SGShai N. Gozani

Shai N. Gozani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shai N. Gozani has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of Wearable Transcutaneous Electrical Nerve Stimulation on Fibromyalgia: A Randomized Controlled Trial

    by Robert N Jamison, Robert R Edwards, Samantha Curran, Limeng Wan, Edgar L Ross, Christopher J Gilligan, Shai N Gozani

    Purpose: Fibromyalgia is a chronic condition characterized by widespread pain and interference with daily activities. The aim of this study is to assess the benefit of transcutaneous electrical nerve stimulation (TENS) for persons diagnosed with fibromyalgia. Patients and Methods: Adults meeting diagnostic criteria for fibromyalgia were randomized in a double-blind trial to receive either an active (n=62) or sham (n=57) wearable TENS device for 3-months. Subjects were classified as having lower or higher pain sensitivity by Quantitative Sensory Testing (QST). Patient Global Impression of Change (PGIC, primary outcome) and secondary efficacy measures including Fibromyalgia Impact Questionnaire (FIQR), Brief Pain Inventory (BPI) and painDETECT questionnaire (PDQ) were assessed at baseline, 6-weeks and 3-months. Treatment effects were determined by a mixed model for repeated measures (MMRM) analysis of the intention-to-treat (ITT) population (N=119). A pre-specified subgroup analysis of pain sensitivity was conducted using an interaction term in the model. Results: No differences were found between active and sham treatment on PGIC scores at 3-months (0.34, 95% CI [− 0.37, 1.04], p=0.351) in the ITT population. However, in subjects with higher pain sensitivity (n=60), PGIC was significantly greater for active treatment compared to sham (1.19, 95% CI [0.24, 2.13], p=0.014). FIQR total score (− 7.47, 95% CI [− 12.46, − 2.48], p=0.003), FIQR pain item (− 0.62, 95% CI [− 1.17, − 0.06], p=0.029), BPI Interference (− 0.70, 95% CI [− 1.30, − 0.11], p=0.021) and PDQ (− 1.69, 95% CI [− 3.20, − 0.18], p=0.028) exhibited significant improvements for active treatment compared to sham in the ITT population. Analgesics use was stable and comparable in both groups. Conclusion: This study demonstrated modest treatment effects of reduced disease impact, pain and functional impairment from wearable TENS in individuals with fibromyalgia. Subjects with higher pain sensitivity exhibited larger treatment effects than those with lower pain sensitivity. Wearable TENS may be a safe treatment option for people with fibromyalgia. Clinicaltrials.gov Registration: NCT03714425.


  • Open Access

    Remote Analgesic Effects Of Conventional Transcutaneous Electrical Nerve Stimulation: A Scientific And Clinical Review With A Focus On Chronic Pain

    by Shai N Gozani

    Background: Transcutaneous electrical nerve stimulation (TENS) is a safe, noninvasive treatment for chronic pain that can be self-administered. Conventional TENS involves stimulation of peripheral sensory nerves at a strong, non-painful level. Following the original gate-control theory of pain, stimulation is typically near the target pain. As another option, remote stimulation may also be effective and offers potential advantages. Objective: This narrative review examines mechanisms underlying the remote analgesic effects of conventional TENS and appraises the clinical evidence. Methods: A literature search for English-language articles was performed on PubMed. Keywords included terms related to the location of TENS . Citations from primary references and textbooks were examined for additional articles. Results: Over 30 studies reported remote analgesic effects of conventional TENS. The evidence included studies using animal models of pain, experimental pain in humans, and clinical studies in subjects with chronic pain. Three types of remote analgesia were identified: at the contralateral homologous site, at sites distant from stimulation but innervated by overlapping spinal segments, and at unrelated extrasegmental sites. Conclusion: There is scientific and clinical evidence that conventional TENS has remote analgesic effects. This may occur through modulation of pain processing at the level of the dorsal horn, in brainstem centers mediating descending inhibition, and within the pain matrix. A broadening of perspectives on how conventional TENS produces analgesia may encourage researchers, clinicians, and medical-device manufacturers to develop novel ways of using this safe, cost-effective neuromodulation technique for chronic pain.


  • Open Access

    Impact of transcutaneous electrical nerve stimulation on sleep in chronic low back pain: a real-world retrospective cohort study

    by Shai N Gozani, Thomas C Ferree, Martin Moynihan, Xuan Kong

    Objective: The purpose of this study was to determine if transcutaneous electrical nerve stimulation (TENS) improves sleep in chronic low back pain (CLBP). Background: There is uncertainty over the effectiveness of TENS in CLBP. In most studies, pain intensity has been the primary outcome measure. Although sleep abnormalities are common in CLBP, sleep outcomes have not been evaluated in most studies of TENS effectiveness. Subjective and objective sleep measures are often inconsistent in CLBP, suggesting that perception of sleep and actual sleep may differ. Methods: This retrospective cohort study evaluated TENS for CLBP over 10 weeks. The source database included demographics, pain characteristics, pain intensity and interference on an 11-point numerical rating scale, adherence and actigraphic sleep data from real-world TENS users. Key inclusion criteria were CLBP with self-reported history of back injury and baseline pain interference with sleep ≥4. Study participants were stratified into improved and unimproved groups based on changes in pain interference with sleep (improved ≥1-point decrease). Actigraphic sleep metrics were compared between the two groups for weeks 1–2 and weeks 9–10. Results: The inclusion criteria were met by 554 TENS users. There were 282 (50.9%) participants in the improved group and 272 (49.1%) in the unimproved group. The two groups had similar baseline characteristics and high TENS adherence. At the weeks 1–2 assessment, there were no differences among actigraphic sleep. At the weeks 9–10 assessment, there was a difference in total sleep time, with the improved group sleeping 29 minutes longer. In addition, the periodic leg movement (PLM) index was lower in the improved group. Conclusion: Regular TENS improved self-reported and objective sleep measures in individuals with CLBP. When compared to the unimproved group, the improved group had longer total sleep time and fewer PLMs. Sleep may be an important outcome for TENS effectiveness in CLBP.


  • Open Access

    Effectiveness of fixed-site high-frequency transcutaneous electrical nerve stimulation in chronic pain: a large-scale, observational study

    by Xuan Kong, Shai N Gozani

    Objective: The objective of this study was to assess the effectiveness of fixed-site high-frequency transcutaneous electrical nerve stimulation (FS-TENS) in a real-world chronic pain sample. Background: There is a need for nonpharmacological treatment options for chronic pain. FS-TENS improved multisite chronic pain in a previous interventional study. Large observational studies are needed to further characterize its effectiveness. Methods: This retrospective observational cohort study examined changes in chronic pain measures following 60 days of FS-TENS use. The study data were obtained from FS-TENS users who uploaded their device utilization and clinical data to an online database. The primary outcome measures were changes in pain intensity and pain interference with sleep, activity, and mood on an 11-point numerical rating scale. Dose–response associations were evaluated by stratifying subjects into low (≤30 days), intermediate (31–56 days), and high (≥57 days) utilization subgroups. FS-TENS effectiveness was quantified by baseline to follow-up group differences and a responder analysis (≥30% improvement in pain intensity or ≥2-point improvement in pain interference domains). Results: Utilization and clinical data were collected from 11,900 people using FS-TENS for chronic pain, with 713 device users meeting the inclusion and exclusion criteria. Study subjects were generally older, overweight adults. Subjects reported multisite pain with a mean of 4.8 (standard deviation [SD] 2.5) pain sites. A total of 97.2% of subjects identified low back and/or lower extremity pain, and 72.9% of subjects reported upper body pain. All pain measures exhibited statistically significant group differences from baseline to 60-day follow-up. The largest changes were pain interference with activity (−0.99±2.69 points) and mood (−1.02±2.78 points). A total of 48.7% of subjects exhibited a clinically meaningful reduction in pain interference with activity or mood. This proportion increased to 57.1% for the high utilization subgroup. Conclusion: FS-TENS is a practical option for treating multisite chronic pain. The greatest impact is on pain interference with activity and mood. FS-TENS utilization and effectiveness exhibit a dose–response association, suggesting that daily use maximizes pain relief.


  • Open Access

    Fixed-site high-frequency transcutaneous electrical nerve stimulation for treatment of chronic low back and lower extremity pain

    by Shai N Gozani

    Objective: The objective of this study was to determine if fixed-site high-frequency transcutaneous electrical nerve stimulation (FS-TENS) is effective in treating chronic low back and lower extremity pain. Background: Transcutaneous electrical nerve stimulation is widely used for treatment of chronic pain. General-purpose transcutaneous electrical nerve stimulation devices are designed for stimulation anywhere on the body and often cannot be used while the user is active or sleeping. FS-TENS devices are designed for placement at a pre-determined location, which enables development of a wearable device for use over extended time periods. Methods: Study participants with chronic low back and/or lower extremity pain self-administered an FS-TENS device for 60 days. Baseline, 30-, and 60-day follow-up data were obtained through an online questionnaire. The primary outcome measure was the patient global impression of change. Pain intensity and interference were assessed using the Brief Pain Inventory. Changes in use of concomitant pain medications were evaluated with a single-item global self-rating. Results: One hundred and thirty participants were enrolled, with 88 completing the 60-day follow-up questionnaire. Most participants (73.9%) were 50 years of age or older. At baseline, low back pain was identified by 85.3%, lower extremity pain by 71.6%, and upper extremity pain by 62.5%. Participants reported widespread pain, at baseline, with a mean of 3.4 (standard deviation 1.1) pain sites. At the 60-day follow-up, 80.7% of participants reported that their chronic pain had improved and they were classified as responders. Baseline characteristics did not differentiate non-responders from responders. There were numerical trends toward reduced pain interference with walking ability and sleep, and greater pain relief in responders. There was a large difference in use of concomitant pain medications, with 80.3% of responders reporting a reduction compared to 11.8% of non-responders. Conclusion: FS-TENS is a safe and effective option for treating chronic low back and lower extremity pain. These results motivate the use of FS-TENS in development of wearable analgesic devices.


  • Open Access

    Utility of Nerve Conduction Studies for Carpal Tunnel Syndrome by Family Medicine, Primary Care, and Internal Medicine Physicians

    by J. Thomas Megerian, Xuan Kong, Shai N. Gozani

    Introduction: Nerve conduction studies (NCS) are increasingly being performed at the point-of-service by family medicine, primary care, and internal medicine (FM/PCP/IM) physicians. Carpal tunnel syndrome (CTS) is a common neuropathy often diagnosed with the aid of NCS.


    • 1 November 2006
      • Vol. 35  (11) , 515-9

    Time-dependent changes in median nerve sensory amplitude after local anesthetic administration and tourniquet application.

    by Wendy L Timpson, Xuan Kong, Ward P Hamlet, Patrick Gross, Shai N Gozani

    Indirect visualization, as used in several newer mini-open and endoscopic carpal tunnel release (CTR) procedures, may increase the possibility of nerve injury in some cases. Intraoperative neural monitoring may be used to evaluate nerve location and integrity. In the study reported here, we assessed the feasibility of intraoperative neural monitoring by systematically exploring the effect of local anesthetic and tourniquet on median sensory amplitude. Results for 30 median nerves (7 symptomatic) showed that sensory amplitude decreased, on average, 54% with lidocaine injection, 15% with tourniquet application, and 47% with the combination. Sensory amplitudes of 9 of 10 nerves were still above 1.0 microV 15 minutes after anesthetic administration and tourniquet application. Study results demonstrate that intraoperative monitoring, using the amplitude of the median sensory nerve response, is viable under CTR conditions.

  • Electrodiagnostic Automation: Principles and Practice

    by Shai N. Gozani, Morris A. Fisher, Xuan Kong, J. Thomas Megerian, Seward B. Rutkove