Domingos Souza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Domingos Souza has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Ninos Samano
University Health Care Research Centre, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
7 shared publications Håkan Geijer
Department of Radiology, Faculty of Medicine and Health, Örebro University
5 shared publications- Gabriele Ferrari
University Health Care Research Centre, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
3 shared publications Lennart Bodin
Unit of Intervention and Implementation Research, Institute of Environmental Medicine, Karolinska Institute, Stockholm, Sweden
3 shared publications- Michael Richard Dashwood
Surgical and Interventional Sciences, Royal Free Hospital Campus, University College Medical School, London NW3 2PF, UK
3 shared publications Bruno Botelho Pinheiro
Department of Cardiovascular Surgery, Hospital do Coração Anis Rassi, Goiânia, Goiás, Brazil
2 shared publications
Latest Publications
- Open Access
Superior long-term patency of no-touch vein graft compared to conventional vein grafts in over 1500 consecutive patients
Objectives To evaluate the long-term angiographic patency of saphenous vein grafts (SVG) harvested using the no-touch technique compared to the conventional technique. Methods This was a single-center, retrospective, cohort study. The inclusion criteria were individuals who underwent a CABG (coronary artery bypass grafting) between January 1995 and July 2020, and who successively needed a clinically-driven angiography. The primary endpoint was long-term patency. The secondary endpoints were differences in patency based on sub-group analysis (single vs. sequential graft, divided by target vessel). Results The study included 1520 individuals (618 no-touch, 825 conventional and 77 arterial grafts). The mean clinical follow-up time was 8.4 years ± 5.5 years. The patency per patient was 70.7% in the no-touch grafts vs. 46.7% in the conventional grafts (p < 0.001, OR = 2.8). The graft patency was 75.9% in the no-touch grafts vs. 62.8% in the conventional grafts (p < 0.001, OR= 1.8). Conclusions The no-touch vein grafts were associated with statistically significantly higher patency at long-term compared to the conventional grafts. Clinical Trial Registration NCT04656366, 7 December 2020 Clinical Perspective - What is new? ➣ The largest follow-up of the patency of no-touch vein grafts in the international literature. ➣ Patients with a no-touch vein graft had significantly better patency (p < 0.001) at mean follow-up of more than 8 years. - What are the clinical implications? ➣ Consequent reduction in cardiovascular events after no-touch vein graft. ➣ Benefits at individual level due to fewer episodes of re-angina and myocardial infarction, and fewer coronary interventions. ➣ Benefits at community level due to fewer re-hospitalizations and a reduction in healthcare costs.
Open AccessSuperior long-term patency of no-touch vein graft compared to conventional vein grafts in over 1500 consecutive patients
Objectives To evaluate the long-term angiographic patency of saphenous vein grafts (SVG) harvested using the no-touch technique compared to the conventional technique. Methods This was a single-center, retrospective, cohort study. The inclusion criteria were individuals who underwent a CABG (coronary artery bypass grafting) between January 1995 and July 2020, and who successively needed a clinically-driven angiography. The primary endpoint was long-term patency. The secondary endpoints were differences in patency based on sub-group analysis (single vs. sequential graft, divided by target vessel). Results The study included 1520 individuals (618 no-touch, 825 conventional and 77 arterial grafts). The mean clinical follow-up time was 8.4 years ± 5.5 years. The patency per patient was 70.7% in the no-touch grafts vs. 46.7% in the conventional grafts (p < 0.001, OR = 2.8). The graft patency was 75.9% in the no-touch grafts vs. 62.8% in the conventional grafts (p < 0.001, OR= 1.8). Conclusions The no-touch vein grafts were associated with statistically significantly higher patency at long-term compared to the conventional grafts. Clinical Trial Registration NCT04656366, 7 December 2020 Clinical Perspective - What is new? ➣ The largest follow-up of the patency of no-touch vein grafts in the international literature. ➣ Patients with a no-touch vein graft had significantly better patency (p < 0.001) at mean follow-up of more than 8 years. - What are the clinical implications? ➣ Consequent reduction in cardiovascular events after no-touch vein graft. ➣ Benefits at individual level due to fewer episodes of re-angina and myocardial infarction, and fewer coronary interventions. ➣ Benefits at community level due to fewer re-hospitalizations and a reduction in healthcare costs.
- Open Access
- 15 June 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 62 (1)
Saphenous vein harvesting for CABG: wear a VEST or keep the fat?
Michael R Dashwood, Ninos Samano, Domingos S Souza; Saphenous vein harvesting for CABG: wear a VEST or keep the fat?, European Journal of Cardio-Thoracic Surger
- 15 June 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 62 (1)
Open AccessSaphenous vein harvesting for CABG: wear a VEST or keep the fat?
Michael R Dashwood, Ninos Samano, Domingos S Souza; Saphenous vein harvesting for CABG: wear a VEST or keep the fat?, European Journal of Cardio-Thoracic Surger
- 1 February 2022
- Published by Wolters Kluwer Health in Circulation
- Vol. 145 (5) , 319-320
Thirty Years of No-Touch Saphenous Vein Harvesting: A Timely Jubilee Gift
- 1 February 2022
- Published by Wolters Kluwer Health in Circulation
- Vol. 145 (5) , 319-320
Thirty Years of No-Touch Saphenous Vein Harvesting: A Timely Jubilee Gift
- Open Access
- 1 January 2022
- Published by Sociedade Brasileira de Cirurgia Cardiovascular in Brazilian Journal of Cardiovascular Surgery
- Vol. 37 (4) , 430-438
Quality of Life After Percutaneous Coronary Intervention in No-Touch Saphenous Vein Grafts is Significantly Better Than in Conventional Vein Grafts
To compare health-related quality of life (HRQoL) of patients primarily treated with a no-touch saphenous vein graft with that of patients who received a conventional graft. The study included all individuals treated with a percutaneous coronary intervention (PCI) on a saphenous vein graft (SVG) between January 2006 and June 2020. The RAND-36 health survey was used to assess HRQoL. The Mann-Whitney U test was used to test differences in HRQoL between the two groups. Effect size was estimated via Cohen’s d. The average treatment effect between the groups was tested by propensity score matching (PSM). Of the 346 patients treated with a PCI in a stenosed or occluded SVG, 165 responded to RAND-36 (no-touch: n=48; conventional: n=117). Patients with a no-touch graft reported better mean values on seven of the eight health survey domains. Statistically significant differences were observed for four of the domains, all in favour of the no-touch group. The effect size estimates indicated a small difference for five domains, with the highest values (>0.40) seen for the general health and energy/fatigue domains. PSM confirmed a statistically significant difference for the physical functioning and general health domains. At a mean follow-up of 5.4 years, patients who received a PCI in no-touch vein grafts showed significantly better HRQoL than those who received a PCI in conventional vein grafts.
- 1 January 2022
- Published by Sociedade Brasileira de Cirurgia Cardiovascular in Brazilian Journal of Cardiovascular Surgery
- Vol. 37 (4) , 430-438
Open AccessQuality of Life After Percutaneous Coronary Intervention in No-Touch Saphenous Vein Grafts is Significantly Better Than in Conventional Vein Grafts
To compare health-related quality of life (HRQoL) of patients primarily treated with a no-touch saphenous vein graft with that of patients who received a conventional graft. The study included all individuals treated with a percutaneous coronary intervention (PCI) on a saphenous vein graft (SVG) between January 2006 and June 2020. The RAND-36 health survey was used to assess HRQoL. The Mann-Whitney U test was used to test differences in HRQoL between the two groups. Effect size was estimated via Cohen’s d. The average treatment effect between the groups was tested by propensity score matching (PSM). Of the 346 patients treated with a PCI in a stenosed or occluded SVG, 165 responded to RAND-36 (no-touch: n=48; conventional: n=117). Patients with a no-touch graft reported better mean values on seven of the eight health survey domains. Statistically significant differences were observed for four of the domains, all in favour of the no-touch group. The effect size estimates indicated a small difference for five domains, with the highest values (>0.40) seen for the general health and energy/fatigue domains. PSM confirmed a statistically significant difference for the physical functioning and general health domains. At a mean follow-up of 5.4 years, patients who received a PCI in no-touch vein grafts showed significantly better HRQoL than those who received a PCI in conventional vein grafts.
- Open Access
- 1 January 2022
- Published by Sociedade Brasileira de Cirurgia Cardiovascular in Brazilian Journal of Cardiovascular Surgery
- Vol. 37 (1) , 135-138
A Case of Using No-Touch Saphenous Vein Graft in Redo CABG after Multiple Failed Percutaneous Coronary Interventions
The modality of repeat revascularization due to late graft failure is a debated topic. The latest available European guidelines recommend redo coronary artery bypass graft (CABG) for cases of extensively diseased and/or occluded grafts and those with diffuse native vessel disease. We present the case of a patient being relieved of recurrent unstable angina pectoris with redo CABG using no-touch saphenous vein grafts after repeated and unsuccessful attempts with percutaneous coronary intervention (PCI). This could be an alternative to PCI in patients with a complex medical history. Teamwork between cardiologists and surgeons is pivotal in deciding the best treatment modality.
- 1 January 2022
- Published by Sociedade Brasileira de Cirurgia Cardiovascular in Brazilian Journal of Cardiovascular Surgery
- Vol. 37 (1) , 135-138
Open AccessA Case of Using No-Touch Saphenous Vein Graft in Redo CABG after Multiple Failed Percutaneous Coronary Interventions
The modality of repeat revascularization due to late graft failure is a debated topic. The latest available European guidelines recommend redo coronary artery bypass graft (CABG) for cases of extensively diseased and/or occluded grafts and those with diffuse native vessel disease. We present the case of a patient being relieved of recurrent unstable angina pectoris with redo CABG using no-touch saphenous vein grafts after repeated and unsuccessful attempts with percutaneous coronary intervention (PCI). This could be an alternative to PCI in patients with a complex medical history. Teamwork between cardiologists and surgeons is pivotal in deciding the best treatment modality.
- Open Access
- 18 March 2021
- Published by Taylor & Francis in Scandinavian Cardiovascular Journal
- Vol. 55 (4) , 245-253
Percutaneous coronary intervention in saphenous vein grafts after coronary artery bypass grafting: a systematic review and meta-analysis
To investigate the results of percutaneous coronary intervention (PCI) in saphenous vein grafts after coronary artery bypass grafting (CABG). Design. MEDLINE, Embase, and the Cochrane library were ...
- 18 March 2021
- Published by Taylor & Francis in Scandinavian Cardiovascular Journal
- Vol. 55 (4) , 245-253
Open AccessPercutaneous coronary intervention in saphenous vein grafts after coronary artery bypass grafting: a systematic review and meta-analysis
To investigate the results of percutaneous coronary intervention (PCI) in saphenous vein grafts after coronary artery bypass grafting (CABG). Design. MEDLINE, Embase, and the Cochrane library were ...
- 1 February 2021
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 161 (2) , 624-630
The no-touch saphenous vein is an excellent alternative conduit to the radial artery 8 years after coronary artery bypass grafting: A randomized trial
- 1 February 2021
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 161 (2) , 624-630
The no-touch saphenous vein is an excellent alternative conduit to the radial artery 8 years after coronary artery bypass grafting: A randomized trial
- Open Access
- 1 January 2021
- Published by Sociedade Brasileira de Cirurgia Cardiovascular in Brazilian Journal of Cardiovascular Surgery
- Vol. 36 (5) , 1-3
The “No-touch” Harvesting Technique Revives the Position of the Saphenous Vein as an Important Conduit in CABG Surgery: 30-year Anniversary
- 1 January 2021
- Published by Sociedade Brasileira de Cirurgia Cardiovascular in Brazilian Journal of Cardiovascular Surgery
- Vol. 36 (5) , 1-3
Open AccessThe “No-touch” Harvesting Technique Revives the Position of the Saphenous Vein as an Important Conduit in CABG Surgery: 30-year Anniversary
- Open Access
- 17 December 2020
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 29 (6) , 490-497
Pedicled versus skeletonized internal thoracic artery grafts: a randomized trial
Concerns have been raised regarding whether skeletonization of the internal thoracic artery could damage the graft and thereby reduces its patency. The objective of this study was to compare patency rates at mid- and long-term follow-up between pedicled and skeletonized left internal thoracic artery grafts. This randomized controlled trial included 109 patients undergoing coronary artery bypass surgery. The patients were assigned to receive either one pedicled or one skeletonized left internal thoracic artery graft to the left anterior descending artery. Follow-up was performed at 3 years with conventional angiography, and at 8 years with computed tomography angiography. Differences between patency rates were analyzed with Fisher’s exact test and a generalized linear model. The patency rates for pedicled and skeletonized left internal thoracic artery grafts were 46/48 (95.8%) versus 47/52 (90.4%), p = 0.44 at 3 years, and 40/43 (93.0%) versus 37/41 (90.2%), p = 0.71 at 8 years, respectively. The difference in patency rates for pedicled and skeletonized grafts was 5.4% (95% confidence interval: −4.2–14.5) at 3 years and 2.8% (95% confidence interval: −9.9–14.1) at 8 years. All failed grafts, except for one with a localized stenosis, were anastomosed to native coronary arteries with a stenosis less than 70%. Three patients suffered sternal wound infections (two in the pedicled group, one in the skeletonized group). The skeletonization technique can be used without jeopardizing the patency of the left internal thoracic artery. The most important factor in graft failure was target artery stenosis below 70%.
- 17 December 2020
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 29 (6) , 490-497
Open AccessPedicled versus skeletonized internal thoracic artery grafts: a randomized trial
Concerns have been raised regarding whether skeletonization of the internal thoracic artery could damage the graft and thereby reduces its patency. The objective of this study was to compare patency rates at mid- and long-term follow-up between pedicled and skeletonized left internal thoracic artery grafts. This randomized controlled trial included 109 patients undergoing coronary artery bypass surgery. The patients were assigned to receive either one pedicled or one skeletonized left internal thoracic artery graft to the left anterior descending artery. Follow-up was performed at 3 years with conventional angiography, and at 8 years with computed tomography angiography. Differences between patency rates were analyzed with Fisher’s exact test and a generalized linear model. The patency rates for pedicled and skeletonized left internal thoracic artery grafts were 46/48 (95.8%) versus 47/52 (90.4%), p = 0.44 at 3 years, and 40/43 (93.0%) versus 37/41 (90.2%), p = 0.71 at 8 years, respectively. The difference in patency rates for pedicled and skeletonized grafts was 5.4% (95% confidence interval: −4.2–14.5) at 3 years and 2.8% (95% confidence interval: −9.9–14.1) at 8 years. All failed grafts, except for one with a localized stenosis, were anastomosed to native coronary arteries with a stenosis less than 70%. Three patients suffered sternal wound infections (two in the pedicled group, one in the skeletonized group). The skeletonization technique can be used without jeopardizing the patency of the left internal thoracic artery. The most important factor in graft failure was target artery stenosis below 70%.
- Open Access
- 1 January 2020
- Published by Sociedade Brasileira de Cirurgia Cardiovascular in Brazilian Journal of Cardiovascular Surgery
- Vol. 35 (1) , 91-99
Twenty-Five Years of No-Touch Saphenous Vein Harvesting for Coronary Artery Bypass Grafting: Structural Observations and Impact on Graft Performance
The saphenous vein is the most common conduit used in coronary artery bypass grafting (CABG) yet its failure rate is higher compared to arterial grafts. An improvement in saphenous vein graft performance is therefore a major priority in CABG. No-touch harvesting of the saphenous vein is one of the few interventions that has shown improved patency rates, comparable to that of the left internal thoracic artery. After more than two decades of no-touch research, this technique is now recognized as a Class IIa recommendation in the 2018 European Society of Cardiology and the European Association for Cardio-Thoracic Surgery guidelines on myocardial revascularization. In this review, we describe the structural alterations that occur in conventional versus no-touch saphenous vein grafts and how these changes affect graft patency. In addition, we discuss various strategies aimed at repairing saphenous vein grafts prepared at conventional CABG.
- 1 January 2020
- Published by Sociedade Brasileira de Cirurgia Cardiovascular in Brazilian Journal of Cardiovascular Surgery
- Vol. 35 (1) , 91-99
Open AccessTwenty-Five Years of No-Touch Saphenous Vein Harvesting for Coronary Artery Bypass Grafting: Structural Observations and Impact on Graft Performance
The saphenous vein is the most common conduit used in coronary artery bypass grafting (CABG) yet its failure rate is higher compared to arterial grafts. An improvement in saphenous vein graft performance is therefore a major priority in CABG. No-touch harvesting of the saphenous vein is one of the few interventions that has shown improved patency rates, comparable to that of the left internal thoracic artery. After more than two decades of no-touch research, this technique is now recognized as a Class IIa recommendation in the 2018 European Society of Cardiology and the European Association for Cardio-Thoracic Surgery guidelines on myocardial revascularization. In this review, we describe the structural alterations that occur in conventional versus no-touch saphenous vein grafts and how these changes affect graft patency. In addition, we discuss various strategies aimed at repairing saphenous vein grafts prepared at conventional CABG.