Stuart Werner Baur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stuart Werner Baur has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Katie Grantham
Missouri University of Science and Technology
3 shared publications Joel A. Lamson
Graduate student, Dept. of Aerospace and Mechanical Engineering, Missouri University of Science and Technology, 1870 Miner Circle, Rolla, MO 65409
2 shared publications- Matthew Nieters
Missouri University of Science and Technology
2 shared publications Nicole C. Annis
ENVIRON
2 shared publications- Semih Göksel Yıldırım
Istanbul Gelisim University
2 shared publications - Thomas G. Yarbrough
Missouri University of Science and Technology
2 shared publications
Latest Publications
- Open Access
- 1 January 2023
- Published by Istanbul Gelisim University in International Journal of Engineering Technologies IJET
- Vol. 8 (3) , 123-130
Experiential Learning in Daylighting Course through Performance Measurements
The main objective of this study is to adapt research studies on performance measurements for daylighting design to education. An experimental course has been introduced in Missouri University of Science and Technology, and the curriculum was developed by including active learning beside the traditional learning environment. The parameters used in the schematic design and design development stages are presented, and the curriculum topics and practical experience are explained in the study. Particularly performance measurements are associated with course assignments. Curriculum results are evaluated qualitatively with assignment results and quantitatively with surveys. Current and emerging metrics are included in lab assignments and results of course assessments show that emerging metrics in daylighting technology and practical experience had attraction over participants. As a result of the evaluation of two sample courses, differences emerge regarding the courses that can be given at undergraduate and graduate levels. These differences are grouped into traditional lecture learning environments and experiential learning environments. The learning outcomes of the course curricula are summarized as gaining the knowledge and skills to communicate technically at the level of design practitioner for the student aiming for undergraduate graduation and at the level of the research community for the student aiming for graduate level.
- 1 January 2023
- Published by Istanbul Gelisim University in International Journal of Engineering Technologies IJET
- Vol. 8 (3) , 123-130
Open AccessExperiential Learning in Daylighting Course through Performance Measurements
The main objective of this study is to adapt research studies on performance measurements for daylighting design to education. An experimental course has been introduced in Missouri University of Science and Technology, and the curriculum was developed by including active learning beside the traditional learning environment. The parameters used in the schematic design and design development stages are presented, and the curriculum topics and practical experience are explained in the study. Particularly performance measurements are associated with course assignments. Curriculum results are evaluated qualitatively with assignment results and quantitatively with surveys. Current and emerging metrics are included in lab assignments and results of course assessments show that emerging metrics in daylighting technology and practical experience had attraction over participants. As a result of the evaluation of two sample courses, differences emerge regarding the courses that can be given at undergraduate and graduate levels. These differences are grouped into traditional lecture learning environments and experiential learning environments. The learning outcomes of the course curricula are summarized as gaining the knowledge and skills to communicate technically at the level of design practitioner for the student aiming for undergraduate graduation and at the level of the research community for the student aiming for graduate level.
- Open Access
- 1 January 2023
- Published by Istanbul Gelisim University in International Journal of Engineering Technologies IJET
- Vol. 8 (2) , 77-82
Proposed Framework for Daylight-Focused Homes during Design Development
Solar decathlon is held biannually, and participant universities have a unique chance to locate solar houses on campus as a living lab after the contest. A variety of performance criteria are evaluated during the contest and daylighting is one among them. Complicated analysis tools, design solutions, and their effectiveness are major challenges during the design development of new solar houses. This challenge definition leads to developing a daylighting guideline for new solar house design. To provide a roadmap of validity of emerging daylighting metrics, demonstration of the daylighting performance of built-up solar houses, and daylighting guideline for design parameters with recent technology on new solar house design are the specific objectives of this study. The manuscript aims to examine the existing daylighting design tools while proposing a roadmap for how to use emerging metrics over solar house design. Three solar decathlon entries of Missouri University of Science and Technology are selected for post-occupancy evaluation to verify selected design tools. After analyze method, tools and final products are introduced which can be used on case studies, impact on research and education is discussed in the paper. Experiential method proposal for daylighting design have three phases and these are; the daylight metrics, the daylight performance and impact on research and education. It would be beneficial in the future to have this as a design guide, especially for any residential buildings rather than just solar houses.
- 1 January 2023
- Published by Istanbul Gelisim University in International Journal of Engineering Technologies IJET
- Vol. 8 (2) , 77-82
Open AccessProposed Framework for Daylight-Focused Homes during Design Development
Solar decathlon is held biannually, and participant universities have a unique chance to locate solar houses on campus as a living lab after the contest. A variety of performance criteria are evaluated during the contest and daylighting is one among them. Complicated analysis tools, design solutions, and their effectiveness are major challenges during the design development of new solar houses. This challenge definition leads to developing a daylighting guideline for new solar house design. To provide a roadmap of validity of emerging daylighting metrics, demonstration of the daylighting performance of built-up solar houses, and daylighting guideline for design parameters with recent technology on new solar house design are the specific objectives of this study. The manuscript aims to examine the existing daylighting design tools while proposing a roadmap for how to use emerging metrics over solar house design. Three solar decathlon entries of Missouri University of Science and Technology are selected for post-occupancy evaluation to verify selected design tools. After analyze method, tools and final products are introduced which can be used on case studies, impact on research and education is discussed in the paper. Experiential method proposal for daylighting design have three phases and these are; the daylight metrics, the daylight performance and impact on research and education. It would be beneficial in the future to have this as a design guide, especially for any residential buildings rather than just solar houses.
- 17 February 2015
- Published by American Society of Civil Engineers (ASCE)
- p. 279-288
Analysis of a Fixed Passive Louver Shading Device
This research has implemented simulation modeling software, Energy Plus, to predict the effect of passive louver shades across a standard year on a home within the Midwest. This energy model of the building has been validated against actual experimental data, over the course of six months. This research optimized a passive louver shading array, unique to this latitude, by generating converging simulations to track energy demands of the heating and cooling systems of the home. The optimized array characteristics are derived from the minimization of the overall energy performance of these systems. Based on a proposed louver configuration a reduction of 17% in overall energy consumption was predicted when compared to a similar house model without a louver array. A Louver Configuration Input Program was developed to allow a user to input continuous values within the range of variable and be output an estimate of energy loading.
- 17 February 2015
- Published by American Society of Civil Engineers (ASCE)
- p. 279-288
Analysis of a Fixed Passive Louver Shading Device
This research has implemented simulation modeling software, Energy Plus, to predict the effect of passive louver shades across a standard year on a home within the Midwest. This energy model of the building has been validated against actual experimental data, over the course of six months. This research optimized a passive louver shading array, unique to this latitude, by generating converging simulations to track energy demands of the heating and cooling systems of the home. The optimized array characteristics are derived from the minimization of the overall energy performance of these systems. Based on a proposed louver configuration a reduction of 17% in overall energy consumption was predicted when compared to a similar house model without a louver array. A Louver Configuration Input Program was developed to allow a user to input continuous values within the range of variable and be output an estimate of energy loading.
- 17 February 2015
- Published by American Society of Civil Engineers (ASCE)
- p. 501-513
Simulation of the 2013 Solar House for Missouri S&T
This paper presents the findings of two equivalent size homes (990 ft2) using Energy-10 (version 1.8) software. The home’s design was based on the solar house entry from Missouri S&T into the Department of Energy 2013 Solar Decathlon. The intent of the research was to determine the energy efficiency, consumption, and generation. The comparative home of similar size and layout was modelled using the IBC 2012 recommended insulated values and standard construction methods. As a baseline for occupant usage, a fictional American couple was created and a breakdown of their daily lifestyle was recorded to accurately depict the magnitude of energy consumption. Based on the comparative analysis and suggested energy conserving strategies, a 71% energy savings was forecasted using the Energy-10 software. In addition, if a 9.1 kW photovoltaic array is also installed on a home of this size, it is possible to fully offset the energy consumption of the home. The Missouri S&T Solar House Team used the forecasted energy usage and production to evaluate the integrity of their design for the Solar Decathlon in October 2013.
- 17 February 2015
- Published by American Society of Civil Engineers (ASCE)
- p. 501-513
Simulation of the 2013 Solar House for Missouri S&T
This paper presents the findings of two equivalent size homes (990 ft2) using Energy-10 (version 1.8) software. The home’s design was based on the solar house entry from Missouri S&T into the Department of Energy 2013 Solar Decathlon. The intent of the research was to determine the energy efficiency, consumption, and generation. The comparative home of similar size and layout was modelled using the IBC 2012 recommended insulated values and standard construction methods. As a baseline for occupant usage, a fictional American couple was created and a breakdown of their daily lifestyle was recorded to accurately depict the magnitude of energy consumption. Based on the comparative analysis and suggested energy conserving strategies, a 71% energy savings was forecasted using the Energy-10 software. In addition, if a 9.1 kW photovoltaic array is also installed on a home of this size, it is possible to fully offset the energy consumption of the home. The Missouri S&T Solar House Team used the forecasted energy usage and production to evaluate the integrity of their design for the Solar Decathlon in October 2013.
- 17 February 2015
- Published by American Society of Civil Engineers (ASCE)
- p. 289-299
Passive Heating and Lighting—A Case Study Using S&T 2009 Solar House
Solar louvers and light shelves serve as passive cooling, shading, and lighting mechanisms. The goal of this research was to optimize a passive system for this particular location and building shape/orientation by observing how the temperature and lighting change with different outdoor building attachments is the goal of this project. As part of this pilot study this research provides some of the methodology being used. The first method examines a physical scale model using the Sun Path Method. A second comparative method was used to compare the results further quantifying the results of the first method through computer simulation software known as Ecotect. Based on the methodologies used the simulations yielded a reduction in solar thermal gain of 10–15% during the summer months when solar shading devices were used yet had little to no impact on the daylighting effect.
- 17 February 2015
- Published by American Society of Civil Engineers (ASCE)
- p. 289-299
Passive Heating and Lighting—A Case Study Using S&T 2009 Solar House
Solar louvers and light shelves serve as passive cooling, shading, and lighting mechanisms. The goal of this research was to optimize a passive system for this particular location and building shape/orientation by observing how the temperature and lighting change with different outdoor building attachments is the goal of this project. As part of this pilot study this research provides some of the methodology being used. The first method examines a physical scale model using the Sun Path Method. A second comparative method was used to compare the results further quantifying the results of the first method through computer simulation software known as Ecotect. Based on the methodologies used the simulations yielded a reduction in solar thermal gain of 10–15% during the summer months when solar shading devices were used yet had little to no impact on the daylighting effect.
- Open Access
Energy Analysis of a Student-Designed Solar House
This paper presents the findings from an undergraduate research project concerning the energy efficiency, consumption, and generation of a 1000 ft2 (92.9 m2) solar house. The results were compared to a home of similar size and layout, built using traditional construction methods. The solar house was modeled after the Chameleon House: Missouri University of Science and Technology’s 2013 entry in the U.S. Department of Energy Solar Decathlon. The efficiency of the design was analyzed using Energy-10 Version 1.8 software. For this comparison, a fictional American couple was created and a breakdown of their energy-use habits was recorded to accurately depict the magnitude of energy consumption. A 71% energy savings was forecasted using the Energy-10 software through the incorporation of various energy-conserving strategies in the home’s design. In addition, if a 9.1 kW photovoltaic array is also installed on a home of this size, it is possible to fully offset the energy consumption of the home. The forecasted energy usage and production detailed in this report shall be used for analyzing the integrity of the design of the Chameleon House as well as future solar houses constructed by the Missouri S&T Solar House Team.
Open AccessEnergy Analysis of a Student-Designed Solar House
This paper presents the findings from an undergraduate research project concerning the energy efficiency, consumption, and generation of a 1000 ft2 (92.9 m2) solar house. The results were compared to a home of similar size and layout, built using traditional construction methods. The solar house was modeled after the Chameleon House: Missouri University of Science and Technology’s 2013 entry in the U.S. Department of Energy Solar Decathlon. The efficiency of the design was analyzed using Energy-10 Version 1.8 software. For this comparison, a fictional American couple was created and a breakdown of their energy-use habits was recorded to accurately depict the magnitude of energy consumption. A 71% energy savings was forecasted using the Energy-10 software through the incorporation of various energy-conserving strategies in the home’s design. In addition, if a 9.1 kW photovoltaic array is also installed on a home of this size, it is possible to fully offset the energy consumption of the home. The forecasted energy usage and production detailed in this report shall be used for analyzing the integrity of the design of the Chameleon House as well as future solar houses constructed by the Missouri S&T Solar House Team.
- 1 September 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Energy Engineering
- Vol. 138 (3) , 130-135
Thermal Energy Performance of a Solar Thermal Electric Panel
The main goal of this research was to develop and understand the performance of a hybrid roof system that combined an amorphous junction photovoltaic panel in combination with copper panel and tubing encased in a low-iron glass. The setup encompassed 160 sq ft of the solar thermal electric panel (STEP) system supplied with a glycol-water closed-loop system. The system was fixed to a simulated roof assembly built at the optimal angle of 61° for winter solstice for the local area (Rolla, Missouri). The encased combination panel provided consistent electrical efficiency and mixed thermal efficiencies based on the hours of operation. In conclusion this paper will discuss experimental performance analysis on the STEP system thermal and overall outcomes. Further testing on the effects of a glazed versus unglazed panel yielded a 23% reduction in solar electric production; however, it increased thermal collection by approximately 200%. The present study shows that the idea of a STEP system is viable. A pr...
- 1 September 2012
- Published by American Society of Civil Engineers (ASCE) in Journal of Energy Engineering
- Vol. 138 (3) , 130-135
Thermal Energy Performance of a Solar Thermal Electric Panel
The main goal of this research was to develop and understand the performance of a hybrid roof system that combined an amorphous junction photovoltaic panel in combination with copper panel and tubing encased in a low-iron glass. The setup encompassed 160 sq ft of the solar thermal electric panel (STEP) system supplied with a glycol-water closed-loop system. The system was fixed to a simulated roof assembly built at the optimal angle of 61° for winter solstice for the local area (Rolla, Missouri). The encased combination panel provided consistent electrical efficiency and mixed thermal efficiencies based on the hours of operation. In conclusion this paper will discuss experimental performance analysis on the STEP system thermal and overall outcomes. Further testing on the effects of a glazed versus unglazed panel yielded a 23% reduction in solar electric production; however, it increased thermal collection by approximately 200%. The present study shows that the idea of a STEP system is viable. A pr...
- 1 April 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance Comparison of Modular Photovoltaic-Thermal Solar Panels
The purpose of this experiment was to create a modular photovoltaic-thermal panel, which would be easily implemented and maintained. Three different prototype panels were tested simultaneously. The system was fixed at the optimal angle of 37.95° for the local area (Rolla, Missouri).The first two panels (Panel A & B) consisted of a highly conductive thermal sheeting and different sized copper tubing. The third panel (Panel C) consisted of copper tubing with an aluminum fin. Thermal images were used to verify the heat transfer across the panels and compare with the standard photovoltaic panel. The thermal efficiencies of panels A, B and C at 0.5 gallon per minute were 33.6%, 26.4% and 28.7%, respectively. Based on the thermal efficiency of Panel A three similar PVT panels were connected in series. Panels A1-3 at 0.5, 1.0 and 1.5 gpm had thermal gain plus electrical output equivalents of 931.9, 1281.2 and 1496.8 watts.
- 1 April 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Performance Comparison of Modular Photovoltaic-Thermal Solar Panels
The purpose of this experiment was to create a modular photovoltaic-thermal panel, which would be easily implemented and maintained. Three different prototype panels were tested simultaneously. The system was fixed at the optimal angle of 37.95° for the local area (Rolla, Missouri).The first two panels (Panel A & B) consisted of a highly conductive thermal sheeting and different sized copper tubing. The third panel (Panel C) consisted of copper tubing with an aluminum fin. Thermal images were used to verify the heat transfer across the panels and compare with the standard photovoltaic panel. The thermal efficiencies of panels A, B and C at 0.5 gallon per minute were 33.6%, 26.4% and 28.7%, respectively. Based on the thermal efficiency of Panel A three similar PVT panels were connected in series. Panels A1-3 at 0.5, 1.0 and 1.5 gpm had thermal gain plus electrical output equivalents of 931.9, 1281.2 and 1496.8 watts.
- 1 January 2011
- Published by ASME International
- p. 1351-1358
Experimental and Modeling Comparison of Modular Photovoltaic-Thermal Solar Panels
The scope of the project included two steps. Step one was to create three prototype photovoltaic-thermal panels and test them. Step two was to model all photovoltaic-thermal panels using TRNSYS 16. The three different photovoltaic-thermal panels were tested simultaneously using the same inlet water source. The first two panels (Panel A & B) consisted of a highly conductive thermal sheeting and different sized copper tubing. The third panel (Panel C) consisted of copper tubing with an aluminum fin. Thermal images were used to verify the heat transfer across the panels and compare the amount of heat radiating off the back of the photovoltaic-thermal panels versus the standard photovoltaic panel. The purpose of this experiment was to create a modular photovoltaic-thermal panel, which would be easily implemented and maintained by the average consumer. A TRNSYS model was created for each photovoltaic-thermal panel to gather approximate year-round efficiency. The thermal efficiencies of photovoltaic-thermal panels A, B and C at 1.9 lpm (0.5 gpm) were 33.6%, 26.4% and 28.7%, respectively. Panels A, B and C at 1.9 lpm (0.5 gpm) had thermal gain plus electrical output equivalents of 394.0, 363.2 and 422.9 watts, respectively. The TRNSYS models of the prototype photovoltaic-thermal (Panels A, B and C) proved to be a poor representation of the actual texted panels.
- 1 January 2011
- Published by ASME International
- p. 1351-1358
Experimental and Modeling Comparison of Modular Photovoltaic-Thermal Solar Panels
The scope of the project included two steps. Step one was to create three prototype photovoltaic-thermal panels and test them. Step two was to model all photovoltaic-thermal panels using TRNSYS 16. The three different photovoltaic-thermal panels were tested simultaneously using the same inlet water source. The first two panels (Panel A & B) consisted of a highly conductive thermal sheeting and different sized copper tubing. The third panel (Panel C) consisted of copper tubing with an aluminum fin. Thermal images were used to verify the heat transfer across the panels and compare the amount of heat radiating off the back of the photovoltaic-thermal panels versus the standard photovoltaic panel. The purpose of this experiment was to create a modular photovoltaic-thermal panel, which would be easily implemented and maintained by the average consumer. A TRNSYS model was created for each photovoltaic-thermal panel to gather approximate year-round efficiency. The thermal efficiencies of photovoltaic-thermal panels A, B and C at 1.9 lpm (0.5 gpm) were 33.6%, 26.4% and 28.7%, respectively. Panels A, B and C at 1.9 lpm (0.5 gpm) had thermal gain plus electrical output equivalents of 394.0, 363.2 and 422.9 watts, respectively. The TRNSYS models of the prototype photovoltaic-thermal (Panels A, B and C) proved to be a poor representation of the actual texted panels.
- Open Access
Simulation Prototyping of an Experimental Solar House
This paper presents a comparative analysis between an energy simulation model and an actual solar home. The case study used was the Team Missouri’s 2009 Solar Decathlon entry. The home was evaluated using the predicted data developed with the use of Energy-10 Version 1.8. The software simulates the energy use performance of building strategies ranging from building envelope and system efficiency options. The performance data used was collected during the 2009 Solar Decathlon competition. Results comparing energy efficient strategies, consumption and generation are explored with future implications discussed.
Open AccessSimulation Prototyping of an Experimental Solar House
This paper presents a comparative analysis between an energy simulation model and an actual solar home. The case study used was the Team Missouri’s 2009 Solar Decathlon entry. The home was evaluated using the predicted data developed with the use of Energy-10 Version 1.8. The software simulates the energy use performance of building strategies ranging from building envelope and system efficiency options. The performance data used was collected during the 2009 Solar Decathlon competition. Results comparing energy efficient strategies, consumption and generation are explored with future implications discussed.