SDSara Durán

Sara Durán

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sara Durán has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Nanostructured materials for photodynamic therapy: synthesis, characterization and in vitro activity

    by María E. Alea-Reyes, Mafalda Rodrigues, Albert Serrà, Margarita Mora, Maria L. Sagristá, Asensio González, Sara Durán, Marta Duch, José Antonio Plaza, Elisa Vallés, et al.

    Three nanostructured vehicles are proposed as potential carriers for photosensitizers to be used in photodynamic therapy: spherical nanoparticles, hexahedral microparticles and cylindrical magnetic nanorods. A comparative study of their photodynamic properties was performed, and the influence of their size and the amount of loaded porphyrin was considered to discuss their effects in the observed photodynamic activity. All the vehicles have a gold surface, allowing functionalization with a disulfide-containing porphyrin as the photosensitizer, as well as with a PEG-containing thiol to improve their biocompatibility and water solubility. The activity of the porphyrin loaded in each vehicle was assessed through in vitro photocytotoxicity studies using HeLa cells. A synergic effect for the porphyrin toxicity was observed in all of the vehicles. The zinc-containing porphyrin showed better production of singlet oxygen, and proved more photocytotoxic both in solution and loaded in any of the vehicles. The magnetism of the nanorods allows targeting with a magnetic field, but causes their aggregation, hampering the porphyrin's activity. Microparticles showed lower cell internalization but their bigger size allowed a high porphyrin loading, which translated into high photocytotoxicity. The highest cell internalization and photocytotoxicity was observed for the porphyrin-loaded nanoparticles, suggesting that a smaller size is favored in cell uptake.


  • Silicon-nanowire based attachment of silicon chips for mouse embryo labelling

    by S. Durán, S. Novo, M. Duch, R. Gómez-Martínez, M. Fernández-Regúlez, A. San Paulo, C. Nogués, J. Esteve, E. Ibañez, J. A. Plaza

    The adhesion of small silicon chips to cells has many potential applications as direct interconnection of the cells to the external world can be accomplished. Hence, although some typical applications of silicon nanowires integrated into microsystems are focused on achieving a cell-on-a-chip strategy, we are interested in obtaining chip-on-a-cell systems. This paper reports the design, technological development and characterization of polysilicon barcodes featuring silicon nanowires as nanoscale attachment to identify and track living mouse embryos during their in vitro development. The chips are attached to the outer surface of the Zona Pellucida, the cover that surrounds oocytes and embryos, to avoid the direct contact between the chip and the embryo cell membrane. Two attachment methodologies, rolling and pushpin, which allow two entirely different levels of applied forces to attach the chips to living embryos, are evaluated. The former consists of rolling the mouse embryos over one barcode with the silicon nanowires facing upwards, while in the latter, the barcode is pushed against the embryo with a micropipette. The effect on in vitro embryo development and the retention rate related to the calculated applied forces are stated. Field emission scanning electron microscopy inspection, which allowed high-resolution imaging, also confirms the physical attachment of the nanowires with some of them piercing or wrapped by the Zona Pellucida and revealed extraordinary bent silicon nanowires.


  • Open Access

    Technological development of intracellular polysilicon–chromium–gold chips for orthogonal chemical functionalization

    by S. Durán, M. Duch, T. Patiño, A. Torres, O. Penon, R. Gómez-Martínez, L. Barrios, J. Esteve, C. Nogués, L. Pérez-García, et al.


  • Optimized immobilization of lectins using self-assembled monolayers on polysilicon encoded materials for cell tagging

    by Oriol Penon, Dimitrios Siapkas, Sergi Novo, Sara Durán, Gerard Oncins, Abdelhamid Errachid, Lleonard Barrios, Carme Nogués, Marta Duch, José Antonio Plaza, et al.


  • Identification of bovine embryos cultured in groups by attachment of barcodes to the zona pellucida

    by Sergi Novo, Roser Morató, Oriol Penon, Sara Duran, Leonardo Barrios, Carme Nogués, José Antonio Plaza, Luisa Pérez-García, Teresa Mogas, Elena Ibáñez

    The low number of oocytes collected from unstimulated donors by ovum pick-up means that embryos produced from each individual female have to be cultured individually or in very small groups. However, it has been demonstrated that single-embryo culture is less efficient than embryo culture in groups. To overcome this limitation, we developed a direct embryo-tagging system, which allows the collective culture of embryos from different origins whilst preserving their pedigree. Presumptive bovine zygotes were tagged with eight wheat-germ agglutinin biofunctionalised polysilicon barcodes attached to the outer surface of the zona pellucida (ZP). Four different barcodes were used to encode groups of 20–25 embryos, which were then cultured in the same drop. Cleavage, Day-7 and Day-8 blastocysts and barcode retention rates were assessed. In addition, Day-7 blastocysts were vitrified and warmed. Barcode attachment to the ZP of bovine embryos affected neither in vitro embryo development nor post-warming survival of the tagged embryos. All the embryos maintained barcodes attached until Day 8 of culture (3.63 ± 0.37 barcodes per embryo) and could be identified. In conclusion, identification of embryos by barcodes attached to the ZP is feasible and will allow the culture of embryos from different donors in the same drop.


  • Open Access

    Direct embryo tagging and identification system by attachment of biofunctionalized polysilicon barcodes to the zona pellucida of mouse embryos

    by Sergi Novo, Oriol Penon, Leonardo Barrios, Carme Nogués, Josep Santaló, Sara Durán, Rodrigo Gómez-Matínez, Josep Samitier, José Antonio Plaza, Luisa Pérez-García, et al.

    Is the attachment of biofunctionalized polysilicon barcodes to the outer surface of the zona pellucida an effective approach for the direct tagging and identification of cultured embryos? The results achieved provide a proof of concept for a direct embryo tagging system using biofunctionalized polysilicon barcodes, which could help to minimize the risk of mismatching errors (mix-ups) in human assisted reproduction technologies. Even though the occurrence of mix-ups is rare, several cases have been reported in fertility clinics around the world. Measures to prevent the risk of mix-ups in human assisted reproduction technologies are therefore required. Mouse embryos were tagged with 10 barcodes and the effectiveness of the tagging system was tested during fresh in vitro culture (n=140) and after embryo cryopreservation (n = 84). Finally, the full-term development of tagged embryos was evaluated (n =105). Mouse pronuclear embryos were individually rolled over wheat germ agglutinin-biofunctionalized polysilicon barcodes to distribute them uniformly around the ZONA PELLUCIDA surface. Embryo viability and retention of barcodes were determined during 96 h of culture. The identification of tagged embryos was performed every 24 h in an inverted microscope and without embryo manipulation to simulate an automatic reading procedure. Full-term development of the tagged embryos was assessed after their transfer to pseudo-pregnant females. To test the validity of the embryo tagging system after a cryopreservation process, tagged embryos were frozen at the 2-cell stage using a slow freezing protocol, and followed in culture for 72 h after thawing. Neither the in vitro or in vivo development of tagged embryos was adversely affected. The tagging system also proved effective during an embryo cryopreservation process. Global identification rates higher than 96 and 92% in fresh and frozen-thawed tagged embryos, respectively, were obtained when simulating an automatic barcode reading system, although these rates could be increased to 100% by simply rotating the embryos during the reading process. The direct embryo tagging developed here has exclusively been tested in mouse embryos. Its effectiveness in other species, such as the human, is currently being tested. The direct embryo tagging system developed here, once tested in human embryos, could provide fertility clinics with a novel tool to reduce the risk of mix-ups in human assisted reproduction technologies. This study was supported by Spanish Ministry of Education and Science (TEC2011-29140-C03) and by the Generalitat de Catalunya (2009SGR-00282). The authors do not have any competing interest.


  • Efficient Biofunctionalization of Polysilicon Barcodes for Adhesion to the Zona Pellucida of Mouse Embryos

    by Oriol Penon, Sergi Novo, Sara Durán, Elena Ibañez, Carme Nogués, Josep Samitier, Marta Duch, José Antonio Plaza, Lluïsa Pérez-García

    Cell tracking is an emergent area in nanobiotechnology, promising the study of individual cells or the identification of populations of cultured cells. In our approach, microtools designed for extracellular tagging are prepared, because using biofunctionalized polysilicon barcodes to tag cell membranes externally avoids the inconveniences of cell internalization. The crucial covalent biofunctionalization process determining the ultimate functionality was studied in order to find the optimum conditions to link a biomolecule to a polysilicon barcode surface using a self-assembled monolayer (SAM) as the connector. Specifically, a lectin (wheat germ agglutinin, WGA) was used because of its capacity to recognize some specific carbohydrates present on the surface of most mammalian cells. Self-assembled monolayers were prepared on polysilicon surfaces including aldehyde groups as terminal functions to study the suitability of their covalent chemical bonding to WGA. Some parameters, such as the polysilicon surface roughness or the concentration of WGA, proved to be crucial for successful biofunctionalization and bioactivity. The SAMs were characterized by contact angle measurements, time-of-flight secondary ion mass spectrometry (TOF-SIMS), laser desorption/ionization time-of-flight mass spectrometry (LDI-TOF MS), and atomic force microscopy (AFM). The biofunctionalization step was also characterized by fluorescence microscopy and, in the case of barcodes, by adhesion experiments to the zona pellucida of mouse embryos. These experiments showed high barcode retention rates after 96 h of culture as well as high embryo viability to the blastocyst stage, indicating the robustness of the biofunctionalization and, therefore, the potential of these new microtools to be used for cell tagging.