Yassine Sayouti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yassine Sayouti has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Abdelmajid Badri
Department of Electrical Engineering, EEA&TI Laboratory, Faculty of Science and Technology (FSTM), Hassan II University of Casablanca, BP 146 Mohammedia 20650, Morocco
6 shared publications- Ahmed Abbou
Mohammed V University in Rabat
5 shared publications H. Mahmoudi
Mohammedia School's of Engineer, LEEP Rabat, Morocco
4 shared publicationsHicham Lhachimi
4 shared publicationsM. Akherraz
Mohammedia School's of Engineer, LEEP Rabat, Morocco
4 shared publicationsMarouane Lagouir
Department of Electrical Engineering, EEA&TI Laboratory, Faculty of Science and Technology (FSTM), Hassan II University of Casablanca, BP 146 Mohammedia 20650, Morocco
4 shared publications
Latest Publications
- 2 January 2026
- Published by Springer Nature
- p. 182-194
Modeling and Design of a Three-Phase Bidirectional AC-DC Inverter with Adaptive PI Controller
- 2 January 2026
- Published by Springer Nature
- p. 182-194
Modeling and Design of a Three-Phase Bidirectional AC-DC Inverter with Adaptive PI Controller
- Open Access
- 5 August 2021
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 10 (4) , 911-922
Solving Multi-Objective Energy Management of a DC Microgrid using Multi-Objective Multiverse Optimization
This paper deals with the multi-objective optimization dispatch (MOOD) problem in a DC microgrid. The aim is to formulate the MOOD to simultaneously minimize the operating cost, pollutant emission level of (NOx, SO2 and CO2) and the power loss of conversion devices. Taking into account the equality and inequality constraints of the system. Two approaches have been adopted to solve the MOOD issue. The scalarization approach is first introduced, which combines the weighted sum method with price penalty factor to aggregate objective functions and obtain Pareto optimal solutions. Whilst, the Pareto approach is based on the implementation of evolutionary multi-objective optimization solution. Single and multi-objective versions of multi-verse optimizer algorithm are, respectively, employed in both approaches to handle the MOOD. For each time step, a fuzzy set theory is selected to find the best compromise solution in the Pareto optimal set. The simulation results reveal that the Pareto approach achieves the best performances with a considerable decrease of 28.96 $/day in the daily operating cost, a slight reduction in the power loss of conversion devices from 419.79 kWh to 419.29 kWh, and in less computational time. While, it is noticing a small increment in the pollutant emission level from 11.54 kg/day to 12.21 kg/day, for the daily microgrid operation. This deviation can be fully covered when comparing the cost related to the treatment of these pollutants, which is only 5.55 $/day, to the significant reduction in the operating cost obtained using the Pareto approach.
- 5 August 2021
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 10 (4) , 911-922
Open AccessSolving Multi-Objective Energy Management of a DC Microgrid using Multi-Objective Multiverse Optimization
This paper deals with the multi-objective optimization dispatch (MOOD) problem in a DC microgrid. The aim is to formulate the MOOD to simultaneously minimize the operating cost, pollutant emission level of (NOx, SO2 and CO2) and the power loss of conversion devices. Taking into account the equality and inequality constraints of the system. Two approaches have been adopted to solve the MOOD issue. The scalarization approach is first introduced, which combines the weighted sum method with price penalty factor to aggregate objective functions and obtain Pareto optimal solutions. Whilst, the Pareto approach is based on the implementation of evolutionary multi-objective optimization solution. Single and multi-objective versions of multi-verse optimizer algorithm are, respectively, employed in both approaches to handle the MOOD. For each time step, a fuzzy set theory is selected to find the best compromise solution in the Pareto optimal set. The simulation results reveal that the Pareto approach achieves the best performances with a considerable decrease of 28.96 $/day in the daily operating cost, a slight reduction in the power loss of conversion devices from 419.79 kWh to 419.29 kWh, and in less computational time. While, it is noticing a small increment in the pollutant emission level from 11.54 kg/day to 12.21 kg/day, for the daily microgrid operation. This deviation can be fully covered when comparing the cost related to the treatment of these pollutants, which is only 5.55 $/day, to the significant reduction in the operating cost obtained using the Pareto approach.
- Open Access
- 10 January 2021
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 10 (2) , 333-343
Multi-Objective Optimization Dispatch Based Energy Management of A Microgrid Running Under Grid Connected and Standalone Operation Mode
This paper presents a novel optimization approach for a day-ahead power management and control of a DC microgrid (MG). The multi-objective optimization dispatch (MOOD) problem involves minimizing the overall operating cost, pollutant emission levels of (NOx, SO2 and CO2) and the power loss cost of the conversion devices. The weighted sum method is selected to convert the multi-objective optimization problem into a single optimization problem. Then, analytic hierarchy process (AHP) method is applied to determine the weight coefficients, according to the preference of each objective function. The system’s performance is evaluated under both grid connected and standalone operation mode, considering power balancing, high level penetration of renewable energy, optimal scheduling of charging/discharging of battery storage system, control of load curtailment and the system technical constraints. Ant lion optimizer (ALO) method is considered for handling MOOD, and the performance of the proposed algorithm is compared with other known heuristic optimization techniques. The simulation results prove the effectiveness and the capability of the developed approach to deal better with the coordinated control and optimization dispatch problem.They also revealed that economically running the MG system under grid connected mode can reduce the overall cost by around 4.70% compared to when it is in standalone operation mode.
- 10 January 2021
- Published by Center of Biomass and Renewable Energy Scientia Academy in International Journal of Renewable Energy Development
- Vol. 10 (2) , 333-343
Open AccessMulti-Objective Optimization Dispatch Based Energy Management of A Microgrid Running Under Grid Connected and Standalone Operation Mode
This paper presents a novel optimization approach for a day-ahead power management and control of a DC microgrid (MG). The multi-objective optimization dispatch (MOOD) problem involves minimizing the overall operating cost, pollutant emission levels of (NOx, SO2 and CO2) and the power loss cost of the conversion devices. The weighted sum method is selected to convert the multi-objective optimization problem into a single optimization problem. Then, analytic hierarchy process (AHP) method is applied to determine the weight coefficients, according to the preference of each objective function. The system’s performance is evaluated under both grid connected and standalone operation mode, considering power balancing, high level penetration of renewable energy, optimal scheduling of charging/discharging of battery storage system, control of load curtailment and the system technical constraints. Ant lion optimizer (ALO) method is considered for handling MOOD, and the performance of the proposed algorithm is compared with other known heuristic optimization techniques. The simulation results prove the effectiveness and the capability of the developed approach to deal better with the coordinated control and optimization dispatch problem.They also revealed that economically running the MG system under grid connected mode can reduce the overall cost by around 4.70% compared to when it is in standalone operation mode.
- 1 July 2020
- Published by Elsevier in Journal of the Franklin Institute
- Vol. 357 (11) , 6498-6538
Control of a flexible microgrid during both modes of operations with presence of nonlinear loads
- 1 July 2020
- Published by Elsevier in Journal of the Franklin Institute
- Vol. 357 (11) , 6498-6538
Control of a flexible microgrid during both modes of operations with presence of nonlinear loads
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Optimal Energy Management System of Islanded Hybrid AC/DC Microgrid
This paper deals with the optimization problem in a microgrid, and proposes more reasonable strategy for optimal energy management. The system is designed in a multi-layer structure combining a fuzzy logic system as the main controller with a conventional algorithm. The performance and effectiveness of the developed strategy are evaluated in two case studies taking into account power balancing, ensuring high penetration of renewable energy sources, monitoring the battery state of charge and fuel cost function optimization with consideration to some objective constraints. The simulation results show the accuracy and efficiency of the proposed approach.
- 1 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Optimal Energy Management System of Islanded Hybrid AC/DC Microgrid
This paper deals with the optimization problem in a microgrid, and proposes more reasonable strategy for optimal energy management. The system is designed in a multi-layer structure combining a fuzzy logic system as the main controller with a conventional algorithm. The performance and effectiveness of the developed strategy are evaluated in two case studies taking into account power balancing, ensuring high penetration of renewable energy sources, monitoring the battery state of charge and fuel cost function optimization with consideration to some objective constraints. The simulation results show the accuracy and efficiency of the proposed approach.
- 1 October 2018
- Published by Elsevier in Computers and Electrical Engineering
- Vol. 71, 637-656
Optimal improvement of direct power control strategy based on sliding mode controllers
- 1 October 2018
- Published by Elsevier in Computers and Electrical Engineering
- Vol. 71, 637-656
Optimal improvement of direct power control strategy based on sliding mode controllers
- 31 May 2018
- Published by Praise Worthy Prize in International Review of Automatic Control (IREACO)
- Vol. 11 (3) , 113
The Comparison and Analysis of the DFIG Behavior Under PI, Fuzzy and Sliding Mode Controllers for Wind Energy Conversion System in the Grid Connected Mode
In this paper, the vector control strategy along with a non linear control are applied to the doubly fed induction generator (DFIG) based wind energy. Three control strategies (PI, Fuzzy and sliding mode control) are explained, analysed and compared in terms of response time, harmonic filtering and robustness to the parametric variation. These control strategies are evaluated in the steady and transient state to control both the active and the reactive power in the grid connected mode. The analysis of the DFIG behaviour under the mentioned control strategies is verified in the simulations. Also, a representation of numerical results is displayed in a summary table. The three strategies control present some advantages and drawbacks in term of performances when they operate with power optimization and power limitation strategies. However, the sliding mode control is better under the parameters variation and speed change. Although, the fuzzy control delivers a fast response time and presents a good harmonic distortion value(THD) while the PI control ensures a perfect precision during constant wind speeds. Copyright © 2018 Praise Worthy Prize - All rights reserved.
- 31 May 2018
- Published by Praise Worthy Prize in International Review of Automatic Control (IREACO)
- Vol. 11 (3) , 113
The Comparison and Analysis of the DFIG Behavior Under PI, Fuzzy and Sliding Mode Controllers for Wind Energy Conversion System in the Grid Connected Mode
In this paper, the vector control strategy along with a non linear control are applied to the doubly fed induction generator (DFIG) based wind energy. Three control strategies (PI, Fuzzy and sliding mode control) are explained, analysed and compared in terms of response time, harmonic filtering and robustness to the parametric variation. These control strategies are evaluated in the steady and transient state to control both the active and the reactive power in the grid connected mode. The analysis of the DFIG behaviour under the mentioned control strategies is verified in the simulations. Also, a representation of numerical results is displayed in a summary table. The three strategies control present some advantages and drawbacks in term of performances when they operate with power optimization and power limitation strategies. However, the sliding mode control is better under the parameters variation and speed change. Although, the fuzzy control delivers a fast response time and presents a good harmonic distortion value(THD) while the PI control ensures a perfect precision during constant wind speeds. Copyright © 2018 Praise Worthy Prize - All rights reserved.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Microgrid Sizing with Environmental and Economic Optimization
Hybrid microgrid is the best system to build for the lower demand mainly in the non-electrified rural area. However, a hybrid system based on PV, wind turbine, diesel and Battery Energy Storage System (BESS) must be optimized. In this paper, Multi-Objective Particle Swarm Optimization (MOPSO) method is used to design the hybrid system. Net Present Cost (NPC) that cover all capital, operation maintenance and replacement cost, and emission cost to evaluate the damage caused by the pollution are the choosen obective functions. Two location area are considered to sizing the hybrid system taking in account reliability with Loss of Power Supply Probability (LPSP), Fraction Renewable (FR) that must be upper to 90% and availability should be upper to 96%. A Pareto-optimal solution using Pareto frontier give the best results with highest reliability and availability of this system.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Microgrid Sizing with Environmental and Economic Optimization
Hybrid microgrid is the best system to build for the lower demand mainly in the non-electrified rural area. However, a hybrid system based on PV, wind turbine, diesel and Battery Energy Storage System (BESS) must be optimized. In this paper, Multi-Objective Particle Swarm Optimization (MOPSO) method is used to design the hybrid system. Net Present Cost (NPC) that cover all capital, operation maintenance and replacement cost, and emission cost to evaluate the damage caused by the pollution are the choosen obective functions. Two location area are considered to sizing the hybrid system taking in account reliability with Loss of Power Supply Probability (LPSP), Fraction Renewable (FR) that must be upper to 90% and availability should be upper to 96%. A Pareto-optimal solution using Pareto frontier give the best results with highest reliability and availability of this system.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimal microgrid sizing and daily capacity stored analysis in summer and winter season
This paper presents an optimal sizing for hybrid microgrid based on photovoltaic, wind, diesel and battery energy storage system. Evolutionary algorithms (EA) are used in order to optimize the Net Present Cost (NPC) respecting reliability constraints like the Loss of Power Supply Probability (LPSP), Availability and Renewable Fraction (RF). Particle swarm optimization (PSO) and invasive weeds optimization (IWO) algorithms are compared in this paper. Battery storage is considered in summer and winter to determine their daily storage. The results of this study show that PSO converges to the best solution with NPC 59899.91$ and LCOE of 0.384 $/kWh, Furthermore, the battery is most used and most efficacy in summer than the winter.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Optimal microgrid sizing and daily capacity stored analysis in summer and winter season
This paper presents an optimal sizing for hybrid microgrid based on photovoltaic, wind, diesel and battery energy storage system. Evolutionary algorithms (EA) are used in order to optimize the Net Present Cost (NPC) respecting reliability constraints like the Loss of Power Supply Probability (LPSP), Availability and Renewable Fraction (RF). Particle swarm optimization (PSO) and invasive weeds optimization (IWO) algorithms are compared in this paper. Battery storage is considered in summer and winter to determine their daily storage. The results of this study show that PSO converges to the best solution with NPC 59899.91$ and LCOE of 0.384 $/kWh, Furthermore, the battery is most used and most efficacy in summer than the winter.