RMRagaa Magdy

Ragaa Magdy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ragaa Magdy has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Determination of Sacubitril and Valsartan Binary Mixture using Different Eco-friendly Spectrophotometric approaches with or without Regression Equations; greenness and whiteness assessments

    by Ragaa Magdy, Ahmed Hemdan, Maha F. Abdel Ghany, Nermine V Fares

    One of the leading causes of illness and mortality worldwide is cardiovascular disease. The optimum therapy in the majority of cases is accomplished by combining a number of medications, each of which has a unique mechanism of action, to treat cardiovascular disease. Entresto® tablet combines Sacubitril (SAC) and Valsartan (VAL), It is proposed to lessen the risk of cardiovascular hospitalization and heart failure-related death in those with chronic heart failure and a lower ejection fraction. The aim that initiated the work was to develop Eco- friendly sustainable spectrophotometric methods that can be employed as an environmentally friendly alternative to the methods previously reported for SAC/VAL combinations. The suggested spectrophotometric methods are constant value (CV), concentration value (CNV), Absorption subtraction (AS), and Amplitude modulation (AM). Six evaluation tools were used to evaluate the greenness and whiteness of the developed methods in order to ensure their qualitative and quantitative safety to both humans and the environment; namely, National Environmental Methods Index, the analytical eco-scale, Green Analytical Procedure Index, complementary green analytical procedure index and the Analytical GREEnness metric, and by Whiteness tool for assessing analytical chemistry method. The suggested spectrophotometric methods were successfully applied to the studied mixture. Because the zero-order spectra were directly computed without the need for any separation stages, the established concentration value approach could identify both medications without the usage of regression equations. Additionally, depending on the iso-absorptive point, both analytes could be determined via the Absorbance Subtraction and Amplitude Modulation procedures using their same regression equation.

  • A Novel, Sustainable, and Eco-Friendly Spectrophotometric and Chemometric Approach for Determination of Severely Overlapped Spectrum via Unified Regression Equation: Greenness and Whiteness Assessment

    by Ragaa Magdy, Nermine V Fares, Maha Farouk, Ahmed Hemdan

    Background: Nebivolol and valsartan (VAL) in combination with each other successfully control blood pressure and improve hypertension patient outcomes. Objective: To develop and validate innovative, simple, and sustainable spectrophotometric methods for the simultaneous analysis of nebivolol and valsartan. Method: The new modified difference amplitude modulation (MD-AM) method uses only unified regression equation and does not require any resolution techniques. Other different approaches were also applied for the determination of the same mixture including univariate and multivariate spectrophotometric methods. The multivariate methods were PLS and PCR, whereas the univariate methods were derivative ratio (DD1), ratio difference (RD), constant center (CC), constant center spectrum subtraction (CC-SS), constant value coupled with amplitude difference (CV-AD), advanced concentration value (ACV), and amplitude difference (AD). The proposed methods use a green solvent; thus, the environmental impact of the presented procedures was evaluated qualitatively and quantitatively using six well-known evaluation tools. Results: All methods were applied successfully for the analysis of the studied drugs in their bulk powder, pharmaceutical dosage form Byvalson®, and in vitro release at intestinal pH (7.4) using a USP dissolution tester. Results obtained were compared statistically with the reported method and with each other using a one-way ANOVA statistical test, and no significant differences were found. Conclusions: All green and white analytical chemistry evaluation tools results confirm the safety, sustainability, and cost-effectiveness of the approaches, indicating that the methods are regarded green and sustainable. Results were agreeable, encouraging their applicability in quality control laboratories for dosage form and making these methods an eco-friendly substitute for the analysis of this combined dosage form and for evaluating the dissolution profile. Highlights: For the first time, a severely overlapped spectrum was determined using a unified regression equation without the need of extended part or zero contribution regions by the novel method MD-AM. The proposed methods are the first study of in vitro dissolution profiling of nebivolol hydrochloride (NEB) and VAL and the first sustainable and green methods applied without compromising the analytical criteria.


  • In Vitro Dissolution Profile of Antihypertensive Mixture: Comparison Between Multivariate Methods and Statistical and Graphical Representation of Different Univariate Spectrophotometric Data

    by Ragaa Magdy, Ahmed Hemdan, Maha Farouk, Nermine V Fares

    Background: Triplixam® is a new antihypertensive drug combination consisting of perindopril, amlodipine, and indapamide, which have a synergistic mechanism of action in combination with each other. Objective: Comparative study of different spectrophotometric approaches used for the simultaneous determination of perindopril, indapamide, and amlodipine in bulk powder and in dosage form Triplixam. Method: The methods include univariate and multivariate spectrophotometric methods depending on either mathematical calculation or graphical representation of data. For the univariate methods: perindopril was resolved from other components using constant multiplication followed by spectrum subtraction resolution technique, and then two base point, AUC, constant value, and concentration value (CNV) methods were applied. For both amlodipine and indapamide: constant multiplication resolution technique was used, and then constant value and CNV methods were applied. CNV depends on graphical representation of data rather than statistical data. PLS and PCR chemometric assisted spectrophotometric techniques were also applied. The proposed methods are considered a green alternative to the reported methods as the greenness of the proposed methods was evaluated qualitatively and quantitatively by four green analytical evaluation tools. Results: The methods were applied for the analysis of the mixture in the pharmaceutical dosage form Triplixam and in vitro release at intestinal pH (7.4) using a USP dissolution tester. Conclusions: The proposed green analytical methods are considered to be greener than the reported methods and simpler, so they could be used as an alternative for routine analysis of the mixture in quality control laboratories for the reason of their accurate results beside minimum manipulation steps that reduced the error and time required of the analysis with no harmful effect on analyst health as well as the environment. Highlights: The study was the first in vitro dissolution profiling of perindopril, amlodipine, and indapamide. The developed methods were excellent green methods without compromising the analytical criteria.


  • Open Access

    Application of two different spectrophotometric approaches for the determination of a new antihypertensive combination: Graphical and statistical representation of the data

    by Ragaa Magdy, Ahmed Hemdan, Nermine Victor Fares, Maha Farouk

    Specific, and precise spectrophotometric methods are developed and validated for the simultaneous determination of the binary antihypertensive mixture nebivolol hydrochloride and valsartan in the zero-order spectrum. The methods applied for the determination of this antihypertensive mixture are constant center spectrophotometric resolution technique, constant center spectrum subtraction resolution technique, and advanced concentration value. Nebivolol hydrochloride was determined by its zero order spectra at 280 and 213 nm while for valsartan it determined by its zero order spectra at 250 nm. All developed methods were applied for the determination of the cited drugs in the pharmaceutical formulation and the results obtained were statistically compared with each other and with those of the reported method. The comparison showed that there is no significant difference between the proposed methods and the reported method regarding both accuracy and precision.


  • Open Access

    Simultaneous spectrophotometric determination of drugs lacking peak maxima in their zero-order profiles by graphical or statistical representation of data

    by Ragaa Magdy, Ahmed Hemdan, Nermine Victor Fares, Maha Farouk

    Trandolapril has no sharp peak in its zero-order spectrum, therefore it is difficult to be measured by direct spectrophotometry. In this study, direct univariate spectrophotometric methods were developed and validated for determination of Trandolapril and Verapamil combination in pure and tablet dosage forms. The first method for measuring both Trandolapril and Verapamil is Absorbance Subtraction (AS), this method depends on the presence of iso-absorptive point in the zero-order curve at 217 nm. It has the advantage of measuring the concentration of both Trandolapril and Verapamil from unified regression equation at the iso-absorptive point. The second, third and fourth methods were applied on the first order spectra of the studied drugs. Second method is Derivative Subtraction (DS) for Trandolapril and Derivative subtraction followed by spectrum subtraction (DS-SS) for Verapamil. The third and fourth methods are constant value and concentration value methods. In the concentration value method, the concentration of the drugs is determined from the graphical representation without the use of regression equations. All the developed methods were validated as per International Conference on Harmonization guidelines and the results proved that the developed methods are simple, accurate, and selective. Moreover, a statistical comparison between the developed methods and a reference method was done. Also, One-way ANOVA statistical test was done between all the proposed spectrophoto-metric methods and results showed no significant differences.