate for future electronic applications. Manufacturing graphene‐based electronic devices typically requires graphene transfer from its growth substrate to another desired substrate. This key step for device integration must be applicable at the wafer level and meet the stringent requirements of semiconductor fabrication lines. In this work, wet and semidry transfer (i.e. wafer bonding) are evaluated regarding wafer scalability, handling, potential for automation, yield, contamination, and electrical performance. A wafer scale tool is developed to transfer graphene from 150 mm copper foils to 200 mm silicon wafers without adhesive intermediate polymers. The transferred graphene coverage ranges from 97.9 % to 99.2 % for wet transfer and from 17.2 % to 90.8 % for semidry transfer, with average copper contaminations of 4.7 × 1013 (wet) and 8.2 × 1012 atoms/cm2 (semidry). The corresponding electrical sheet resistance extracted from terahertz time‐domain spectroscopy varied from 450 to 550 Ω sq−1 for wet transfer and from 1000 to 1650 Ω sq−1 for semidry transfer. Although the wet transfer is superior in terms of yield, carbon contamination level, and electrical quality, wafer bonding yields lower copper contamination levels and provides scalability due to existing industrial tools and processes. Our conclusions can be generalized to all 2D materials.
- 8 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
A 1550-nm-wavelength compatible photoconductive microprobe transceiver for Terahertz near-field reflection measurements
THz-radiation based measurements in reflection-mode provide several advantages over transmission-mode configurations such as depth information and single side sample access useful e.g. for the inspection of multi-layer structures, detection of buried defects or the investigation of samples on THz opaque substrates. We present here an InGaAs:Rh-based photoconductive near-field transceiver probe operating at 1550 nm excitation wavelength which can be directly driven by modern fiber-based THz TDS systems without requiring optical frequency-doubling units. The new probe will foster the configuration of fiber-based robotic scanning systems thanks to the simplification of the optical front-end module.
- 8 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
A 1550-nm-wavelength compatible photoconductive microprobe transceiver for Terahertz near-field reflection measurements
THz-radiation based measurements in reflection-mode provide several advantages over transmission-mode configurations such as depth information and single side sample access useful e.g. for the inspection of multi-layer structures, detection of buried defects or the investigation of samples on THz opaque substrates. We present here an InGaAs:Rh-based photoconductive near-field transceiver probe operating at 1550 nm excitation wavelength which can be directly driven by modern fiber-based THz TDS systems without requiring optical frequency-doubling units. The new probe will foster the configuration of fiber-based robotic scanning systems thanks to the simplification of the optical front-end module.
- Open Access
- 21 January 2016
- Published by American Physical Society (APS) in Physical Review B
- Vol. 93 (3) , 035438
Large near-to-far field spectral shifts for terahertz resonances
We have performed far-field extinction measurements and near electric field measurements on gold bowtie antennas resonant at THz frequencies. These measurements show a very large shift between the resonant frequencies of the near-field and the far-field spectra. We use the established damped-driven harmonic oscillator model for resonators to model the far-field response of the antennas from the near-field spectrum and show that there is a large discrepancy between the predicted and measured far-field response. We were able to explain this discrepancy by improving the oscillator model with a Fano model. This large shift makes the prediction of the near-field response of resonant structures at THz frequencies very imprecise, provided that only information of the far-field response is available and establishes the necessity of measuring near fields for a correct and accurate characterization of these structures.
- 21 January 2016
- Published by American Physical Society (APS) in Physical Review B
- Vol. 93 (3) , 035438
Open AccessLarge near-to-far field spectral shifts for terahertz resonances
We have performed far-field extinction measurements and near electric field measurements on gold bowtie antennas resonant at THz frequencies. These measurements show a very large shift between the resonant frequencies of the near-field and the far-field spectra. We use the established damped-driven harmonic oscillator model for resonators to model the far-field response of the antennas from the near-field spectrum and show that there is a large discrepancy between the predicted and measured far-field response. We were able to explain this discrepancy by improving the oscillator model with a Fano model. This large shift makes the prediction of the near-field response of resonant structures at THz frequencies very imprecise, provided that only information of the far-field response is available and establishes the necessity of measuring near fields for a correct and accurate characterization of these structures.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21622027,p. 1-2
Active Terahertz near-field probes for high-resolution free-carrier density imaging applications
First photo-conductive near-field probes combining THz generation, detection, transmission and resonant focusing element in a single micro-structured cantilever device are presented and applied to free-carrier density imaging applications in semiconductor (solar) material analytics.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21622027,p. 1-2
Active Terahertz near-field probes for high-resolution free-carrier density imaging applications
First photo-conductive near-field probes combining THz generation, detection, transmission and resonant focusing element in a single micro-structured cantilever device are presented and applied to free-carrier density imaging applications in semiconductor (solar) material analytics.