MSMutlu Secer

Mutlu Secer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mutlu Secer has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Adaptive Maintenance Management Framework for Steel Truss Bridges Subjected to Climate Change-Induced Corrosion

    by Mutlu Seçer, Ali Alper Saylan

    Climate change modifies environmental exposure conditions and affects the corrosion-driven deterioration of steel bridges, thereby challenging conventional maintenance planning approaches. Thus, more advanced maintenance management strategies are required to address the challenges associated with varying corrosion rate projections. In this study, a novel adaptive maintenance management framework is proposed for steel truss bridges to address climate change-induced corrosion under evolving deterioration conditions. Adaptivity is achieved by updating corrosion rates to consider time-varying deterioration conditions associated with climate change. This enables time-dependent representation of corrosion progression under changing environmental conditions. The framework is demonstrated on a benchmark steel truss bridge and applied to two cities with distinct climate-induced corrosion scenarios to capture spatial variability in environmental exposure conditions. Structural performance objectives are defined in terms of preserving load-carrying capacity and limiting joint displacements to maintain the original design throughout the service life. To achieve an economical maintenance strategy, life cycle cost analyses are conducted for different maintenance alternatives under varying corrosion scenarios, incorporating preventive and essential maintenance actions. In addition, the impact of changes in economic and social indicators, specifically the discount rate and the average daily traffic, on the total cost is evaluated within the proposed adaptive framework. Analysis results reveal that lower discount rates and higher average daily traffic rates significantly increase total costs and amplify the economic consequences of climate change-induced corrosion. The results highlight the importance of integrating scenario-based corrosion evolution into adaptive maintenance frameworks for long-term infrastructure management under climate-driven deterioration conditions.

  • Open Access

    Time-dependent advanced analysis method for steel truss bridges under atmospheric corrosion

    by Mutlu Seçer, Ali Alper Saylan

    Atmospheric corrosion is one of the major factors leading to the deterioration of steel truss bridges. In order to overcome this problem, protective coatings are generally applied to steel members. Since coatings also can deteriorate over time, investigating the time-dependent structural performance becomes essential. In this paper, a method was developed for the time-dependent advanced analysis of steel truss bridges with and without coatings. To achieve this goal, material and geometric nonlinearity were accounted for evaluating the structural load capacity of the bridges, and consequently, the whole structural behavior was monitored. The effect of atmospheric corrosion was modelled using a relationship based on ISO 9224 for members without coating. Besides, two different coating degradation models were applied for the members with coating. For the evaluation of the proposed method, four steel truss bridges from the literature were accounted and time-dependent structural load capacities were calculated under atmospheric corrosion exposure for 100 years. In order to represent the effects of different environments, each steel truss bridge type was assumed to be built in different countries, and atmospheric corrosion data for each case was acquired from international corrosion databases. Numerical analysis results revealed the importance of detrimental atmospheric corrosion effects in terms of structural load capacity in steel truss bridges. In some cases, reductions in structural capacities were significant and even unexpected failures occurred in aggressive environments. Besides, when coatings were applied to steel truss bridges under atmospheric corrosion, a satisfactory delay in the decrease in load-carrying capacity was achieved throughout the structural lifetime.


  • Open Access

    Structural evaluation of selected reinforced concrete buildings within the scope of urban renewal in Izmir province

    by İbRahim Ergin, Mutlu Seçer

    In this study, 160 reinforced concrete buildings located in Izmir, with different numbers of floors and construction years, within the scope of urban renewal between 2013 and 2018, were examined, and their risk status was determined according to the Principles for Identification of Risky Buildings 2013 (RYTEIE 2013). Reinforced concrete buildings were evaluated in detail considering characteristic properties such as concrete compressive strengths, column longitudinal reinforcement ratios, floor weights, ratio of column sectional areas to floor areas, natural vibration periods, ratio of column axial stresses to existing concrete compressive strength, and failure ratios. The structures examined within the scope of the paper were also grouped into two main categories: before and after 1998. In addition, all these buildings were evaluated in terms of Life Safety (LS) performance level with the linear elastic calculation method given in Specification for Structures to be Built in Disaster Areas 2007 (DBYBHY 2007), which was also in force between 2013 and 2018. It is observed that 72% of reinforced concrete buildings were determined as risky buildings according to RYTEIE 2013 and couldn’t provide the LS performance level according to DBYBHY 2007.

  • Numerical Analysis of Flush End-Plate Beam-to-Column Connection using Mathematical Model and Finite Element Analysis

    by Mohammad Haroon Ehsan, Mutlu Seçer

    In the conventional analysis and design of steel structures, beam-to-column connections are generally assumed as entirely rigid or perfectly pinned. This assumption simplifies analysis and design steps and preferred extensively in structural engineering practice. However, experimental studies conducted in recent years have revealed that handling some of the beam-to-column connections as entirely rigid or perfectly pinned does not give realistic results. In fact, most of the connections used in current practice have some certain amount of stiffness which fall between the extreme cases of entirely rigid and perfectly pinned. In order to model the beam-to-column connections properly, several researchers have proposed various mathematical models based on experimental results. In these models, moment rotation relations of beam-to-column connections are defined according to the type of connection. In this study, moment-rotation behaviors of beam-to-column connections formed by flush end-plate are investigated using finite element analysis and a well-known practical mathematical model. Moreover, numerical analysis outcomes were compared with the test results of a reference study from the literature. This paper showed the importance of structural design parameters in determining moment-rotation relationship of flush end-plate type of beam-to-column connections and evaluated the efficiency of the practical numerical models.

  • A Practical Compensation Method for Differential Column Shortenings in High-rise Reinforced Concrete Buildings

    by Mutlu Secer, Amanullah Zamani, Yalcin Isler

    High-rise reinforced concrete buildings have technical, economic and environmental advantages for high density development and they have become a distinctive feature for densely populated urban areas around the world. For this purpose, structural design of high-rise reinforced concrete buildings have become forward and particularly serviceability requirements gained more interest. Differential shortening of vertical members is one of the serviceability requirements; however, only a limited number of studies exist. In this study, a practical compensation method was proposed for the differential shortening of columns and shear walls in high-rise reinforced concrete buildings. In the proposed compensation method, vertical members were grouped and the total error was aimed to be minimized by penalizing the higher shortening differences in the groups to simplify the process of building construction. In order to validate the proposed method, a 32-storey high-rise building that was built in Izmir Turkey was investigated considering both the construction sequence and time-dependent effects as shrinkage and creep. Vertical shortening of columns and shear walls in the tower part of the building were calculated. Uniform-grouped compensation method and the proposed penalized errors compensation method with using L1-norm and L2-norm were applied for differential shortenings of columns and shear walls with considering different numbers of member groups. The magnitude of errors for each compensation method was presented and evaluated. Results of the numerical study reveal that the proposed penalized errors compensation method was capable of determining the compensation errors by minimizing the maximum errors efficiently.


  • Inelastic Ultimate Load Analysis of Steel Frames Considering Lateral Torsional Buckling Under Distributed Loads

    by Mutlu Secer, Ertugrul Turker Uzun

    Contemporary structural design approaches necessitates ways to determine realistic behavior of structures. For this purpose, inelastic ultimate load analysis methods are used widely since strength and stability of whole structure can be represented. In this study, a numerical method is proposed for determining inelastic ultimate load capacity of steel frames considering lateral torsional buckling behavior under distributed loads. In the analyses, inelastic material behavior, second-order effects and residual stresses of the structural frame system and its members are taken into account. Additionally, lateral torsional buckling behavior is considered in the analysis using finite difference method and it is used for determining the structural load carrying capacity of steel frames. Consequently, the problem associated with flexural capacity decreases due to lateral torsional buckling is precisely considered in the load increment steps of inelastic ultimate load analysis. In order to validate the proposed method, numerical examples from the literature are calculated considering the proposed method, AISC 360-16 design specification equations and approaches from the literature. Results of the numerical examples show that lateral torsional buckling is a key issue in determining structural load carrying capacity. Thus, proposed analysis method is shown to be an efficient and consistent tool for inelastic ultimate load analysis.

  • Open Access

    Elastic Lateral Torsional Buckling of Simply Supported Beams under Concentrated Load and Linear Moment Gradient

    by Mutlu Secer, Ertugrul Turker Uzun

    Lateral torsional buckling is a limit state for I-shaped steel beams that may often be a controlling issue in structural steel design. When these members are not appropriately braced so as to prevent lateral deformations and torsion, they are subjected to risk of failure by lateral torsional buckling before reaching their ultimate capacity. This paper investigates elastic lateral torsional buckling of simply supported I-shaped steel beams under concentrated load and linear moment gradient using design standards and codes, approaches from the literature and finite element analysis. Several unbraced member lengths and end moment values are taken into account to compare and evaluate these approaches in terms of elastic critical moment and end moment ratios. Analysis results show that lateral torsional buckling is a crucial stability problem for I-shaped steel members that are under flexure and it is reflected with adequate safety in the design codes and standards considering finite element analysis outcomes.