Dorothea Theilig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dorothea Theilig has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Dominik Geisel
Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Department of Diagnostic and Interventional Radiology, Berlin, Germany
5 shared publications- Aboelyazid Elkilany
Department of Diagnostic and Interventional Radiology, University Hospital Leipzig, Germany
4 shared publications Bernd Hamm
Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Department of Diagnostic and Interventional Radiology, Berlin, Germany
4 shared publicationsAnna Mayerhofer
Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Department of Diagnostic and Interventional Radiology, Berlin, Germany
3 shared publications- Bernd Hamm
European Radiology, European Society of Radiology, Vienna, Austria
3 shared publications Bernhard Gebauer
Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Department of Diagnostic and Interventional Radiology, Berlin, Germany
3 shared publications
Latest Publications
- Open Access
- 12 July 2021
- Published by Springer Nature in European Radiology
- Vol. 32 (1) , 743
Correction to: Impact of interventionalist’s experience and gender on radiation dose and procedural time in CT-guided interventions—a retrospective analysis of 4380 cases over 10 years
A Correction to this paper has been published: 10.1007/s00330-021-08138-8
- 12 July 2021
- Published by Springer Nature in European Radiology
- Vol. 32 (1) , 743
Open AccessCorrection to: Impact of interventionalist’s experience and gender on radiation dose and procedural time in CT-guided interventions—a retrospective analysis of 4380 cases over 10 years
A Correction to this paper has been published: 10.1007/s00330-021-08138-8
- Open Access
- 26 August 2020
- Published by Springer Nature in European Radiology
- Vol. 31 (2) , 569-579
Impact of interventionalist’s experience and gender on radiation dose and procedural time in CT-guided interventions—a retrospective analysis of 4380 cases over 10 years
Objectives: To investigate the impact of the interventionalist’s experience and gender on radiation dose and procedural time in CT-guided interventions. Methods: We retrospectively analyzed 4380 CT-guided interventions performed at our institution with the same CT scanner from 2009 until 2018, 1287 (29%) by female and 3093 (71%) by male interventionalists. Radiation dose, number of CT fluoroscopy images taken per intervention, total procedural time, type of intervention, and degree of difficulty were derived from the saved dose reports and images. All 16 interventionalists included in this analysis performed their first CT-guided interventions during the study period, and interventions performed by each interventionalist were counted to assess the level of experience for each intervention in terms of the number of prior interventions performed by her or him. The Mann-Whitney U test (MWU test), multivariate regression, and linear mixed model analysis were performed. Results: Assessment of the impact of gender with the MWU test revealed that female interventionalists took a significantly smaller number of images (p < 0.0001) and achieved a lower dose-length product per intervention (p < 0.0001) while taking more time per intervention (p = 0.0001). This finding was confirmed for most types of interventions when additionally accounting for other possible impact factors in multivariate regression analysis. In linear mixed model analysis, we found that radiation dose, number of images taken per intervention, and procedural time decreased statistically significantly with interventionalist’s experience. Conclusions: Radiation doses of CT-guided interventions are reduced by interventionalist’s experience and, for most types of interventions, when performed by female interventionalists. Key Points: • Radiation doses in CT-guided interventions are lower when performed by female interventionalists. • Procedural times of CT-guided interventions are longer when performed by female interventionalists. • Radiation doses of CT-guided interventions decrease with the interventionalist’s experience.
- 26 August 2020
- Published by Springer Nature in European Radiology
- Vol. 31 (2) , 569-579
Open AccessImpact of interventionalist’s experience and gender on radiation dose and procedural time in CT-guided interventions—a retrospective analysis of 4380 cases over 10 years
Objectives: To investigate the impact of the interventionalist’s experience and gender on radiation dose and procedural time in CT-guided interventions. Methods: We retrospectively analyzed 4380 CT-guided interventions performed at our institution with the same CT scanner from 2009 until 2018, 1287 (29%) by female and 3093 (71%) by male interventionalists. Radiation dose, number of CT fluoroscopy images taken per intervention, total procedural time, type of intervention, and degree of difficulty were derived from the saved dose reports and images. All 16 interventionalists included in this analysis performed their first CT-guided interventions during the study period, and interventions performed by each interventionalist were counted to assess the level of experience for each intervention in terms of the number of prior interventions performed by her or him. The Mann-Whitney U test (MWU test), multivariate regression, and linear mixed model analysis were performed. Results: Assessment of the impact of gender with the MWU test revealed that female interventionalists took a significantly smaller number of images (p < 0.0001) and achieved a lower dose-length product per intervention (p < 0.0001) while taking more time per intervention (p = 0.0001). This finding was confirmed for most types of interventions when additionally accounting for other possible impact factors in multivariate regression analysis. In linear mixed model analysis, we found that radiation dose, number of images taken per intervention, and procedural time decreased statistically significantly with interventionalist’s experience. Conclusions: Radiation doses of CT-guided interventions are reduced by interventionalist’s experience and, for most types of interventions, when performed by female interventionalists. Key Points: • Radiation doses in CT-guided interventions are lower when performed by female interventionalists. • Procedural times of CT-guided interventions are longer when performed by female interventionalists. • Radiation doses of CT-guided interventions decrease with the interventionalist’s experience.
- Open Access
- 3 July 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-10
Impact of quantitative pulmonary emphysema score on the rate of pneumothorax and chest tube insertion in CT-guided lung biopsies
The aim of this study was to evaluate the risk of pneumothorax and need for chest tube insertion in CT-guided lung biopsies and identify predictors focusing on pulmonary emphysema determined with quantitative computed tomography. To that end, we retrospectively analysed the incidence of pneumothorax and chest tube insertion in 371 CT-guided lung biopsies with respect to the quantitative emphysema score determined with the density mask technique. Other possible impact factors considered were lesion diameter, length of biopsy pathway within the lung parenchyma, lung lobe, needle size, puncture technique, patient positioning and interventionalist’s level of experience. Quantitative emphysema scores of the lung were significantly higher in patients who developed instant pneumothorax (27%, p < 0.0001), overall pneumothorax (38%, p = 0.001) and had chest tube insertion (9%, p = 0.006) compared to those who did not when analysed with the Mann–Whitney U-test. In logistic regression analysis with inclusion of the other possible impact factors, the quantitative emphysema score remained a statistically significant predictor for all three output parameters. This was confirmed with least absolute shrinkage and selection operator (Lasso) regression analysis. In conclusion, quantitatively determined pulmonary emphysema is a positive predictor of the pneumothorax rate in CT-guided lung biopsy and likelihood of chest tube insertion.
- 3 July 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-10
Open AccessImpact of quantitative pulmonary emphysema score on the rate of pneumothorax and chest tube insertion in CT-guided lung biopsies
The aim of this study was to evaluate the risk of pneumothorax and need for chest tube insertion in CT-guided lung biopsies and identify predictors focusing on pulmonary emphysema determined with quantitative computed tomography. To that end, we retrospectively analysed the incidence of pneumothorax and chest tube insertion in 371 CT-guided lung biopsies with respect to the quantitative emphysema score determined with the density mask technique. Other possible impact factors considered were lesion diameter, length of biopsy pathway within the lung parenchyma, lung lobe, needle size, puncture technique, patient positioning and interventionalist’s level of experience. Quantitative emphysema scores of the lung were significantly higher in patients who developed instant pneumothorax (27%, p < 0.0001), overall pneumothorax (38%, p = 0.001) and had chest tube insertion (9%, p = 0.006) compared to those who did not when analysed with the Mann–Whitney U-test. In logistic regression analysis with inclusion of the other possible impact factors, the quantitative emphysema score remained a statistically significant predictor for all three output parameters. This was confirmed with least absolute shrinkage and selection operator (Lasso) regression analysis. In conclusion, quantitatively determined pulmonary emphysema is a positive predictor of the pneumothorax rate in CT-guided lung biopsy and likelihood of chest tube insertion.
- 1 March 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 124, 108807
Evaluating hepatotoxic effects of chemotherapeutic agents with gadoxetic-acid-enhanced magnetic resonance imaging
- 1 March 2020
- Published by Elsevier in European Journal of Radiology
- Vol. 124, 108807
Evaluating hepatotoxic effects of chemotherapeutic agents with gadoxetic-acid-enhanced magnetic resonance imaging
- 27 February 2020
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 192 (06) , 561-566
The Renal Resistive Index in Allografts: Is Sonographic Assessment Sufficiently Reproducible in a Routine Clinical Setting? – Reproducibility of the Renal Resistive Index
Purpose To assess the reproducibility of the renal resistive index (RRI) in a routine clinical setting. Materials and Methods 22 patients with a kidney allograft and 19 physicians participated in our prospective study. Within 2 hours each patient was examined by 5 different physicians using 2 out of 3 different, randomly allocated ultrasound machines. Each investigator determined the hilar and parenchymal RRI of the allograft. The reproducibility and reproducibility limit of the RRI were assessed as well as Cronbach’s alpha and the intraclass correlation coefficient (ICC). The deviation of the RRI from the mean RRI over the 5 measurements was used as an indicator of reproducibility. The impact of the ultrasound machine, examiner’s level of experience, and kidney function impairment (GFR < 45 ml/min) was assessed with the Kruskal-Wallis test. The bivariate linear correlation of the minimal transplant distance from the body surface with the variance of the parenchymal RRI was analyzed. Results A reproducibility of 0.045 with a reproducibility limit of 0.124 was found for the parenchymal RRI. The ICC between RRIs was good with 0.852 for the parenchymal RRI and 0.868 for the hilar RRI. The type of ultrasound machine used was found to have a significant impact on the deviation of the parenchymal RRI (Kruskal-Wallis-Test, p = 0.003). Variance in serial parenchymal RRI measurements correlated significantly with the depth of the kidney transplant (p = 0.001). Conclusion While the RRI is generally sufficiently reproducible, the type of ultrasound machine used and the depth of the kidney transplant within the recipient’s body have a significant impact on reproducibility. Key Points: Citation Format
- 27 February 2020
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 192 (06) , 561-566
The Renal Resistive Index in Allografts: Is Sonographic Assessment Sufficiently Reproducible in a Routine Clinical Setting? – Reproducibility of the Renal Resistive Index
Purpose To assess the reproducibility of the renal resistive index (RRI) in a routine clinical setting. Materials and Methods 22 patients with a kidney allograft and 19 physicians participated in our prospective study. Within 2 hours each patient was examined by 5 different physicians using 2 out of 3 different, randomly allocated ultrasound machines. Each investigator determined the hilar and parenchymal RRI of the allograft. The reproducibility and reproducibility limit of the RRI were assessed as well as Cronbach’s alpha and the intraclass correlation coefficient (ICC). The deviation of the RRI from the mean RRI over the 5 measurements was used as an indicator of reproducibility. The impact of the ultrasound machine, examiner’s level of experience, and kidney function impairment (GFR < 45 ml/min) was assessed with the Kruskal-Wallis test. The bivariate linear correlation of the minimal transplant distance from the body surface with the variance of the parenchymal RRI was analyzed. Results A reproducibility of 0.045 with a reproducibility limit of 0.124 was found for the parenchymal RRI. The ICC between RRIs was good with 0.852 for the parenchymal RRI and 0.868 for the hilar RRI. The type of ultrasound machine used was found to have a significant impact on the deviation of the parenchymal RRI (Kruskal-Wallis-Test, p = 0.003). Variance in serial parenchymal RRI measurements correlated significantly with the depth of the kidney transplant (p = 0.001). Conclusion While the RRI is generally sufficiently reproducible, the type of ultrasound machine used and the depth of the kidney transplant within the recipient’s body have a significant impact on reproducibility. Key Points: Citation Format
- 19 July 2019
- Published by SAGE Publications in Acta Radiologica
- Vol. 61 (3) , 291-301
Gd-EOB-DTPA-enhanced MRI T1 relaxometry as an imaging-based liver function test compared with 13C-methacetin breath test
Background: Gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) can be used as an imaging-based liver function test. This study aims to further corroborate its validity. Purpose: To compare Gd-EOB-DTPA-enhanced MRI as an imaging-based liver function test with the 13C-methacetin breath test. Material and Methods: Fifty-three patients who underwent Gd-EOB-DTPA-enhanced MRI T1 relaxometry before and 20 min after intravenous Gd-EOB-DTPA administration as well as a 13C-methacetin breath test (LiMAx test) were retrospectively analyzed. T1 relaxation times of liver parenchyma, total liver volume (TLV), and functional liver volume (FLV) were determined. Pearson correlations, multiple linear regression analysis, and receiver operating characteristic curve analysis were performed with indices derived from T1 relaxometry, liver volumetry, and laboratory parameters to identify the best predictor of liver function as determined by the LiMAx test. Results: T1 reduction rate (T1 RR), T1 RR × TLV, T1 RR × FLV, and T1 relaxation time 20 min after intravenous Gd-EOB administration showed a statistically significant correlation with LiMAx and discriminatory capacity between patients with LiMAx of > and < 315 µg/kg/h. Of the indices investigated, T1 RR showed the best discriminatory capacity and proved to be the only statistically significant parameter in multiple linear regression analysis. Conclusion: Gd-EOB-DTPA-enhanced MRI as an imaging-based liver function test also correlates with the LiMAx test which in turn reflects cytochrome P450 function. The T1 reduction rate of the liver on Gd-EOB-DTPA-enhanced MRI allows prediction of liver function as determined by the LiMAx test both for 1.5 and 3.0 T.
- 19 July 2019
- Published by SAGE Publications in Acta Radiologica
- Vol. 61 (3) , 291-301
Gd-EOB-DTPA-enhanced MRI T1 relaxometry as an imaging-based liver function test compared with 13C-methacetin breath test
Background: Gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) can be used as an imaging-based liver function test. This study aims to further corroborate its validity. Purpose: To compare Gd-EOB-DTPA-enhanced MRI as an imaging-based liver function test with the 13C-methacetin breath test. Material and Methods: Fifty-three patients who underwent Gd-EOB-DTPA-enhanced MRI T1 relaxometry before and 20 min after intravenous Gd-EOB-DTPA administration as well as a 13C-methacetin breath test (LiMAx test) were retrospectively analyzed. T1 relaxation times of liver parenchyma, total liver volume (TLV), and functional liver volume (FLV) were determined. Pearson correlations, multiple linear regression analysis, and receiver operating characteristic curve analysis were performed with indices derived from T1 relaxometry, liver volumetry, and laboratory parameters to identify the best predictor of liver function as determined by the LiMAx test. Results: T1 reduction rate (T1 RR), T1 RR × TLV, T1 RR × FLV, and T1 relaxation time 20 min after intravenous Gd-EOB administration showed a statistically significant correlation with LiMAx and discriminatory capacity between patients with LiMAx of > and < 315 µg/kg/h. Of the indices investigated, T1 RR showed the best discriminatory capacity and proved to be the only statistically significant parameter in multiple linear regression analysis. Conclusion: Gd-EOB-DTPA-enhanced MRI as an imaging-based liver function test also correlates with the LiMAx test which in turn reflects cytochrome P450 function. The T1 reduction rate of the liver on Gd-EOB-DTPA-enhanced MRI allows prediction of liver function as determined by the LiMAx test both for 1.5 and 3.0 T.
- 25 April 2019
- Published by Springer Nature in Abdominal Radiology
- Vol. 44 (8) , 2759-2768
Consistency of hepatocellular gadoxetic acid uptake in serial MRI examinations for evaluation of liver function
To assess the consistency of liver enhancement in gadoxetic acid-enhanced magnetic resonance imaging (MRI) over serial examinations.
- 25 April 2019
- Published by Springer Nature in Abdominal Radiology
- Vol. 44 (8) , 2759-2768
Consistency of hepatocellular gadoxetic acid uptake in serial MRI examinations for evaluation of liver function
To assess the consistency of liver enhancement in gadoxetic acid-enhanced magnetic resonance imaging (MRI) over serial examinations.
- 21 March 2019
- Published by Springer Nature in European Radiology
- Vol. 29 (11) , 5861-5872
Predicting liver failure after extended right hepatectomy following right portal vein embolization with gadoxetic acid-enhanced MRI
Predicting post-hepatectomy liver failure (PHLF) after extended right hepatectomy following portal vein embolization (PVE) from serial gadoxetic acid-enhanced magnetic resonance imaging (MRI).
- 21 March 2019
- Published by Springer Nature in European Radiology
- Vol. 29 (11) , 5861-5872
Predicting liver failure after extended right hepatectomy following right portal vein embolization with gadoxetic acid-enhanced MRI
Predicting post-hepatectomy liver failure (PHLF) after extended right hepatectomy following portal vein embolization (PVE) from serial gadoxetic acid-enhanced magnetic resonance imaging (MRI).
- 11 October 2018
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 191 (01) , 40-47
Selecting Patients for Lobar Lung Volume Reduction Therapy: What Quantitative Computed Tomography Parameters Matter?
Purpose Evaluation of emphysema distribution with quantitative computed tomography (qCT) prior to endoscopic lung volume reduction (ELVR) is recommended. The aim of this study was to determine which of the commonly assessed qCT parameters prior to endoscopic lung volume reduction (ELVR) best predicts outcome of treatment. Materials and Methods 50 patients who underwent technically successful ELVR at our institution were retrospectively analyzed. We performed quantitative analysis of the CT scans obtained prior to ELVR and carried out Mann-Whitney U-tests and a logistic regression analysis to identify the qCT parameters that predict successful outcome of ELVR in terms of improved forced expiratory volume in 1 second (FEV1). Results In the Mann-Whitney U-test, the interlobar emphysema heterogeneity index (p = 0.008) and the pulmonary emphysema score (p = 0.022) showed a statistically significant difference between responders and non-responders. In multiple logistic regression analysis only the interlobar emphysema heterogeneity index (p = 0.008) showed a statistically significant impact on the outcome of ELVR, while targeted lobe volume, total lung volume, targeted lobe emphysema score and total lung emphysema score did not. Conclusion Of all commonly assessed quantitative CT parameters, only the heterogeneity index definitely allows prediction of ELVR outcome in patients with advanced chronic obstructive pulmonary disease (COPD). Key Points Citation Format Ziel Vor endoskopischer Lungenvolumenreduktion (ELVR) ist die Evaluation der Emphysemverteilung mittels quantitativer Computertomografie (qCT) empfohlen. Ziel dieser retrospektiven Studie war festzustellen, welche qCT-Parameter das postinterventionelle Outcome am besten vorhersagen. Material und Methoden Die präinterventionellen Computertomografien von fünfzig in unserer Institution technisch erfolgreich mit ELVR behandelten Patienten wurden quantitativ analysiert und mit prä- und postinterventionellen Lungenfunktionsuntersuchungen verglichen. Untersucht wurde die Relevanz der standardmäßig erhobenen qCT-Parameter, d. h. Gesamtlungenvolumen, Ziellappenvolumen, Emphysemindex der gesamten Lunge und des Ziellappens sowie Heterogenitätsindex. Mann-Whitney U-Test und logistische Regressionsanalyse wurden zur Identifikation derjenigen Parameter verwendet, die am besten einen Anstieg der FEV1 hervorsagten. Ergebnisse Im Mann-Whitney U-Test unterschieden sich lediglich interlobärer Emphysemheterogenitätsindex (p = 0,008) und pulmonaler Emphysemindex (p = 0,022) signifikant zwischen Therapieansprechern und Therapieversagern. Die logistische Regressionsanalyse zeigte lediglich für den Heterogenitätsindex signifikante Unterschiede zwischen beiden Patientengruppen (p = 0,008). Gesamtlungenvolumen, Ziellappenvolumen, sowie die Emphysemindices der gesamten Lunge und des Ziellappens wiesen dort keine signifikanten Unterschiede auf. Schlußfolgerungen Von allen bei der präinterventionellen qCT erhobenen Parametern scheint lediglich der interlobäre Heterogenitätsindex das klinische Outcome nach ELVR verlässlich vorauszusagen. Kernaussagen
- 11 October 2018
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 191 (01) , 40-47
Selecting Patients for Lobar Lung Volume Reduction Therapy: What Quantitative Computed Tomography Parameters Matter?
Purpose Evaluation of emphysema distribution with quantitative computed tomography (qCT) prior to endoscopic lung volume reduction (ELVR) is recommended. The aim of this study was to determine which of the commonly assessed qCT parameters prior to endoscopic lung volume reduction (ELVR) best predicts outcome of treatment. Materials and Methods 50 patients who underwent technically successful ELVR at our institution were retrospectively analyzed. We performed quantitative analysis of the CT scans obtained prior to ELVR and carried out Mann-Whitney U-tests and a logistic regression analysis to identify the qCT parameters that predict successful outcome of ELVR in terms of improved forced expiratory volume in 1 second (FEV1). Results In the Mann-Whitney U-test, the interlobar emphysema heterogeneity index (p = 0.008) and the pulmonary emphysema score (p = 0.022) showed a statistically significant difference between responders and non-responders. In multiple logistic regression analysis only the interlobar emphysema heterogeneity index (p = 0.008) showed a statistically significant impact on the outcome of ELVR, while targeted lobe volume, total lung volume, targeted lobe emphysema score and total lung emphysema score did not. Conclusion Of all commonly assessed quantitative CT parameters, only the heterogeneity index definitely allows prediction of ELVR outcome in patients with advanced chronic obstructive pulmonary disease (COPD). Key Points Citation Format Ziel Vor endoskopischer Lungenvolumenreduktion (ELVR) ist die Evaluation der Emphysemverteilung mittels quantitativer Computertomografie (qCT) empfohlen. Ziel dieser retrospektiven Studie war festzustellen, welche qCT-Parameter das postinterventionelle Outcome am besten vorhersagen. Material und Methoden Die präinterventionellen Computertomografien von fünfzig in unserer Institution technisch erfolgreich mit ELVR behandelten Patienten wurden quantitativ analysiert und mit prä- und postinterventionellen Lungenfunktionsuntersuchungen verglichen. Untersucht wurde die Relevanz der standardmäßig erhobenen qCT-Parameter, d. h. Gesamtlungenvolumen, Ziellappenvolumen, Emphysemindex der gesamten Lunge und des Ziellappens sowie Heterogenitätsindex. Mann-Whitney U-Test und logistische Regressionsanalyse wurden zur Identifikation derjenigen Parameter verwendet, die am besten einen Anstieg der FEV1 hervorsagten. Ergebnisse Im Mann-Whitney U-Test unterschieden sich lediglich interlobärer Emphysemheterogenitätsindex (p = 0,008) und pulmonaler Emphysemindex (p = 0,022) signifikant zwischen Therapieansprechern und Therapieversagern. Die logistische Regressionsanalyse zeigte lediglich für den Heterogenitätsindex signifikante Unterschiede zwischen beiden Patientengruppen (p = 0,008). Gesamtlungenvolumen, Ziellappenvolumen, sowie die Emphysemindices der gesamten Lunge und des Ziellappens wiesen dort keine signifikanten Unterschiede auf. Schlußfolgerungen Von allen bei der präinterventionellen qCT erhobenen Parametern scheint lediglich der interlobäre Heterogenitätsindex das klinische Outcome nach ELVR verlässlich vorauszusagen. Kernaussagen
- Open Access
- 1 June 2017
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 12, 1631-1640
Comparison of distinctive models for calculating an interlobar emphysema heterogeneity index in patients prior to endoscopic lung volume reduction
Background: The degree of interlobar emphysema heterogeneity is thought to play an important role in the outcome of endoscopic lung volume reduction (ELVR) therapy of patients with advanced COPD. There are multiple ways one could possibly define interlobar emphysema heterogeneity, and there is no standardized definition. Purpose: The aim of this study was to derive a formula for calculating an interlobar emphysema heterogeneity index (HI) when evaluating a patient for ELVR. Furthermore, an attempt was made to identify a threshold for relevant interlobar emphysema heterogeneity with regard to ELVR. Patients and methods: We retrospectively analyzed 50 patients who had undergone technically successful ELVR with placement of one-way valves at our institution and had received lung function tests and computed tomography scans before and after treatment. Predictive accuracy of the different methods for HI calculation was assessed with receiver-operating characteristic curve analysis, assuming a minimum difference in forced expiratory volume in 1 second of 100 mL to indicate a clinically important change. Results: The HI defined as emphysema score of the targeted lobe (TL) minus emphysema score of the ipsilateral nontargeted lobe disregarding the middle lobe yielded the best predicative accuracy (AUC =0.73, P=0.008). The HI defined as emphysema score of the TL minus emphysema score of the lung without the TL showed a similarly good predictive accuracy (AUC =0.72, P=0.009). Subgroup analysis suggests that the impact of interlobar emphysema heterogeneity is of greater importance in patients with upper lobe predominant emphysema than in patients with lower lobe predominant emphysema. Conclusion: This study reveals the most appropriate ways of calculating an interlobar emphysema heterogeneity with regard to ELVR.
- 1 June 2017
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 12, 1631-1640
Open AccessComparison of distinctive models for calculating an interlobar emphysema heterogeneity index in patients prior to endoscopic lung volume reduction
Background: The degree of interlobar emphysema heterogeneity is thought to play an important role in the outcome of endoscopic lung volume reduction (ELVR) therapy of patients with advanced COPD. There are multiple ways one could possibly define interlobar emphysema heterogeneity, and there is no standardized definition. Purpose: The aim of this study was to derive a formula for calculating an interlobar emphysema heterogeneity index (HI) when evaluating a patient for ELVR. Furthermore, an attempt was made to identify a threshold for relevant interlobar emphysema heterogeneity with regard to ELVR. Patients and methods: We retrospectively analyzed 50 patients who had undergone technically successful ELVR with placement of one-way valves at our institution and had received lung function tests and computed tomography scans before and after treatment. Predictive accuracy of the different methods for HI calculation was assessed with receiver-operating characteristic curve analysis, assuming a minimum difference in forced expiratory volume in 1 second of 100 mL to indicate a clinically important change. Results: The HI defined as emphysema score of the targeted lobe (TL) minus emphysema score of the ipsilateral nontargeted lobe disregarding the middle lobe yielded the best predicative accuracy (AUC =0.73, P=0.008). The HI defined as emphysema score of the TL minus emphysema score of the lung without the TL showed a similarly good predictive accuracy (AUC =0.72, P=0.009). Subgroup analysis suggests that the impact of interlobar emphysema heterogeneity is of greater importance in patients with upper lobe predominant emphysema than in patients with lower lobe predominant emphysema. Conclusion: This study reveals the most appropriate ways of calculating an interlobar emphysema heterogeneity with regard to ELVR.