JDJoost van Dinther

Joost van Dinther

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joost van Dinther has a total of 102 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • New Technique for Fixation of Cochlear Implant Electrodes Preventing Extrusion and Rotation of the Array

    by Glynnis De Greve, Manuel Manrique, Erwin Offeciers, Joost Van Dinther, Raquel Manrique, Andrzej Zarowski, Matthias Gramss

    BACKGROUND: Cochlear implants (CIs) have evolved to address diverse hearing impairments, expanding indications to include patients with residual hearing. Preserving residual hearing enables electro-acoustic stimulation, potentially improving CI outcomes. While “soft surgery” techniques are widely adopted to minimize immediate cochlear trauma, post-insertion electrode movements during the coiling of the electrode lead in the mastoid remain understudied. This study proposes novel surgical techniques of electrode fixation to minimize post-insertion movement. METHODS: A pilot study, in collaboration with Cochlear® (Mechelen, Belgium), examined the feasibility of stabilization grooves in the mastoid and removable stabilization material in the posterior tympanotomy during coiling. Objectives included minimizing axial rotation of the precurved perimodiolar 532/632 electrodes, improving electrode lead fixation, preventing intraoperative changes in the insertion depth, and assessing pediatric applicability. RESULTS: Combination of both proposed techniques allowed for stable electrode placement. The use of a removable sterile sponge in the posterior tympanotomy prevented axial rotation of the electrode beyond 90° and alterations in insertion depth, particularly during placement of the electrode in the attical groove and the subsequent coiling of the excess lead in the mastoid. The study also confirmed the feasibility of these techniques in pediatric models. CONCLUSION: The proposed techniques seem to be effective in securing electrode placement in the cochlea after insertion. These techniques involve only minor adaptations to the standard procedure, without the need for costly material or a substantially longer operating time. The authors therefore believe they have the potential for systematic implementation. Further research is required to validate these techniques and explore their impact on overall CI performance.

  • Open Access

    Tinnitus Suppression with Electrical Stimulation at the Most Basal Contact of the Cochlear Implant Electrode as a Model for Round Window Stimulation

    by Kiana Kheirkhah, Valerie Van Kelecom, Marc Leblans, Joost Van Dinther, Glynnis De Greve, Erwin Offeciers, Andrzej Zarowski

    Background: The objective of this research was to test whether efficient tinnitus suppression could be achieved by electrical stimulation of the single most basal electrode contact of a cochlear implant. This approach simulates the effects of electrical stimulation using a round-window electrode. Methods: The study was performed in 10 adult cochlear implant patients showing complete or almost complete tinnitus suppression during electrical stimulation with their standard fitting-MAP. In all patients, tinnitus appeared again when the implant was switched off. Five Nucleus implant (1 CI532, 4 CI24RE CA) users and 5 Mi12xx series with FLEX28 electrodes with at least 6 months of CI experience were included. Two types of stimulation were presented at the most basal CI contact: a constant pulse train and a modulated pulse train. The variation in pulse rates was low rate (100-300 pps) and high (≥900 pps), and the current level ranged from the C-level to less than the T-level for both stimulation types. The effect of acute electrical stimulation at the most basal electrode contact was compared to the effect obtained with multichannel stimulation with the patient’s current fitting MAP. Electrical stimulation was paused between tests with different stimulation types until tinnitus returned to baseline intensity. Patients reported Visual Analog Scale (VAS) scores for tinnitus loudness and intrusiveness during normal CI use and for each single contact stimulation type. Results: Eight participants perceived complete suppression with one or more stimulation patterns. In 2 patients, suppression was less efficient than full-band CI stimulation. Louder stimuli are generally perceived as annoying and less effective in reducing tinnitus. In FLEX28 patients, it was also possible to obtain full tinnitus suppression with current amplitudes under the thresholds for auditory perception (this was not tested in patients with the Nucleus device). Conclusion: In 8 of the 10 included patients, we were able to obtain complete or almost complete tinnitus suppression with electrical stimulation at only 1 most basal electrode contact. Therefore, round-window stimulation with a single electrode may be a potential treatment for tinnitus in patients with significant residual hearing. The long-term effects of this therapy should be confirmed in future studies. Cite this article as: Kheirkhah K, Van Kelecom V, Leblans M, et al. Tinnitus suppression with electrical stimulation at the most basal contact. J Int Adv Otol. 2024;20(5):390-396.


  • Open Access

    The Need for Vestibular Implants in a Tertiary Referral Ear, Nose, and Throat Center and Its Relation to Hearing Status

    by Morgana Sluydts, Julie Elen, Sandrien Mertens, Nadia Verstraeten, Kathleen Verhaegen, Erwin Offeciers, Joost Js van Dinther, Andrzej Zarowski, Floris L Wuyts

    BACKGROUND: Patients with bilateral vestibulopathy (BVP) are at increased risk of falling and have poor quality of life. Several research groups are currently developing and investigating vestibular implants to treat BVP. The goal was to identify how many patients can be considered eligible for vestibular implantation. METHODS: The objective vestibular implantation criteria for research were applied to the results of the caloric irrigation test, the sinusoidal harmonic acceleration test, the video head impulse test, and the cervical and ocular vestibular evoked myogenic potential tests. RESULTS: Vestibular implant eligibility was situated between 3.6% and 15.7% (semicircular canal implant: 3.6%; otolith implant: 15.7%; combined implant: 4.8%). Only 16 out of the 29 patients (55%) eligible for a vestibular implant had bilateral severe-to-profound hearing loss. The remaining 45% (13/29) thus have better hearing in at least 1 ear. CONCLUSION: Vestibular implant eligibility in an ear, nose, and throat department was situated between 3.6% and 15.7%, depending on the type of implant that was considered. In addition, the data showed that 45% of the eligible patients had normal-to-moderate hearing in at least 1 ear. In other words, only recruiting patients with (bilateral) severe-to-profound hearing loss for vestibular implantation leads to the systematic exclusion of about half of the candidates. Structure-preserving surgical techniques are thus a major future challenge in the field of vestibular implantation. Cite this article as: Sluydts M, Elen J, Mertens S, et al. The need for vestibular implants in a tertiary referral ear, nose, and throat center and its relation to hearing status. J Int Adv Otol. 2023;19(6):461-467.

  • Open Access

    Calculation of the Faradaic Impedance of the Electrode–Tissue Interface Improves Prediction of Behavioral T/C Levels in Cochlear Implant Patients

    by Andrzej Zarowski, Marc Leblans, Fergio Sismono, Joost van Dinther, F. Erwin Offeciers

    BACKGROUND: Fitting of cochlear implants is a labor-intensive process, and therefore automated fitting procedures are being sought. The objective of this study was to evaluate if decomposition of the complex impedance of the electrode–tissue interface could provide additional parameters that show improved correlation with the behavioral T/C levels. METHODS: A new method for decomposing the complex impedance of the electrode–tissue interface was developed and tested in 18 patients in a prospective study in a tertiary otologic referral center. RESULTS: The averaged near-field Faradaic resistance (RF) calculated in study subjects shows a very strong correlation (R2=0.80) with the behavioral C levels and can be used for automated fitting in most patients. The standard deviation for the T levels and the C levels calculated for each of the electrode contacts in all study subjects is in the range of 10-15 CL and 15-20 CL, respectively. These higher values of the standard deviations are caused by a few outliers who require that additional parameters have to be added to the metric equation, allowing for the automated prediction of the T/C levels. CONCLUSION: A new method for deriving information from the electrode impedance measurements shows excellent correlation of the Faradaic resistance with the behavioral T/C levels in most patients and can be very useful for fitting cochlear implants based on objective measures. Since some patients still show discrepancies between the predicted T/C levels based on the RF calculation, additional parameters have to be added to the metric equation, allowing for automated prediction of the T/C levels. Cite this article as: Zarowski A, Leblans M, Molisz A, Sismono F, van Dinther J, Offeciers FE. Calculation of the faradaic impedance of the electrode– tissue interface improves prediction of behavioral T/C levels in cochlear implant patients. J Int Adv Otol. 2023;19(5):368-375.


  • Open Access

    Vestibular Co-stimulation in Adults with a Cochlear Implant

    by Morgana Sluydts, Marc Leblans, Joost Js Van Dinther, Erwin Offeciers, Robby Vanspauwen, Floris L Wuyts, Andrzej Zarowski

    BACKGROUND: Vestibular co-stimulation is a side effect of cochlear implant stimulation. The electrical currents delivered by the cochlear implant can spread toward the vestibular system and thus stimulate it. The aim of the study is to evaluate whether it is feasible to functionally restore the balance by modifying the vestibular co-stimulation. METHODS: Four adult patients, who had received a commercially available cochlear implant previously, were enrolled. Counterbalanced biphasic pulses were presented as bursts or as an amplitude-modulated biphasic pulse train (modulation frequencies ranging from 1 to 500 Hz) at the participant’s upper comfortable level for electrical stimulation. Subjective sensations and vestibular-mediated eye movements were used for evaluating the possible effects of vestibular co-stimulation. RESULTS: One participant experienced a cyclic tilting of his head in response to an amplitude-modulated biphasic pulse train with a modulation frequency of 2 and 400 Hz. However, during a follow-up visit, the sensation could not be replicated. CONCLUSION: Subjective vestibular sensations or vestibular-mediated eye movements could not be electrically evoked with a commercially available cochlear implant in 4 adult patients with almost normal vestibular function. Therefore, customized design of the hard-, firm-, and/or software of the commercially available cochlear implant might be necessary in order to electrically restore vestibular performance. Cite this article as: Sluydts M, Leblans M, van Dinther JSJ, et al. Vestibular co-stimulation in adults with a cochlear implant. J Int Adv Otol. 2022;18(2):150-157.


  • Intraoperative recordings of electromyogenic responses from the human stapedius muscle

    by A. Zarowski, M.C. Fuentes, D. Schaudel, M. Leblans, L. De Coninck, T. Theunen, A. Vermeiren, L. Verschoren, J. van Dinther, E.F. Offeciers


  • Open Access

    Prognostic Value of Trial Round Window Stimulation for Selection of Candidates for Cochlear Implantation as Treatment for Tinnitus

    by Laure Poels, Andrzej Zarowski, Marc Leblans, Robby Vanspauwen, Joost van Dinther, Erwin Offeciers

    Electrical stimulation with cochlear implants is able to significantly suppress the tinnitus sensations in 25–72% of implanted patients. Up to this point, no clear predictors for the effectiveness of tinnitus suppression with cochlear implants have been found and this substantially limits the possibility of the application of cochlear implants for this purpose. The objective of the study was to investigate if a trial electrical round window stimulation (RWS) could be used as a diagnostic tool for identifying candidates in whom electrical stimulation would be successful as treatment for tinnitus. Thirty-four patients with unilateral severe tinnitus and ipsilateral moderate to severe sensorineural hearing loss underwent a trial RWS under local anesthesia. Thirteen patients received a cochlear implant. All patients qualified for cochlear implantation on the basis of the trial RWS showed tinnitus suppression with the implant switched on. Complete or almost complete tinnitus suppression was obtained in 77% and partial in 23%. The mean tinnitus loudness reduction was 68% (VAS score reduction from 7.7 to 2.5). False negative results are estimated not to exceed 10–15%. We conclude that significant tinnitus suppression achieved during trial RWS under local anesthesia is a simple procedure allowing the efficient identification of candidates in whom electrical stimulation with a cochlear implant would be successful as treatment for intractable tinnitus.


  • The MO-meatocanalplasty: long-term results in the narrow external auditory canal with recurrent otitis externa or the inability to wear a hearing aid

    by Glynnis De Greve, Joost van Dinther, Robby Vanspauwen, Maryn Youri, Margriet Verstreken, Andrzej Zarowski, Erwin Offeciers

    Objective The MO-meatocanalplasty is the oblique modification of the M-meatoplasty. The MO-meatocanalplasty was designed to address the superior quadrants of the meatus and the bony canal without the need for a retro-auricular incision. This retrospective analysis was performed to evaluate the long-term results of the MO-meatocanalplasty in patients with a narrow external auditory canal (EAC) with recurrent otitis externa or in patients unable to wear a hearing aid. Methods Twenty-two ears in twenty consecutive patients who received a MO-meatocanalplasty for a narrow EAC with recurrent otitis externa or the inability to wear a hearing aid were analysed retrospectively. There were no patients included with any type of previous or planned second stage tympanoplasty procedures. A follow-up period of 3 years was analysed for postoperative recurrent narrowing, the self-cleaning capacity of the EAC, the recurrence of otitis externa, the inability to wear a hearing aid, change in hearing level and for all types of aesthetical complaints. Results The MO-meatocanalplasty procedure was effective in 82% (n = 18). Postoperative recurrent narrowing was detected in 9% (n = 2). Insufficient self-cleaning capacity of the EAC was 9.1% (n = 2). The ability to wear a hearing aid was restored in all patients with the need for a hearing aid. No aesthetical complaints were reported. Conclusion The MO-meatocanalplasty is an effective, safe and aesthetical accepted procedure to address the narrow meatus and external auditory canal. With this procedure, there is no need for a retro-auricular incision in order to create a well aerated, dry and self-cleaning EAC in patients with a narrow EAC with recurrent otitis externa or in patient with the inability to wear a hearing aid.


  • Open Access

    The relationship between cochleovestibular function tests and endolymphatic hydrops grading on MRI in patients with Menière’s disease

    by Morgana Sluydts, Anja Bernaerts, Jan W Casselman, Bert De Foer, Cathérine Blaivie, Andrzej Zarowski, Joost Js van Dinther, Erwin Offeciers, Floris L Wuyts, Robby Vanspauwen

    Purpose In this retrospective study the relationship between cochleovestibular function and a magnetic resonance imaging (MRI-) based classification system of endolymphatic hydrops was investigated. Methods Seventy-eight patients with unilateral definite Menière’s disease who underwent MRI were included. The parameters of Pure Tone Audiometry (PTA), caloric irrigation test, cervical vestibular evoked myogenic potentials, and video Head Impulse Test were compared between the grades of endolymphatic hydrops (EH) and perilymphatic enhancement (PE) on MRI. Results The low-frequency PTA was significantly different between cochlear EH grades I and II (p = 0.036; Grade I: mean (Standard Deviation, SD) = 51 decibel Hearing Level (dB HL) (18 dB HL); Grade II: mean (SD) = 60 dB HL (16 dB HL)), and vestibular EH grades 0 and III (p = 0.018; Grade 0: mean (SD) = 43 dB HL (21 dB HL); Grade III: mean = 60 dB HL (10 dB HL)). The ipsilateral caloric sum of ears with vestibular EH grade I (n = 6) was increased with regards to vestibular EH grades 0 (p = 0.001), II (p < 0.001), and III (p < 0.001) (Grade 0: mean (SD) = 24°/s (15°/s); Grade I: mean (SD) = 47°/s (11°/s); Grade II: mean (SD) = 21°/s (13°/s); Grade III: mean (SD) = 16°/s (8°/s)). Conclusion According to these results we can conclude that only the highest grades of cochlear and vestibular EH seem to be associated with decreased cochleovestibular functioning