EGEliza L. Gross

Eliza L. Gross

*This is an algorithmically generated author record based on publicly available information.

Eliza L. Gross has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Compilation and evaluation of data used to identify groundwater sources under the direct influence of surface water in Pennsylvania

    by Eliza L. Gross, Matthew D. Conlon, Dennis W. Risser, Chad E. Reisch

    A study was conducted to compile and evaluate data used to identify groundwater sources that are under the direct influence of surface water (GUDI) in Pennsylvania. In the early 1990s, the Pennsylvania Department of Environmental Protection (PADEP) implemented the Surface Water Identification Protocol (SWIP) for the identification of GUDI sources. Since the establishment of the SWIP, PADEP has classified more than 500 individual sources across Pennsylvania as GUDI, but Pennsylvania’s complex geology and physiography provide a challenge for a uniform method of GUDI determination. Components used in this study to compile and evaluate data associated with GUDI determination include a preliminary review of file information for 43 public water-supply wells, quality control and addition of data to PADEP’s database for public water-supply systems to prepare data for analysis, and exploratory evaluation of existing GUDI sources in the database with respect to hydrogeologic and source-construction characteristics that are currently utilized in the assessment methodology.Case files for 43 wells from PADEP’s Northcentral and Southcentral regions were reviewed to (1) provide a better understanding of how the SWIP was applied in practice, (2) verify and compile missing data, and (3) find additional attributes not previously available that might explain a well’s categorization as GUDI. Review of file information showed that the SWIP outlined in PADEP technical guidance was usually followed, but for some sources, the GUDI determination was more complex and could not be easily summarized.Data compiled for study analyses provided by PADEP include source data derived from public water-supply system case files, a source-information database for public water-supply systems, and Microscopic Particulate Analysis (MPA) results and associated water-quality data for public water-supply system groundwater sources. Data from the Pennsylvania Drinking Water Information System (PADWIS), which is PADEP’s database for public water-supply systems, were also used for this study. A subset (4,018 wells consisting of 3,842 non-GUDI wells and 175 GUDI wells) of the PADWIS database, which originally included data for 12,147 groundwater sources (11,812 non-GUDI wells and 335 GUDI wells), was created for an analysis and includes only community wells evaluated in accordance with the SWIP. MPA results for 631 community and noncommunity wells were compiled, along with associated water-quality data (alkalinity, chloride, Escherichia coli, fecal coliform, nitrate, pH, sodium, specific conductance, sulfate, total coliform, total dissolved solids, total residue, and turbidity) populated from the PADEP Bureau of Laboratories Sample Information System. Data compiled from sources other than PADEP include spatial data, both naturogenic (for example, average precipitation or distance to closest hydrologic feature) and anthropogenic (for example, percentage of developed or agricultural land cover within a specific vicinity of a public water-supply system well) data representing spatially derived variables.Comparison among wells in the PADWIS dataset subset using the nonparametric Kruskal-Wallis test showed that GUDI wells had significantly older median construction years, shallower depths, and static water levels closer to the land surface than non-GUDI wells and that carbonate aquifers had the highest percentages of wells designated as GUDI (12 percent; 57 wells). Further comparison of wells in the PADWIS database subset using the Spearman’s rho monotonic correlation test illustrated that public water-supply wells designated as GUDI largely occur in unconfined aquifers and have high average yield and shallow static water levels. Assessment of the MPA database subset using the Kruskal-Wallis test showed wells with MPA total risk factor scores that exceeded zero had older median construction years and shallower casing depths than wells with MPA total risk factor scores of zero and that carbonate aquifers had the highest percentages of wells with MPA total risk factor scores exceeding zero (30 percent; 63 wells). Spearman’s rho correlations showed that wells completed in aquifers with depths to major water-bearing zones closer to the land-surface had higher total risk factor scores resulting from MPA samples.On the basis of the results of the analyses described in this report, broad conclusions can be drawn regarding site-specific well characteristics and anthropogenic and naturogenic factors that could be responsible for a well being designated as GUDI, but the accuracy of these results is dependent on the quality of the data being analyzed. Ultimately, study results serve as an added resource for initial desktop screening of wells to determine if additional site-specific investigation is warranted and underscore the need for field evaluation.

  • Open Access

    Arsenic and uranium occurrence in private wells in Connecticut, 2013–18—A spatially weighted and bedrock geology assessment

    by Eliza L. Gross, Craig J. Brown

    The U.S. Geological Survey, in cooperation with the Connecticut Department of Public Health, conducted a study to determine the presence of arsenic and uranium in private drinking water wells in Connecticut. Samples were collected during 2013–18 from wells completed in 115 geologic units, with 2,433 samples analyzed for arsenic and 2,191 samples analyzed for uranium. The study concluded four major findings.In a spatially weighted analysis of groundwater samples collected from more than 2,000 private wells in bedrock aquifers in Connecticut, 3.9 percent of collected samples contained arsenic concentrations greater than the U.S. Environmental Protection Agency’s (EPA) maximum contaminant level (MCL) of 10 micrograms per liter (µg/L), and 4.7 percent of collected samples contained uranium concentrations greater than the EPA MCL of 30 µg/L.Of the 2,433 water samples collected and analyzed from bedrock aquifers in Connecticut, 4.2 percent (102) contained arsenic concentrations at greater than 10 µg/L, and of the 2,191 water samples collected and analyzed from bedrock aquifers in Connecticut, 5.4 percent (118) contained uranium concentrations greater than 30 µg/L.Uranium concentrations greater than or equal to 1 µg/L are relatively ubiquitous across the State of Connecticut, with these concentrations present in 44.9 percent of the State, according to spatially weighted statewide-scale proportion analysis.Of the 115 geologic units studied, 44 had at least one sample with arsenic or uranium concentrations that exceeded the respective constituent’s EPA MCL.


  • Open Access

    Evaluation of radon occurrence in groundwater from 16 geologic units in Pennsylvania, 1986–2015, with application to potential radon exposure from groundwater and indoor air

    by Eliza L. Gross

    Results from 1,041 groundwater samples collected during 1986‒2015 from 16 geologic units in Pennsylvania, associated with 25 or more groundwater samples with concentrations of radon-222, were evaluated in an effort to identify variations in radon-222 activities or concentrations and to classify potential radon-222 exposure from groundwater and indoor air. Radon-222 is hereafter referred to as “radon.” Radon concentrations in groundwater greater than or equal to the proposed U.S. Environmental Protection Agency (EPA) maximum contaminant level (MCL) for public-water supply systems of 300 picocuries per liter (pCi/L) were present in about 87 percent of the water samples, whereas concentrations greater than or equal to the proposed alternative MCL (AMCL) for public water-supply systems of 4,000 pCi/L were present in 14 percent. The highest radon concentrations were measured in groundwater from the schists, gneisses, and quartzites of the Piedmont Physiographic Province.In this study, conducted by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Health and the Pennsylvania Department of Environmental Protection, groundwater samples were aggregated among 16 geologic units in Pennsylvania to identify units with high median radon concentrations in groundwater. Graphical plots and statistical tests were used to determine variations in radon concentrations in groundwater and indoor air. Median radon concentrations in groundwater samples and median radon concentrations in indoor air samples within the 16 geologic units were classified according to proposed and recommended regulatory limits to explore potential radon exposure from groundwater and indoor air. All of the geologic units, except for the Allegheny (Pa) and Glenshaw (Pcg) Formations in the Appalachian Plateaus Physiographic Province, had median radon concentrations greater than the proposed EPA MCL of 300 pCi/L, and the Peters Creek Schist (Xpc), which is in the Piedmont Physiographic Province, had a median radon concentration greater than the EPA proposed AMCL of 4,000 pCi/L. Median concentrations of radon in groundwater and indoor air were determined to differ significantly among the geologic units (Kruskal-Wallis test, significance probability, p<0.001), and Tukey’s test indicated that radon concentrations in groundwater and indoor air in the Peters Creek Schist (Xpc) were significantly higher than those in the other units. Also, the Peters Creek Schist (Xpc) was determined to be the area with highest potential of radon exposure from groundwater and indoor air and one of two units with the highest percentage of population assumed to be using domestic self-supplied water (81 percent), which puts the population at greater potential of exposure to radon from groundwater.Potential radon exposure determined from classification of geologic units by median radon concentrations in groundwater and indoor air according to proposed and recommended regulatory limits is useful for drawing general conclusions about the presence, variation, and potential radon exposure in specific geologic units, but the associated data and maps have limitations. The aggregated indoor air radon data have spatial accuracy limitations owing to imprecision of geocoded test locations. In addition, the associated data describing geologic units and the public water supplier’s service areas have spatial and interpretation accuracy limitations. As a result, data and maps associated with this report are not recommended for use in predicting individual concentrations at specific sites nor for use as a decision-making tool for property owners to decide whether to test for radon concentrations at specific locations. Instead, the data and maps are meant to promote awareness regarding potential radon exposure in Pennsylvania and to point out data gaps that exist throughout the State.


  • Groundwater quality for 75 domestic wells in Lycoming County, Pennsylvania, 2014

    by Eliza L. Gross, Charles A. Cravotta

    Groundwater is a major source of drinking water in Lycoming County and adjacent counties in north-central and northeastern Pennsylvania, which are largely forested and rural and are currently undergoing development for hydrocarbon gases. Water-quality data are needed for assessing the natural characteristics of the groundwater resource and the potential effects from energy and mineral extraction, timber harvesting, agriculture, sewage and septic systems, and other human influences.This report, prepared in cooperation with Lycoming County, presents analytical data for groundwater samples from 75 domestic wells sampled throughout Lycoming County in June, July, and August 2014. The samples were collected using existing pumps and plumbing prior to any treatment and analyzed for physical and chemical characteristics, including nutrients, major ions, metals and trace elements, volatile organic compounds, gross-alpha particle and gross beta-particle activity, uranium, and dissolved gases, including methane and radon-222.Results indicate groundwater quality generally met most drinking-water standards, but that some samples exceeded primary or secondary maximum contaminant levels (MCLs) for arsenic, iron, manganese, total dissolved solids (TDS), chloride, pH, bacteria, or radon-222. Arsenic concentrations were higher than the MCL of 10 micrograms per liter (µg/L) in 9 of the 75 (12 percent) well-water samples, with concentrations as high as 23.6 μg/L; arsenic concentrations were higher than the health advisory level (HAL) of 2 μg/L in 23 samples (31 percent). Total iron concentrations exceeded the secondary maximum contaminant level (SMCL) of 300 μg/L in 20 of the 75 samples. Total manganese concentrations exceeded the SMCL of 50 μg/L in 20 samples and the HAL of 300 μg/L in 2 of those samples. Three samples had chloride concentrations that exceeded the SMCL of 250 milligrams per liter (mg/L); two of those samples exceeded the SMCL of 500 mg/L for TDS. The pH ranged from 5.3 to 9.15 and did not meet the SMCL range of 6.5 to 8.5 in 22 samples, with 17 samples having a pH less than 6.5 and 8 samples having pH greater than 8.5. Generally, the samples that had elevated TDS, chloride, or arsenic concentrations had high pH.Total coliform bacteria were detected in 39 of 75 samples (52 percent), with Escherichia coli detected in 10 of those 39 samples. Radon-222 activities ranged from non-detect to 7,420 picocuries per liter (pCi/L), with a median of 863 pCi/L, and exceeded the proposed drinking-water standard of 300 pCi/L in 50 (67 percent) of the 75 samples; radon-222 activities were higher than the alternative proposed standard of 4,000 pCi/L in 3 samples.Water from 15 of 75 (20 percent) wells had concentrations of methane greater than the reporting level of 0.01 mg/L; detectable methane concentrations ranged from 0.04 to 16.8 mg/L. Two samples had methane concentrations (13.1 and 16.8 mg/L) exceeding the action level of 7 mg/L. Low levels of ethane (up to 0.12 mg/L) were present in the five samples with the highest methane concentrations (near or above 1 mg/L) that were analyzed for hydrocarbon compounds and isotopic composition. The isotopic composition of methane in four of these groundwater samples, from the Catskill and Lock Haven Formations and the Hamilton Group, have sample carbon isotopic ratio delta values (carbon-13/carbon-12) ranging from –42.36 to –36.08 parts per thousand (‰) and hydrogen isotopic ratio delta values (deuterium/protium) ranging from –212.0 to –188.4 ‰, which are consistent with the isotopic compositions reported for mud-gas logging samples from these geologic units and a thermogenic source of the methane. However, the isotopic composition and ratios of methane to ethane in a fifth sample indicate the methane in that sample may be of microbial origin that subsequently underwent oxidation. The fifth sample had the highest concentration of methane, 16.8 mg/L, with an carbon isotopic ratio delta values of -50.59 ‰ and a hydrogen isotopic ratio delta values of -209.7 ‰.The six well-water samples with the highest methane concentrations also had among the highest pH values (8.25 to 9.15) and elevated concentrations of sodium, lithium, boron, fluoride, arsenic, and bromide. Relatively elevated concentrations of some other constituents, such as barium, strontium, and chloride, commonly were present in, but not limited to, those well-water samples with elevated methane.Three of the six groundwater samples with the highest methane concentrations had chloride/bromide ratios that indicate mixing with a small amount of brine (0.02 percent or less) similar in composition to those reported at undetermined depth below the freshwater aquifer and for gas and oil well brines in Pennsylvania. The sample with the highest methane concentration and most other samples with low methane concentrations (less than about 1 mg/L) have chloride/bromide ratios that indicate predominantly anthropogenic sources of chloride, such as road-deicing salt, septic systems, and (or) animal waste. Brines that are naturally present may originate from deeper parts of the aquifer system, while anthropogenic sources are more likely to affect shallow groundwater because they occur on or near the land-surface.The spatial distribution of groundwater compositions generally indicate that (1) uplands along the western border of Lycoming County usually have dilute, slightly acidic oxygenated, calcium-bicarbonate type waters; (2) intermediate altitudes or areas of carbonate bedrock usually have water of near neutral pH, with highest amounts of hardness (calcium and magnesium); (3) stream valleys, low elevations where groundwater may be discharging, and deep wells in uplands usually have water with pH values greater than 8 and highest arsenic, sodium, lithium, bromide concentrations. Geochemical modeling indicated that for samples with elevated...