Federico Nicolas Guerrero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Federico Nicolas Guerrero has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Enrique Mario Spinelli
National University of La Plata
12 shared publications - Valentin A. Catacora
National University of La Plata
7 shared publications - Marcelo Alejandro Haberman
National University of La Plata
6 shared publications - Alfio Dario Grasso
University of Catania
3 shared publications - Gaetano Palumbo
Dipartimento di Ingegneria Elettrica, Elettronica e Informatica (DIEEI), Università degli Studi di Catania, 95123 Catania, Italy
3 shared publications - Pablo Andrés García
Instituto LEICI (UNLP-CONICET-CIC), Universidad Nacional de La Plata
2 shared publications
Latest Publications
- Open Access
- 14 August 2026
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 54 (10) , 5019-5029
A Current Conveyor Implementation of Double Differential Amplifier for Active Electrodes
This work presents two transistor‐level solutions to implement a double differential (DD) amplifier by using a current conveyor, which can be used as front‐ends in standalone active electrodes for superficial electromyography (sEMG) applications. Currently published DD amplifiers highlight the advantages of using second‐generation current conveyors to achieve simplified topologies, but they do not provide transistor level implementations. In this work, two solutions are presented and analyzed in detail.
- 14 August 2026
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 54 (10) , 5019-5029
Open AccessA Current Conveyor Implementation of Double Differential Amplifier for Active Electrodes
This work presents two transistor‐level solutions to implement a double differential (DD) amplifier by using a current conveyor, which can be used as front‐ends in standalone active electrodes for superficial electromyography (sEMG) applications. Currently published DD amplifiers highlight the advantages of using second‐generation current conveyors to achieve simplified topologies, but they do not provide transistor level implementations. In this work, two solutions are presented and analyzed in detail.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 2006408
An AC-Coupled Ultralow-Noise Fully Differential Amplifier
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 2006408
An AC-Coupled Ultralow-Noise Fully Differential Amplifier
- Open Access
Enhancing CMRR in Fully Differential Amplifiers via Power Supply Bootstrapping
Fully differential amplifier circuits are well suited for instrumentation front ends and signal-conditioning applications. They offer high common-mode rejection ratios (CMRRs) regardless of the passive component tolerances but remain sensitive to imbalances in active devices. By using power supply bootstrapping (PSB), the CMRRs of these circuits can be improved, where they become independent of mismatches in both passive and active components. This technique works by forcing the power supply nodes to follow the common-mode input voltage, which significantly enhances the CMRR. However, this approach introduces stability issues that must be addressed through dedicated compensation strategies without degrading the overall performance. In this work, the theoretical background, a design methodology, and experimental validation are presented. The proposed technique was applied to a fully differential amplifier built with general purpose operational amplifiers. Prior to the PSB, the amplifier exhibited a CMRR of 90 dB at 1 kHz. A straightforward application of PSB led to instability in the common-mode behavior; however, with the proposed compensation method, the amplifier achieved stable operation and an improved CMRR of 130 dB.
Open AccessEnhancing CMRR in Fully Differential Amplifiers via Power Supply Bootstrapping
Fully differential amplifier circuits are well suited for instrumentation front ends and signal-conditioning applications. They offer high common-mode rejection ratios (CMRRs) regardless of the passive component tolerances but remain sensitive to imbalances in active devices. By using power supply bootstrapping (PSB), the CMRRs of these circuits can be improved, where they become independent of mismatches in both passive and active components. This technique works by forcing the power supply nodes to follow the common-mode input voltage, which significantly enhances the CMRR. However, this approach introduces stability issues that must be addressed through dedicated compensation strategies without degrading the overall performance. In this work, the theoretical background, a design methodology, and experimental validation are presented. The proposed technique was applied to a fully differential amplifier built with general purpose operational amplifiers. Prior to the PSB, the amplifier exhibited a CMRR of 90 dB at 1 kHz. A straightforward application of PSB led to instability in the common-mode behavior; however, with the proposed compensation method, the amplifier achieved stable operation and an improved CMRR of 130 dB.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 655-662
Design of a Novel Very-Low Input Capacitance High-Bandwidth Buffer for a Biomass Sensor
In this work, a high-bandwidth very-low input capacitance original topology buffer was designed. The proposed buffer circuitry is conceived as part of a novel non-invasive non-immersed real-time dielectric spectroscopy biomass sensor. Both a circuital-based simulation model and an experimental PCB prototype were implemented and successfully tested. The buffer effective parasitic input capacitance was lowered to a 2% of its original value by means of power supply bootstrapping. This improvement will allow performing differential voltage measurements with the required accuracy and without compromising the necessary bandwidth.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 655-662
Design of a Novel Very-Low Input Capacitance High-Bandwidth Buffer for a Biomass Sensor
In this work, a high-bandwidth very-low input capacitance original topology buffer was designed. The proposed buffer circuitry is conceived as part of a novel non-invasive non-immersed real-time dielectric spectroscopy biomass sensor. Both a circuital-based simulation model and an experimental PCB prototype were implemented and successfully tested. The buffer effective parasitic input capacitance was lowered to a 2% of its original value by means of power supply bootstrapping. This improvement will allow performing differential voltage measurements with the required accuracy and without compromising the necessary bandwidth.
- 31 May 2024
- Published by Springer Nature
- p. 161-171
Real-Time SSVEP Measurements Through Lock-In Detection in FPGA-Based Platform
- 31 May 2024
- Published by Springer Nature
- p. 161-171
Real-Time SSVEP Measurements Through Lock-In Detection in FPGA-Based Platform
- 31 May 2024
- Published by Springer Nature
- p. 153-160
A Simplified Two-Wired Biopotential Active Electrode Topology
- 31 May 2024
- Published by Springer Nature
- p. 153-160
A Simplified Two-Wired Biopotential Active Electrode Topology
- Open Access
- 1 May 2024
- Published by MDPI AG in Electronics
- Vol. 13 (9) , 1735
Multi-Electrode EMG Spatial-Filter Implementation Based on Current Conveyors
In this work, a circuit topology for the implementation of a multi-electrode superficial electromyography (EMG) front-end is presented based on a type II current conveyor (CCII). The presented topology provides a feasible way to implement an amplifier capable of measuring several electrode locations and obtaining the signal of interest for posterior acquisition. In particular, a five-electrode normal double differential (NDD) EMG spatial filter is demonstrated. The signal modes necessary for the analysis of the circuit are derived, the respective rejection ratios are obtained, and the noise characteristic is calculated. A board-level electrode is implemented as a proof of concept, achieving a gain equal to 28 dB, a bandwidth of 17 Hz to 578 Hz, a noise voltage linked to the input of 3.7 and a common-mode rejection ratio higher than 95 dB at interference frequencies. The topology was validated after using it as an active electrode in experimental EMG measurements with an NDD dry-contact electrode in a flexible printed circuit board.- 1 May 2024
- Published by MDPI AG in Electronics
- Vol. 13 (9) , 1735
Open AccessMulti-Electrode EMG Spatial-Filter Implementation Based on Current Conveyors
In this work, a circuit topology for the implementation of a multi-electrode superficial electromyography (EMG) front-end is presented based on a type II current conveyor (CCII). The presented topology provides a feasible way to implement an amplifier capable of measuring several electrode locations and obtaining the signal of interest for posterior acquisition. In particular, a five-electrode normal double differential (NDD) EMG spatial filter is demonstrated. The signal modes necessary for the analysis of the circuit are derived, the respective rejection ratios are obtained, and the noise characteristic is calculated. A board-level electrode is implemented as a proof of concept, achieving a gain equal to 28 dB, a bandwidth of 17 Hz to 578 Hz, a noise voltage linked to the input of 3.7 and a common-mode rejection ratio higher than 95 dB at interference frequencies. The topology was validated after using it as an active electrode in experimental EMG measurements with an NDD dry-contact electrode in a flexible printed circuit board. - Open Access
- 25 October 2023
- Published by Universidad Nacional de La Plata in Journal of Computer Science and Technology
- Vol. 23 (2) , e11
A Dataset and Post-Processing Method for Pointing Device Human-Machine Interface Evaluation
The evaluation of human-machine interfaces (HMI) requires quantitative metrics to define the ability of a person to effectively achieve their goals using the HMI. In particular, for pointing-device type HMIs such as the computer mouse, an experiment quantifying movement by performing repetitive target selections allows defining a useful metric known as throughput (TP) using the Fitts’ Law test. In this work, a dataset obtained from an automated protocol application is presented, which is made publicly available through an on-line platform. A post-processing method to obtain performance parameters from the dataset is also presented, and its output is used to validate the data against similar experiments in the literature.
- 25 October 2023
- Published by Universidad Nacional de La Plata in Journal of Computer Science and Technology
- Vol. 23 (2) , e11
Open AccessA Dataset and Post-Processing Method for Pointing Device Human-Machine Interface Evaluation
The evaluation of human-machine interfaces (HMI) requires quantitative metrics to define the ability of a person to effectively achieve their goals using the HMI. In particular, for pointing-device type HMIs such as the computer mouse, an experiment quantifying movement by performing repetitive target selections allows defining a useful metric known as throughput (TP) using the Fitts’ Law test. In this work, a dataset obtained from an automated protocol application is presented, which is made publicly available through an on-line platform. A post-processing method to obtain performance parameters from the dataset is also presented, and its output is used to validate the data against similar experiments in the literature.
- Open Access
- 8 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
A hybrid amplifier topology for low-noise direct-coupled front ends
Hybrid amplifiers combine discrete transistors with operational amplifiers (OAs) achieving superior characteristics compared with commercially available OAs, while keeping simple structures and a reduced number of parts. A single-ended amplifier topology based on a junction field-effect transistor (JFET) is proposed as a means of achieving very low input noise levels, both in current and voltage. It is direct-coupled and allows to place a high-pass filter at its input to preserve input range, or at its output to optimize noise. The proposed topology results in a low input capacitance and low input-current noise, making it suitable for applications where multiple amplifiers are connected in parallel to achieve ultra-low noise levels. The amplifier’s gain is set by a resistor ratio, being suitable for instrumentation front ends. The circuit analysis and design equations are provided to adapt it for different applications and, as an example, an amplifier with a gain of 40 dB and a bandwidth from DC to 1 MHz was designed, built, and tested.
- 8 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessA hybrid amplifier topology for low-noise direct-coupled front ends
Hybrid amplifiers combine discrete transistors with operational amplifiers (OAs) achieving superior characteristics compared with commercially available OAs, while keeping simple structures and a reduced number of parts. A single-ended amplifier topology based on a junction field-effect transistor (JFET) is proposed as a means of achieving very low input noise levels, both in current and voltage. It is direct-coupled and allows to place a high-pass filter at its input to preserve input range, or at its output to optimize noise. The proposed topology results in a low input capacitance and low input-current noise, making it suitable for applications where multiple amplifiers are connected in parallel to achieve ultra-low noise levels. The amplifier’s gain is set by a resistor ratio, being suitable for instrumentation front ends. The circuit analysis and design equations are provided to adapt it for different applications and, as an example, an amplifier with a gain of 40 dB and a bandwidth from DC to 1 MHz was designed, built, and tested.
- 27 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Three-Electrode Double-Differential Biopotential Amplifier for Surface EMG Measurements
In this work, a novel double-differential (DD) amplifier for electromyogram (EMG) measurements is presented, which requires only three electrodes, a reduced number of components, and is focused on wearable devices of reduced size. The proposed topology is dual-mode, since it can also be used as a conventional single-differential (SD) EMG amplifier. The front-end sets the measurement center node at a reference potential, and uses single-ended amplifiers to form the DD signal at the common-mode output. To be able to measure with negligible electromagnetic interference, it is necessary to achieve a sufficiently large isolation impedance. A simple circuit with discrete components was implemented that allowed validating the operation of the proposed topology. Experimental measurements were made for its characterization, and the results are: 3 dB-bandwidth from 5 Hz to 460 Hz, DD gain of 34 dB in the passband, differential mode rejection ratio greater than 40 dB in the passband, and total noise referred to the input of 2.1 μV RMS . Also, the measurement of DD signals from the amplifier was verified by comparison with an additional acquisition device. Finally, the circuit was tested inside a small wearable device to measure surface EMG (sEMG). The results of this work validate that the proposed amplifier measures DD sEMG signals with only three electrodes, and is suitable for use in portable and wearable systems. This topology requires one less electrode than usual and has an extremely simple design with a reduced number of components.
- 27 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Three-Electrode Double-Differential Biopotential Amplifier for Surface EMG Measurements
In this work, a novel double-differential (DD) amplifier for electromyogram (EMG) measurements is presented, which requires only three electrodes, a reduced number of components, and is focused on wearable devices of reduced size. The proposed topology is dual-mode, since it can also be used as a conventional single-differential (SD) EMG amplifier. The front-end sets the measurement center node at a reference potential, and uses single-ended amplifiers to form the DD signal at the common-mode output. To be able to measure with negligible electromagnetic interference, it is necessary to achieve a sufficiently large isolation impedance. A simple circuit with discrete components was implemented that allowed validating the operation of the proposed topology. Experimental measurements were made for its characterization, and the results are: 3 dB-bandwidth from 5 Hz to 460 Hz, DD gain of 34 dB in the passband, differential mode rejection ratio greater than 40 dB in the passband, and total noise referred to the input of 2.1 μV RMS . Also, the measurement of DD signals from the amplifier was verified by comparison with an additional acquisition device. Finally, the circuit was tested inside a small wearable device to measure surface EMG (sEMG). The results of this work validate that the proposed amplifier measures DD sEMG signals with only three electrodes, and is suitable for use in portable and wearable systems. This topology requires one less electrode than usual and has an extremely simple design with a reduced number of components.