Oliver Millan-Blasco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oliver Millan-Blasco has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Miguel J. Garcia-Hernandez
Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Barcelona, Spain
6 shared publicationsAntoni Turo
Sensor System Group. Department of Electronic Engineering, Universitat Politècnica de Catalunya, Jordi Girona 1-3, 08034 Barcelona, Spain
5 shared publicationsJordi Salazar
Sensor System Group. Department of Electronic Engineering Universitat Politècnica de Catalunya Jordi Girona 1-3, 08034 Barcelona, Spain
4 shared publications- Juan Antonio Chavez
Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Barcelona, Spain
4 shared publications - Herminio Martinez-Garcia
Department of Electronic Engineering, Eastern Barcelona School of Engineering (EEBE), Universitat Politècnica de Catalunya—BarcelonaTech (UPC, Technical University of Catalonia), E-08019 Barcelona, Spain
3 shared publications - Jordi Salazar
Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Barcelona, Spain
2 shared publications
Latest Publications
- Open Access
- 22 July 2026
- Published by Elsevier in Measurement
- Vol. 289
Capacitance-based detection of tissue freezing for real-time cryotherapy monitoring
- 22 July 2026
- Published by Elsevier in Measurement
- Vol. 289
Open AccessCapacitance-based detection of tissue freezing for real-time cryotherapy monitoring
- Open Access
Fractional-Order Bioimpedance Modelling for Early Detection of Tissue Freezing in Cryogenic and Thermal Medical Applications
Cryotherapy and radiofrequency (RF) treatments modulate tissue temperature to induce therapeutic effects; however, improper application can result in thermal injury. Traditional temperature-based monitoring methods rely on multiple thermal sensors whose accuracy strongly depends on their number and spatial positioning, often failing to detect early tissue crystallization. This study introduces a fractional order bioimpedance modelling framework for the early detection of tissue freezing during cryogenic and thermal medical treatments, with the feasibility and effectiveness of this approach having been reported in our prior publications. While bioimpedance spectroscopy itself is a well-est. The corresponablished technique in biomedical engineering, its novel application to predict and identify premature freezing events provides a new pathway for safe and efficient energy-based therapies. Fractional-order models derived from the Cole family accurately reproduce the complex electrical behavior of biological tissues using fewer parameters than classical integer-order models, thus reducing both hardware requirements and computational cost. Experimental impedance data from human abdominal, gluteal, and femoral regions were modelled to extract fractional parameters that serve as sensitive indicators of phase-transition onset. The results demonstrate that the proposed approach enables real-time identification of freezing-induced electrical transitions, offering a physiologically grounded alternative to conventional temperature-based monitoring. Furthermore, the fractional order bioimpedance method exhibits high reproducibility and selectivity, and its analytical figures of merit, including the limits of detection and quantification, support its use for reliable real-time tissue monitoring and early injury detection. Overall, the proposed fractional order bioimpedance framework enhances both safety and control precision in cryogenic and thermal medical applications.
Open AccessFractional-Order Bioimpedance Modelling for Early Detection of Tissue Freezing in Cryogenic and Thermal Medical Applications
Cryotherapy and radiofrequency (RF) treatments modulate tissue temperature to induce therapeutic effects; however, improper application can result in thermal injury. Traditional temperature-based monitoring methods rely on multiple thermal sensors whose accuracy strongly depends on their number and spatial positioning, often failing to detect early tissue crystallization. This study introduces a fractional order bioimpedance modelling framework for the early detection of tissue freezing during cryogenic and thermal medical treatments, with the feasibility and effectiveness of this approach having been reported in our prior publications. While bioimpedance spectroscopy itself is a well-est. The corresponablished technique in biomedical engineering, its novel application to predict and identify premature freezing events provides a new pathway for safe and efficient energy-based therapies. Fractional-order models derived from the Cole family accurately reproduce the complex electrical behavior of biological tissues using fewer parameters than classical integer-order models, thus reducing both hardware requirements and computational cost. Experimental impedance data from human abdominal, gluteal, and femoral regions were modelled to extract fractional parameters that serve as sensitive indicators of phase-transition onset. The results demonstrate that the proposed approach enables real-time identification of freezing-induced electrical transitions, offering a physiologically grounded alternative to conventional temperature-based monitoring. Furthermore, the fractional order bioimpedance method exhibits high reproducibility and selectivity, and its analytical figures of merit, including the limits of detection and quantification, support its use for reliable real-time tissue monitoring and early injury detection. Overall, the proposed fractional order bioimpedance framework enhances both safety and control precision in cryogenic and thermal medical applications.
- Open Access
Fractional-Order Electrical Modeling of Aluminum Coated via Plasma Electro-Oxidation and Thermal Spray Methods to Optimize Radiofrequency Medical Devices
Active medical devices rely on a source of energy that is applied to the human body for specific purposes such as electrosurgery, ultrasounds for breaking up kidney stones (lithotripsy), laser irradiation, and other medical techniques and procedures that are extensively used. These systems must provide adequate working power with a commitment not to produce side effects on patients. Therefore, the materials used in these devices must effectively transmit energy, allow for security control, sense real-time variations in case of any issues, and ensure the implementation of closed-loop systems for control. This work extends to the experimental data adjustment of some different coating techniques based on plasma electro-oxidation (PEO) and thermal spray (TS) using fractional-order models. According to the physical structure of the coating in different coating techniques, Cole family models were selected. The experimental data were obtained by means of a vector network analyzer (VNA) in the frequency spectrum from 0.3 MHz to 5 MHz. The results show that some models from the Cole family (the single-dispersion model and inductive model) offered a goodness of fit to the experimental impedance in terms of RMSE error and a squared error R2 close to unity. The use of this type of fractional-order electrical model allows an adjustment with a very small number of elements compared to integer-order models, facilitating its use and a consequent reduction in instrumentation cost and the development of control devices that are more robust and easily miniaturized for embedded applications. Additionally, fractional-order models allow for more accurate assessment in industrial and medical applications.
Open AccessFractional-Order Electrical Modeling of Aluminum Coated via Plasma Electro-Oxidation and Thermal Spray Methods to Optimize Radiofrequency Medical Devices
Active medical devices rely on a source of energy that is applied to the human body for specific purposes such as electrosurgery, ultrasounds for breaking up kidney stones (lithotripsy), laser irradiation, and other medical techniques and procedures that are extensively used. These systems must provide adequate working power with a commitment not to produce side effects on patients. Therefore, the materials used in these devices must effectively transmit energy, allow for security control, sense real-time variations in case of any issues, and ensure the implementation of closed-loop systems for control. This work extends to the experimental data adjustment of some different coating techniques based on plasma electro-oxidation (PEO) and thermal spray (TS) using fractional-order models. According to the physical structure of the coating in different coating techniques, Cole family models were selected. The experimental data were obtained by means of a vector network analyzer (VNA) in the frequency spectrum from 0.3 MHz to 5 MHz. The results show that some models from the Cole family (the single-dispersion model and inductive model) offered a goodness of fit to the experimental impedance in terms of RMSE error and a squared error R2 close to unity. The use of this type of fractional-order electrical model allows an adjustment with a very small number of elements compared to integer-order models, facilitating its use and a consequent reduction in instrumentation cost and the development of control devices that are more robust and easily miniaturized for embedded applications. Additionally, fractional-order models allow for more accurate assessment in industrial and medical applications.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Characterization of nonhomogeneity in the dispersive properties of the materials used in pipes
Accurate measurement of acoustic dispersion has important applications in theoretical acoustics, ultrasound tissue characterization, ultrasound measurement systems, etc. Usually, the parameter of interest associated to dispersion is the variation in the propagation velocity as a function of the frequency or the temperature. Nevertheless, this work is focused on the study of the variation in the propagation velocity caused by the intensity of the acoustic signal. As a consequence, the lack of homogeneity in dispersive properties of polymeric materials, as a function of the signal power, produces a measurement error in Clamp-on ultrasonic flowmeters.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Characterization of nonhomogeneity in the dispersive properties of the materials used in pipes
Accurate measurement of acoustic dispersion has important applications in theoretical acoustics, ultrasound tissue characterization, ultrasound measurement systems, etc. Usually, the parameter of interest associated to dispersion is the variation in the propagation velocity as a function of the frequency or the temperature. Nevertheless, this work is focused on the study of the variation in the propagation velocity caused by the intensity of the acoustic signal. As a consequence, the lack of homogeneity in dispersive properties of polymeric materials, as a function of the signal power, produces a measurement error in Clamp-on ultrasonic flowmeters.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Splitting of the ultrasounic beam path in clamp-on ultrasonic flowmeters due to propagation through dispersive materials
This article explains how a multi-frequency ultrasonic beam path is split due to passing through dispersive materials and the implications that it has in flow measurement using a Clamp-on ultrasonic flowmeter. The importance of knowing this phenomenon is because dispersive materials are commonly used in the manufacture of transducer wedges and plastic pipes. Splitting of the ultrasonic beam path occurs when the incident angle is not normal to the surface of the pipe and a coupling wedge is necessary. The diffraction angle is produced at the boundaries among materials with different propagation velocities (according to Snell's law), and furthermore, in dispersive materials, the propagation speed depends on frequency. Therefore, when the excitation signal contains several frequential components, each frequency travels with a different velocity. Under this circumstance, different diffraction angles are produced for each frequency at the boundaries between materials. As a result of splitting the path, the ultrasonic beam widens and the reception transducer aperture becomes too small to receive all the frequential components contained in the ultrasonic beam. Thus, when the ultrasonic beam is carried by the liquid flowing inside the pipe, the reception transducer receives different frequential contributions, producing change in its spectral composition. As a consequence of the mixing of these frequencies, the reception signal is modulated in phase and amplitude. Moreover, modulation will change as a function of frequential composition that is combined at the reception transducer. This is the origin of the linearity error in Clamp-on ultrasonic flowmeters.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Splitting of the ultrasounic beam path in clamp-on ultrasonic flowmeters due to propagation through dispersive materials
This article explains how a multi-frequency ultrasonic beam path is split due to passing through dispersive materials and the implications that it has in flow measurement using a Clamp-on ultrasonic flowmeter. The importance of knowing this phenomenon is because dispersive materials are commonly used in the manufacture of transducer wedges and plastic pipes. Splitting of the ultrasonic beam path occurs when the incident angle is not normal to the surface of the pipe and a coupling wedge is necessary. The diffraction angle is produced at the boundaries among materials with different propagation velocities (according to Snell's law), and furthermore, in dispersive materials, the propagation speed depends on frequency. Therefore, when the excitation signal contains several frequential components, each frequency travels with a different velocity. Under this circumstance, different diffraction angles are produced for each frequency at the boundaries between materials. As a result of splitting the path, the ultrasonic beam widens and the reception transducer aperture becomes too small to receive all the frequential components contained in the ultrasonic beam. Thus, when the ultrasonic beam is carried by the liquid flowing inside the pipe, the reception transducer receives different frequential contributions, producing change in its spectral composition. As a consequence of the mixing of these frequencies, the reception signal is modulated in phase and amplitude. Moreover, modulation will change as a function of frequential composition that is combined at the reception transducer. This is the origin of the linearity error in Clamp-on ultrasonic flowmeters.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Influence on the accuracy of clamp-on ultrasonic flowmeters due to the recombination of multiple propagation paths
The following topics are dealt with: biomedical ultrasonics; medical image processing; ultrasonic imaging; biological tissues; ultrasonic transducers; biomechanics; blood vessels; biomedical transducers; diseases; and cancer.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Influence on the accuracy of clamp-on ultrasonic flowmeters due to the recombination of multiple propagation paths
The following topics are dealt with: biomedical ultrasonics; medical image processing; ultrasonic imaging; biological tissues; ultrasonic transducers; biomechanics; blood vessels; biomedical transducers; diseases; and cancer.
- 10 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 66 (11) , 2845-2851
Zero-Flow Offset Variation in Ultrasonic Clamp-On Flowmeters Due to Inhomogeneity and Nonlinearity of Pipe Materials
The objective of this paper is to measure the zero-flow offset variation in ultrasonic Clamp-on flowmeters produced by using pipes made of materials with a nonhomogeneous and nonlinear behavior. The evaluation of this phenomenon has been tested by the experimental measurement, the experiments consist of measuring the variation in the flow measurement when in “no-flow condition,” the transducers are moved along the pipe. Experimental results reveal that the reciprocity criterion is not fulfilled when nonhomogeneous and nonlinear pipe materials are used. Consequently, in these types of pipes materials, it is necessary to calibrate the offset when transducers are installed, and probably will need recalibration if the transducers are displaced to another position on the pipe. However, in installations, where it is not possible to stop flow in order to calibrate, the flowmeter will have an error in the measured value and this error will depend on the acoustic characteristics of the pipe material.
- 10 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 66 (11) , 2845-2851
Zero-Flow Offset Variation in Ultrasonic Clamp-On Flowmeters Due to Inhomogeneity and Nonlinearity of Pipe Materials
The objective of this paper is to measure the zero-flow offset variation in ultrasonic Clamp-on flowmeters produced by using pipes made of materials with a nonhomogeneous and nonlinear behavior. The evaluation of this phenomenon has been tested by the experimental measurement, the experiments consist of measuring the variation in the flow measurement when in “no-flow condition,” the transducers are moved along the pipe. Experimental results reveal that the reciprocity criterion is not fulfilled when nonhomogeneous and nonlinear pipe materials are used. Consequently, in these types of pipes materials, it is necessary to calibrate the offset when transducers are installed, and probably will need recalibration if the transducers are displaced to another position on the pipe. However, in installations, where it is not possible to stop flow in order to calibrate, the flowmeter will have an error in the measured value and this error will depend on the acoustic characteristics of the pipe material.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Comparison between sine wave fitting and zero-crossing methods applied to QCM impedance measurements
This paper presents a comparison between two algorithms for sinusoidal signal characterization applied to QCM impedance measurements. These algorithms are the zero crossing and peak detection method and the 7 parameters sine-fitting method. Simulation and experimental results from both methods are shown in order to determine which method provides the best performance in terms of accuracy. Obtaining a precise value of the QCM impedance depends directly on the precise measurement of the amplitude and phase of two sinusoidal voltages. It was found that the sine-fitting method achieves better results without an excessive associated computational burden. These results will be applied to the development of a new technique for biofilm characterization based on multiple QCM impedance measurements.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Comparison between sine wave fitting and zero-crossing methods applied to QCM impedance measurements
This paper presents a comparison between two algorithms for sinusoidal signal characterization applied to QCM impedance measurements. These algorithms are the zero crossing and peak detection method and the 7 parameters sine-fitting method. Simulation and experimental results from both methods are shown in order to determine which method provides the best performance in terms of accuracy. Obtaining a precise value of the QCM impedance depends directly on the precise measurement of the amplitude and phase of two sinusoidal voltages. It was found that the sine-fitting method achieves better results without an excessive associated computational burden. These results will be applied to the development of a new technique for biofilm characterization based on multiple QCM impedance measurements.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Linearity error in Clamp-on ultrasonic flowmeters due to the installation on pipes made of dispersive materials
This article analyses and explains the implications that dispersive materials have over the linearity in flow measurement when a Clamp-on ultrasonic flowmeter is used. This is of capital importance because dispersive materials are commonly used in the manufacture of transducer wedges and pipes. The evaluation of this phenomenon has been tested by experimental measurement. The used setup consisted of a water flow calibration facility where a commercial Clamp-on ultrasonic flowmeter was installed on it and its flow measurement was compared with a reference flowmeter. Two experiments have been conducted. A first experiment was performed to evaluate only the effect produced by the fact that the transducer wedge is made of dispersive material. For this reason, an ultrasonic flowmeter was installed on a pipe made of non-dispersive material, in this case, an INOX pipe. Linearity error introduced by the wedge was below 1%. This error complies with the accuracy specification of the ultrasonic flowmeter given by the manufacturer (±1.5%). Finally, a second experiment consisted of installing the ultrasonic flowmeter on a dispersive pipe (PVC pipe) in order to measure the worst condition (both materials, wedge and pipe, were dispersive). Under this condition, the linearity error was increased until it reaches a value of 6.4%. Moreover, in case of a dispersive material pipe, the bigger the pipe thickness is, the bigger non-linearity error is reached.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Linearity error in Clamp-on ultrasonic flowmeters due to the installation on pipes made of dispersive materials
This article analyses and explains the implications that dispersive materials have over the linearity in flow measurement when a Clamp-on ultrasonic flowmeter is used. This is of capital importance because dispersive materials are commonly used in the manufacture of transducer wedges and pipes. The evaluation of this phenomenon has been tested by experimental measurement. The used setup consisted of a water flow calibration facility where a commercial Clamp-on ultrasonic flowmeter was installed on it and its flow measurement was compared with a reference flowmeter. Two experiments have been conducted. A first experiment was performed to evaluate only the effect produced by the fact that the transducer wedge is made of dispersive material. For this reason, an ultrasonic flowmeter was installed on a pipe made of non-dispersive material, in this case, an INOX pipe. Linearity error introduced by the wedge was below 1%. This error complies with the accuracy specification of the ultrasonic flowmeter given by the manufacturer (±1.5%). Finally, a second experiment consisted of installing the ultrasonic flowmeter on a dispersive pipe (PVC pipe) in order to measure the worst condition (both materials, wedge and pipe, were dispersive). Under this condition, the linearity error was increased until it reaches a value of 6.4%. Moreover, in case of a dispersive material pipe, the bigger the pipe thickness is, the bigger non-linearity error is reached.