Arash Salarian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arash Salarian has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Kamiar Aminian
Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland
8 shared publications - Laurie A. King
Department of Neurology, Oregon Health & Science University , Portland, OR 97239
4 shared publications - Patricia Carlson-Kuhta
Department of Neurology, Oregon Health & Science University, Portland, OR, USA
4 shared publications Fay B. Horak
Department of Neurology, Oregon Health & Science University, Portland, OR 97239, USA
3 shared publications- Fay Bahling Horak
Department of Neurology Oregon Health and Science University Portland Oregon USA
3 shared publications Pierre R. Burkhard
Department of Neurology, Hôpitaux Universitaires de Genève, Geneva, Switzerland
3 shared publications
Latest Publications
- Open Access
- 19 May 2026
- Published by Elsevier in SSRN Electronic Journal
Multi-Agent Systems have Some More to Learn from Human Multi-Agent Systems
In building more intelligent systems, should the goal be to enhance the capabilities of individual large models, or to compose a distributed intelligence from cooperating agents? Continuously improving individual models has produced savant-like behavior in many domains, but the results of building LLM-based multi-agent systems have been mixed Designing high-performing multi-agent systems faces obstacles such as effectively sharing intent and context in agent interactions, sometimes leading to worse outcomes for agent collectives. Much of current AI research fails to address fundamental challenges in basic human interaction and to apply basic concepts for team collaboration. This position paper argues that to improve scaling of LLM-based multi-agent systems horizontally -- with more agents -- these systems must build on theory in cognitive science on shared agency and extended mind coupled with theory and practice from organizational psychology on high-performing human teams. We describe how the theoretical foundations from these disparate research areas, when operationalized with a set of collective cognitive scaffolds, can provide new vectors for scaling multi-agent social cognitive capabilities for distributed intelligence.
- 19 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMulti-Agent Systems have Some More to Learn from Human Multi-Agent Systems
In building more intelligent systems, should the goal be to enhance the capabilities of individual large models, or to compose a distributed intelligence from cooperating agents? Continuously improving individual models has produced savant-like behavior in many domains, but the results of building LLM-based multi-agent systems have been mixed Designing high-performing multi-agent systems faces obstacles such as effectively sharing intent and context in agent interactions, sometimes leading to worse outcomes for agent collectives. Much of current AI research fails to address fundamental challenges in basic human interaction and to apply basic concepts for team collaboration. This position paper argues that to improve scaling of LLM-based multi-agent systems horizontally -- with more agents -- these systems must build on theory in cognitive science on shared agency and extended mind coupled with theory and practice from organizational psychology on high-performing human teams. We describe how the theoretical foundations from these disparate research areas, when operationalized with a set of collective cognitive scaffolds, can provide new vectors for scaling multi-agent social cognitive capabilities for distributed intelligence.
- Open Access
A novel audio representation using space filling curves
Since convolutional neural networks (CNNs) have revolutionized the image processing field, they have been widely applied in the audio context. A common approach is to convert the one-dimensional audio signal time series to two-dimensional images using a time-frequency decomposition method. Also it is common to discard the phase information. In this paper, we propose to map one-dimensional audio waveforms to two-dimensional images using space filling curves (SFCs). These mappings do not compress the input signal, while preserving its local structure. Moreover, the mappings benefit from progress made in deep learning and the large collection of existing computer vision networks. We test eight SFCs on two keyword spotting problems. We show that the Z curve yields the best results due to its shift equivariance under convolution operations. Additionally, the Z curve produces comparable results to the widely used mel frequency cepstral coefficients across multiple CNNs.
Open AccessA novel audio representation using space filling curves
Since convolutional neural networks (CNNs) have revolutionized the image processing field, they have been widely applied in the audio context. A common approach is to convert the one-dimensional audio signal time series to two-dimensional images using a time-frequency decomposition method. Also it is common to discard the phase information. In this paper, we propose to map one-dimensional audio waveforms to two-dimensional images using space filling curves (SFCs). These mappings do not compress the input signal, while preserving its local structure. Moreover, the mappings benefit from progress made in deep learning and the large collection of existing computer vision networks. We test eight SFCs on two keyword spotting problems. We show that the Z curve yields the best results due to its shift equivariance under convolution operations. Additionally, the Z curve produces comparable results to the widely used mel frequency cepstral coefficients across multiple CNNs.
- 1 January 2016
- Published by Elsevier in Gait & Posture
- Vol. 43, 125-131
Validity and reliability of an IMU-based method to detect APAs prior to gait initiation
- 1 January 2016
- Published by Elsevier in Gait & Posture
- Vol. 43, 125-131
Validity and reliability of an IMU-based method to detect APAs prior to gait initiation
- Open Access
- 1 January 2013
- Published by Wiley in Parkinson's Disease
- Vol. 2013, 1-9
Exploring Outcome Measures for Exercise Intervention in People with Parkinson’s Disease
Background. It is widely believed that exercise improves mobility in people with Parkinson’s disease (PD). However, it is difficult to determine whether a specific type of exercise is the most effective. The purpose of this study was to determine which outcome measures were sensitive to exercise intervention and to explore the effects of two different exercise programs for improving mobility in patients with PD.Methods. Participants were randomized into either the Agility Boot Camp (ABC) or treadmill training; 4x/week for 4 weeks. Outcome measures were grouped by the International Classification of Function/Disability (ICF). To determine the responsiveness to exercise, we calculated the standardized response means.-tests were used to compare the relative benefits of each exercise program.Results. Four of five variables at the structure/function level changed after exercise: turn duration (), stride velocity (), peak arm speed (), and horizontal trunk ROM during gait (). Most measures improved similarly for both interventions. The only variable that detected a difference between groups was postural sway in ABC group (;).Conclusion. Outcome measures at ICF body structure/function level were most effective at detecting change after exercise and revealing differences in improvement between interventions.- 1 January 2013
- Published by Wiley in Parkinson's Disease
- Vol. 2013, 1-9
Open AccessExploring Outcome Measures for Exercise Intervention in People with Parkinson’s Disease
Background. It is widely believed that exercise improves mobility in people with Parkinson’s disease (PD). However, it is difficult to determine whether a specific type of exercise is the most effective. The purpose of this study was to determine which outcome measures were sensitive to exercise intervention and to explore the effects of two different exercise programs for improving mobility in patients with PD.Methods. Participants were randomized into either the Agility Boot Camp (ABC) or treadmill training; 4x/week for 4 weeks. Outcome measures were grouped by the International Classification of Function/Disability (ICF). To determine the responsiveness to exercise, we calculated the standardized response means.-tests were used to compare the relative benefits of each exercise program.Results. Four of five variables at the structure/function level changed after exercise: turn duration (), stride velocity (), peak arm speed (), and horizontal trunk ROM during gait (). Most measures improved similarly for both interventions. The only variable that detected a difference between groups was postural sway in ABC group (;).Conclusion. Outcome measures at ICF body structure/function level were most effective at detecting change after exercise and revealing differences in improvement between interventions. - 9 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (1) , 72-77
A Novel Approach to Reducing Number of Sensing Units for Wearable Gait Analysis Systems
Gait analysis methods to estimate spatiotemporal measures, based on two, three or four gyroscopes attached on lower limbs have been discussed in the literature. The most common approach to reduce the number of sensing units is to simplify the underlying biomechanical gait model. In this study, we propose a novel method based on prediction of movements of thighs from movements of shanks. Datasets from three previous studies were used. Data from the first study (ten healthy subjects and ten with Parkinson's disease) were used to develop and calibrate a system with only two gyroscopes attached on shanks. Data from two other studies (36 subjects with hip replacement, seven subjects with coxarthrosis, and eight control subjects) were used for comparison with the other methods and for assessment of error compared to a motion capture system. Results show that the error of estimation of stride length compared to motion capture with the system with four gyroscopes and our new method based on two gyroscopes was close ( -0.8 ±6.6 versus 3.8 ±6.6 cm). An alternative with three sensing units did not show better results (error: -0.2 ±8.4 cm). Finally, a fourth that also used two units but with a simpler gait model had the highest bias compared to the reference (error: -25.6 ±7.6 cm). We concluded that it is feasible to estimate movements of thighs from movements of shanks to reduce number of needed sensing units from 4 to 2 in context of ambulatory gait analysis.
- 9 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (1) , 72-77
A Novel Approach to Reducing Number of Sensing Units for Wearable Gait Analysis Systems
Gait analysis methods to estimate spatiotemporal measures, based on two, three or four gyroscopes attached on lower limbs have been discussed in the literature. The most common approach to reduce the number of sensing units is to simplify the underlying biomechanical gait model. In this study, we propose a novel method based on prediction of movements of thighs from movements of shanks. Datasets from three previous studies were used. Data from the first study (ten healthy subjects and ten with Parkinson's disease) were used to develop and calibrate a system with only two gyroscopes attached on shanks. Data from two other studies (36 subjects with hip replacement, seven subjects with coxarthrosis, and eight control subjects) were used for comparison with the other methods and for assessment of error compared to a motion capture system. Results show that the error of estimation of stride length compared to motion capture with the system with four gyroscopes and our new method based on two gyroscopes was close ( -0.8 ±6.6 versus 3.8 ±6.6 cm). An alternative with three sensing units did not show better results (error: -0.2 ±8.4 cm). Finally, a fourth that also used two units but with a simpler gait model had the highest bias compared to the reference (error: -25.6 ±7.6 cm). We concluded that it is feasible to estimate movements of thighs from movements of shanks to reduce number of needed sensing units from 4 to 2 in context of ambulatory gait analysis.
- 1 April 2012
- Published by Elsevier in Gait & Posture
- Vol. 35 (4) , 573-578
Body-worn motion sensors detect balance and gait deficits in people with multiple sclerosis who have normal walking speed
- 1 April 2012
- Published by Elsevier in Gait & Posture
- Vol. 35 (4) , 573-578
Body-worn motion sensors detect balance and gait deficits in people with multiple sclerosis who have normal walking speed
- 1 March 2012
- Published by Wolters Kluwer Health in Journal of Neurologic Physical Therapy
- Vol. 36 (1) , 25-31
Do Clinical Scales of Balance Reflect Turning Abnormalities in People With Parkinson's Disease?
Background and Purpose: It is well known that people with Parkinson's disease (PD) have significant difficulty turning, and that such difficulty is related to freezing episodes and falls. However, it is unclear how clinicians should evaluate turning. The purpose of this exploratory study was to determine whether the common clinical assessment instruments reflect turning deficits in persons with PD compared with an instrumented measure. Methods: Forty-six participants with PD (23 with mild PD, and 23 with severe PD), and 40 healthy controls were assessed using the Berg Balance Scale (Berg), Tinetti Mobility Test (Tinetti), Activities-Specific Balance Confidence Scale, and the new instrumented Timed Up & Go test using wearable inertial sensors. Results: Turns during the instrumented Timed Up & Go test showed significant differences among groups (χ2 = 43.6, P < 0.0001). Specifically, controls and mild PD (P < 0.001) and controls and severe PD (P < 0.00001). The number of steps (χ2 = 32.1; P < 0.0001) and peak speed (χ2 = 31.9; P < 0.0001) during turning were significantly different among all groups. Clinical scales were less likely to detect these differences. Of the clinical scales, the Berg was best able to detect differences between control and mild PD groups. Correlations between clinical measures of balance and instrumented turning were moderate but significant. Conclusions: We show evidence that turning is impaired, even in mildly impaired participants with PD and that this deficit is not obviously reflected in common clinical scales of balance such as the Berg or Tinetti. It may be more useful for a clinician to examine particular items within the Berg or the turning component of the TUG if turning difficulty is suspected.
- 1 March 2012
- Published by Wolters Kluwer Health in Journal of Neurologic Physical Therapy
- Vol. 36 (1) , 25-31
Do Clinical Scales of Balance Reflect Turning Abnormalities in People With Parkinson's Disease?
Background and Purpose: It is well known that people with Parkinson's disease (PD) have significant difficulty turning, and that such difficulty is related to freezing episodes and falls. However, it is unclear how clinicians should evaluate turning. The purpose of this exploratory study was to determine whether the common clinical assessment instruments reflect turning deficits in persons with PD compared with an instrumented measure. Methods: Forty-six participants with PD (23 with mild PD, and 23 with severe PD), and 40 healthy controls were assessed using the Berg Balance Scale (Berg), Tinetti Mobility Test (Tinetti), Activities-Specific Balance Confidence Scale, and the new instrumented Timed Up & Go test using wearable inertial sensors. Results: Turns during the instrumented Timed Up & Go test showed significant differences among groups (χ2 = 43.6, P < 0.0001). Specifically, controls and mild PD (P < 0.001) and controls and severe PD (P < 0.00001). The number of steps (χ2 = 32.1; P < 0.0001) and peak speed (χ2 = 31.9; P < 0.0001) during turning were significantly different among all groups. Clinical scales were less likely to detect these differences. Of the clinical scales, the Berg was best able to detect differences between control and mild PD groups. Correlations between clinical measures of balance and instrumented turning were moderate but significant. Conclusions: We show evidence that turning is impaired, even in mildly impaired participants with PD and that this deficit is not obviously reflected in common clinical scales of balance such as the Berg or Tinetti. It may be more useful for a clinician to examine particular items within the Berg or the turning component of the TUG if turning difficulty is suspected.
- Top Cited PapersOpen Access
- 1 January 2012
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 9 (1) , 59
ISway: a sensitive, valid and reliable measure of postural control
Clinicians need a practical, objective test of postural control that is sensitive to mild neurological disease, shows experimental and clinical validity, and has good test-retest reliability. We developed an instrumented test of postural sway (ISway) using a body-worn accelerometer to offer an objective and practical measure of postural control.
- 1 January 2012
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 9 (1) , 59
Top Cited PapersOpen AccessISway: a sensitive, valid and reliable measure of postural control
Clinicians need a practical, objective test of postural control that is sensitive to mild neurological disease, shows experimental and clinical validity, and has good test-retest reliability. We developed an instrumented test of postural sway (ISway) using a body-worn accelerometer to offer an objective and practical measure of postural control.
- Open Access
- 24 October 2011
- Published by Wiley in Parkinson's Disease
- Vol. 2012, 1-7
Comparing the Mini-BESTest with the Berg Balance Scale to Evaluate Balance Disorders in Parkinson's Disease
Objective. The purpose of this study was to explore the usefulness of the Mini-BESTest compared to the Berg Balance Scale in evaluating balance in people with PD of varying severity. We evaluated (1) the distribution of patients scores to look for ceiling effects, (2) concurrent validity with severity of disease, and (3) the sensitivity/specificity of separating people with or without postural response deficits.Subjects. Ninety-seven people with PD were tested for balance deficits using the Berg, Mini-BESTest, Unified Parkinson’s Disease Rating Scale (UPDRS) III and the Hoehn & Yahr (H&Y) disease severity classification.Setting. Clinical research facility at Oregon Health & Science University.Results. The Mini-BESTest is highly correlated with the Berg (,), but avoids the ceiling compression effect of the Berg for mild PD (skewness −2.30 Berg, −0.93 Mini-BESTest). Consequently, the Mini-BESTest is more effective than the Berg for predicting UPDRS Motor score (Mini-BESTest versusBerg), and for discriminating between those with and without postural response deficits as measured by the H&Y (ROC differential).Conclusion. The Mini-BESTest is a promising tool for discerning balance deficits in patients with PD, most importantly those with more subtle deficits.- 24 October 2011
- Published by Wiley in Parkinson's Disease
- Vol. 2012, 1-7
Open AccessComparing the Mini-BESTest with the Berg Balance Scale to Evaluate Balance Disorders in Parkinson's Disease
Objective. The purpose of this study was to explore the usefulness of the Mini-BESTest compared to the Berg Balance Scale in evaluating balance in people with PD of varying severity. We evaluated (1) the distribution of patients scores to look for ceiling effects, (2) concurrent validity with severity of disease, and (3) the sensitivity/specificity of separating people with or without postural response deficits.Subjects. Ninety-seven people with PD were tested for balance deficits using the Berg, Mini-BESTest, Unified Parkinson’s Disease Rating Scale (UPDRS) III and the Hoehn & Yahr (H&Y) disease severity classification.Setting. Clinical research facility at Oregon Health & Science University.Results. The Mini-BESTest is highly correlated with the Berg (,), but avoids the ceiling compression effect of the Berg for mild PD (skewness −2.30 Berg, −0.93 Mini-BESTest). Consequently, the Mini-BESTest is more effective than the Berg for predicting UPDRS Motor score (Mini-BESTest versusBerg), and for discriminating between those with and without postural response deficits as measured by the H&Y (ROC differential).Conclusion. The Mini-BESTest is a promising tool for discerning balance deficits in patients with PD, most importantly those with more subtle deficits. - 2 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (7) , 2127-2135
A new measure of movement symmetry in early Parkinson's disease patients using symbolic processing of inertial sensor data
Movement asymmetry is one of the motor symptoms associated with Parkinson's disease (PD). Therefore, being able to detect and measure movement symmetry is important for monitoring the patient's condition. The present paper introduces a novel symbol based symmetry index calculated from inertial sensor data. The method is explained, evaluated, and compared to six other symmetry measures. These measures were used to determine the symmetry of both upper and lower limbs during walking of 11 early-to-mid-stage PD patients and 15 control subjects. The patients included in the study showed minimal motor abnormalities according to the unified Parkinson's disease rating scale (UPDRS). The symmetry indices were used to classify subjects into two different groups corresponding to PD or control. The proposed method presented high sensitivity and specificity with an area under the receiver operating characteristic (ROC) curve of 0.872, 9% greater than the second best method. The proposed method also showed an excellent intraclass correlation coefficient (ICC) of 0.949, 55% greater than the second best method. Results suggest that the proposed symmetry index is appropriate for this particular group of patients.
- 2 May 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (7) , 2127-2135
A new measure of movement symmetry in early Parkinson's disease patients using symbolic processing of inertial sensor data
Movement asymmetry is one of the motor symptoms associated with Parkinson's disease (PD). Therefore, being able to detect and measure movement symmetry is important for monitoring the patient's condition. The present paper introduces a novel symbol based symmetry index calculated from inertial sensor data. The method is explained, evaluated, and compared to six other symmetry measures. These measures were used to determine the symmetry of both upper and lower limbs during walking of 11 early-to-mid-stage PD patients and 15 control subjects. The patients included in the study showed minimal motor abnormalities according to the unified Parkinson's disease rating scale (UPDRS). The symmetry indices were used to classify subjects into two different groups corresponding to PD or control. The proposed method presented high sensitivity and specificity with an area under the receiver operating characteristic (ROC) curve of 0.872, 9% greater than the second best method. The proposed method also showed an excellent intraclass correlation coefficient (ICC) of 0.949, 55% greater than the second best method. Results suggest that the proposed symmetry index is appropriate for this particular group of patients.