Bjørn Helge Østerås
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bjørn Helge Østerås has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Per Skaane
Department of Radiology, Oslo University Hospital, University of Oslo, Oslo, Norway
4 shared publications Hilde Kjernlie Andersen
Department of Diagnostic Physics, Oslo University Hospital, P.O. Box, 0454 Oslo, Norway
3 shared publicationsPer Skaane
Department of Radiology and Nuclear Medicine, Oslo University Hospital, Oslo, Oslo, NORWAY
3 shared publicationsRandi Gullien
Division of Radiology and Nuclear Medicine, Department of Breast Diagnostics, Oslo University Hospital, University of Oslo, Oslo, Norway
3 shared publicationsAnne Catrine T Martinsen
The Intervention Centre, Oslo University Hospital, Postbox 4950, Nydalen, 0424 Oslo, Norway
2 shared publicationsAnne Catrine T. Martinsen
From the Department of Diagnostic Physics (B.H.Ø., A.C.T.M.) and Division of Radiology and Nuclear Medicine (R.G., P.S.), Oslo University Hospital, Building 20, Gaustad, PO Box 4959, Nydalen, 0424 Oslo, Norway; and Institute of Clinical Medicine (B.H.Ø., P.S.) and Department of Physics (A.C.T.M.), University of Oslo, Oslo, Norway
2 shared publications
Latest Publications
- Open Access
- 26 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135041
Development and validation of XrayMC: a dedicated Monte Carlo tool for X-ray imaging and radiation protection
Objective: This work introduces and validates XrayMC, a novel Monte Carlo (MC) simulation tool specifically designed for photon transport and dose scoring in diagnostic X-ray imaging and image-guided interventional procedures. The tool aims to provide accurate, efficient, and flexible simulations for patient and staff dosimetry in complex imaging environments. Approach: XrayMC implements history-by-history photon transport for energies between 1–150 keV. It supports multiple geometry types such as voxel-grids, triangulated surfaces, and tetrahedral meshes, enabling detailed modelling of patients, staff, and imaging equipment. Common X-ray beam configurations used in diagnostic imaging, such as computed tomography (CT), cone beam CT (CBCT) and planar imaging, are included to make it easier to create clinically relevant X-ray beams. XrayMC is benchmarked against the AAPM Task Group 195 Monte Carlo reference dataset (TG195), with a total of 694 comparisons to reference data across five diagnostic imaging cases, including radiography, mammography, and CT. Main results: All imaging cases relevant to photon transport in TG195 were successfully replicated in XrayMC, and the results from XrayMC are in excellent agreement with those obtained with the TG195 reference MC packages (EGSnrc, Geant4, MCNP, and Penelope). Across all cases, the average deviation from TG195 was less than 0.5%, and 690 of the 694 comparisons between XrayMC and TG195 differed by less than 2%. The largest difference from the TG195 values was 3.6% for energy scored in the adrenals for CT exposures of a voxel phantom. Significance: XrayMC provides a tailored and optimised alternative to general-purpose MC codes for imaging applications. Its flexibility in geometry handling and validated accuracy make it suitable for research and clinical dose assessment, supporting improved radiation protection for patients and healthcare professionals. In addition, XrayMC allows visualisation of dose distributions and simulation set-ups that can aid teaching and understanding of radiation protection in imaging applications.
- 26 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135041
Open AccessDevelopment and validation of XrayMC: a dedicated Monte Carlo tool for X-ray imaging and radiation protection
Objective: This work introduces and validates XrayMC, a novel Monte Carlo (MC) simulation tool specifically designed for photon transport and dose scoring in diagnostic X-ray imaging and image-guided interventional procedures. The tool aims to provide accurate, efficient, and flexible simulations for patient and staff dosimetry in complex imaging environments. Approach: XrayMC implements history-by-history photon transport for energies between 1–150 keV. It supports multiple geometry types such as voxel-grids, triangulated surfaces, and tetrahedral meshes, enabling detailed modelling of patients, staff, and imaging equipment. Common X-ray beam configurations used in diagnostic imaging, such as computed tomography (CT), cone beam CT (CBCT) and planar imaging, are included to make it easier to create clinically relevant X-ray beams. XrayMC is benchmarked against the AAPM Task Group 195 Monte Carlo reference dataset (TG195), with a total of 694 comparisons to reference data across five diagnostic imaging cases, including radiography, mammography, and CT. Main results: All imaging cases relevant to photon transport in TG195 were successfully replicated in XrayMC, and the results from XrayMC are in excellent agreement with those obtained with the TG195 reference MC packages (EGSnrc, Geant4, MCNP, and Penelope). Across all cases, the average deviation from TG195 was less than 0.5%, and 690 of the 694 comparisons between XrayMC and TG195 differed by less than 2%. The largest difference from the TG195 values was 3.6% for energy scored in the adrenals for CT exposures of a voxel phantom. Significance: XrayMC provides a tailored and optimised alternative to general-purpose MC codes for imaging applications. Its flexibility in geometry handling and validated accuracy make it suitable for research and clinical dose assessment, supporting improved radiation protection for patients and healthcare professionals. In addition, XrayMC allows visualisation of dose distributions and simulation set-ups that can aid teaching and understanding of radiation protection in imaging applications.
- Open Access
- 8 November 2023
- Published by Springer Nature in European Radiology
- Vol. 34 (6) , 3912-3923
Discordant and false-negative interpretations at digital breast tomosynthesis in the prospective Oslo Tomosynthesis Screening Trial (OTST) using independent double reading
Objectives: To analyze discordant and false-negatives of double reading digital breast tomosynthesis (DBT) versus digital mammography (DM) including reading times in the Oslo Tomosynthesis Screening Trial (OTST), and reclassify these in a retrospective reader study as missed, minimal sign, or true-negatives. Methods: The prospective OTST comparing double reading DBT vs. DM had paired design with four parallel arms: DM, DM + computer aided detection, DBT + DM, and DBT + synthetic mammography. Eight radiologists interpreted images in batches using a 5-point scale. Reading time was automatically recorded. A retrospective reader study including four radiologists classified screen-detected cancers with at least one false-negative score and screening examinations of interval cancers as negative, non-specific minimal sign, significant minimal sign, and missed; the two latter groups are defined “actionable.” Statistics included chi-square, Fisher’s exact, McNemar’s, and Mann–Whitney U tests. Results: Discordant rate (cancer missed by one reader) for screen-detected cancers was overall comparable (DBT (31% [71/227]) and DM (30% [52/175]), p = .81), significantly lower at DBT for spiculated cancers (DBT, 19% [20/106] vs. DM, 36% [38/106], p = .003), but high (28/49 = 57%, p = 0.001) for DBT-only detected spiculated cancers. Reading time and sensitivity varied among readers. False-negative DBT-only detected spiculated cancers had shorter reading time than true-negatives in 46% (13/28). Retrospective evaluation classified the following DBT exams “actionable”: three missed by both readers, 95% (39/41) of discordant cancers detected by both modes, all 30 discordant DBT-only cancers, 25% (13/51) of interval cancers. Conclusions: Discordant rate was overall comparable for DBT and DM, significantly lower at DBT for spiculated cancers, but high for DBT-only detected spiculated lesions. Most false-negative screen-detected DBT were classified as “actionable.” Clinical relevance statement: Retrospective evaluation of false-negative interpretations from the Oslo Tomosynthesis Screening Trial shows that most discordant and several interval cancers could have been detected at screening. This underlines the potential for modern AI-based reading aids and triage, as high-volume screening is a demanding task. Key Points: • Digital breast tomosynthesis (DBT) screening is more sensitive and has higher specificity compared to digital mammography screening, but high-volume DBT screening is a demanding task which can result in high discordance rate among readers. • Independent double reading DBT screening had overall comparable discordance rate as digital mammography, lower for spiculated masses seen on both modalities, and higher for small spiculated cancer seen only on DBT. • Almost all discordant digital breast tomosynthesis-detected cancers (72 of 74) and 25% (13 of 51) of the interval cancers in the Oslo Tomosynthesis Screening Trial were retrospectively classified as actionable and could have been detected by the readers.
- 8 November 2023
- Published by Springer Nature in European Radiology
- Vol. 34 (6) , 3912-3923
Open AccessDiscordant and false-negative interpretations at digital breast tomosynthesis in the prospective Oslo Tomosynthesis Screening Trial (OTST) using independent double reading
Objectives: To analyze discordant and false-negatives of double reading digital breast tomosynthesis (DBT) versus digital mammography (DM) including reading times in the Oslo Tomosynthesis Screening Trial (OTST), and reclassify these in a retrospective reader study as missed, minimal sign, or true-negatives. Methods: The prospective OTST comparing double reading DBT vs. DM had paired design with four parallel arms: DM, DM + computer aided detection, DBT + DM, and DBT + synthetic mammography. Eight radiologists interpreted images in batches using a 5-point scale. Reading time was automatically recorded. A retrospective reader study including four radiologists classified screen-detected cancers with at least one false-negative score and screening examinations of interval cancers as negative, non-specific minimal sign, significant minimal sign, and missed; the two latter groups are defined “actionable.” Statistics included chi-square, Fisher’s exact, McNemar’s, and Mann–Whitney U tests. Results: Discordant rate (cancer missed by one reader) for screen-detected cancers was overall comparable (DBT (31% [71/227]) and DM (30% [52/175]), p = .81), significantly lower at DBT for spiculated cancers (DBT, 19% [20/106] vs. DM, 36% [38/106], p = .003), but high (28/49 = 57%, p = 0.001) for DBT-only detected spiculated cancers. Reading time and sensitivity varied among readers. False-negative DBT-only detected spiculated cancers had shorter reading time than true-negatives in 46% (13/28). Retrospective evaluation classified the following DBT exams “actionable”: three missed by both readers, 95% (39/41) of discordant cancers detected by both modes, all 30 discordant DBT-only cancers, 25% (13/51) of interval cancers. Conclusions: Discordant rate was overall comparable for DBT and DM, significantly lower at DBT for spiculated cancers, but high for DBT-only detected spiculated lesions. Most false-negative screen-detected DBT were classified as “actionable.” Clinical relevance statement: Retrospective evaluation of false-negative interpretations from the Oslo Tomosynthesis Screening Trial shows that most discordant and several interval cancers could have been detected at screening. This underlines the potential for modern AI-based reading aids and triage, as high-volume screening is a demanding task. Key Points: • Digital breast tomosynthesis (DBT) screening is more sensitive and has higher specificity compared to digital mammography screening, but high-volume DBT screening is a demanding task which can result in high discordance rate among readers. • Independent double reading DBT screening had overall comparable discordance rate as digital mammography, lower for spiculated masses seen on both modalities, and higher for small spiculated cancer seen only on DBT. • Almost all discordant digital breast tomosynthesis-detected cancers (72 of 74) and 25% (13 of 51) of the interval cancers in the Oslo Tomosynthesis Screening Trial were retrospectively classified as actionable and could have been detected by the readers.
- Open Access
- 29 September 2023
- Published by Springer Nature in Pediatric Radiology
- Vol. 53 (12) , 2502-2514
Use of ionizing radiation in a Norwegian cohort of children with congenital heart disease: imaging frequency and radiation dose for the Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) study
Background: The European-funded Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) project is a multicenter cohort study assessing the long-term effects of ionizing radiation in patients with congenital heart disease. Knowledge is lacking regarding the use of ionizing radiation from sources other than cardiac catheterization in this cohort. Objective: This study aims to assess imaging frequency and radiation dose (excluding cardiac catheterization) to patients from a single center participating in the Norwegian HARMONIC project. Materials and methods: Between 2000 and 2020, we recruited 3,609 patients treated for congenital heart disease (age < 18 years), with 33,768 examinations categorized by modality and body region. Data were retrieved from the radiology information system. Effective doses were estimated using International Commission on Radiological Protection Publication 60 conversion factors, and the analysis was stratified into six age categories: newborn; 1 year, 5 years, 10 years, 15 years, and late adolescence. Results: The examination distribution was as follows: 91.0% conventional radiography, 4.0% computed tomography (CT), 3.6% diagnostic fluoroscopy, 1.2% nuclear medicine, and 0.3% noncardiac intervention. In the newborn to 15 years age categories, 4–12% had ≥ ten conventional radiography studies, 1–8% underwent CT, and 0.3–2.5% received nuclear medicine examinations. The median effective dose ranged from 0.008–0.02 mSv and from 0.76–3.47 mSv for thoracic conventional radiography and thoracic CT, respectively. The total effective dose burden from thoracic conventional radiography ranged between 28–65% of the dose burden from thoracic CT in various age categories (40% for all ages combined). The median effective dose for nuclear medicine lung perfusion was 0.6–0.86 mSv and for gastrointestinal fluoroscopy 0.17–0.27 mSv. Because of their low frequency, these procedures contributed less to the total effective dose than thoracic radiography. Conclusion: This study shows that CT made the largest contribution to the radiation dose from imaging (excluding cardiac intervention). However, although the dose per conventional radiograph was low, the large number of examinations resulted in a substantial total effective dose. Therefore, it is important to consider the frequency of conventional radiography while calculating cumulative dose for individuals. The findings of this study will help the HARMONIC project to improve risk assessment by minimizing the uncertainty associated with cumulative dose calculations. Graphical
- 29 September 2023
- Published by Springer Nature in Pediatric Radiology
- Vol. 53 (12) , 2502-2514
Open AccessUse of ionizing radiation in a Norwegian cohort of children with congenital heart disease: imaging frequency and radiation dose for the Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) study
Background: The European-funded Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics (HARMONIC) project is a multicenter cohort study assessing the long-term effects of ionizing radiation in patients with congenital heart disease. Knowledge is lacking regarding the use of ionizing radiation from sources other than cardiac catheterization in this cohort. Objective: This study aims to assess imaging frequency and radiation dose (excluding cardiac catheterization) to patients from a single center participating in the Norwegian HARMONIC project. Materials and methods: Between 2000 and 2020, we recruited 3,609 patients treated for congenital heart disease (age < 18 years), with 33,768 examinations categorized by modality and body region. Data were retrieved from the radiology information system. Effective doses were estimated using International Commission on Radiological Protection Publication 60 conversion factors, and the analysis was stratified into six age categories: newborn; 1 year, 5 years, 10 years, 15 years, and late adolescence. Results: The examination distribution was as follows: 91.0% conventional radiography, 4.0% computed tomography (CT), 3.6% diagnostic fluoroscopy, 1.2% nuclear medicine, and 0.3% noncardiac intervention. In the newborn to 15 years age categories, 4–12% had ≥ ten conventional radiography studies, 1–8% underwent CT, and 0.3–2.5% received nuclear medicine examinations. The median effective dose ranged from 0.008–0.02 mSv and from 0.76–3.47 mSv for thoracic conventional radiography and thoracic CT, respectively. The total effective dose burden from thoracic conventional radiography ranged between 28–65% of the dose burden from thoracic CT in various age categories (40% for all ages combined). The median effective dose for nuclear medicine lung perfusion was 0.6–0.86 mSv and for gastrointestinal fluoroscopy 0.17–0.27 mSv. Because of their low frequency, these procedures contributed less to the total effective dose than thoracic radiography. Conclusion: This study shows that CT made the largest contribution to the radiation dose from imaging (excluding cardiac intervention). However, although the dose per conventional radiograph was low, the large number of examinations resulted in a substantial total effective dose. Therefore, it is important to consider the frequency of conventional radiography while calculating cumulative dose for individuals. The findings of this study will help the HARMONIC project to improve risk assessment by minimizing the uncertainty associated with cumulative dose calculations. Graphical
- 1 October 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 293 (1) , 60-68
Digital Mammography versus Breast Tomosynthesis: Impact of Breast Density on Diagnostic Performance in Population-based Screening
BackgroundPrevious studies comparing digital breast tomosynthesis (DBT) to digital mammography (DM) have shown conflicting results regarding breast density and diagnostic performance.PurposeTo compare true-positive and false-positive interpretations in DM versus DBT according to volumetric density, age, and mammographic findings.Materials and MethodsFrom November 2010 to December 2012, 24 301 women aged 50-69 years (mean age, 59.1 years ± 5.7) were prospectively included in the Oslo Tomosynthesis Screening Trial. Participants received same-compression DM and DBT with independent double reading for both DM and DM plus DBT reading modes. Eight experienced radiologists rated the images by using a five-point scale for probability of malignancy. Participants were followed up for 2 years to assess for interval cancers. Breast density was assessed by using automatic volumetric software (scale, 1-4). Differences in true-positive rates, false-positive rates, and mammographic findings were assessed by using confidence intervals (Newcombe paired method) and P values (McNemar and χ2 tests).ResultsThe true-positive rate of DBT was higher than that of DM for density groups (range, 12%-24%; P < .001 for density scores of 2 and 3, and P > .05 for density scores of 1 and 4) and age groups (range, 15%-35%; P < .05 for all age groups), mainly due to the higher number of spiculated masses and architectural distortions found at DBT (P < .001 for density scores of 2 and 3; P < .05 for women aged 55-69 years). The false-positive rate was lower for DBT than for DM in all age groups (range, -0.6% to -1.2%; P < .01) and density groups (range, -0.7 to -1.0%; P < .005) owing to fewer asymmetric densities (P ≤ .001), except for extremely dense breasts (0.1%, P = .82).ConclusionDigital breast tomosynthesis enabled the detection of more cancers in all density and age groups compared with digital mammography, especially cancers classified as spiculated masses and architectural distortions. The improvement in cancer detection rate showed a positive correlation with age. With use of digital breast tomosynthesis, false-positive findings were lower due to fewer asymmetric densities, except in extremely dense breasts.© RSNA, 2019Online supplemental material is available for this article.See also the editorial by Fuchsjäger and Adelsmayr in this issue.
- 1 October 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 293 (1) , 60-68
Digital Mammography versus Breast Tomosynthesis: Impact of Breast Density on Diagnostic Performance in Population-based Screening
BackgroundPrevious studies comparing digital breast tomosynthesis (DBT) to digital mammography (DM) have shown conflicting results regarding breast density and diagnostic performance.PurposeTo compare true-positive and false-positive interpretations in DM versus DBT according to volumetric density, age, and mammographic findings.Materials and MethodsFrom November 2010 to December 2012, 24 301 women aged 50-69 years (mean age, 59.1 years ± 5.7) were prospectively included in the Oslo Tomosynthesis Screening Trial. Participants received same-compression DM and DBT with independent double reading for both DM and DM plus DBT reading modes. Eight experienced radiologists rated the images by using a five-point scale for probability of malignancy. Participants were followed up for 2 years to assess for interval cancers. Breast density was assessed by using automatic volumetric software (scale, 1-4). Differences in true-positive rates, false-positive rates, and mammographic findings were assessed by using confidence intervals (Newcombe paired method) and P values (McNemar and χ2 tests).ResultsThe true-positive rate of DBT was higher than that of DM for density groups (range, 12%-24%; P < .001 for density scores of 2 and 3, and P > .05 for density scores of 1 and 4) and age groups (range, 15%-35%; P < .05 for all age groups), mainly due to the higher number of spiculated masses and architectural distortions found at DBT (P < .001 for density scores of 2 and 3; P < .05 for women aged 55-69 years). The false-positive rate was lower for DBT than for DM in all age groups (range, -0.6% to -1.2%; P < .01) and density groups (range, -0.7 to -1.0%; P < .005) owing to fewer asymmetric densities (P ≤ .001), except for extremely dense breasts (0.1%, P = .82).ConclusionDigital breast tomosynthesis enabled the detection of more cancers in all density and age groups compared with digital mammography, especially cancers classified as spiculated masses and architectural distortions. The improvement in cancer detection rate showed a positive correlation with age. With use of digital breast tomosynthesis, false-positive findings were lower due to fewer asymmetric densities, except in extremely dense breasts.© RSNA, 2019Online supplemental material is available for this article.See also the editorial by Fuchsjäger and Adelsmayr in this issue.
- 1 April 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 291 (1) , 23-30
Digital Mammography versus Digital Mammography Plus Tomosynthesis in Breast Cancer Screening: The Oslo Tomosynthesis Screening Trial
Background Digital breast tomosynthesis (DBT) is replacing digital mammography (DM) in the clinical workflow. Currently, there are limited prospective studies comparing the diagnostic accuracy of both examinations and the role of synthetic mammography (SM) and computer-aided detection (CAD). Purpose To compare the accuracy of DM versus DM + DBT in population-based breast cancer screening. Materials and Methods This prospective study, performed from November 2010 to December 2012, included 24 301 women (mean age, 59.1 years ± 5.7 [standard deviation]) with 281 cancers, of which 51 were interval cancers. Each examination was independently interpreted with four reading modes: DM, DM + CAD, DM + DBT, and SM + DBT. Sensitivity and specificity were compared for DM versus DM + DBT, DM versus DM + CAD, DM + DBT versus SM + DBT, and DM versus DM + DBT at double reading. Reader-adjusted performance characteristics of reading modes were evaluated on the basis of pre-arbitration (initial interpretation) scores. Statistical analysis was based on cluster bootstrap analysis using 10 000 random resamples. Results Sensitivity was 54.1% (152 of 281) for DM and 70.5% (198 of 281) for DM + DBT. Reader-adjusted difference was 12.6% (95% confidence interval [CI]: 5.2%, 19.7%; P = .001). Specificity was 94.2% (false-positive fraction [FPF], 5.8%; 1388 of 24 020) for DM and 95.0% (FPF, 5.0%; 1209/24 020) for DM + DBT, with a reader-adjusted difference in FPF of -1.2% (95% CI: -1.7%, -0.7%; P < .001). Sensitivity was 69.0% (194 of 281) for SM + DBT and 70.5% (198 of 281) for DM + DBT, with a reader-adjusted difference of 1.0% (95% CI: -6.2%, 8.5%; P = .77). Specificity was 95.4% (FPF, 4.6%; 1111 of 24 020) for SM + DBT and 95.0% (FPF, 5.0%;1209 of 24 020) for DM + DBT, with reader-adjusted 95% CIs for FPF of 4.7%, 5.4% and 5.0%, 5.7%, respectively, and a difference of -0.3% (95% CI: -0.8%, 0.2%; P = .23). Differences in sensitivity and specificity with the addition of CAD were small and not significant (P > .2). Conclusion Addition of digital breast tomosynthesis to digital mammography resulted in significant gains in sensitivity and specificity. Synthetic mammography in combination with digital breast tomosynthesis had similar sensitivity and specificity to digital mammography in combination with digital breast tomosynthesis. © RSNA, 2019 See also the editorial by Lång in this issue.
- 1 April 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 291 (1) , 23-30
Digital Mammography versus Digital Mammography Plus Tomosynthesis in Breast Cancer Screening: The Oslo Tomosynthesis Screening Trial
Background Digital breast tomosynthesis (DBT) is replacing digital mammography (DM) in the clinical workflow. Currently, there are limited prospective studies comparing the diagnostic accuracy of both examinations and the role of synthetic mammography (SM) and computer-aided detection (CAD). Purpose To compare the accuracy of DM versus DM + DBT in population-based breast cancer screening. Materials and Methods This prospective study, performed from November 2010 to December 2012, included 24 301 women (mean age, 59.1 years ± 5.7 [standard deviation]) with 281 cancers, of which 51 were interval cancers. Each examination was independently interpreted with four reading modes: DM, DM + CAD, DM + DBT, and SM + DBT. Sensitivity and specificity were compared for DM versus DM + DBT, DM versus DM + CAD, DM + DBT versus SM + DBT, and DM versus DM + DBT at double reading. Reader-adjusted performance characteristics of reading modes were evaluated on the basis of pre-arbitration (initial interpretation) scores. Statistical analysis was based on cluster bootstrap analysis using 10 000 random resamples. Results Sensitivity was 54.1% (152 of 281) for DM and 70.5% (198 of 281) for DM + DBT. Reader-adjusted difference was 12.6% (95% confidence interval [CI]: 5.2%, 19.7%; P = .001). Specificity was 94.2% (false-positive fraction [FPF], 5.8%; 1388 of 24 020) for DM and 95.0% (FPF, 5.0%; 1209/24 020) for DM + DBT, with a reader-adjusted difference in FPF of -1.2% (95% CI: -1.7%, -0.7%; P < .001). Sensitivity was 69.0% (194 of 281) for SM + DBT and 70.5% (198 of 281) for DM + DBT, with a reader-adjusted difference of 1.0% (95% CI: -6.2%, 8.5%; P = .77). Specificity was 95.4% (FPF, 4.6%; 1111 of 24 020) for SM + DBT and 95.0% (FPF, 5.0%;1209 of 24 020) for DM + DBT, with reader-adjusted 95% CIs for FPF of 4.7%, 5.4% and 5.0%, 5.7%, respectively, and a difference of -0.3% (95% CI: -0.8%, 0.2%; P = .23). Differences in sensitivity and specificity with the addition of CAD were small and not significant (P > .2). Conclusion Addition of digital breast tomosynthesis to digital mammography resulted in significant gains in sensitivity and specificity. Synthetic mammography in combination with digital breast tomosynthesis had similar sensitivity and specificity to digital mammography in combination with digital breast tomosynthesis. © RSNA, 2019 See also the editorial by Lång in this issue.
- 1 April 2018
- Published by Elsevier in Academic Radiology
- Vol. 25 (4) , 509-518
Quantitative Measurements Versus Receiver Operating Characteristics and Visual Grading Regression in CT Images Reconstructed with Iterative Reconstruction
- 1 April 2018
- Published by Elsevier in Academic Radiology
- Vol. 25 (4) , 509-518
Quantitative Measurements Versus Receiver Operating Characteristics and Visual Grading Regression in CT Images Reconstructed with Iterative Reconstruction
- 10 February 2018
- Published by Springer Nature in Breast Cancer Research and Treatment
- Vol. 169 (3) , 489-496
Performance of breast cancer screening using digital breast tomosynthesis: results from the prospective population-based Oslo Tomosynthesis Screening Trial
Purpose Digital breast tomosynthesis (DBT) has the potential to overcome limitations of conventional mammography. This study investigated the effects of addition of DBT on interval and detected cancers in population-based screening. Methods Oslo Tomosynthesis Screening Trial (OTST) was a prospective, independent double-reading trial inviting women 50–69 years biennially, comparing full-field digital mammography (FFDM) plus DBT with FFDM alone. Performance indicators and characteristics of screen-detected and interval cancers were compared with two previous FFDM rounds. Results 24,301 consenting women underwent FFDM + DBT screening over a 2-year period. Results were compared with 59,877 FFDM examinations during prior rounds. Addition of DBT resulted in a non-significant increase in sensitivity (76.2%, 378/496, vs. 80.8%, 227/281, p = 0.151) and a significant increase in specificity (96.4%, 57229/59381 vs. 97.5%, 23427/24020, p < .001). Number of recalls per screen-detected cancer decreased from 6.7 (2530/378) to 3.6 (820/227) with DBT (p < .001). Cancer detection per 1000 women screened increased (6.3, 378/59877, vs. 9.3, 227/24301, p < .001). Interval cancer rate per 1000 screens for FFDM + DBT remained similar to previous FFDM rounds (2.1, 51/24301 vs. 2.0, 118/59877, p = 0.734). Interval cancers post-DBT were comparable to prior rounds but significantly different in size, grade, and node status from cancers detected only using DBT. 39.6% (19/48) of interval cancers had positive nodes compared with only 3.9% (2/51) of additional DBT-only-detected cancers. Conclusions DBT-supplemented screening resulted in significant increases in screen-detected cancers and specificity. However, no significant change was observed in the rate, size, node status, or grade of interval cancers. ClinicalTrials.gov: NCT01248546.
- 10 February 2018
- Published by Springer Nature in Breast Cancer Research and Treatment
- Vol. 169 (3) , 489-496
Performance of breast cancer screening using digital breast tomosynthesis: results from the prospective population-based Oslo Tomosynthesis Screening Trial
Purpose Digital breast tomosynthesis (DBT) has the potential to overcome limitations of conventional mammography. This study investigated the effects of addition of DBT on interval and detected cancers in population-based screening. Methods Oslo Tomosynthesis Screening Trial (OTST) was a prospective, independent double-reading trial inviting women 50–69 years biennially, comparing full-field digital mammography (FFDM) plus DBT with FFDM alone. Performance indicators and characteristics of screen-detected and interval cancers were compared with two previous FFDM rounds. Results 24,301 consenting women underwent FFDM + DBT screening over a 2-year period. Results were compared with 59,877 FFDM examinations during prior rounds. Addition of DBT resulted in a non-significant increase in sensitivity (76.2%, 378/496, vs. 80.8%, 227/281, p = 0.151) and a significant increase in specificity (96.4%, 57229/59381 vs. 97.5%, 23427/24020, p < .001). Number of recalls per screen-detected cancer decreased from 6.7 (2530/378) to 3.6 (820/227) with DBT (p < .001). Cancer detection per 1000 women screened increased (6.3, 378/59877, vs. 9.3, 227/24301, p < .001). Interval cancer rate per 1000 screens for FFDM + DBT remained similar to previous FFDM rounds (2.1, 51/24301 vs. 2.0, 118/59877, p = 0.734). Interval cancers post-DBT were comparable to prior rounds but significantly different in size, grade, and node status from cancers detected only using DBT. 39.6% (19/48) of interval cancers had positive nodes compared with only 3.9% (2/51) of additional DBT-only-detected cancers. Conclusions DBT-supplemented screening resulted in significant increases in screen-detected cancers and specificity. However, no significant change was observed in the rate, size, node status, or grade of interval cancers. ClinicalTrials.gov: NCT01248546.
- 25 January 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (3) , 035006
Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality
The main purpose was to compare average glandular dose (AGD) for same-compression digital mammography (DM) and digital breast tomosynthesis (DBT) acquisitions in a population based screening program, with and without breast density stratification, as determined by automatically calculated breast density (Quantra ™ ). Secondary, to compare AGD estimates based on measured breast density, air kerma and half value layer (HVL) to DICOM metadata based estimates. AGD was estimated for 3819 women participating in the screening trial. All received craniocaudal and mediolateral oblique views of each breasts with paired DM and DBT acquisitions. Exposure parameters were extracted from DICOM metadata. Air kerma and HVL were measured for all beam qualities used to acquire the mammograms. Volumetric breast density was estimated using Quantra ™ . AGD was estimated using the Dance model. AGD reported directly from the DICOM metadata was also assessed. Mean AGD was 1.74 and 2.10 mGy for DM and DBT, respectively. Mean DBT/DM AGD ratio was 1.24. For fatty breasts: mean AGD was 1.74 and 2.27 mGy for DM and DBT, respectively. For dense breasts: mean AGD was 1.73 and 1.79 mGy, for DM and DBT, respectively. For breasts of similar thickness, dense breasts had higher AGD for DM and similar AGD for DBT. The DBT/DM dose ratio was substantially lower for dense compared to fatty breasts (1.08 versus 1.33). The average c -factor was 1.16. Using previously published polynomials to estimate glandularity from thickness underestimated the c -factor by 5.9% on average. Mean AGD error between estimates based on measurements (air kerma and HVL) versus DICOM header data was 3.8%, but for one mammography unit as high as 7.9%. Mean error of using the AGD value reported in the DICOM header was 10.7 and 13.3%, respectively. Thus, measurement of breast density, radiation dose and beam quality can substantially affect AGD estimates.
- 25 January 2018
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (3) , 035006
Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality
The main purpose was to compare average glandular dose (AGD) for same-compression digital mammography (DM) and digital breast tomosynthesis (DBT) acquisitions in a population based screening program, with and without breast density stratification, as determined by automatically calculated breast density (Quantra ™ ). Secondary, to compare AGD estimates based on measured breast density, air kerma and half value layer (HVL) to DICOM metadata based estimates. AGD was estimated for 3819 women participating in the screening trial. All received craniocaudal and mediolateral oblique views of each breasts with paired DM and DBT acquisitions. Exposure parameters were extracted from DICOM metadata. Air kerma and HVL were measured for all beam qualities used to acquire the mammograms. Volumetric breast density was estimated using Quantra ™ . AGD was estimated using the Dance model. AGD reported directly from the DICOM metadata was also assessed. Mean AGD was 1.74 and 2.10 mGy for DM and DBT, respectively. Mean DBT/DM AGD ratio was 1.24. For fatty breasts: mean AGD was 1.74 and 2.27 mGy for DM and DBT, respectively. For dense breasts: mean AGD was 1.73 and 1.79 mGy, for DM and DBT, respectively. For breasts of similar thickness, dense breasts had higher AGD for DM and similar AGD for DBT. The DBT/DM dose ratio was substantially lower for dense compared to fatty breasts (1.08 versus 1.33). The average c -factor was 1.16. Using previously published polynomials to estimate glandularity from thickness underestimated the c -factor by 5.9% on average. Mean AGD error between estimates based on measurements (air kerma and HVL) versus DICOM header data was 3.8%, but for one mammography unit as high as 7.9%. Mean error of using the AGD value reported in the DICOM header was 10.7 and 13.3%, respectively. Thus, measurement of breast density, radiation dose and beam quality can substantially affect AGD estimates.
- Open Access
- 22 November 2016
- Published by Norwegian Medical Association in Tidsskrift for Den norske legeforening
- Vol. 136 (21) , 1809-12
Strålingsindusert katarakt
Klinisk oversikt - Strålevernforskriftens dosegrense til øyelinsen for yrkeseksponerte er basert på utdaterte terskeldoser for strålingsindusert katarakt.
- 22 November 2016
- Published by Norwegian Medical Association in Tidsskrift for Den norske legeforening
- Vol. 136 (21) , 1809-12
Open AccessStrålingsindusert katarakt
Klinisk oversikt - Strålevernforskriftens dosegrense til øyelinsen for yrkeseksponerte er basert på utdaterte terskeldoser for strålingsindusert katarakt.
- Open Access
- 17 August 2016
- Published by SAGE Publications in Acta Radiologica Open
- Vol. 5 (8)
Can use of adaptive statistical iterative reconstruction reduce radiation dose in unenhanced head CT? An analysis of qualitative and quantitative image quality
Background: Iterative reconstruction can reduce image noise and thereby facilitate dose reduction. Purpose: To evaluate qualitative and quantitative image quality for full dose and dose reduced head computed tomography (CT) protocols reconstructed using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR). Material and Methods: Fourteen patients undergoing follow-up head CT were included. All patients underwent full dose (FD) exam and subsequent 15% dose reduced (DR) exam, reconstructed using FBP and 30% ASIR. Qualitative image quality was assessed using visual grading characteristics. Quantitative image quality was assessed using ROI measurements in cerebrospinal fluid (CSF), white matter, peripheral and central gray matter. Additionally, quantitative image quality was measured in Catphan and vendor’s water phantom. Results: There was no significant difference in qualitative image quality between FD FBP and DR ASIR. Comparing same scan FBP versus ASIR, a noise reduction of 28.6% in CSF and between −3.7 and 3.5% in brain parenchyma was observed. Comparing FD FBP versus DR ASIR, a noise reduction of 25.7% in CSF, and −7.5 and 6.3% in brain parenchyma was observed. Image contrast increased in ASIR reconstructions. Contrast-to-noise ratio was improved in DR ASIR compared to FD FBP. In phantoms, noise reduction was in the range of 3 to 28% with image content. Conclusion: There was no significant difference in qualitative image quality between full dose FBP and dose reduced ASIR. CNR improved in DR ASIR compared to FD FBP mostly due to increased contrast, not reduced noise. Therefore, we recommend using caution if reducing dose and applying ASIR to maintain image quality.
- 17 August 2016
- Published by SAGE Publications in Acta Radiologica Open
- Vol. 5 (8)
Open AccessCan use of adaptive statistical iterative reconstruction reduce radiation dose in unenhanced head CT? An analysis of qualitative and quantitative image quality
Background: Iterative reconstruction can reduce image noise and thereby facilitate dose reduction. Purpose: To evaluate qualitative and quantitative image quality for full dose and dose reduced head computed tomography (CT) protocols reconstructed using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR). Material and Methods: Fourteen patients undergoing follow-up head CT were included. All patients underwent full dose (FD) exam and subsequent 15% dose reduced (DR) exam, reconstructed using FBP and 30% ASIR. Qualitative image quality was assessed using visual grading characteristics. Quantitative image quality was assessed using ROI measurements in cerebrospinal fluid (CSF), white matter, peripheral and central gray matter. Additionally, quantitative image quality was measured in Catphan and vendor’s water phantom. Results: There was no significant difference in qualitative image quality between FD FBP and DR ASIR. Comparing same scan FBP versus ASIR, a noise reduction of 28.6% in CSF and between −3.7 and 3.5% in brain parenchyma was observed. Comparing FD FBP versus DR ASIR, a noise reduction of 25.7% in CSF, and −7.5 and 6.3% in brain parenchyma was observed. Image contrast increased in ASIR reconstructions. Contrast-to-noise ratio was improved in DR ASIR compared to FD FBP. In phantoms, noise reduction was in the range of 3 to 28% with image content. Conclusion: There was no significant difference in qualitative image quality between full dose FBP and dose reduced ASIR. CNR improved in DR ASIR compared to FD FBP mostly due to increased contrast, not reduced noise. Therefore, we recommend using caution if reducing dose and applying ASIR to maintain image quality.