Essam Elgendy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Essam Elgendy has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
M Fatouh
Mechanical Power Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt
3 shared publications- Khairy Elsayed
Vrije Universiteit Brussel
2 shared publications A Mostafa
1 shared publicationAhmed Mostafa
Mechanical Power Engineering Department, Faculty of Engineering at El-Mattaria, Helwan University, Cairo, Egypt
1 shared publicationAmin Hassan Amin
Department of Mechanical Power Engineering, Faculty of Engineering at El-Mattaria, Helwan University, Cairo, Egypt
1 shared publicationIbrahim Elbadawy
Department of Mechanical Power Engineering, Faculty of Engineering at El-Mattaria, Helwan University, Cairo, Egypt
1 shared publication
Latest Publications
- 17 June 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 145, 1187-1209
Performance analysis of a sustainable green ammonia production system driven by a solar spectrum-beam-splitting technology
- 17 June 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 145, 1187-1209
Performance analysis of a sustainable green ammonia production system driven by a solar spectrum-beam-splitting technology
- Open Access
- 6 July 2024
- Published by Springer Nature in Journal of Engineering and Applied Science
- Vol. 71 (1) , 1-19
Hybrid air conditioning and seawater desalination system assisted by solar energy: thermoeconomic investigation and optimization
The demand for freshwater has become progressively critical due to population growth and water scarcity. The current work investigates the energetic performance of a hybrid absorption refrigeration and desalination system. A parametric study for the system operating conditions has been performed to get the optimal conditions. Also, economic analysis and a multi-objective optimization method are used with the aim of maximizing the energy utilization factor of the system and minimizing total costs. The specific cost of desalinated water from the multi-objective optimization is calculated as (1.728 Cent/L) with the greatest energy utilization factor of (2.214). It turns out that, the system performs optimum at condensation and generation temperatures of 30 and 65 °C respectively, with resultant COP and GOR of 0.84 and 1.37. Using the optimum conditions, TRNSYS has been used to investigate the transient performance of the system for Marsa–Matrouh City in Egypt. The cooling and freshwater demands are 10 kW and 24 L/h. It was concluded that the input energy required to run the hybrid system decreased by about 65% less than that required for separate systems. With the assistance of solar energy, it became clear that the energy required was 60% less than the hybrid system as well.
- 6 July 2024
- Published by Springer Nature in Journal of Engineering and Applied Science
- Vol. 71 (1) , 1-19
Open AccessHybrid air conditioning and seawater desalination system assisted by solar energy: thermoeconomic investigation and optimization
The demand for freshwater has become progressively critical due to population growth and water scarcity. The current work investigates the energetic performance of a hybrid absorption refrigeration and desalination system. A parametric study for the system operating conditions has been performed to get the optimal conditions. Also, economic analysis and a multi-objective optimization method are used with the aim of maximizing the energy utilization factor of the system and minimizing total costs. The specific cost of desalinated water from the multi-objective optimization is calculated as (1.728 Cent/L) with the greatest energy utilization factor of (2.214). It turns out that, the system performs optimum at condensation and generation temperatures of 30 and 65 °C respectively, with resultant COP and GOR of 0.84 and 1.37. Using the optimum conditions, TRNSYS has been used to investigate the transient performance of the system for Marsa–Matrouh City in Egypt. The cooling and freshwater demands are 10 kW and 24 L/h. It was concluded that the input energy required to run the hybrid system decreased by about 65% less than that required for separate systems. With the assistance of solar energy, it became clear that the energy required was 60% less than the hybrid system as well.
- Open Access
- 1 January 2023
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 13 (V32i3) , 1342-1350
Performance Appraisal of Photovoltaic Module Combined with Various Optical Filters: Experimental Investigation
The recent intensified structure of photovoltaic systems globally is a motivation to give a considerable attention for further efficiency improvement. The significant increase in surface temperature resulting from solar radiation is a major factor to the reduction in PV module power output. Currently, just ten to fifty five percent of the solar incident spectrum that hits a PV panel's surface today is converted to electrical power; the remainder is lost as heat. The thermal energy cumulation on the photovoltaic modules considerably reduces the electricity conversion efficiency. In the current study, five optical filters utilizing various working fluids are paired with a photovoltaic module and experimentally compared to the stand-alone photovoltaic module aiming to enhance its output and efficiency. In the current evaluation, the Monte Carlo technique is used to examine and compare the performance of the suggested optical filters. Glycerin, ethyl alcohol, oil, air, and water are the working fluids for the suggested configurations. The Monte-Carlo method indicates that the optical filter employing water has the maximum efficiency among the proposed working fluids. The consequences reveal that the electrical efficiency of the setup using water as a working fluid is the greatest, followed by structures using glycerin, oil, ethyl alcohol, air, and standalone PV modules, which have values of 7.74, 7.59, 7.51, 7.38, 7.19 and 5.17%, respectively.
- 1 January 2023
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 13 (V32i3) , 1342-1350
Open AccessPerformance Appraisal of Photovoltaic Module Combined with Various Optical Filters: Experimental Investigation
The recent intensified structure of photovoltaic systems globally is a motivation to give a considerable attention for further efficiency improvement. The significant increase in surface temperature resulting from solar radiation is a major factor to the reduction in PV module power output. Currently, just ten to fifty five percent of the solar incident spectrum that hits a PV panel's surface today is converted to electrical power; the remainder is lost as heat. The thermal energy cumulation on the photovoltaic modules considerably reduces the electricity conversion efficiency. In the current study, five optical filters utilizing various working fluids are paired with a photovoltaic module and experimentally compared to the stand-alone photovoltaic module aiming to enhance its output and efficiency. In the current evaluation, the Monte Carlo technique is used to examine and compare the performance of the suggested optical filters. Glycerin, ethyl alcohol, oil, air, and water are the working fluids for the suggested configurations. The Monte-Carlo method indicates that the optical filter employing water has the maximum efficiency among the proposed working fluids. The consequences reveal that the electrical efficiency of the setup using water as a working fluid is the greatest, followed by structures using glycerin, oil, ethyl alcohol, air, and standalone PV modules, which have values of 7.74, 7.59, 7.51, 7.38, 7.19 and 5.17%, respectively.
- Open Access
- 29 October 2019
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 11 (10)
Performance enhancement of an adsorption chiller by optimum cycle time allocation at different operating conditions
This article aims to improve the system cooling capacity of an adsorption chiller working with a silica gel/water pair by an allocation of the optimum cycle time at different operating conditions. A mathematical model was established and validated with the literature experimental data to predict the optimum cycle time for a wide range of hot (55°C–95°C), cooling (25°C–40°C), and chilled (10°C–22°C) water inlet temperatures. The optimum and conventional chiller performances are compared at different operating conditions. Enhancement ratio of the system cooling capacity was tripled as the cooling water inlet temperature increased from 25°C to 40°C at constant hot and chilled water inlet temperatures of 85°C and 14°C, respectively. Applying the concept of the optimum cycle time allocation, the system cooling capacity enhancement ratio can reach 15.6% at hot, cooling, and chilled water inlet temperatures of 95°C, 40°C, and 10°C, respectively.
- 29 October 2019
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 11 (10)
Open AccessPerformance enhancement of an adsorption chiller by optimum cycle time allocation at different operating conditions
This article aims to improve the system cooling capacity of an adsorption chiller working with a silica gel/water pair by an allocation of the optimum cycle time at different operating conditions. A mathematical model was established and validated with the literature experimental data to predict the optimum cycle time for a wide range of hot (55°C–95°C), cooling (25°C–40°C), and chilled (10°C–22°C) water inlet temperatures. The optimum and conventional chiller performances are compared at different operating conditions. Enhancement ratio of the system cooling capacity was tripled as the cooling water inlet temperature increased from 25°C to 40°C at constant hot and chilled water inlet temperatures of 85°C and 14°C, respectively. Applying the concept of the optimum cycle time allocation, the system cooling capacity enhancement ratio can reach 15.6% at hot, cooling, and chilled water inlet temperatures of 95°C, 40°C, and 10°C, respectively.
- Open Access
- 29 September 2019
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 11 (9)
Effect of geometrical factors interactions on design optimization process of a natural gas ejector
Enhancing the ejector entrainment ratio plays an important role in the ejector performance. In this article, a surrogate-based optimization approach along with computational fluid dynamics technique has been employed to optimize the entrainment ratio of a single-phase ejector working with natural gas. Nine ejector geometrical factors have been varied to maximize the ejector entrainment ratio. Validation results of the presented computational fluid dynamics model were in a good agreement with the experimental data from the literature with an average error of 0.6% in the critical mode. Reported results showed that the optimum design achieves entrainment ratio of 19.45% at 12, 2, and 5.2 MPa motive pressure, induced pressure, and discharge pressure, respectively. Moreover, the primary nozzle convergent angle and throat length are insignificant factors. Furthermore, secondary nozzle inclination angle has a minor effect on the entrainment ratio of the optimum design.
- 29 September 2019
- Published by SAGE Publications in Advances in Mechanical Engineering
- Vol. 11 (9)
Open AccessEffect of geometrical factors interactions on design optimization process of a natural gas ejector
Enhancing the ejector entrainment ratio plays an important role in the ejector performance. In this article, a surrogate-based optimization approach along with computational fluid dynamics technique has been employed to optimize the entrainment ratio of a single-phase ejector working with natural gas. Nine ejector geometrical factors have been varied to maximize the ejector entrainment ratio. Validation results of the presented computational fluid dynamics model were in a good agreement with the experimental data from the literature with an average error of 0.6% in the critical mode. Reported results showed that the optimum design achieves entrainment ratio of 19.45% at 12, 2, and 5.2 MPa motive pressure, induced pressure, and discharge pressure, respectively. Moreover, the primary nozzle convergent angle and throat length are insignificant factors. Furthermore, secondary nozzle inclination angle has a minor effect on the entrainment ratio of the optimum design.
- 1 January 2018
- Published by Elsevier in International Journal of Refrigeration
- Vol. 85, 268-281
Experimental assessment of a split air conditioner working with R-417A under different indoor and outdoor conditions
- 1 January 2018
- Published by Elsevier in International Journal of Refrigeration
- Vol. 85, 268-281
Experimental assessment of a split air conditioner working with R-417A under different indoor and outdoor conditions
- Open Access
- 1 April 2017
- Published by Egyptian Knowledge Bank in Journal of Engineering Science and Military Technologies
- Vol. 17 (17) , 1-15
Parametric Study of an Adsorption Refrigeration System Using Different Working Pairs
Journal of Engineering Science and Military Technologies (EJMTC)
- 1 April 2017
- Published by Egyptian Knowledge Bank in Journal of Engineering Science and Military Technologies
- Vol. 17 (17) , 1-15
Open AccessParametric Study of an Adsorption Refrigeration System Using Different Working Pairs
Journal of Engineering Science and Military Technologies (EJMTC)