Will Cousins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Will Cousins has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Pierre A. Gremaud
Department of Mathematics North Carolina State University Raleigh, NC 27695 USA
2 shared publications- Themistoklis P. Sapsis
Massachusetts Institute of Technology
2 shared publications Daniel M. Tartakovsky
1 shared publication- Pierre A. Gremaud
Department of Mathematics North Carolina State University Raleigh NC USA
1 shared publication
Latest Publications
- 27 November 2015
- Published by Springer Nature
- p. 134-143
Reduced Order Probabilistic Prediction of Rogue Waves in One-Dimensional Envelope Equations
- 27 November 2015
- Published by Springer Nature
- p. 134-143
Reduced Order Probabilistic Prediction of Rogue Waves in One-Dimensional Envelope Equations
- Open Access
- 1 July 2014
- Published by Elsevier in Physica D: Nonlinear Phenomena
- Vol. 280-281, 48-58
Quantification and prediction of extreme events in a one-dimensional nonlinear dispersive wave model
- 1 July 2014
- Published by Elsevier in Physica D: Nonlinear Phenomena
- Vol. 280-281, 48-58
Open AccessQuantification and prediction of extreme events in a one-dimensional nonlinear dispersive wave model
- 23 June 2014
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 30 (11) , 1294-1313
Impedance boundary conditions for general transient hemodynamics
SUMMARY: We discuss the implementation and calibration of a new generalized structured tree boundary condition for hemodynamics. The main idea is to approximate the impedance corresponding to the vessels downstream from a specific outlet. Unlike previous impedance conditions, the one considered here is applicable to general transient flows as opposed to periodic ones only. The physiological character of the approach significantly simplifies calibration. We also describe a novel way to incorporate autoregulation mechanisms in structured arterial trees at minimal computational cost. The strength of the approach is illustrated and validated on several examples through comparison with clinical data. Copyright © 2014 John Wiley & Sons, Ltd.
- 23 June 2014
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 30 (11) , 1294-1313
Impedance boundary conditions for general transient hemodynamics
SUMMARY: We discuss the implementation and calibration of a new generalized structured tree boundary condition for hemodynamics. The main idea is to approximate the impedance corresponding to the vessels downstream from a specific outlet. Unlike previous impedance conditions, the one considered here is applicable to general transient flows as opposed to periodic ones only. The physiological character of the approach significantly simplifies calibration. We also describe a novel way to incorporate autoregulation mechanisms in structured arterial trees at minimal computational cost. The strength of the approach is illustrated and validated on several examples through comparison with clinical data. Copyright © 2014 John Wiley & Sons, Ltd.
- 1 January 2013
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Applied Mathematics
- Vol. 73 (3) , 1203-1223
A New Physiological Boundary Condition for Hemodynamics
We propose a new physiologically-based outflow boundary condition for hemodynamics under general transient regimes. This is in contrast to previous studies that impose restrictions of temporal periodicity. The new condition is analyzed and its numerical implementation is discussed in detail. We show that existing impedance boundary conditions can be viewed as numerical approximations of the new condition. Our study provides a partial justification for using some of these existing conditions beyond the periodic problems for which they were designed. Moreover, the new condition has better stability properties. The theoretical results are illustrated by numerical experiments pertaining to cerebral blood flow.
- 1 January 2013
- Published by Society for Industrial & Applied Mathematics (SIAM) in SIAM Journal on Applied Mathematics
- Vol. 73 (3) , 1203-1223
A New Physiological Boundary Condition for Hemodynamics
We propose a new physiologically-based outflow boundary condition for hemodynamics under general transient regimes. This is in contrast to previous studies that impose restrictions of temporal periodicity. The new condition is analyzed and its numerical implementation is discussed in detail. We show that existing impedance boundary conditions can be viewed as numerical approximations of the new condition. Our study provides a partial justification for using some of these existing conditions beyond the periodic problems for which they were designed. Moreover, the new condition has better stability properties. The theoretical results are illustrated by numerical experiments pertaining to cerebral blood flow.
- 1 July 2012
- Published by Elsevier in Journal of Computational Physics
- Vol. 231 (18) , 6086-6096
Boundary conditions for hemodynamics: The structured tree revisited
- 1 July 2012
- Published by Elsevier in Journal of Computational Physics
- Vol. 231 (18) , 6086-6096
Boundary conditions for hemodynamics: The structured tree revisited