Le-Ren Chang-Chien
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Le-Ren Chang-Chien has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
Chun-Hsun Wu
Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan
8 shared publicationsChin-Chung Wu
Taiwan Power Company, Taipei, Taiwan
5 shared publicationsYao-Ching Yin
Power division of TSMC, Tainan, Taiwan
4 shared publicationsYen-Chia Chu
ECE Dept., Polytechnic School of Engineering, New York University
4 shared publications- Nabi Sertac Artan
Department of Electrical and Computer Engineering, New York Institute of Technology
3 shared publications Wei-Jen Lee
University of Texas at Arlington, Arlington, TX, USA
3 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (6) , 10111-10119
Pre-Op Diagnostics of Power Switch in Three-Phase Full-Bridge Inverters
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (6) , 10111-10119
Pre-Op Diagnostics of Power Switch in Three-Phase Full-Bridge Inverters
- 25 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Digital Slope Compensation Framework for Achieving Robust Frequency and Voltage Regulation in Ripple-Controlled Buck Converters with Very Low-ESR Output Capacitors
This paper presents a ripple controlled buck converter with fully digital slope-compensation technique to achieve adaptive voltage and frequency regulation. The unique advantage of the proposed digital slope-compensation framework lies in its ability to adaptively adjust the compensation slope, which can be effectively applied to overcome the major challenges of ripple-based control, including voltage stability with low-ESR output capacitors, voltage quality (offset and ripple), switching-frequency variation, and slow transient response. As such, the framework provides a comprehensive control solution that overcomes the key limitations inherent to ripple-based control. The proposed digital control was implemented in a buck converter with input and output voltages set at 4.2V and 1.2V, respectively, utilizing an output capacitor with an ESR of only 5mΩ. Experimental testing encompassed a load current variation range spanning from 100 to 800mA. Results demonstrate exceptional stability in switching frequency, exhibiting a mere 0.2% variation (1.49kHz/A). The voltage offset is minimized to 1.25%. Furthermore, the transient acceleration significantly reduces both rising and falling transient responses from 20μs to within 10μs, while concurrently decreasing overshoot and undershoot voltages by 42% and 34%, respectively.
- 25 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Digital Slope Compensation Framework for Achieving Robust Frequency and Voltage Regulation in Ripple-Controlled Buck Converters with Very Low-ESR Output Capacitors
This paper presents a ripple controlled buck converter with fully digital slope-compensation technique to achieve adaptive voltage and frequency regulation. The unique advantage of the proposed digital slope-compensation framework lies in its ability to adaptively adjust the compensation slope, which can be effectively applied to overcome the major challenges of ripple-based control, including voltage stability with low-ESR output capacitors, voltage quality (offset and ripple), switching-frequency variation, and slow transient response. As such, the framework provides a comprehensive control solution that overcomes the key limitations inherent to ripple-based control. The proposed digital control was implemented in a buck converter with input and output voltages set at 4.2V and 1.2V, respectively, utilizing an output capacitor with an ESR of only 5mΩ. Experimental testing encompassed a load current variation range spanning from 100 to 800mA. Results demonstrate exceptional stability in switching frequency, exhibiting a mere 0.2% variation (1.49kHz/A). The voltage offset is minimized to 1.25%. Furthermore, the transient acceleration significantly reduces both rising and falling transient responses from 20μs to within 10μs, while concurrently decreasing overshoot and undershoot voltages by 42% and 34%, respectively.
- Open Access
- 23 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 135351-135364
Digital Adaptive On-Time and Transient-Optimized Ripple Controlled Buck Converter
Ripple-based buck converters often encounter issues of operating frequency variation, system stability, and steady-state voltage error, leading to degradation in voltage regulation performance. While analog controls are commonly employed to address these issues, they still face challenges due to process uncertainty and component parameter drifting caused by chip aging. In contrast, digital controls are more able to immune to the challenges that analog circuits faced. However, the sampling rate and analog-to-digital conversion (ADC) are the two shortfalls that degrade circuit response time compared to that of the analog circuits. The weakness is being improved by design flexibility and algorithms. This paper introduces a novel approach utilizing a digital approach to reduce the variation of operating frequency to very low range, which is called digital constant frequency (DCF) control. Additionally, the digital transient-optimized control (DTOC) is proposed to significantly shorten the transient settling time. The digital control does not need to use the ADC. Given the load current change between 100 and 500mA, the DCF control reduced the operating frequency variation from 40% to 2.8%. Furthermore, the DTOC significantly shortened the settling time for both the rising and falling responses by 60% compared to the converter without DTOC.
- 23 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 135351-135364
Open AccessDigital Adaptive On-Time and Transient-Optimized Ripple Controlled Buck Converter
Ripple-based buck converters often encounter issues of operating frequency variation, system stability, and steady-state voltage error, leading to degradation in voltage regulation performance. While analog controls are commonly employed to address these issues, they still face challenges due to process uncertainty and component parameter drifting caused by chip aging. In contrast, digital controls are more able to immune to the challenges that analog circuits faced. However, the sampling rate and analog-to-digital conversion (ADC) are the two shortfalls that degrade circuit response time compared to that of the analog circuits. The weakness is being improved by design flexibility and algorithms. This paper introduces a novel approach utilizing a digital approach to reduce the variation of operating frequency to very low range, which is called digital constant frequency (DCF) control. Additionally, the digital transient-optimized control (DTOC) is proposed to significantly shorten the transient settling time. The digital control does not need to use the ADC. Given the load current change between 100 and 500mA, the DCF control reduced the operating frequency variation from 40% to 2.8%. Furthermore, the DTOC significantly shortened the settling time for both the rising and falling responses by 60% compared to the converter without DTOC.
- 1 May 2023
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Journal of Industry Applications
- Vol. 12 (3) , 244-253
Implementation and Applications of Grid-Forming Inverter with SiC for Power Grid Conditioning
Sustainable energy technologies have become promising solutions to global warming and climate change. Operation of the electric power grid has been dominated in the past by synchronous generation, wherein conventional sustainable energy inverters are designed simply to feed maximum real power into the grid. With the increasing penetration of renewable energy, it is undergoing a rapid shift toward the power generation of inverter-based resources (IBRs). As a result, transitioning to a power grid with more IBRs requires introducing advanced inverter technology that can respond to various disturbances in frequency and voltage occurring on the grid. The grid-forming (GFM) inverter equipped with an energy storage system featuring frequency and voltage support functionalities is vital for the stability of the micro power grid system. The GFM inverter also offers PV output smoothing, low voltage ride through, and low frequency ride through. In addition, the GFM inverter functions as a voltage source inverter to supply energy under off-grid state when the main grid is in fault conditions. A SiC-based 30 kVA GFM inverter is presented with a 3-phase 3-level neutral-point-clamped (NPC) topology for high-frequency operation to achieve high efficiency and power density. Designchallenges in gate driver design, PCB layout, and thermal consideration are addressed. The performances of the designated GFMinverter are measured and tested under on-grid and off-grid operations to verify the functionalities of the advanced inverter, as well.
- 1 May 2023
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Journal of Industry Applications
- Vol. 12 (3) , 244-253
Implementation and Applications of Grid-Forming Inverter with SiC for Power Grid Conditioning
Sustainable energy technologies have become promising solutions to global warming and climate change. Operation of the electric power grid has been dominated in the past by synchronous generation, wherein conventional sustainable energy inverters are designed simply to feed maximum real power into the grid. With the increasing penetration of renewable energy, it is undergoing a rapid shift toward the power generation of inverter-based resources (IBRs). As a result, transitioning to a power grid with more IBRs requires introducing advanced inverter technology that can respond to various disturbances in frequency and voltage occurring on the grid. The grid-forming (GFM) inverter equipped with an energy storage system featuring frequency and voltage support functionalities is vital for the stability of the micro power grid system. The GFM inverter also offers PV output smoothing, low voltage ride through, and low frequency ride through. In addition, the GFM inverter functions as a voltage source inverter to supply energy under off-grid state when the main grid is in fault conditions. A SiC-based 30 kVA GFM inverter is presented with a 3-phase 3-level neutral-point-clamped (NPC) topology for high-frequency operation to achieve high efficiency and power density. Designchallenges in gate driver design, PCB layout, and thermal consideration are addressed. The performances of the designated GFMinverter are measured and tested under on-grid and off-grid operations to verify the functionalities of the advanced inverter, as well.
- Open Access
- 11 March 2022
- Published by MDPI AG in Electronics
- Vol. 11 (6) , 886
Digital Implementation of Harmonic and Unbalanced Load Compensation for Voltage Source Inverter to Operate in Grid Forming Microgrid
Voltage source inverter (VSI) is a good candidate for grid forming microgrid because it provides constant amplitude, frequency, and sinusoidal shape voltage at point of common coupling (PCC). As the microgrid is separated from utility grid, voltage quality of the PCC is easily affected by the type of load. To ensure power quality in grid operation, a three-phase VSI providing automatic voltage compensation for unbalanced or nonlinear load is presented in this paper. To maintain voltage quality at a certain level, the Fast Fourier Transform (FFT) algorithm is embedded in a proportional-resonant (PR) controller to mitigate the total harmonic distortion (THD) at PCC. In the meantime, any change of voltage magnitude that is caused by the unbalanced load could be reduced as well. To further enhance the transient response with the change of load, a predictive current (PC) controller is integrated into the PR controller. All the control strategies are implemented by digital approach. The effectiveness of proposed controls is verified through experiments on a testbed of the three-phase stand-alone system.
- 11 March 2022
- Published by MDPI AG in Electronics
- Vol. 11 (6) , 886
Open AccessDigital Implementation of Harmonic and Unbalanced Load Compensation for Voltage Source Inverter to Operate in Grid Forming Microgrid
Voltage source inverter (VSI) is a good candidate for grid forming microgrid because it provides constant amplitude, frequency, and sinusoidal shape voltage at point of common coupling (PCC). As the microgrid is separated from utility grid, voltage quality of the PCC is easily affected by the type of load. To ensure power quality in grid operation, a three-phase VSI providing automatic voltage compensation for unbalanced or nonlinear load is presented in this paper. To maintain voltage quality at a certain level, the Fast Fourier Transform (FFT) algorithm is embedded in a proportional-resonant (PR) controller to mitigate the total harmonic distortion (THD) at PCC. In the meantime, any change of voltage magnitude that is caused by the unbalanced load could be reduced as well. To further enhance the transient response with the change of load, a predictive current (PC) controller is integrated into the PR controller. All the control strategies are implemented by digital approach. The effectiveness of proposed controls is verified through experiments on a testbed of the three-phase stand-alone system.
- Open Access
- 13 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 100934-100943
A Supervised Learning Scheme for Evaluating Frequency Nadir and Fast Response Reserve in Ancillary Service Market
Power system operators evaluate the frequency security of the system by predicting the frequency nadir, which is assumed to indicate the impact of a sudden loss of a generating resource. Recently, frequency nadir prediction has become more challenging because renewables have penetrated and significantly changed the generation portfolio within the system. Conventionally, the frequency nadir is determined using a frequency response model where the features—load damping, system inertia, and effective governor response—are assumed to be known. However, these key features are not easily obtained in a power system that continuously changes during daily operation. This study proposes a supervised learning scheme that traces these key features. It also proposes a new feature—the power gap rate—that better reflects the influence of the load on the system frequency than that of the load damping. Feature importance recognition and the construction of a frequency nadir model (FNM) are realized using the proposed supervised learning scheme. The proposed FNM achieved 54% higher accuracy than the conventional method. Finally, the FNM is implemented in a planning process that quantifies the capacity of the fast responsive reserve (FRR). In two renewable penetration cases, the proposed FRR procurement successfully secured the frequency nadir above the security criterion.
- 13 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 100934-100943
Open AccessA Supervised Learning Scheme for Evaluating Frequency Nadir and Fast Response Reserve in Ancillary Service Market
Power system operators evaluate the frequency security of the system by predicting the frequency nadir, which is assumed to indicate the impact of a sudden loss of a generating resource. Recently, frequency nadir prediction has become more challenging because renewables have penetrated and significantly changed the generation portfolio within the system. Conventionally, the frequency nadir is determined using a frequency response model where the features—load damping, system inertia, and effective governor response—are assumed to be known. However, these key features are not easily obtained in a power system that continuously changes during daily operation. This study proposes a supervised learning scheme that traces these key features. It also proposes a new feature—the power gap rate—that better reflects the influence of the load on the system frequency than that of the load damping. Feature importance recognition and the construction of a frequency nadir model (FNM) are realized using the proposed supervised learning scheme. The proposed FNM achieved 54% higher accuracy than the conventional method. Finally, the FNM is implemented in a planning process that quantifies the capacity of the fast responsive reserve (FRR). In two renewable penetration cases, the proposed FRR procurement successfully secured the frequency nadir above the security criterion.
- Open Access
- 1 April 2021
- Published by Institution of Engineering and Technology (IET) in IET Circuits, Devices & Systems
- Vol. 15 (7) , 657-669
Phase sequence interchange scheme for suppressing transient cross regulation on the compensator controlled and non‐compensator controlled single‐inductor dual‐output buck converter
Single input multiple output (SIMO) buck converter is a good solution to enhance the area efficiency of the power management unit. Because the SIMO type buck converter uses only one inductor to buffer the transferred energy for the multiple output ports, it usually suffers from severe transient cross regulation in a continuous conduction mode. Most of the well‐known approaches to suppress the transient cross regulation are either to create the additional free‐wheeling loop or to refine the controller loop. The control logic is usually quite specific which may not apply to the other controller types controller. A phase sequence interchange (PSI) scheme is proposed to mitigate the transient cross regulation without modifying the original control design. Compared to the other techniques, the proposed method can be easily applied, but not limited to the compensator‐based control or the non‐compensator‐based control in the buck converter. This study starts with the illustration of the reason why the PSI can mitigate the transient cross regulation. Detail designs are then presented to implement the proposed scheme on both the compensator type and the non‐compensator type controls. Experimental results show that the suppression of the cross regulation is comparable to the other state of the arts.
- 1 April 2021
- Published by Institution of Engineering and Technology (IET) in IET Circuits, Devices & Systems
- Vol. 15 (7) , 657-669
Open AccessPhase sequence interchange scheme for suppressing transient cross regulation on the compensator controlled and non‐compensator controlled single‐inductor dual‐output buck converter
Single input multiple output (SIMO) buck converter is a good solution to enhance the area efficiency of the power management unit. Because the SIMO type buck converter uses only one inductor to buffer the transferred energy for the multiple output ports, it usually suffers from severe transient cross regulation in a continuous conduction mode. Most of the well‐known approaches to suppress the transient cross regulation are either to create the additional free‐wheeling loop or to refine the controller loop. The control logic is usually quite specific which may not apply to the other controller types controller. A phase sequence interchange (PSI) scheme is proposed to mitigate the transient cross regulation without modifying the original control design. Compared to the other techniques, the proposed method can be easily applied, but not limited to the compensator‐based control or the non‐compensator‐based control in the buck converter. This study starts with the illustration of the reason why the PSI can mitigate the transient cross regulation. Detail designs are then presented to implement the proposed scheme on both the compensator type and the non‐compensator type controls. Experimental results show that the suppression of the cross regulation is comparable to the other state of the arts.
- Open Access
Construction of a Frequency Compliant Unit Commitment Framework Using an Ensemble Learning Technique
Frequency control is essential to ensure reliability and quality of power systems. North American Electric Reliability Corporation’s (NERC) Control Performance Standard 1 (CPS1) is widely adopted by many operating authorities to examine the quality of the frequency control. The operating authority would have a strong interest in knowing how the frequency-sensitive features affect the CPS1 score and finding out more effective unit-dispatch schedules for reaching the CPS1 goal. As frequency-sensitive features usually possess multi-variable and high-correlated characteristics, this paper employed an ensemble learning technique (the Gradient Boosting Decision Tree algorithm, GBDT) to construct Frequency Response Model (FRM) of the Taipower system in Taiwan to evaluate by CPS1 score. The proposed CPS1 model was then integrated with Unit Commitment (UC) program to determine the unit-dispatch that achieves the targeted CPS1 score. The feasibility and effectiveness of the proposed CPS1-UC platform were validated and compared with the other benchmark model-based UC methods by two operating cases. The proposed model shows promising results: the system frequency could be maintained well, especially in the periods of the early morning or the high renewable penetration.
Open AccessConstruction of a Frequency Compliant Unit Commitment Framework Using an Ensemble Learning Technique
Frequency control is essential to ensure reliability and quality of power systems. North American Electric Reliability Corporation’s (NERC) Control Performance Standard 1 (CPS1) is widely adopted by many operating authorities to examine the quality of the frequency control. The operating authority would have a strong interest in knowing how the frequency-sensitive features affect the CPS1 score and finding out more effective unit-dispatch schedules for reaching the CPS1 goal. As frequency-sensitive features usually possess multi-variable and high-correlated characteristics, this paper employed an ensemble learning technique (the Gradient Boosting Decision Tree algorithm, GBDT) to construct Frequency Response Model (FRM) of the Taipower system in Taiwan to evaluate by CPS1 score. The proposed CPS1 model was then integrated with Unit Commitment (UC) program to determine the unit-dispatch that achieves the targeted CPS1 score. The feasibility and effectiveness of the proposed CPS1-UC platform were validated and compared with the other benchmark model-based UC methods by two operating cases. The proposed model shows promising results: the system frequency could be maintained well, especially in the periods of the early morning or the high renewable penetration.
- 2 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (3) , 2437-2446
Area Efficient High-Performance Digitally Controlled Power Management Unit
Power management unit (PMU) is commonly used to manage power modules to achieve high efficient performance for integrated circuits. Inside the PMU, controllers that belong to different power modules could be pretty much similar. If the discrete feature of the digital control can be gainfully arranged, we can use only one controller to operate all the power modules inside the PMU, which can reduce circuit area and save cost. This paper proposes a pipeline concept to realize this idea. To achieve high performance, this paper also introduces a phase sequence interchange (PSI) technique to reduce the cross regulation problem of the SIDO converter and an auto-tuning charge balance algorithm (AT-CBA) to enhance the transient response. The PMU is fabricated in TSMC 0.18-μm CMOS manufacturing process for functional validation. Experimental results show that the pipeline controlled PMU can simultaneously output six voltages with extremely low cross regulation. The proposed AT-CBA also successfully make both Buck converter and LDO achieve near-optimal transient response in 40mV/5μs and 120mV/1μs, respectively.
- 2 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (3) , 2437-2446
Area Efficient High-Performance Digitally Controlled Power Management Unit
Power management unit (PMU) is commonly used to manage power modules to achieve high efficient performance for integrated circuits. Inside the PMU, controllers that belong to different power modules could be pretty much similar. If the discrete feature of the digital control can be gainfully arranged, we can use only one controller to operate all the power modules inside the PMU, which can reduce circuit area and save cost. This paper proposes a pipeline concept to realize this idea. To achieve high performance, this paper also introduces a phase sequence interchange (PSI) technique to reduce the cross regulation problem of the SIDO converter and an auto-tuning charge balance algorithm (AT-CBA) to enhance the transient response. The PMU is fabricated in TSMC 0.18-μm CMOS manufacturing process for functional validation. Experimental results show that the pipeline controlled PMU can simultaneously output six voltages with extremely low cross regulation. The proposed AT-CBA also successfully make both Buck converter and LDO achieve near-optimal transient response in 40mV/5μs and 120mV/1μs, respectively.
- 17 February 2020
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 48 (6) , 965-979
Auto‐tuning charge balance control for improving transient response on buck converter
- 17 February 2020
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 48 (6) , 965-979
Auto‐tuning charge balance control for improving transient response on buck converter