FZFrancesco Zambianchi

Francesco Zambianchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Francesco Zambianchi has a total of 100 co-authors. Here are the top co-authors by number of shared publications:

  • Fabio Catani

    Department of Orthopaedic Surgery, Azienda Ospedaliero-Universitaria Policlinico di Modena, University of Modena and Reggio-Emilia, Modena, Italy

    26 shared publications
  • Fabio Catani

    Department of Orthopaedics and Traumatology, Azienda Ospedaliero-Universitaria di Modena, Università Degli Studi di Modena e Reggio-Emilia, Modena, Italy; Department of Orthopaedic Surgery, School of Medicine, University of Pittsburgh, Pittsburgh, Pennsylvania

    14 shared publications
  • Andrea Marcovigi

    Department of Orthopaedic Surgery, Azienda Ospedaliero-Universitaria Policlinico Di Modena, Modena, Italy

    8 shared publications
  • Luigi Tarallo

    Department of Orthopaedics and Traumatology, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy

    8 shared publications
  • Riccardo Cuoghi Costantini

    Department of Diagnostic and Clinical Medicine and Public Health, Statistics Unit, Università degli Studi di Modena e Reggio-Emilia, Modena, Italy

    7 shared publications
  • Raffaele Mugnai

    Department of Orthopaedic Surgery, University of Modena and Reggio Emilia, Modena, Italy

    6 shared publications

Latest Publications

  • Open Access

    Reduced workload demand with handheld robotic‐assisted revision knee arthroplasty: A multi‐centre NASA Task Load Index analysis

    by Andrew Porteous, James Murray, Max Ettinger, Peter Savov, Matteo Innocenti, Gijs van Hellemondt, Koen DeFoort, Juan Carlos Martinez‐Pastor, Peter Bollars, Francesco Zambianchi, et al.

    Purpose: Revision total knee arthroplasty is a complex and technically demanding procedure, with an increasing global incidence. This complexity heightens the cognitive and physical demands of surgical teams, contributing to elevated burnout, musculoskeletal injuries and psychological stress. This European wide multi‐centre observational evaluation assessed the impact of a handheld robotic‐assisted surgical system on intra‐operative workload using the NASA Task Load Index instrument to compare robotic‐assisted and manual instrumentation approaches during revision knee arthroplasty. Methods: Data were collected from 212 surveys following 100 revision knee arthroplasty procedures, capturing subjective workload measures across six NASA Task Load Index domains from surgeons and peri‐operative theatre staff. Results: The results demonstrated a significant reduction in the overall workload with robotic‐assistance compared with manual instrumentation (median overall workload score 0.0 vs. 8.5 respectively, p = 0.0003). Domain‐specific analyses revealed significantly lower mental demand, physical demand and effort in the robotic‐assisted group without compromising perceived surgical performance, temporal demand, or frustration. A subgroup analysis of the lead surgeons showed consistent perceived workload reductions consistent with the overall findings. These results suggest that the handheld robotic‐assisted surgical system may mitigate cognitive and physical strain during complex revision knee arthroplasty procedures. Conclusions: This evaluation underscores the potential of robotic‐assisted technology to enhance surgical ergonomics, reduce surgeon fatigue and improve well‐being, which may translate into sustained surgical performance. Future work should incorporate objective ergonomic measures, expand participant roles and explore long‐term impacts on clinical outcomes and staff welfare. Level of Evidence: Level II.


  • Open Access

    Tibial Component Varus Alignment Does Not Affect Survivorship of Cementless Robotic-Assisted Total Knee Arthroplasty With Functional Knee Positioning

    by Francesco Zambianchi, Mattia Clò, Sebastiano Clemenza, Riccardo Cuoghi Costantini, Vincenzo Iorio, Fabio Catani

  • Open Access

    An Asymmetric Medio-Lateral Flexion Laxity Target Yields Excellent Results in Robotic-Assisted Total Knee Arthroplasty With Functional Knee Positioning

    by Hannes Vermue, Francesco Zambianchi, Sebastiano Clemenza, Mattia Clò, Jan Victor, Fabio Catani


  • Open Access

    Impact of functional evaluation 3D software on impingement and clinical outcomes in robotic-arm assisted total hip arthroplasty

    by Enrico Bertugli, Andrea Marcovigi, Filippo Selleri, Gianluca Grandi, Francesco Zambianchi, Fabio Catani

    Background: This study aims to investigate whether individualized component positioning in robotic-assisted total hip arthroplasty (RTHA) using three-dimensional (3D) Functional Component Positioning Assessment (FCPA) reduces prosthetic and bone impingement and improves Patient-Reported Outcome Measures (PROMs). Methods: This retrospective study includes 100 consecutive patients who underwent RTHA at a single center between May 2021 and March 2022 using the Mako THA system. Preoperative imaging and planning incorporated sacral slope (SS) measurements. SS values in standing and sitting positions were uploaded into the robotic software to simulate prosthetic hip motion during FCPA and guide component orientation. The primary outcome measures included intraoperative impingement analyses using FCPA and postoperative PROMs, including the Oxford Hip Score (OHS), Forgotten Joint Score (FJS-12), and Hip Disability and Osteoarthritis Outcome Score (HOOS). Results: Impingement was detected in 46% of patients during daily living activities, with prosthesis-on-prosthesis being the most frequent impingement type. No statistically significant differences in PROMs were observed between patients with and without impingement. Nonetheless, overall PROMs were excellent, with a mean HOOS of 94.2 ± 8.3, mean FJS-12 of 87.8 ± 17.2, and mean OHS of 92.3 ± 10. Multivariate analysis revealed that higher BMI negatively impacted PROMs, and the SS difference correlated significantly with OHS and FJS-12 scores (P < 0.0001). Conclusions: Individualized component positioning, even when aided by 3D FCPA, does not eliminate the risk of impingement. The concept of a universal “safe zone” may be inadequate to prevent impingement, emphasizing the need for patient-specific implant positioning strategies based on spinopelvic mobility. While impingement did not significantly impact PROMs, optimizing implant positioning through robotic-assisted techniques may contribute to improved long-term outcomes and reduced dislocation risk.


  • Open Access

    Comparable clinical outcomes in functionally aligned computer‐assisted and image‐based robotic assisted total knee arthroplasty

    by Stefano Seracchioli, Francesco Zambianchi, Sebastiano Clemenza, Mattia Clò, Riccardo Cuoghi Costantini, Fabio Catani

    Purpose: To determine the clinical outcomes differences and complications in two comparable groups of patients undergoing computer aided surgery (CAS) and robotic‐assisted (RA) posterior stabilised (PS) total knee arthroplasty (TKA) following functional alignment (FA) principles with tibial pre‐cut at a minimum of 4‐year follow‐up. Methods: This retrospective, monocentric and observational study included 94 consecutive patients undergoing PS TKA performed with CAS and RA‐TKA following FA principles, between January 2017 and January 2020. Patients were followed with radiological and clinical assessment and evaluated with the Forgotten Joint Score‐12 (FJS‐12), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS‐JR) and the 5‐Level Likert Scale (5‐LLS). Results: Out of 94 patients two were lost to follow‐up and one deceased in the robotic branch, eight patients were lost to follow‐up and two were deceased in the navigated branch. Hereby, a total of 84 patients (87 knees) with a mean age of 69.2 ± 8.4 years were considered. A total of 40 cases were included in the CAS group; 44 cases were included in the RA‐TKA group. No revisions were performed in any of the two groups, resulting in an overall Kaplan‐Meyer survivorship rate of 100% for both cohorts. At last follow‐up, no statistically significant differences were recorded between CAS and RA‐TKA relative to FJS‐12, KOOS‐JR and 5‐LLS (FJS‐12: 89.4 ± 9.5 vs. 88.3 ± 13.4; KOOS‐JR: 88.0 ± 10.2 vs 86.2 ± 11.5; 5‐LLS 4.4 ± 1.7 vs 4.6 ± 2.1) respectively. Conclusions: No significant outcomes differences and complications were detected between patients undergoing PS‐TKA performed with either CAS and RA at a minimum 4‐year follow‐up. TKA performed with a patient‐specific FA technique and with a soft tissue‐preserving approach, showed excellent results with both CAS and RA‐TKA. Level of Evidence: Level III.


  • Open Access

    Femoral component rotational alignment in robotic‐assisted total knee arthroplasty with functional knee positioning varies across knee phenotypes without affecting clinical outcomes

    by Francesco Zambianchi, Gabriele Bazzan, Vincenzo Iorio, Riccardo Cuoghi Costantini, Stefano Seracchioli, Fabio Catani

    Purpose: This retrospective, observational study aimed to investigate the distribution of femoral component rotational alignment among different knee phenotypes and assess the clinical relevance of femoral component rotation variability in patients undergoing image‐based robotic‐assisted total knee arthroplasty (RA‐TKA) performed with functional knee positioning (FP). It was hypothesized that femoral component rotational alignment can change based on preoperative knee phenotypes, without affecting clinical outcomes. Methods: A total of 256 patients who underwent image‐based RA‐TKA with the Mako robotic system at a single centre from February 2020 to March 2022 were included. Preoperative robotic‐derived computed tomography (CT) data were gathered to determine the Coronal Plane Alignment of the Knee (CPAK) classification and the axial orientation of the distal femur. Intraoperative data relative to femoral component rotational alignment were collected. At a minimum of 24 months post‐operatively, patients were administered the Forgotten Joint Score‐12 (FJS‐12) and the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS‐JR). The distribution of femoral component rotation among phenotypes, as well as the relationships between alignment parameters and clinical outcomes, were assessed by means of linear regression models and one‐way analysis of variance. Results: A total of 219 cruciate retaining TKAs were considered for implant positioning assessment. Femoral component rotational alignment varied significantly among different knee phenotypes, ranging from −6.9° internal to 6.6° external rotation with respect to surgical transepicondylar axis. No significant association was found between femoral component rotation and patient‐reported outcomes (FJS‐12 and KOOS‐JR). Three patients (1.4%) underwent RA‐TKA revision, while no patello‐femoral complications were reported in any of the patients. Conclusions: In the setting of image‐based RA‐TKA performed with FP, the rotational alignment of the femoral component changes significantly among different knee phenotypes. These variations do not affect clinical outcomes at a minimum of 2 years of follow‐up and do not result in significant patello‐femoral complications. Level of Evidence: Level III.


  • Change of CPAK class does not affect functional outcomes in robotic arm‐assisted total knee arthroplasty performed with functional alignment

    by Enrico Bertugli, Francesco Zambianchi, Cécile Batailler, Gabriele Bazzan, Sébastien Lustig, Fabio Catani

    Purpose: The purpose of this study was to assess the impact of post‐operative coronal plane alignment of the knee (CPAK) class change on functional outcomes and determine the rate and type of CPAK class change after image‐based robotic arm‐assisted (RA)‐total knee arthroplasty (TKA) performed with functional alignment (FA) at two different centres.Methods: The present retrospective, observational, multicentre study included 201 patients treated with RA‐TKA between October 2020 and April 2022 at two different centres. The radiographic CPAK classification was adapted using CT images to achieve pre‐ and post‐operative knee categorization into CPAK classes. At a minimum of 1 year post‐operatively, patients were administered the Forgotten Joint Score‐12 (FJS‐12) and surveyed about their post‐operative satisfaction level using a 5‐level Likert scale (5‐LLS).Results: The most common preoperative overall CPAK classes were: Types II, I, III, IV and V. Implant positioning after RA‐TKA with FA within the alignment boundaries, determined distribution in the CPAK classification, predominantly maintaining classes I, II, IV, and V. No statistically significant FJS‐12 differences were detected between subjects who maintained and changed their preoperative CPAK class. The mean 5‐LLS for satisfaction in patients where the preoperative CPAK class was maintained intraoperatively was 4.4 ± 1.1 (range = 1–5), while subjects having the CPAK class changed had a mean 5‐LLS of 4.4 ± SD 1.0 (range 1–5).Conclusion: In the setting of image‐based RA‐TKA with FA, CPAK can be changed within a ‘functional safe‐zone’, without compromising functional outcomes. Good functional outcomes are the result of a stable and balanced knee with soft‐tissue preservation, regardless of the maintenance of the preoperative CPAK class.Level of Evidence: Level III.


  • Open Access

    Stem anteversion is not affected by proximal femur geometry in robotic-assisted total hip arthroplasty

    by Andrea Marcovigi, Gianluca Grandi, Luca Bianchi, Francesco Zambianchi, Marco Pavesi, Fabio Catani

    Background: In the present study, the surgeon aimed to align the stem at 5° to 25° in anteversion. The robotic technology was used to measure stem anteversion with respect to proximal femur anteversion at different levels down the femur. Methods: A total of 102 consecutive patients underwent robotic-arm-assisted total hip arthroplasty (RTHA). 3D CT-based preoperative planning was performed to determine femoral neck version (FNV), posterior cortex anteversion (PCA), anterior cortex anteversion (ACA), and femoral metaphyseal axis anteversion (MAA) at 3 different levels: D (10 mm above lesser trochanter), E (the midpoint of the planned neck resection line) and F (head-neck junction). The robotic system was used to define and measure stem anteversion during surgery. Results: Mean FNV was 6.6° (SD: 8.8°) and the mean MAA was consistently significantly higher than FNV, growing progressively from proximal to distal. Mean SV was 16.4° (SD: 4.7°). There was no statistically significant difference (P = 0.16) between SV and MAA at the most distal measured level. In 96.1% cases, the stem was positioned inside the 5°–25° anteversion range. Conclusions: Femoral anteversion progressively increased from neck to proximal metaphysis. Aligning the stem close to femoral anteversion 10 mm above the lesser trochanter often led to the desired component anteversion.


  • Small deviations between planned and performed bone cuts using a CT‐based robotic‐arm‐assisted total knee arthroplasty system

    by Francesco Zambianchi, Nikita Matveitchouk, Marco Pavesi, Sebastiano Clemenza, Riccardo Cuoghi Costantini, Andrea Marcovigi, Stefano Seracchioli, Fabio Catani

    Purpose: Computed tomography (CT)‐based robotic system for total knee arthroplasty (TKA) has shown improved accuracy compared to conventional. This study was designed to (1) confirm the accuracy of the robotic system in achieving the plan and (2) establish the alignment and positioning deviation between final components and planning, by measuring the discrepancy between final implant alignment and the corresponding planned cut.Methods: Ninety‐six cementless robotic‐arm assisted (RA) TKAs were assessed. Bone resections were performed using the haptically controlled robotic arm. Alignment in the coronal and sagittal plane and resection depth of the distal femoral and proximal tibial cuts were recorded with a navigation planar probe. After final components were impacted, the probe was positioned on each implant surface to determine its alignment and positioning.Results: The mean tibial resections and implanted tibial component's positioning were 0.4 mm (standard deviation, SD: 0.6) and 0.9 mm (SD: 0.8), respectively, higher than planned (p < 0.01). The tibial sagittal cut had 19/96 cases (19.8%) of ±1° outliers from plan. In 40/96 cases (41.7%), the tibial component was more prominent than planned of more than 1 mm. The mean femoral resections and impacted femoral component's positioning was 0.1 mm (SD: 0.8) and 0.2 mm (SD: 0.7), respectively, higher than planned. In 23/96 cases (24.0%), the femoral sagittal cut and femoral component coronal alignment deviated more than ±1° from plan.Conclusions: The computed tomography‐based robotic‐assisted TKA system showed good accuracy regarding bone preparation and component's positioning relative to the planning. Cementless tibial component impaction resulted in the most deviation from plan, with a large proportion of cases resulting in being more prominent than planned.Level of Evidence: Level III.


  • High return to sport rate in patients undergoing image-based robotic arm assisted unicompartmental knee arthroplasty

    by Valerio Daffara, Francesco Zambianchi, Enrico Festa, Riccardo Cuoghi Costantini, Sebastiano Clemenza, Fabio Catani

    Introduction This study was aimed to assess the return to sport (RTS) rate in patients who underwent CT-based robotic-assisted unicompartmental knee arthroplasty (RA-UKA) and to evaluate the clinical performance and the assocition between patients’ sport activity levels and Patient Reported Outcome Measures after surgery. Materials and methods This retrospective study included 218 patients undergoing medial RA-UKA with fixed-bearing implants, performed at a single center between 2014 and 2019. Patients were allocated into two groups based on sport’s practice and were administered the University of California, Los Angeles (UCLA) activity scale, Forgotten Joint Score-12 (FJS-12), Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR) and the 5-Level Likert Scale. Results A total of 136 patients were included for assessment. The overall RTS rate after surgery was 93.1%. Six subjects who did not practice sport preoperatively, were able to start sport activities after surgery and all patients performing sports preoperatively, returned to same activity level. The mean UCLA and FJS-12 scores in the group of patients practicing sports were significantly higher than in the no-sport group (p < 0.001 and p < 0.05, respectively). Patients who practiced sports were more likely to attain higher FJS-12 and UCLA scores than those who were not performing physical activity. Conclusions Patients undergoing RA-UKA showed a 93.1% RTS rate after surgery. Differences were detected in terms of postoperative UCLA and FJS-12 scores between patients who performed and who did not practice sport activities after surgery. High levels of postoperative UCLA scores were associated with higher KOOS-JR and patients’ satisfaction.