Romain Didier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Romain Didier has a total of 286 co-authors. Here are the top co-authors by number of shared publications:
Martine Gilard
INSERM UMR1304-GETBO, University of Brest, 29200 Brest, France; Cardiology Department, CHU Brest, 292003 Brest, France
11 shared publications- Martine Gilard
University Hospital of Brest, Brest, France
7 shared publications Edward Koifman
Soroka Medical Center, Ben-Gurion University of The Negev, Beer Sheva, Israel, Israel
4 shared publications- Eric Durand
Department of Cardiology, Université Rouen Normandie, Inserm U1096, CHU Rouen , Rouen
4 shared publications - Guillaume Leurent
Rennes University Hospital, Cardiology Department, INSERM, LTSI-UMR 1099, Rennes University , 2 rue Henri le Guilloux, 35000 Rennes
4 shared publications - Martine Gilard
Department of Cardiology, Brest University Hospital, Brest, France
4 shared publications
Latest Publications
- Open Access
- 15 January 2026
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 119 (1) , 12-14
France TAVI: The odyssey
- 15 January 2026
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 119 (1) , 12-14
Open AccessFrance TAVI: The odyssey
- 9 September 2025
- Published by Wolters Kluwer Health in Circulation
- Vol. 152 (10) , 639-657
Transcatheter Aortic Valve Replacement With Balloon- Versus Self-Expandable Bioprostheses for the Treatment of Bicuspid Aortic Valve Stenosis
BACKGROUND: Differences between balloon- and self-expandable transcatheter heart valves (BE-THVs and SE-THVs, respectively) may influence the outcomes of transcatheter aortic valve replacement for bicuspid aortic valve (BAV) stenosis. METHODS: Consecutive patients undergoing transcatheter aortic valve replacement with BE-THV or SE-THV for computed tomography–diagnosed bicuspid aortic valve stenosis at 29 centers were included. The primary outcome was death or stroke. After propensity score matching in 10 data sets generated by multiple imputation, outcomes from transcatheter aortic valve replacement to 3-year follow-up were computed by multivariable binomial logistic mixed-effects models, multivariable linear mixed-effects models, or multivariable frailty models accounting for center-related influences and residual confounding effects (doubly robust adjustment). The results were replicated by inverse probability of treatment weighting and multivariable adjustment. RESULTS: A total of 1443 consecutive patients with bicuspid aortic valve stenosis undergoing BE-THV (n=860) or SE-THV (n=583) implantation were included. In-hospital and 30-day death or stroke did not significantly differ between BE-THV and SE-THV groups (5.1% versus 6.1%; hazard ratio after propensity score matching, 1.02 [95% CI, 0.51–2.02]). BE-THV implantation was associated with higher annulus rupture and mean transvalvular gradient compared with SE-THV implantation. In contrast, SE-THV implantation was associated with higher additional valve implantation and paravalvular regurgitation compared with BE-THV implantation. The results were consistent across the statistical methods used and between early- and new-generation THVs. At 30 days, pacemaker implantation was lower in the BE-THV group compared with the SE-THV group (11.9% versus 18.6%; hazard ratio after propensity score matching, 0.58 [95% CI, 0.36–0.93]). This result did not depend on the statistical method used. At 3 years, consistent with the 1- and 2-year analyses, death or stroke was not significantly different between the BE-THV and SE-THV groups (23.7% versus 26.2%; hazard ratio after propensity score matching, 0.99 [95% CI, 0.65–1.51]). Death or stroke across major clinical, anatomical, functional, and procedural conditions was consistent with the main analysis. After inverse probability of treatment weighting and multivariable adjustment, these conclusions remained unchanged. CONCLUSIONS: In patients undergoing transcatheter aortic valve replacement for bicuspid aortic valve stenosis, death or stroke does not significantly differ between those receiving a BE-THV and those receiving an SE-THV over a follow-up of 3 years. BE-THV is associated with higher transvalvular mean gradient and more frequent annulus rupture, whereas SE-THV is associated with more frequent moderate to severe aortic regurgitation, additional THV implantation, and permanent pacemaker implantation.
- 9 September 2025
- Published by Wolters Kluwer Health in Circulation
- Vol. 152 (10) , 639-657
Transcatheter Aortic Valve Replacement With Balloon- Versus Self-Expandable Bioprostheses for the Treatment of Bicuspid Aortic Valve Stenosis
BACKGROUND: Differences between balloon- and self-expandable transcatheter heart valves (BE-THVs and SE-THVs, respectively) may influence the outcomes of transcatheter aortic valve replacement for bicuspid aortic valve (BAV) stenosis. METHODS: Consecutive patients undergoing transcatheter aortic valve replacement with BE-THV or SE-THV for computed tomography–diagnosed bicuspid aortic valve stenosis at 29 centers were included. The primary outcome was death or stroke. After propensity score matching in 10 data sets generated by multiple imputation, outcomes from transcatheter aortic valve replacement to 3-year follow-up were computed by multivariable binomial logistic mixed-effects models, multivariable linear mixed-effects models, or multivariable frailty models accounting for center-related influences and residual confounding effects (doubly robust adjustment). The results were replicated by inverse probability of treatment weighting and multivariable adjustment. RESULTS: A total of 1443 consecutive patients with bicuspid aortic valve stenosis undergoing BE-THV (n=860) or SE-THV (n=583) implantation were included. In-hospital and 30-day death or stroke did not significantly differ between BE-THV and SE-THV groups (5.1% versus 6.1%; hazard ratio after propensity score matching, 1.02 [95% CI, 0.51–2.02]). BE-THV implantation was associated with higher annulus rupture and mean transvalvular gradient compared with SE-THV implantation. In contrast, SE-THV implantation was associated with higher additional valve implantation and paravalvular regurgitation compared with BE-THV implantation. The results were consistent across the statistical methods used and between early- and new-generation THVs. At 30 days, pacemaker implantation was lower in the BE-THV group compared with the SE-THV group (11.9% versus 18.6%; hazard ratio after propensity score matching, 0.58 [95% CI, 0.36–0.93]). This result did not depend on the statistical method used. At 3 years, consistent with the 1- and 2-year analyses, death or stroke was not significantly different between the BE-THV and SE-THV groups (23.7% versus 26.2%; hazard ratio after propensity score matching, 0.99 [95% CI, 0.65–1.51]). Death or stroke across major clinical, anatomical, functional, and procedural conditions was consistent with the main analysis. After inverse probability of treatment weighting and multivariable adjustment, these conclusions remained unchanged. CONCLUSIONS: In patients undergoing transcatheter aortic valve replacement for bicuspid aortic valve stenosis, death or stroke does not significantly differ between those receiving a BE-THV and those receiving an SE-THV over a follow-up of 3 years. BE-THV is associated with higher transvalvular mean gradient and more frequent annulus rupture, whereas SE-THV is associated with more frequent moderate to severe aortic regurgitation, additional THV implantation, and permanent pacemaker implantation.
- 15 February 2025
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 118 (5) , 296-303
Assessment of quitting versus using aspirin therapy in patients with stabilized coronary artery disease after stenting who require long-term oral anticoagulation: Rationale for and design of the AQUATIC double-blind randomized trial
- 15 February 2025
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 118 (5) , 296-303
Assessment of quitting versus using aspirin therapy in patients with stabilized coronary artery disease after stenting who require long-term oral anticoagulation: Rationale for and design of the AQUATIC double-blind randomized trial
- Open Access
- 4 February 2025
- Published by Elsevier in JACC: Asia
- Vol. 5 (2) , 255-257
Small Annulus, Big Impact on TAVR Patients?
- 4 February 2025
- Published by Elsevier in JACC: Asia
- Vol. 5 (2) , 255-257
Open AccessSmall Annulus, Big Impact on TAVR Patients?
- 13 February 2024
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 117 (3) , 213-223
Clinical effects of permanent pacemaker implantation after transcatheter aortic valve implantation: Insights from the nationwide FRANCE-TAVI registry
- 13 February 2024
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 117 (3) , 213-223
Clinical effects of permanent pacemaker implantation after transcatheter aortic valve implantation: Insights from the nationwide FRANCE-TAVI registry
- 22 December 2023
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 117 (1) , S74
Clinical effects of permanent pacemaker implantation after transcatheter aortic valve implantation: Insights from the nationwide France TAVI registry
- 22 December 2023
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 117 (1) , S74
Clinical effects of permanent pacemaker implantation after transcatheter aortic valve implantation: Insights from the nationwide France TAVI registry
- 30 June 2022
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 42, 62-63
Timing of Intervention in Patients With Severe Aortic Stenosis: Reading in a Crystal Ball
- 30 June 2022
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 42, 62-63
Timing of Intervention in Patients With Severe Aortic Stenosis: Reading in a Crystal Ball
- 1 March 2022
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 36, 7-8
Early Discharge After Transcatheter Aortic Valve Implantation: Then What?
- 1 March 2022
- Published by Elsevier in Cardiovascular Revascularization Medicine
- Vol. 36, 7-8
Early Discharge After Transcatheter Aortic Valve Implantation: Then What?
- 21 March 2021
- Published by Termedia Sp. z.o.o. in Archives of Medical Science
Comparison of Different Stenting Techniques of Coronary Bifurcation Lesions: A Network Meta-Analysis of 7601 Patients
Introduction: Intervention on coronary bifurcations lesions (CBL) is challenging. While provisional side branch (PS) stenting is the recommended method in most cases, there is no consensus on the preferred 2-stent technique. Material and methods: We performed a network meta-analysis...
- 21 March 2021
- Published by Termedia Sp. z.o.o. in Archives of Medical Science
Comparison of Different Stenting Techniques of Coronary Bifurcation Lesions: A Network Meta-Analysis of 7601 Patients
Introduction: Intervention on coronary bifurcations lesions (CBL) is challenging. While provisional side branch (PS) stenting is the recommended method in most cases, there is no consensus on the preferred 2-stent technique. Material and methods: We performed a network meta-analysis...