Nigel M. Allinson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nigel M. Allinson has a total of 176 co-authors. Here are the top co-authors by number of shared publications:
- Philip Evans
University of Surrey
7 shared publications Jing Li
6 shared publications- Xujiong Ye
University of Exeter
5 shared publications Boris Pokrić
4 shared publicationsHujun Yin
4 shared publications- Hujun Yin
The University of Manchester
4 shared publications
Latest Publications
- Open Access
A hybrid model for predicting human physical activity status from lifelogging data
One trend in the recent healthcare transformations is people are encouraged to monitor and manage their health based on their daily diets and physical activity habits. However, much attention of the use of operational research and analytical models in healthcare has been paid to the systematic level such as country or regional policy making or organisational issues. This paper proposes a model concerned with healthcare analytics at the individual level, which can predict human physical activity status from sequential lifelogging data collected from wearable sensors. The model has a two-stage hybrid structure (in short, MOGP-HMM) -- a multi-objective genetic programming (MOGP) algorithm in the first stage to reduce the dimensions of lifelogging data and a hidden Markov model (HMM) in the second stage for activity status prediction over time. It can be used as a decision support tool to provide real-time monitoring, statistical analysis and personalized advice to individuals, encouraging positive attitudes towards healthy lifestyles. We validate the model with the real data collected from a group of participants in the UK, and compare it with other popular two-stage hybrid models. Our experimental results show that the MOGP-HMM can achieve comparable performance. To the best of our knowledge, this is the very first study that uses the MOGP in the hybrid two-stage structure for individuals' activity status prediction. It fits seamlessly with the current trend in the UK healthcare transformation of patient empowerment as well as contributing to a strategic development for more efficient and cost-effective provision of healthcare.
Open AccessA hybrid model for predicting human physical activity status from lifelogging data
One trend in the recent healthcare transformations is people are encouraged to monitor and manage their health based on their daily diets and physical activity habits. However, much attention of the use of operational research and analytical models in healthcare has been paid to the systematic level such as country or regional policy making or organisational issues. This paper proposes a model concerned with healthcare analytics at the individual level, which can predict human physical activity status from sequential lifelogging data collected from wearable sensors. The model has a two-stage hybrid structure (in short, MOGP-HMM) -- a multi-objective genetic programming (MOGP) algorithm in the first stage to reduce the dimensions of lifelogging data and a hidden Markov model (HMM) in the second stage for activity status prediction over time. It can be used as a decision support tool to provide real-time monitoring, statistical analysis and personalized advice to individuals, encouraging positive attitudes towards healthy lifestyles. We validate the model with the real data collected from a group of participants in the UK, and compare it with other popular two-stage hybrid models. Our experimental results show that the MOGP-HMM can achieve comparable performance. To the best of our knowledge, this is the very first study that uses the MOGP in the hybrid two-stage structure for individuals' activity status prediction. It fits seamlessly with the current trend in the UK healthcare transformation of patient empowerment as well as contributing to a strategic development for more efficient and cost-effective provision of healthcare.
- Open Access
MRI Brain Tumor Segmentation using Random Forests and Fully Convolutional Networks
In this paper, we propose a novel learning based method for automated segmentation of brain tumor in multimodal MRI images, which incorporates two sets of machine -learned and hand crafted features. Fully convolutional networks (FCN) forms the machine learned features and texton based features are considered as hand-crafted features. Random forest (RF) is used to classify the MRI image voxels into normal brain tissues and different parts of tumors, i.e. edema, necrosis and enhancing tumor. The method was evaluated on BRATS 2017 challenge dataset. The results show that the proposed method provides promising segmentations. The mean Dice overlap measure for automatic brain tumor segmentation against ground truth is 0.86, 0.78 and 0.66 for whole tumor, core and enhancing tumor, respectively.
Open AccessMRI Brain Tumor Segmentation using Random Forests and Fully Convolutional Networks
In this paper, we propose a novel learning based method for automated segmentation of brain tumor in multimodal MRI images, which incorporates two sets of machine -learned and hand crafted features. Fully convolutional networks (FCN) forms the machine learned features and texton based features are considered as hand-crafted features. Random forest (RF) is used to classify the MRI image voxels into normal brain tissues and different parts of tumors, i.e. edema, necrosis and enhancing tumor. The method was evaluated on BRATS 2017 challenge dataset. The results show that the proposed method provides promising segmentations. The mean Dice overlap measure for automatic brain tumor segmentation against ground truth is 0.86, 0.78 and 0.66 for whole tumor, core and enhancing tumor, respectively.
- Top Cited PapersOpen Access
Automatic Individual Pig Detection and Tracking in Pig Farms
Individual pig detection and tracking is an important requirement in many video-based pig monitoring applications. However, it still remains a challenging task in complex scenes, due to problems of light fluctuation, similar appearances of pigs, shape deformations, and occlusions. In order to tackle these problems, we propose a robust on-line multiple pig detection and tracking method which does not require manual marking or physical identification of the pigs and works under both daylight and infrared (nighttime) light conditions. Our method couples a CNN-based detector and a correlation filter-based tracker via a novel hierarchical data association algorithm. In our method, the detector gains the best accuracy/speed trade-off by using the features derived from multiple layers at different scales in a one-stage prediction network. We define a tag-box for each pig as the tracking target, from which features with a more local scope are extracted for learning, and the multiple object tracking is conducted in a key-points tracking manner using learned correlation filters. Under challenging conditions, the tracking failures are modelled based on the relations between responses of the detector and tracker, and the data association algorithm allows the detection hypotheses to be refined; meanwhile the drifted tracks can be corrected by probing the tracking failures followed by the re-initialization of tracking. As a result, the optimal tracklets can sequentially grow with on-line refined detections, and tracking fragments are correctly integrated into respective tracks while keeping the original identifications. Experiments with a dataset captured from a commercial farm show that our method can robustly detect and track multiple pigs under challenging conditions. The promising performance of the proposed method also demonstrates the feasibility of long-term individual pig tracking in a complex environment and thus promises commercial potential.
Top Cited PapersOpen AccessAutomatic Individual Pig Detection and Tracking in Pig Farms
Individual pig detection and tracking is an important requirement in many video-based pig monitoring applications. However, it still remains a challenging task in complex scenes, due to problems of light fluctuation, similar appearances of pigs, shape deformations, and occlusions. In order to tackle these problems, we propose a robust on-line multiple pig detection and tracking method which does not require manual marking or physical identification of the pigs and works under both daylight and infrared (nighttime) light conditions. Our method couples a CNN-based detector and a correlation filter-based tracker via a novel hierarchical data association algorithm. In our method, the detector gains the best accuracy/speed trade-off by using the features derived from multiple layers at different scales in a one-stage prediction network. We define a tag-box for each pig as the tracking target, from which features with a more local scope are extracted for learning, and the multiple object tracking is conducted in a key-points tracking manner using learned correlation filters. Under challenging conditions, the tracking failures are modelled based on the relations between responses of the detector and tracker, and the data association algorithm allows the detection hypotheses to be refined; meanwhile the drifted tracks can be corrected by probing the tracking failures followed by the re-initialization of tracking. As a result, the optimal tracklets can sequentially grow with on-line refined detections, and tracking fragments are correctly integrated into respective tracks while keeping the original identifications. Experiments with a dataset captured from a commercial farm show that our method can robustly detect and track multiple pigs under challenging conditions. The promising performance of the proposed method also demonstrates the feasibility of long-term individual pig tracking in a complex environment and thus promises commercial potential.
- Open Access
- 1 April 2018
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 157, 69-84
Supervised learning based multimodal MRI brain tumour segmentation using texture features from supervoxels
- 1 April 2018
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 157, 69-84
Open AccessSupervised learning based multimodal MRI brain tumour segmentation using texture features from supervoxels
- Open Access
- 20 September 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 12 (2) , 183-203
Automated brain tumour detection and segmentation using superpixel-based extremely randomized trees in FLAIR MRI
Purpose We propose a fully automated method for detection and segmentation of the abnormal tissue associated with brain tumour (tumour core and oedema) from Fluid- Attenuated Inversion Recovery (FLAIR) Magnetic Resonance Imaging (MRI). Methods The method is based on superpixel technique and classification of each superpixel. A number of novel image features including intensity-based, Gabor textons, fractal analysis and curvatures are calculated from each superpixel within the entire brain area in FLAIR MRI to ensure a robust classification. Extremely randomized trees (ERT) classifier is compared with support vector machine (SVM) to classify each superpixel into tumour and non-tumour. Results The proposed method is evaluated on two datasets: (1) Our own clinical dataset: 19 MRI FLAIR images of patients with gliomas of grade II to IV, and (2) BRATS 2012 dataset: 30 FLAIR images with 10 low-grade and 20 high-grade gliomas. The experimental results demonstrate the high detection and segmentation performance of the proposed method using ERT classifier. For our own cohort, the average detection sensitivity, balanced error rate and the Dice overlap measure for the segmented tumour against the ground truth are 89.48 %, 6 % and 0.91, respectively, while, for the BRATS dataset, the corresponding evaluation results are 88.09 %, 6 % and 0.88, respectively. Conclusions This provides a close match to expert delineation across all grades of glioma, leading to a faster and more reproducible method of brain tumour detection and delineation to aid patient management.
- 20 September 2016
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 12 (2) , 183-203
Open AccessAutomated brain tumour detection and segmentation using superpixel-based extremely randomized trees in FLAIR MRI
Purpose We propose a fully automated method for detection and segmentation of the abnormal tissue associated with brain tumour (tumour core and oedema) from Fluid- Attenuated Inversion Recovery (FLAIR) Magnetic Resonance Imaging (MRI). Methods The method is based on superpixel technique and classification of each superpixel. A number of novel image features including intensity-based, Gabor textons, fractal analysis and curvatures are calculated from each superpixel within the entire brain area in FLAIR MRI to ensure a robust classification. Extremely randomized trees (ERT) classifier is compared with support vector machine (SVM) to classify each superpixel into tumour and non-tumour. Results The proposed method is evaluated on two datasets: (1) Our own clinical dataset: 19 MRI FLAIR images of patients with gliomas of grade II to IV, and (2) BRATS 2012 dataset: 30 FLAIR images with 10 low-grade and 20 high-grade gliomas. The experimental results demonstrate the high detection and segmentation performance of the proposed method using ERT classifier. For our own cohort, the average detection sensitivity, balanced error rate and the Dice overlap measure for the segmented tumour against the ground truth are 89.48 %, 6 % and 0.91, respectively, while, for the BRATS dataset, the corresponding evaluation results are 88.09 %, 6 % and 0.88, respectively. Conclusions This provides a close match to expert delineation across all grades of glioma, leading to a faster and more reproducible method of brain tumour detection and delineation to aid patient management.
- Open Access
- 1 September 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1053) , 20150134
Proton radiography and tomography with application to proton therapy
Proton radiography and tomography have long promised benefit for proton therapy. Their first suggestion was in the early 1960s and the first published proton radiographs and CT images appeared in the late 1960s and 1970s, respectively. More than just providing anatomical images, proton transmission imaging provides the potential for the more accurate estimation of stopping-power ratio inside a patient and hence improved treatment planning and verification. With the recent explosion in growth of clinical proton therapy facilities, the time is perhaps ripe for the imaging modality to come to the fore. Yet many technical challenges remain to be solved before proton CT scanners become commonplace in the clinic. Research and development in this field is currently more active than at any time with several prototype designs emerging. This review introduces the principles of proton radiography and tomography, their historical developments, the raft of modern prototype systems and the primary design issues.
- 1 September 2015
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 88 (1053) , 20150134
Open AccessProton radiography and tomography with application to proton therapy
Proton radiography and tomography have long promised benefit for proton therapy. Their first suggestion was in the early 1960s and the first published proton radiographs and CT images appeared in the late 1960s and 1970s, respectively. More than just providing anatomical images, proton transmission imaging provides the potential for the more accurate estimation of stopping-power ratio inside a patient and hence improved treatment planning and verification. With the recent explosion in growth of clinical proton therapy facilities, the time is perhaps ripe for the imaging modality to come to the fore. Yet many technical challenges remain to be solved before proton CT scanners become commonplace in the clinic. Research and development in this field is currently more active than at any time with several prototype designs emerging. This review introduces the principles of proton radiography and tomography, their historical developments, the raft of modern prototype systems and the primary design issues.
- Open Access
- 26 November 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (24) , 7905-7918
Proton computed tomography reconstruction using a backprojection-then-filtering approach
A novel approach to proton CT reconstruction using backprojection-then-filtering (BPF) is proposed. A list-mode algorithm is formulated accommodating non-linear proton paths. The analytical form is derived for the deblurring kernel necessary for the filtering step. Further, a finite matrix correction is derived to correct for the limited size of the backprojection matrix. High quantitative accuracy in relative stopping power is demonstrated (⩽0.1%) using Monte Carlo simulations. This accuracy makes the algorithm a promising candidate for future proton CT systems in proton therapy applications. For the purposes of reconstruction, each proton path in the object-of-interest was estimated based on a cubic spline fit to the proton entry and exit vectors. The superior spatial-resolution of the BPF method over the standard filtering-then-backprojection approach is demonstrated. As the BPF algorithm requires only one backprojection and filtering operation on a scan data set, it also offers computational advantages over an iterative reconstruction approach.
- 26 November 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (24) , 7905-7918
Open AccessProton computed tomography reconstruction using a backprojection-then-filtering approach
A novel approach to proton CT reconstruction using backprojection-then-filtering (BPF) is proposed. A list-mode algorithm is formulated accommodating non-linear proton paths. The analytical form is derived for the deblurring kernel necessary for the filtering step. Further, a finite matrix correction is derived to correct for the limited size of the backprojection matrix. High quantitative accuracy in relative stopping power is demonstrated (⩽0.1%) using Monte Carlo simulations. This accuracy makes the algorithm a promising candidate for future proton CT systems in proton therapy applications. For the purposes of reconstruction, each proton path in the object-of-interest was estimated based on a cubic spline fit to the proton entry and exit vectors. The superior spatial-resolution of the BPF method over the standard filtering-then-backprojection approach is demonstrated. As the BPF algorithm requires only one backprojection and filtering operation on a scan data set, it also offers computational advantages over an iterative reconstruction approach.
- 1 September 2014
- Published by Elsevier in Information Sciences
- Vol. 277, 406-420
Building recognition in urban environments: A survey of state-of-the-art and future challenges
- 1 September 2014
- Published by Elsevier in Information Sciences
- Vol. 277, 406-420
Building recognition in urban environments: A survey of state-of-the-art and future challenges
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10514651,p. 2113-2118
A J-Linkage Based Approach for Vanishing Direction Estimation in Catadioptric Images
This paper presents a new method for the extraction and clustering of Catadioptric Line Images (CLIs) from a single catadioptric image. The estimation of vanishing directions is also achieved simultaneously. With the mirror parameters provided, the central catadioptric system can be fully calibrated using the projected mirror boundary. Once the system is fully calibrated, the problem of conic fitting is reduced from five parameters to two parameters. This method requires the central catadioptric system to be vertically aligned i.e. the mirror axis is orthogonal to the floor. In a man-made environment where lots of parallel and orthogonal lines are presented, placing the catadioptric system in such a way allows us to obtain some degenerate CLIs, e.g. projections of lines orthogonal or parallel to the mirror axis. In this paper, we integrate the geometric properties associated with the degenerate CLIs into a J-linkage based algorithm for CLIs clustering and Vanishing Points (VPs) estimation. An exhaustive analysis on the influence of arc occlusion and noise to CLI fitting and grouping is also performed. The proposed approach is targeted to tackle the problem of occlusion and noise. The evaluation of the method is carried out on both synthetic and real data.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10514651,p. 2113-2118
A J-Linkage Based Approach for Vanishing Direction Estimation in Catadioptric Images
This paper presents a new method for the extraction and clustering of Catadioptric Line Images (CLIs) from a single catadioptric image. The estimation of vanishing directions is also achieved simultaneously. With the mirror parameters provided, the central catadioptric system can be fully calibrated using the projected mirror boundary. Once the system is fully calibrated, the problem of conic fitting is reduced from five parameters to two parameters. This method requires the central catadioptric system to be vertically aligned i.e. the mirror axis is orthogonal to the floor. In a man-made environment where lots of parallel and orthogonal lines are presented, placing the catadioptric system in such a way allows us to obtain some degenerate CLIs, e.g. projections of lines orthogonal or parallel to the mirror axis. In this paper, we integrate the geometric properties associated with the degenerate CLIs into a J-linkage based algorithm for CLIs clustering and Vanishing Points (VPs) estimation. An exhaustive analysis on the influence of arc occlusion and noise to CLI fitting and grouping is also performed. The proposed approach is targeted to tackle the problem of occlusion and noise. The evaluation of the method is carried out on both synthetic and real data.
- 9 June 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (13) , 3533-3554
Performance of a novel wafer scale CMOS active pixel sensor for bio-medical imaging
Recently CMOS active pixels sensors (APSs) have become a valuable alternative to amorphous silicon and selenium flat panel imagers (FPIs) in bio-medical imaging applications. CMOS APSs can now be scaled up to the standard 20 cm diameter wafer size by means of a reticle stitching block process. However, despite wafer scale CMOS APS being monolithic, sources of non-uniformity of response and regional variations can persist representing a significant challenge for wafer scale sensor response. Non-uniformity of stitched sensors can arise from a number of factors related to the manufacturing process, including variation of amplification, variation between readout components, wafer defects and process variations across the wafer due to manufacturing processes. This paper reports on an investigation into the spatial non-uniformity and regional variations of a wafer scale stitched CMOS APS. For the first time a per-pixel analysis of the electro-optical performance of a wafer CMOS APS is presented, to address inhomogeneity issues arising from the stitching techniques used to manufacture wafer scale sensors. A complete model of the signal generation in the pixel array has been provided and proved capable of accounting for noise and gain variations across the pixel array. This novel analysis leads to readout noise and conversion gain being evaluated at pixel level, stitching block level and in regions of interest, resulting in a coefficient of variation ⩽1.9%. The uniformity of the image quality performance has been further investigated in a typical x-ray application, i.e. mammography, showing a uniformity in terms of CNR among the highest when compared with mammography detectors commonly used in clinical practice. Finally, in order to compare the detection capability of this novel APS with the technology currently used (i.e. FPIs), theoretical evaluation of the detection quantum efficiency (DQE) at zero-frequency has been performed, resulting in a higher DQE for this detector compared to FPIs. Optical characterization, x-ray contrast measurements and theoretical DQE evaluation suggest that a trade off can be found between the need of a large imaging area and the requirement of a uniform imaging performance, making the DynAMITe large area CMOS APS suitable for a range of bio-medical applications.
- 9 June 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (13) , 3533-3554
Performance of a novel wafer scale CMOS active pixel sensor for bio-medical imaging
Recently CMOS active pixels sensors (APSs) have become a valuable alternative to amorphous silicon and selenium flat panel imagers (FPIs) in bio-medical imaging applications. CMOS APSs can now be scaled up to the standard 20 cm diameter wafer size by means of a reticle stitching block process. However, despite wafer scale CMOS APS being monolithic, sources of non-uniformity of response and regional variations can persist representing a significant challenge for wafer scale sensor response. Non-uniformity of stitched sensors can arise from a number of factors related to the manufacturing process, including variation of amplification, variation between readout components, wafer defects and process variations across the wafer due to manufacturing processes. This paper reports on an investigation into the spatial non-uniformity and regional variations of a wafer scale stitched CMOS APS. For the first time a per-pixel analysis of the electro-optical performance of a wafer CMOS APS is presented, to address inhomogeneity issues arising from the stitching techniques used to manufacture wafer scale sensors. A complete model of the signal generation in the pixel array has been provided and proved capable of accounting for noise and gain variations across the pixel array. This novel analysis leads to readout noise and conversion gain being evaluated at pixel level, stitching block level and in regions of interest, resulting in a coefficient of variation ⩽1.9%. The uniformity of the image quality performance has been further investigated in a typical x-ray application, i.e. mammography, showing a uniformity in terms of CNR among the highest when compared with mammography detectors commonly used in clinical practice. Finally, in order to compare the detection capability of this novel APS with the technology currently used (i.e. FPIs), theoretical evaluation of the detection quantum efficiency (DQE) at zero-frequency has been performed, resulting in a higher DQE for this detector compared to FPIs. Optical characterization, x-ray contrast measurements and theoretical DQE evaluation suggest that a trade off can be found between the need of a large imaging area and the requirement of a uniform imaging performance, making the DynAMITe large area CMOS APS suitable for a range of bio-medical applications.