Timur Jan-Peter Özelsel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Timur Jan-Peter Özelsel has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Rakesh Vijayashankar Sondekoppam
Department of Anesthesia, Perioperative and Pain Medicine, Stanford University, Palo Alto, California, USA
9 shared publications Ban C. H. Tsui
Department of Anesthesiology, Perioperative, and Pain Medicine, Stanford University School of Medicine, Palo Alto, CA, USA
3 shared publications- Ban C. H. Tsui
The Chinese University of Hong Kong Shenzhen China
3 shared publications Karen Buro
Department of Mathematics and Statistics, MacEwan University, Edmonton, Canada
3 shared publicationsRakesh V. Sondekoppam
Department of Anesthesia, University of Iowa Hospitals and Clinics, Iowa City, USA
2 shared publicationsSaifee Rashiq
Department of Anesthesiology & Pain Medicine, University of Alberta, 2-150 Clinical Sciences Building, Edmonton, AB, T6G 2G3, Canada
2 shared publications
Latest Publications
- Open Access
- 18 January 2025
- Published by Wolters Kluwer Health in Medical Gas Research
- Vol. 15 (2) , 254-265
Sevoflurane and its metabolic byproduct compound A induce nephrotoxicity: a systematic review and meta-analysis of animal studies
Animal models investigating sevoflurane or compound A and renal function serve as the initial basis for concerns regarding renal injury following sevoflurane anesthesia and subsequent recommendations of minimum fresh gas flow, but this evidence basis has not been critically appraised. Primary literature searches were performed in MEDLINE OVID, PubMed, EMBASE, the Cochrane Library), the Cochrane Central Register of Controlled Trials, the International HTA Database, CINAHL, and Web of Science to identify randomized controlled trials and quasi-experimental studies in animals utilizing sevoflurane or compound A. The primary outcomes included renal function as determined by blood urea nitrogen, serum creatinine, creatinine clearance, and urine volume. The secondary outcomes included the serum fluoride concentration and histopathological findings. A total of 2537 records were screened, and 21 randomized controlled trials and 9 quasi-experimental animal studies were identified. No associations between sevoflurane exposure and subsequent changes in renal function (blood urea nitrogen, serum creatinine or changes in urine volume) were noted. A similar effect on renal function was observed following compound A exposure, but urine volume was elevated following compound A exposure. In addition, the histopathological damage following compound A exposure was observed only at concentrations that are unachievable in clinical practice. Our review of evidence from animal models revealed that sevoflurane usage was not associated with changes in renal function tests or urine volume. Histopathologic changes after sevoflurane exposure were either nonexistent or minor. Studies on compound A did not reveal an alteration in renal function, although histopathological evidence of injury was present when compound A was administered at very high, unphysiologic concentrations. In light of the existing evidence, the initial concerns of sevoflurane-related nephrotoxicity based on animal studies that leads to minimum fresh gas flow recommendations are called into question.
- 18 January 2025
- Published by Wolters Kluwer Health in Medical Gas Research
- Vol. 15 (2) , 254-265
Open AccessSevoflurane and its metabolic byproduct compound A induce nephrotoxicity: a systematic review and meta-analysis of animal studies
Animal models investigating sevoflurane or compound A and renal function serve as the initial basis for concerns regarding renal injury following sevoflurane anesthesia and subsequent recommendations of minimum fresh gas flow, but this evidence basis has not been critically appraised. Primary literature searches were performed in MEDLINE OVID, PubMed, EMBASE, the Cochrane Library), the Cochrane Central Register of Controlled Trials, the International HTA Database, CINAHL, and Web of Science to identify randomized controlled trials and quasi-experimental studies in animals utilizing sevoflurane or compound A. The primary outcomes included renal function as determined by blood urea nitrogen, serum creatinine, creatinine clearance, and urine volume. The secondary outcomes included the serum fluoride concentration and histopathological findings. A total of 2537 records were screened, and 21 randomized controlled trials and 9 quasi-experimental animal studies were identified. No associations between sevoflurane exposure and subsequent changes in renal function (blood urea nitrogen, serum creatinine or changes in urine volume) were noted. A similar effect on renal function was observed following compound A exposure, but urine volume was elevated following compound A exposure. In addition, the histopathological damage following compound A exposure was observed only at concentrations that are unachievable in clinical practice. Our review of evidence from animal models revealed that sevoflurane usage was not associated with changes in renal function tests or urine volume. Histopathologic changes after sevoflurane exposure were either nonexistent or minor. Studies on compound A did not reveal an alteration in renal function, although histopathological evidence of injury was present when compound A was administered at very high, unphysiologic concentrations. In light of the existing evidence, the initial concerns of sevoflurane-related nephrotoxicity based on animal studies that leads to minimum fresh gas flow recommendations are called into question.
- 25 September 2023
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 70 (12) , 1928-1938
Comparison of the Quality of Recovery-15 score in patients undergoing oncoplastic breast-conserving surgery under monitored anesthesia care versus general anesthesia: a prospective quality improvement study
Purpose Whether changing the institutional practice from general anesthesia (GA) to monitored anesthesia care (MAC) affects postoperative quality of recovery for oncoplastic breast-conserving surgery (BCS) is currently unknown. We designed this quasi-experimental study to evaluate a quality improvement (QI) initiative instituted in Edmonton, AB, Canada. Methods We chose a prospective controlled cohort study design for this QI study, where patients underwent oncoplastic BCS under MAC in one hospital and BCS under GA at another hospital (control). A total of 125 patients undergoing surgery between May 2021 and February 2022 were enrolled. Exclusion criteria were male sex, total mastectomy, or age under 18. All other patients were included. The primary outcome was the change in Quality of Recovery-15 score at 24 hr compared with a preoperative baseline. Secondary outcomes included intra- and postoperative time profiles, perioperative analgesic and antiemetic use and length of hospital stay. Statistical analysis included a propensity score analysis to account for confounding variables. Results Sixty-four patients received GA and 61 MAC. No enrolled patients were lost to follow up but two were excluded secondarily. No patients receiving MAC needed conversion to GA or unplanned airway management. Monitored anesthesia care was associated with superior outcomes for the primary outcome (β/SE[β], 3.31; 99.5% confidence interval, 0.45 to 6.17; P = 0.001) and most secondary outcomes, when accounting for confounding factors. Conclusions A care transformation initiative for patients undergoing oncoplastic BCS under MAC was associated with a higher quality recovery profile and shorter length of stay without any increase in perioperative or postoperative adverse events.
- 25 September 2023
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 70 (12) , 1928-1938
Comparison of the Quality of Recovery-15 score in patients undergoing oncoplastic breast-conserving surgery under monitored anesthesia care versus general anesthesia: a prospective quality improvement study
Purpose Whether changing the institutional practice from general anesthesia (GA) to monitored anesthesia care (MAC) affects postoperative quality of recovery for oncoplastic breast-conserving surgery (BCS) is currently unknown. We designed this quasi-experimental study to evaluate a quality improvement (QI) initiative instituted in Edmonton, AB, Canada. Methods We chose a prospective controlled cohort study design for this QI study, where patients underwent oncoplastic BCS under MAC in one hospital and BCS under GA at another hospital (control). A total of 125 patients undergoing surgery between May 2021 and February 2022 were enrolled. Exclusion criteria were male sex, total mastectomy, or age under 18. All other patients were included. The primary outcome was the change in Quality of Recovery-15 score at 24 hr compared with a preoperative baseline. Secondary outcomes included intra- and postoperative time profiles, perioperative analgesic and antiemetic use and length of hospital stay. Statistical analysis included a propensity score analysis to account for confounding variables. Results Sixty-four patients received GA and 61 MAC. No enrolled patients were lost to follow up but two were excluded secondarily. No patients receiving MAC needed conversion to GA or unplanned airway management. Monitored anesthesia care was associated with superior outcomes for the primary outcome (β/SE[β], 3.31; 99.5% confidence interval, 0.45 to 6.17; P = 0.001) and most secondary outcomes, when accounting for confounding factors. Conclusions A care transformation initiative for patients undergoing oncoplastic BCS under MAC was associated with a higher quality recovery profile and shorter length of stay without any increase in perioperative or postoperative adverse events.
- Open Access
- 22 September 2021
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 69 (1) , 182-183
Code Red will become Code Blue for humanity: an urgent call for action in the anesthesia community
- 22 September 2021
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 69 (1) , 182-183
Open AccessCode Red will become Code Blue for humanity: an urgent call for action in the anesthesia community
- Open Access
- 26 May 2021
- Published by Elsevier in Resources, Conservation & Recycling Advances
- Vol. 12, 200053
In response: The carbon footprint of general anaesthetics: A case study in the UK
- 26 May 2021
- Published by Elsevier in Resources, Conservation & Recycling Advances
- Vol. 12, 200053
Open AccessIn response: The carbon footprint of general anaesthetics: A case study in the UK
- 3 September 2020
- Published by BMJ in Regional Anesthesia & Pain Medicine
- Vol. 46 (6) , 553-554
“Green-gional” anesthesia: a lot greener than you think
- 3 September 2020
- Published by BMJ in Regional Anesthesia & Pain Medicine
- Vol. 46 (6) , 553-554
“Green-gional” anesthesia: a lot greener than you think
- 18 August 2020
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 67 (11) , 1595-1623
The impact of sevoflurane anesthesia on postoperative renal function: a systematic review and meta-analysis of randomized-controlled trials
Purpose Renal damage secondary to fluoride ions and compound A (CpdA) after sevoflurane anesthesia remains unclear. For safety reasons, some countries still recommend minimum fresh-gas flows (FGFs) with sevoflurane. We review the evidence regarding the intraoperative use of sevoflurane for anesthesia maintenance and postoperative renal function compared with other anesthetic agents used for anesthetic maintenance. Secondarily, we examine the effects of peak plasma fluoride and CpdA levels and the effect of FGF and duration of anesthesia on these parameters. Source The databases of MEDLINE (OVID and Pubmed), EMBASE, the Cochrane Library, Health Technology Assessment Database, CINAHL, and Web of Science were searched from inception until 23 April 2020 to identify randomized-controlled trials (RCTs) in humans utilizing sevoflurane or an alternative anesthetic for anesthesia maintenance with subsequent measurements of renal function. Two different paired reviewers independently selected the studies and extracted data. The quality of the evidence was appraised using GRADE recommendations. Principal findings Of 3,766 publications screened, 41 RCTs in human patients were identified. There was no difference between creatinine at 24 hr (21 studies; n = 1,529), or creatinine clearance (CCR) at 24 hr (12 studies; n = 728) in the sevoflurane vs alternative anesthetic groups. Peak fluoride and fluoride measured at 24 hr were higher with sevoflurane compared with other inhaled anesthetics. Subgroup analyses for sevoflurane usage in various contexts showed no significant difference between sevoflurane and alternative anesthetics for creatinine or CCR at 24 hr at varying FGF, duration of exposure, baseline renal function, or absorbent use. Conclusions We did not find any association between the use of sevoflurane and postoperative renal impairment compared with other agents used for anesthesia maintenance. The scientific basis for recommending higher FGF with the use of sevoflurane needs to be revisited.
- 18 August 2020
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 67 (11) , 1595-1623
The impact of sevoflurane anesthesia on postoperative renal function: a systematic review and meta-analysis of randomized-controlled trials
Purpose Renal damage secondary to fluoride ions and compound A (CpdA) after sevoflurane anesthesia remains unclear. For safety reasons, some countries still recommend minimum fresh-gas flows (FGFs) with sevoflurane. We review the evidence regarding the intraoperative use of sevoflurane for anesthesia maintenance and postoperative renal function compared with other anesthetic agents used for anesthetic maintenance. Secondarily, we examine the effects of peak plasma fluoride and CpdA levels and the effect of FGF and duration of anesthesia on these parameters. Source The databases of MEDLINE (OVID and Pubmed), EMBASE, the Cochrane Library, Health Technology Assessment Database, CINAHL, and Web of Science were searched from inception until 23 April 2020 to identify randomized-controlled trials (RCTs) in humans utilizing sevoflurane or an alternative anesthetic for anesthesia maintenance with subsequent measurements of renal function. Two different paired reviewers independently selected the studies and extracted data. The quality of the evidence was appraised using GRADE recommendations. Principal findings Of 3,766 publications screened, 41 RCTs in human patients were identified. There was no difference between creatinine at 24 hr (21 studies; n = 1,529), or creatinine clearance (CCR) at 24 hr (12 studies; n = 728) in the sevoflurane vs alternative anesthetic groups. Peak fluoride and fluoride measured at 24 hr were higher with sevoflurane compared with other inhaled anesthetics. Subgroup analyses for sevoflurane usage in various contexts showed no significant difference between sevoflurane and alternative anesthetics for creatinine or CCR at 24 hr at varying FGF, duration of exposure, baseline renal function, or absorbent use. Conclusions We did not find any association between the use of sevoflurane and postoperative renal impairment compared with other agents used for anesthesia maintenance. The scientific basis for recommending higher FGF with the use of sevoflurane needs to be revisited.
- 8 May 2019
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 66 (11) , 1291-1295
The future is now—it’s time to rethink the application of the Global Warming Potential to anesthesia
- 8 May 2019
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 66 (11) , 1291-1295
The future is now—it’s time to rethink the application of the Global Warming Potential to anesthesia
- 2 March 2019
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 57, 5-6
Evaluating the success of Erector Spinae Plane block: Believing is seeing?
- 2 March 2019
- Published by Elsevier in Journal of Clinical Anesthesia
- Vol. 57, 5-6
Evaluating the success of Erector Spinae Plane block: Believing is seeing?
- 3 January 2019
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 66 (4) , 474-475
“If I had a million dollars…”: The curious incident of a city, a forest, and sustainable anesthesia
- 3 January 2019
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 66 (4) , 474-475
“If I had a million dollars…”: The curious incident of a city, a forest, and sustainable anesthesia
- Open Access
- 17 December 2018
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 66 (3) , 249-254
Re-defining the 3R’s (reduce, refine, and replace) of sustainability to minimize the environmental impact of inhalational anesthetic agents
- 17 December 2018
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 66 (3) , 249-254
Open AccessRe-defining the 3R’s (reduce, refine, and replace) of sustainability to minimize the environmental impact of inhalational anesthetic agents