MSMohammadali Safavieh

Mohammadali Safavieh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohammadali Safavieh has a total of 44 co-authors. Here are the top co-authors by number of shared publications:

  • Minhaz Uddin Ahmed

    Biosensors and Nanobiotechnology Laboratory, Integrated Science Building, Faculty of Science, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong, BE1410, Brunei Darussalam

    4 shared publications
  • Hadi Shafiee

    Division of Engineering in Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, USA

    3 shared publications
  • Anupriya Singh

    Division of Engineering in Medicine, Brigham and Women's Hospital-Harvard Medical School , 75 Francis Street, Boston, Massachusetts 02115, United States

    2 shared publications
  • Daniel R. Kuritzkes

    Division of Infectious Diseases, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, 02114, USA

    2 shared publications
  • Hardik J. Pandya

    Division of Engineering in Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, 02139, USA

    2 shared publications
  • Manjyot Kaur Chug

    Division of Engineering in Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, 02139, USA

    2 shared publications

Latest Publications

  • A Triple-Layer Amniotic Membrane Dressing Drives Robust Wound Healing: In-Depth Protein Profiling and In Vivo Validation in Rat and Human Subjects

    by Mohammadali Safavieh, H. Frank Burrows, Olivia Logan, Sadhana S. Joshi, Laura K. Rivera-Tarazona, Mora C. Melican

    In chronic ulcers, early intervention to obtain wound closure is a critical requirement for optimal reparative success. Human dried amniotic membrane (HDAM) has been widely used as a wound covering due to three characteristics: its content of highly enriched extracellular matrix (ECM) and bioactive cytokines, its long shelf life, and its suitable biomechanical properties adequate for handling in the dried state. The ECM composition can be enhanced by the creation of a sandwich composed of three distinct layers of the amniotic membrane without creating any detrimental manufacturing shortcomings or clinical procedural complications. In this study, we investigate the mechanisms of action that contribute to wound healing using the histological analysis of various proteins, which exist in tri-layer HDAM. In addition, extensive proteomic analysis of 80 cytokines and growth factors is compartmentalized and quantified based on their functions in wound healing. More importantly, the reciprocal interactions between ECM components and keratinocyte proliferation are investigated. Using an animal wound model, in vivo efficacy of the tri-layer HDAM is assessed based on wound closure, tissue granulation, and re-epithelialization rates and is compared to a no-graft group. Lastly, the therapeutic effects of tri-layer HDAM and possible adverse effects on patients are carefully recorded through conducting a clinical study with a 37-patient population. The collective results suggest that the tri-layer HDAM positively affects various critical pathways in chronic wound healing and shows no adverse effects in human clinical studies.


  • Open Access

    Recent developments towards portable point-of-care diagnostic devices for pathogen detection

    by Sharmili Roy, Fareeha Arshad, Shimaa Eissa, Mohammadali Safavieh, Sanaa G. Alattas, Minhaz Uddin Ahmed, Mohammed Zourob

    Recent developments of point-of-care (POC) diagnostic devices available for detecting pathogens to monitor infectious diseases that have made a massive impact in modern health care systems.


  • Colorimetric Nucleic Acid Detection on Paper Microchip Using Loop Mediated Isothermal Amplification and Crystal Violet Dye

    by Sharmili Roy, Noor Faizah Mohd-Naim, Mohammadali Safavieh, Minhaz Uddin Ahmed

    Nucleic acid detection is of paramount importance in monitoring of microbial pathogens in food safety and infectious disease diagnostic applications. To address these challenges, a rapid, cost-effective label-free technique for nucleic acid detection with minimal instrumentations is highly desired. Here, we present paper microchip to detect and quantify nucleic acid using colorimetric sensing modality. The extracted DNA from food samples of meat as well as microbial pathogens was amplified utilizing loop-mediated isothermal amplification (LAMP). LAMP amplicon was then detected and quantified on a paper microchip fabricated in a cellulose paper and a small wax chamber utilizing crystal violet dye. The affinity of crystal violet dye toward dsDNA and positive signal were identified by changing the color from colorless to purple. Using this method, detection of Sus scrofa (porcine) and Bacillus subtilis (bacteria) DNA was possible at concentrations as low as 1 pg/μL (3.43 × 10 –1 copies/μL) and 10 pg/μL (2.2 × 103 copies/μL), respectively. This strategy can be adapted for detection of other DNA samples, with potential for development of a new breed of simple and inexpensive paper microchip at the point-of-need.


  • Rapid, label-free CD4 testing using a smartphone compatible device

    by Manoj Kumar Kanakasabapathy, Hardik J. Pandya, Mohamed Shehata Draz, Manjyot Kaur Chug, Magesh Sadasivam, Shreya Kumar, Behzad Etemad, Vinish Yogesh, Mohammadali Safavieh, Waseem Asghar, et al.

    The most recent guidelines have called for a significant shift towards viral load testing for HIV/AIDS management in developing countries; however point-of-care (POC) CD4 testing still remains an important component of disease staging in multiple developing countries. Advancements in micro/nanotechnologies and consumer electronics have paved the way for mobile healthcare technologies and the development of POC smartphone-based diagnostic assays for disease detection and treatment monitoring. Here, we report a simple, rapid (30 minutes) smartphone-based microfluidic chip for automated CD4 testing using a small volume (30 μL) of whole blood. The smartphone-based device includes an inexpensive (<$5) cell phone accessory and a functionalized disposable microfluidic device. We evaluated the performance of the device using spiked PBS samples and HIV-infected and uninfected whole blood, and compared the microfluidic chip results with the manual analysis and flow cytometry results. Through t-tests, Bland–Altman analyses, and regression tests, we have shown a good agreement between the smartphone-based test and the manual and FACS analysis for CD4 count. The presented technology could have a significant impact on HIV management in developing countries through providing a reliable and inexpensive POC CD4 testing.


  • Rapid Real-Time Antimicrobial Susceptibility Testing with Electrical Sensing on Plastic Microchips with Printed Electrodes

    by Mohammadali Safavieh, Hardik J. Pandya, Maanasa Venkataraman, Prudhvi Thirumalaraju, Manoj Kumar Kanakasabapathy, Anupriya Singh, Devbalaji Prabhakar, Manjyot Kaur Chug, Hadi Shafiee

    Rapid antimicrobial susceptibility testing is important for efficient and timely therapeutic decision making. Due to globally spread bacterial resistance, the efficacy of antibiotics is increasingly being impeded. Conventional antibiotic tests rely on bacterial culture, which is time-consuming and can lead to potentially inappropriate antibiotic prescription and up-front broad range of antibiotic use. There is an urgent need to develop point-of-care platform technologies to rapidly detect pathogens, identify the right antibiotics, and monitor mutations to help adjust therapy. Here, we report a biosensor for rapid (Escherichia coli and methicillin-resistant Staphylococcus aureus (MRSA) as clinical models with ampicillin, ciprofloxacin, erythromycin, daptomycin, gentamicin, and methicillin antibiotics. The results are compared with the current standard methods, i.e. bacteria viability and conventional antibiogram assays. The technology presented here has the potential to provide precise and rapid bacteria screening and guidance in clinical therapies by identifying the correct antibiotics for pathogens.


  • Paper microchip with a graphene-modified silver nano-composite electrode for electrical sensing of microbial pathogens

    by Mohammadali Safavieh, Vivasvat Kaul, Sultan Khetani, Anupriya Singh, Karan Dhingra, Manoj Kumar Kanakasabapathy, Mohamed Shehata Draz, Adnan Memic, Daniel R. Kuritzkes, Hadi Shafiee

    Rapid and sensitive point-of-care diagnostics are of paramount importance for early detection of infectious diseases and timely initiation of treatment. Here, we present cellulose paper and flexible plastic chips with printed graphene-modified silver electrodes as universal point-of-care diagnostic tools for the rapid and sensitive detection of microbial pathogens or nucleic acids through utilizing electrical sensing modality and loop-mediated isothermal amplification (LAMP). We evaluated the ability of the developed paper-based assay to detect (i) viruses on cellulose-based paper microchips without implementing amplification in samples with viral loads between 106 and 108 copies per ml, and (ii) amplified HIV-1 nucleic acids in samples with viral loads between 10 fg μl−1 and 108 fg μl−1. The target HIV-1 nucleic acid was amplified using the RT-LAMP technique and detected through the electrical sensing of LAMP amplicons for a broad range of RNA concentrations between 10 fg μl−1 and 108 fg μl−1 after 40 min of amplification time. Our assay may be used for antiretroviral therapy monitoring where it meets the sensitivity requirement of the World Health Organization guidelines. Such a paper microchip assay without the amplification step may also be considered as a simple and inexpensive approach for acute HIV detection where maximum viral replication occurs.


  • Open Access

    Erratum: Two-Aperture Microfluidic Probes as Flow Dipoles: Theory and Applications

    by Mohammadali Safavieh, Mohammad A. Qasaimeh, Ali Vakil, David Juncker, Thomas Gervais

    A microfluidic probe (MFP) is a mobile channel-less microfluidic system under which a fluid is injected from an aperture into an open space, hydrodynamically confined by a surrounding fluid, and entirely re-aspirated into a second aperture. Various MFPs have been developed, and have been used for applications ranging from surface patterning of photoresists to local perfusion of organotypic tissue slices. However, the hydrodynamic and mass transfer properties of the flow under the MFP have not been analyzed, and the flow parameters are adjusted empirically. Here, we present an analytical model describing the key transport properties in MFP operation, including the dimensions of the hydrodynamic flow confinement (HFC) area, diffusion broadening, and shear stress as a function of: (i) probe geometry (ii) aspiration-to-injection flow rate ratio (iii) gap between MFP and substrate and (iv) reagent diffusivity. Analytical results and scaling laws were validated against numerical simulations and experimental results from published data. These results will be useful to guide future MFP design and operation, notably to control the MFP “brush stroke” while preserving shear-sensitive cells and tissues.


  • A flexible and low-cost polypropylene pouch for naked-eye detection of herpes simplex viruses

    by Sharifun Nahar, Minhaz Uddin Ahmed, Mohammadali Safavieh, Annie Rochette, Carla Toro, Mohammed Zourob

    Effective viral detection is a key goal in the development of point of care (POC) diagnostic devices. Loop-mediated isothermal amplification (LAMP) could potentially be a valuable tool for rapid viral detection and diagnosis in commercial and hospital laboratories and resource limited settings. Here, we present a novel polypropylene pouch (PP) for detection of HSV-1 and HSV-2. With this plastic pouch we could detect up to 6.08 × 101 copies per μL of HSV-1 DNA and 0.598 copies per μL of HSV-2 DNA within 45 minutes. Since LAMP itself is less sensitive to inhibitory substances present in the real sample, we could also detect viral DNA without the need for viral DNA extraction and purification. The result from LAMP could be evaluated by naked eye due to the addition of hydroxy naphthol blue (HNB) dye in the reaction mixture. Since this proposed device is easy to handle, portable, user friendly and low cost, it offers a tremendous potential to be a perfect candidate for POC diagnostic device for use in resource limited settings.