Andrew M.. Rollins
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrew M.. Rollins has a total of 227 co-authors. Here are the top co-authors by number of shared publications:
Michael W. Jenkins
Case Western Reserve University
20 shared publicationsMichiko Watanabe
Case Western Reserve University
15 shared publicationsShi Gu
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, UNITED STATES
13 shared publications- Michael W. Jenkins
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44106
12 shared publications Joseph A. Izatt
Duke Univ. (USA)
10 shared publicationsZhilin Hu
Case Western Reserve Department of Biomedical Engineering
10 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (04) , 1-11
Multimodal PSOCT-NIRS catheter for guided ablation of atrial fibrillation
SignificanceAtrial fibrillation is treated with thermal ablation to isolate ectopic signals. Although this is the current standard of care, recurrence occurs in up to 40% of cases. Clinicians have no reliable way to predict treatment durability intraoperatively. Adding the capability of direct optical measurement of the tissue to an ablation catheter could help better guide the treatment.AimA radiofrequency ablation catheter was developed with polarization-sensitive optical coherence tomography (PSOCT) and near-infrared spectroscopy (NIRS) to demonstrate, for the first time, simultaneous monitoring of thermal lesion formation.ApproachWe fabricated the multimodal PSOCT-NIRS ablation catheter and validated optical metrics using known targets of tissue-like phantom, deoxygenated blood, and atrial tissue. We then demonstrated recording PSOCT and NIRS data during ex vivo ablation of swine atria.ResultsPSOCT-NIRS metrics showed expected values in known targets. Measurements during ablation also exhibited previously reported patterns—OCT scattering increases, PSOCT birefringence decreases, and NIRS lesion optical index increases. Furthermore, simultaneous measurement revealed varying rates of change and magnitudes of response to different powers of thermal ablation.ConclusionsPSOCT-NIRS can measure tissue response to thermal energy delivery, and the optical metrics are complementary. By collecting more information during thermal energy delivery, PSOCT-NIRS metrics could contribute to understanding treatment durability in future investigations.
- 1 April 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (04) , 1-11
Open AccessMultimodal PSOCT-NIRS catheter for guided ablation of atrial fibrillation
SignificanceAtrial fibrillation is treated with thermal ablation to isolate ectopic signals. Although this is the current standard of care, recurrence occurs in up to 40% of cases. Clinicians have no reliable way to predict treatment durability intraoperatively. Adding the capability of direct optical measurement of the tissue to an ablation catheter could help better guide the treatment.AimA radiofrequency ablation catheter was developed with polarization-sensitive optical coherence tomography (PSOCT) and near-infrared spectroscopy (NIRS) to demonstrate, for the first time, simultaneous monitoring of thermal lesion formation.ApproachWe fabricated the multimodal PSOCT-NIRS ablation catheter and validated optical metrics using known targets of tissue-like phantom, deoxygenated blood, and atrial tissue. We then demonstrated recording PSOCT and NIRS data during ex vivo ablation of swine atria.ResultsPSOCT-NIRS metrics showed expected values in known targets. Measurements during ablation also exhibited previously reported patterns—OCT scattering increases, PSOCT birefringence decreases, and NIRS lesion optical index increases. Furthermore, simultaneous measurement revealed varying rates of change and magnitudes of response to different powers of thermal ablation.ConclusionsPSOCT-NIRS can measure tissue response to thermal energy delivery, and the optical metrics are complementary. By collecting more information during thermal energy delivery, PSOCT-NIRS metrics could contribute to understanding treatment durability in future investigations.
- Open Access
- 1 February 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (02) , 028001-13
Robust, high-density lesion mapping in the left atrium with near-infrared spectroscopy
Atrial fibrillation (AF) is a common cardiac arrhythmia associated with significant morbidity, mortality, and financial burden to the American healthcare system.1 Catheter-based radiofrequency ablation (RFA) is a minimally invasive AF treatment, in which radiofrequency electrical energy is used to electrically isolate presumed arrhythmogenic tissue.2 The aberrant electrical activity initiating AF has been shown to originate near the pulmonary veins (PVs) in a majority of patients, leading to widespread use of the procedure termed pulmonary vein isolation (PVI).2,3 However, arrhythmogenic tissue can exist beyond the PVs, limiting the effectiveness of PVI procedures.4 – 6 Also the success of RFA treatment is directly related to the depth and quality of RF energy delivery. Incomplete thermal treatment may permit subsequent conduction recovery, and many AF patients require a repeat procedure within 1 year of treatment.5 Conversely, tissue overtreatment can have serious complications, including cardiac perforation and embolic strokes.7 Hence, accurate characterization of ablated and unablated cardiac tissue is essential for the generation of safe, effective RF lesions that provide long-term freedom from atrial arrhythmias.
- 1 February 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (02) , 028001-13
Open AccessRobust, high-density lesion mapping in the left atrium with near-infrared spectroscopy
Atrial fibrillation (AF) is a common cardiac arrhythmia associated with significant morbidity, mortality, and financial burden to the American healthcare system.1 Catheter-based radiofrequency ablation (RFA) is a minimally invasive AF treatment, in which radiofrequency electrical energy is used to electrically isolate presumed arrhythmogenic tissue.2 The aberrant electrical activity initiating AF has been shown to originate near the pulmonary veins (PVs) in a majority of patients, leading to widespread use of the procedure termed pulmonary vein isolation (PVI).2,3 However, arrhythmogenic tissue can exist beyond the PVs, limiting the effectiveness of PVI procedures.4 – 6 Also the success of RFA treatment is directly related to the depth and quality of RF energy delivery. Incomplete thermal treatment may permit subsequent conduction recovery, and many AF patients require a repeat procedure within 1 year of treatment.5 Conversely, tissue overtreatment can have serious complications, including cardiac perforation and embolic strokes.7 Hence, accurate characterization of ablated and unablated cardiac tissue is essential for the generation of safe, effective RF lesions that provide long-term freedom from atrial arrhythmias.
- Open Access
- 3 October 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (06) , 061107-13
Image harmonization and deep learning automated classification of plus disease in retinopathy of prematurity
Retinopathy of prematurity (ROP), a disease affecting preterm infants characterized by abnormal development of retinal blood vessels, is the leading preventable cause of infantile blindness.1,2 Plus disease is an indicator of ROP severity and is characterized by severe dilation and tortuosity of retinal blood vessels in the posterior pole.1,3,4 Once plus disease is identified, infants are treated using laser photocoagulation or anti-vascular endothelial growth factor (anti-VEGF) injections with great success.5,6 However, an incorrect diagnosis or lack of screening can prove detrimental as the onset of plus disease can result in blindness within two weeks if left untreated, with nearly 50,000 infants blinded due to ROP annually worldwide.7,8 Routine retinal examination by skilled ophthalmologists is critical for early detection and treatment of ROP.
- 3 October 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 10 (06) , 061107-13
Open AccessImage harmonization and deep learning automated classification of plus disease in retinopathy of prematurity
Retinopathy of prematurity (ROP), a disease affecting preterm infants characterized by abnormal development of retinal blood vessels, is the leading preventable cause of infantile blindness.1,2 Plus disease is an indicator of ROP severity and is characterized by severe dilation and tortuosity of retinal blood vessels in the posterior pole.1,3,4 Once plus disease is identified, infants are treated using laser photocoagulation or anti-vascular endothelial growth factor (anti-VEGF) injections with great success.5,6 However, an incorrect diagnosis or lack of screening can prove detrimental as the onset of plus disease can result in blindness within two weeks if left untreated, with nearly 50,000 infants blinded due to ROP annually worldwide.7,8 Routine retinal examination by skilled ophthalmologists is critical for early detection and treatment of ROP.
- 6 April 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (5) , 1945-1958
Segmentation of beating embryonic heart structures from 4-D OCT images using deep learning
Optical coherence tomography (OCT) has been used to investigate heart development because of its capability to image both structure and function of beating embryonic hearts. Cardiac structure segmentation is a prerequisite for the quantification of embryonic heart motion and function using OCT. Since manual segmentation is time-consuming and labor-intensive, an automatic method is needed to facilitate high-throughput studies. The purpose of this study is to develop an image-processing pipeline to facilitate the segmentation of beating embryonic heart structures from a 4-D OCT dataset. Sequential OCT images were obtained at multiple planes of a beating quail embryonic heart and reassembled to a 4-D dataset using image-based retrospective gating. Multiple image volumes at different time points were selected as key-volumes, and their cardiac structures including myocardium, cardiac jelly, and lumen, were manually labeled. Registration-based data augmentation was used to synthesize additional labeled image volumes by learning transformations between key-volumes and other unlabeled volumes. The synthesized labeled images were then used to train a fully convolutional network (U-Net) for heart structure segmentation. The proposed deep learning-based pipeline achieved high segmentation accuracy with only two labeled image volumes and reduced the time cost of segmenting one 4-D OCT dataset from a week to two hours. Using this method, one could carry out cohort studies that quantify complex cardiac motion and function in developing hearts.
- 6 April 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (5) , 1945-1958
Segmentation of beating embryonic heart structures from 4-D OCT images using deep learning
Optical coherence tomography (OCT) has been used to investigate heart development because of its capability to image both structure and function of beating embryonic hearts. Cardiac structure segmentation is a prerequisite for the quantification of embryonic heart motion and function using OCT. Since manual segmentation is time-consuming and labor-intensive, an automatic method is needed to facilitate high-throughput studies. The purpose of this study is to develop an image-processing pipeline to facilitate the segmentation of beating embryonic heart structures from a 4-D OCT dataset. Sequential OCT images were obtained at multiple planes of a beating quail embryonic heart and reassembled to a 4-D dataset using image-based retrospective gating. Multiple image volumes at different time points were selected as key-volumes, and their cardiac structures including myocardium, cardiac jelly, and lumen, were manually labeled. Registration-based data augmentation was used to synthesize additional labeled image volumes by learning transformations between key-volumes and other unlabeled volumes. The synthesized labeled images were then used to train a fully convolutional network (U-Net) for heart structure segmentation. The proposed deep learning-based pipeline achieved high segmentation accuracy with only two labeled image volumes and reduced the time cost of segmenting one 4-D OCT dataset from a week to two hours. Using this method, one could carry out cohort studies that quantify complex cardiac motion and function in developing hearts.
- 14 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12355, 6-11
Polarization-Sensitive Optical Coherence Tomography (PSOCT) for identifying and analyzing gaps in lesion lines during ex vivo simulated radiofrequency ablation procedure
Atrial fibrillation (AF) is the most common arrhythmia worldwide. An increasingly common treatment option is catheter ablation. During this procedure, the electrophysiologist steers a catheter into the left atrium and ablates a lesion fence around common sources of ectopic signals. This blocks arrhythmogenic tissue from initiating an erroneous heartbeat. Technological advancements in this maturing procedure have made ablations more widespread and effective for patients, but there is still a need to improve long term efficacy of the procedure. The national rate of recurrent AF after an ablation is 20% to 40% and this is almost universally due to reconnection via poor lesion quality. With current catheter feedback available to clinicians, it is difficult to assess whether a lesion line will remain durable or heal to initiate recurrent AF. We have previously shown that polarization-sensitive optical coherence tomography (PSOCT) can monitor lesion formation in vivo during an ablation procedure. This feedback at the catheter tip may help clinicians assess lesion quality by measuring tissue changes. To further understand the technology’s utility and limitations, we are conducting experiments to characterize PSOCT detection of gaps between lesions. Lesion gaps are a common failure mode when AF recurrence is caused by reconnection. We ablate left atrial swine myocardium ex vivo and collect PSOCT images to compare with histology and identify the detection limits of small lesion gaps. Using PSOCT at the catheter tip to detect small gaps in lesion lines could help clinicians reduce recurrence by decreasing opportunities for reconnection.
- 14 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12355, 6-11
Polarization-Sensitive Optical Coherence Tomography (PSOCT) for identifying and analyzing gaps in lesion lines during ex vivo simulated radiofrequency ablation procedure
Atrial fibrillation (AF) is the most common arrhythmia worldwide. An increasingly common treatment option is catheter ablation. During this procedure, the electrophysiologist steers a catheter into the left atrium and ablates a lesion fence around common sources of ectopic signals. This blocks arrhythmogenic tissue from initiating an erroneous heartbeat. Technological advancements in this maturing procedure have made ablations more widespread and effective for patients, but there is still a need to improve long term efficacy of the procedure. The national rate of recurrent AF after an ablation is 20% to 40% and this is almost universally due to reconnection via poor lesion quality. With current catheter feedback available to clinicians, it is difficult to assess whether a lesion line will remain durable or heal to initiate recurrent AF. We have previously shown that polarization-sensitive optical coherence tomography (PSOCT) can monitor lesion formation in vivo during an ablation procedure. This feedback at the catheter tip may help clinicians assess lesion quality by measuring tissue changes. To further understand the technology’s utility and limitations, we are conducting experiments to characterize PSOCT detection of gaps between lesions. Lesion gaps are a common failure mode when AF recurrence is caused by reconnection. We ablate left atrial swine myocardium ex vivo and collect PSOCT images to compare with histology and identify the detection limits of small lesion gaps. Using PSOCT at the catheter tip to detect small gaps in lesion lines could help clinicians reduce recurrence by decreasing opportunities for reconnection.
- Open Access
- 1 March 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (3) , 25
Phase-Decorrelation Optical Coherence Tomography Measurement of Cold-Induced Nuclear Cataract
Purpose: The purpose of this work is to determine the sensitivity of phase-decorrelation optical coherence tomography (OCT) to protein aggregation associated with cataracts in the ocular lens, as compared to OCT signal intensity. Methods: Six fresh porcine globes were held at 4°C until cold cataracts developed. As the globes were re-warmed to ambient temperature, reversing the cold cataract, each lens was imaged repeatedly using a conventional OCT system. Throughout each experiment, the internal temperature of the globe was recorded using a needle-mounted thermocouple. OCT scans were acquired, their temporal fluctuations were analyzed, and the rates of decorrelation were spatially mapped. Both decorrelation and intensity were evaluated as a function of recorded temperature. Results: Both signal decorrelation and intensity were found to change with lens temperature, a surrogate of protein aggregation. However, the relationship between signal intensity and temperature was not consistent across different samples. In contrast, the relationship between decorrelation and temperature was found to be consistent across samples. Conclusions: In this study, signal decorrelation was shown to be a more repeatable metric for quantification of crystallin protein aggregation in the ocular lens than OCT intensity-based metrics. Thus, OCT signal decorrelation measurements could enable more detailed and sensitive study of methods to prevent cataract formation. Translational Relevance: This dynamic light scattering-based approach to early cataract assessment can be implemented on existing clinical OCT systems without hardware additions, so it could quickly become part of a clinical study workflow or an indication for use for a pharmaceutical cataract intervention.
- 1 March 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (3) , 25
Open AccessPhase-Decorrelation Optical Coherence Tomography Measurement of Cold-Induced Nuclear Cataract
Purpose: The purpose of this work is to determine the sensitivity of phase-decorrelation optical coherence tomography (OCT) to protein aggregation associated with cataracts in the ocular lens, as compared to OCT signal intensity. Methods: Six fresh porcine globes were held at 4°C until cold cataracts developed. As the globes were re-warmed to ambient temperature, reversing the cold cataract, each lens was imaged repeatedly using a conventional OCT system. Throughout each experiment, the internal temperature of the globe was recorded using a needle-mounted thermocouple. OCT scans were acquired, their temporal fluctuations were analyzed, and the rates of decorrelation were spatially mapped. Both decorrelation and intensity were evaluated as a function of recorded temperature. Results: Both signal decorrelation and intensity were found to change with lens temperature, a surrogate of protein aggregation. However, the relationship between signal intensity and temperature was not consistent across different samples. In contrast, the relationship between decorrelation and temperature was found to be consistent across samples. Conclusions: In this study, signal decorrelation was shown to be a more repeatable metric for quantification of crystallin protein aggregation in the ocular lens than OCT intensity-based metrics. Thus, OCT signal decorrelation measurements could enable more detailed and sensitive study of methods to prevent cataract formation. Translational Relevance: This dynamic light scattering-based approach to early cataract assessment can be implemented on existing clinical OCT systems without hardware additions, so it could quickly become part of a clinical study workflow or an indication for use for a pharmaceutical cataract intervention.
- Open Access
- 3 February 2023
- Published by Optica Publishing Group in Optica Open
Segmentation of beating embryonic heart structures from 4-D OCT images using deep learning
Optical coherence tomography (OCT) has been used to investigate heart development because of its capability to image both structure and function of beating embryonic hearts. Cardiac structure segmentation is a prerequisite for quantification of embryonic heart motion and function using OCT. Since manual segmentation is time-consuming and labor-intensive, an automatic method is needed to facilitate high-throughput studies. The purpose of this study is to develop an image processing pipeline to facilitate the segmentation of beating embryonic heart structures from a 4-D OCT dataset. Sequential OCT images were obtained at multiple planes of a beating quail embryonic heart and reassembled to a 4-D dataset using image-based retrospective gating. Multiple image volumes at different time points were selected as key-volumes and their cardiac structures including myocardium, cardiac jelly, and lumen were manually labeled. Registration-based data augmentation was used to synthesize additional labeled image volumes by learning transformations between key-volumes and other unlabeled volumes. The synthesized labeled images were then used to train a fully convolutional network (U-Net) for heart structure segmentation. The proposed deep learning-based pipeline achieved high segmentation accuracy with only two labeled image volumes and reduced the time cost of segmenting one 4-D OCT dataset from a week to two hours. Using this method, one could carry out cohort studies that quantify complex cardiac motion and function in developing hearts.
- 3 February 2023
- Published by Optica Publishing Group in Optica Open
Open AccessSegmentation of beating embryonic heart structures from 4-D OCT images using deep learning
Optical coherence tomography (OCT) has been used to investigate heart development because of its capability to image both structure and function of beating embryonic hearts. Cardiac structure segmentation is a prerequisite for quantification of embryonic heart motion and function using OCT. Since manual segmentation is time-consuming and labor-intensive, an automatic method is needed to facilitate high-throughput studies. The purpose of this study is to develop an image processing pipeline to facilitate the segmentation of beating embryonic heart structures from a 4-D OCT dataset. Sequential OCT images were obtained at multiple planes of a beating quail embryonic heart and reassembled to a 4-D dataset using image-based retrospective gating. Multiple image volumes at different time points were selected as key-volumes and their cardiac structures including myocardium, cardiac jelly, and lumen were manually labeled. Registration-based data augmentation was used to synthesize additional labeled image volumes by learning transformations between key-volumes and other unlabeled volumes. The synthesized labeled images were then used to train a fully convolutional network (U-Net) for heart structure segmentation. The proposed deep learning-based pipeline achieved high segmentation accuracy with only two labeled image volumes and reduced the time cost of segmenting one 4-D OCT dataset from a week to two hours. Using this method, one could carry out cohort studies that quantify complex cardiac motion and function in developing hearts.
- Open Access
- 3 February 2023
- Published by Optica Publishing Group in Optica Open
Segmentation of beating embryonic heart structures from 4-D OCT images using deep learning
Optical coherence tomography (OCT) has been used to investigate heart development because of its capability to image both structure and function of beating embryonic hearts. Cardiac structure segmentation is a prerequisite for quantification of embryonic heart motion and function using OCT. Since manual segmentation is time-consuming and labor-intensive, an automatic method is needed to facilitate high-throughput studies. The purpose of this study is to develop an image processing pipeline to facilitate the segmentation of beating embryonic heart structures from a 4-D OCT dataset. Sequential OCT images were obtained at multiple planes of a beating quail embryonic heart and reassembled to a 4-D dataset using image-based retrospective gating. Multiple image volumes at different time points were selected as key-volumes and their cardiac structures including myocardium, cardiac jelly, and lumen were manually labeled. Registration-based data augmentation was used to synthesize additional labeled image volumes by learning transformations between key-volumes and other unlabeled volumes. The synthesized labeled images were then used to train a fully convolutional network (U-Net) for heart structure segmentation. The proposed deep learning-based pipeline achieved high segmentation accuracy with only two labeled image volumes and reduced the time cost of segmenting one 4-D OCT dataset from a week to two hours. Using this method, one could carry out cohort studies that quantify complex cardiac motion and function in developing hearts.
- 3 February 2023
- Published by Optica Publishing Group in Optica Open
Open AccessSegmentation of beating embryonic heart structures from 4-D OCT images using deep learning
Optical coherence tomography (OCT) has been used to investigate heart development because of its capability to image both structure and function of beating embryonic hearts. Cardiac structure segmentation is a prerequisite for quantification of embryonic heart motion and function using OCT. Since manual segmentation is time-consuming and labor-intensive, an automatic method is needed to facilitate high-throughput studies. The purpose of this study is to develop an image processing pipeline to facilitate the segmentation of beating embryonic heart structures from a 4-D OCT dataset. Sequential OCT images were obtained at multiple planes of a beating quail embryonic heart and reassembled to a 4-D dataset using image-based retrospective gating. Multiple image volumes at different time points were selected as key-volumes and their cardiac structures including myocardium, cardiac jelly, and lumen were manually labeled. Registration-based data augmentation was used to synthesize additional labeled image volumes by learning transformations between key-volumes and other unlabeled volumes. The synthesized labeled images were then used to train a fully convolutional network (U-Net) for heart structure segmentation. The proposed deep learning-based pipeline achieved high segmentation accuracy with only two labeled image volumes and reduced the time cost of segmenting one 4-D OCT dataset from a week to two hours. Using this method, one could carry out cohort studies that quantify complex cardiac motion and function in developing hearts.
- 1 January 2022
- Published by Optica Publishing Group
- p. CW1E.6
Estimation of Corneal Crosslink Formation using Phase Decorrelation-Optical Coherence Tomography
Phase-decorrelation optical coherence tomography is sensitive to induced crosslinks in corneal tissue. This work compares PhD-OCT measurements from systematically varied crosslinking procedures to the magnitude of the crosslinking effect.
- 1 January 2022
- Published by Optica Publishing Group
- p. CW1E.6
Estimation of Corneal Crosslink Formation using Phase Decorrelation-Optical Coherence Tomography
Phase-decorrelation optical coherence tomography is sensitive to induced crosslinks in corneal tissue. This work compares PhD-OCT measurements from systematically varied crosslinking procedures to the magnitude of the crosslinking effect.
- 18 June 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 321 (2) , H294-H305
Prenatal ethanol exposure impairs the conduction delay at the atrioventricular junction in the looping heart
To the best of our knowledge, this is the first study investigating the impact of ethanol exposure on the early cardiac conduction system. Our results showed that ethanol-exposed embryos exhibited abnormally fast atrioventricular conduction. In addition, our findings, in CV measurements and endocardial cushion thickness, reveal regional differences in the AVJ myocardium even at this early stage in heart development, suggesting that the differentiation and maturation at this site are complex and warrant further studies.
- 18 June 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 321 (2) , H294-H305
Prenatal ethanol exposure impairs the conduction delay at the atrioventricular junction in the looping heart
To the best of our knowledge, this is the first study investigating the impact of ethanol exposure on the early cardiac conduction system. Our results showed that ethanol-exposed embryos exhibited abnormally fast atrioventricular conduction. In addition, our findings, in CV measurements and endocardial cushion thickness, reveal regional differences in the AVJ myocardium even at this early stage in heart development, suggesting that the differentiation and maturation at this site are complex and warrant further studies.