MVMarina Vlajković

Marina Vlajković

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marina Vlajković has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Myocardial perfusion scintigraphy in the prediction of the existence of hemodynamically significant coronary artery stenosis

    by Miloš Stević, Marina Vlajković, Filip Veličković, Tamara Anđelković, Nina Topić

    Anatomically insignificant stenosis of coronary arteries obtained on coronary angiography, in numerous cases can show hemodynamic significance and as such cause ischemic myocardial changes. The goal was to assess the diagnostic accuracy of myocardial perfusion scintigraphy (SPECT MPI) in the detection of hemodinamically significant coronary artery stenosis in patients with moderate risk for ischemia, without previously detected coronary disease. The study included 258 patients, of which 54% females and 46% males, with an average age of 59.0 ± 10.1 years. SPECT MPI was done by a two-day protocol with 99 mTc-MIBI. The pathological finding was the existence of perfusion defects. The physical stress test was done by Bruce protocol. Coronary angiography (CA) was performed according to a standard protocol in patients with pathological SPECT MPI findings (n = 128). Anatomically significant coronary artery narrowing was > 70%. Stenoses from 30% to 69% were considered hemodynamically significant in patients with reversible perfusion defects on SPECT MPI. The sensitivity (SE) of SPECT MPI was 89%, specificity (SP) 42%, positive predictive value (PPV) 86%, negative predictive value (NPV) 50%, and total diagnostic accuracy (ACC) was 74% when the results were compared with stenosis > 70%. By including stenosis from 30% to 69%, the obtained values of diagnostic indicators of SPECT MPI reliability were: SE 91%; SP 100%; PPV 100%; NPV 50% and ACC 91%. With CA only, it is not possible to prove the existence of hemodynamic significance of coronary artery stenoses from 30% to 69%, which represents a recruitment range for developing ischemia. SPECT MPI shows high SE, SP, PPV, and ACC in detecting the existence of left ventricular myocardium perfusion disorder in either stenosis of coronary arteries with or without anatomically significant value.

  • Open Access

    Theranostics and precision medicine In neuroendocrine tumors

    by Filip Veličković, Marina Vlajković, Miloš Stević, Nina Topić, Tamara Anđelković, Đuro Macut

    Neuroendocrine tumors (NETs) have increased expression of somatostatin receptors (SSTR), where subtype 2 and 5 are the most common. Overexpression of the SSTR is an outstanding molecular target for inoperable and metastatic NETs that enables a unique approach of targeted diagnosis and treatment. In addition to SSTRs, neuroendocrine tumors also express other receptors that can be suitable targets for visualization by nuclear medicine methods. This review paper is focused on the most common radiopharmaceuticals and their molecular targets that are used today based on theranostic approach in NETs. In conventional nuclear medicine, the most important diagnostic radiopharmaceuticals are somatostatin analogs (SSA) labeled with 111 In and 99m Tc, however 99m Tc has advantages over 111 In based on better physical characteristics and better performance. In recent years, highly potent theranostic pairs have been created for the imaging and treatment of NETs, which can strongly bind SSTR. Derivatives of 68 Ga-labeled octreotide are recommended for diagnostics and follow-up of NENs. The great advantage of 68 Ga radiopharmaceuticals is that identical compounds can be labeled with therapeutic radionuclides 90 Y and 177 Lu. Peptide receptor radionuclide therapy is a systemic molecular target therapy that has proven to be safe and very effective in controlling the disease and prolonging the survival of patients with advanced and inoperable NETs. With a negligible number of adverse events, this therapy is safe and should be administered to all patients who meet the necessary criterias, primarily overexpression of the somatostatin receptor type 2.


  • Open Access

    The significance of metaiodobenzylguanidine scintigraphy in the treatment of high risk neuroblastomas

    by Katarina Nikolić, Marina Vlajković

    Introduction: Neuroblastoma cells show the expression of norepinephrine transporters enabling the intercellular location of mIBG, which turned out to be ideal for the visualization of neuroblastoma, as well as for the treatment of these tumors in certain cases. Aim: The aim of this retrospective analysis is to show the possibilities of the 131/123J-mIBG scintigraphy in detecting primary tumor as well as in determining the presence and localization of metastatic lesions in children with neuroblastoma. Material and methods: The investigation was carried out in 17 subjects, 7 boys and 10 girls, aged 8.2 ± 7.8 (4 months to 16 years). In 10 of them the IV neuroblastoma was confirmed. A number of 7 children underwent only the diagnostic scintigraphy while in 10 of them 2-5 scans with 123/131J-mIBG were performed during follow-up. In total, there were 35 scintigraphy for the analysis. Results: A negative finding of 123/131J-mIBG scan was observed in 8 subjects. In one of them, neuroblastoma was histopathologically proven, but the scintigraphy was performed after the surgical removal of the tumor and after chemotherapy. In 9 children with scintigraphically confirmed neuroblastoma, apart from having the primary tumor, the metastatic spread of the disease was detected in the bone marrow during the initial staging. After the treatment, 4 children had a negative finding on mIBG scintigraphy, which indicated the remission, while in 2 children, the tumor relapsed; and in 4 of them, the regression of the tumor occurred after the treatment. Conclusion: The results showed high sensitivity of 123/131J-mIBG scintigraphy in detecting neuroblastoma, both the primary tumor and metastases in the bone marrow. This radiopharmaceutical turned out to be reliable for the treatment monitoring of children with neuroblastoma. Likewise, a high incidence of bone metastases was detected on the mIBG scintigraphy, as well as a the high rate of disease recurrence after therapy.

  • Open Access

    Characteristics of the scintigraphy with 99mTcpertechnetate in patients with differentiated thyroid carcinoma

    by Katarina Nikolić, Marina Vlajković

    Introduction: Differentiated thyroid carcinoma (DTC) derived from follicular cells is the most frequent endocrine malignancy, which most commonly occurs in patients with thyroid nodules. Aim: The aim of this retrospective analysis is to examine the type of scintigraphic finding of the thyroid gland obtained with 99mTc-pertechnetate in patients with DTC before tireoidectomy. Material and methods: Medical documentation comprised of 95 subjects with presurgical evaluation of thyroid nodules, including 18 men (51.5 ± 8.7 years old, range 43-68) and 77 women (48 ± 12, range 14-72 years). Other tests performed during the preoperative tests are the following: ultrasound examination of the thyroid gland, thyrotropin and thyroglobulin concentration measurement. Results: During the preoperative evaluation, thyroid ultrasound was performed in 20 (21%) out of 95 subjects with DTC, while 99mTc-pertechnetate scintigraphy was performed in 75 (79%) of patients, in addition to a clinical examination. What is the distribution of scintigraphic finding? Significantly, the highest incidence of DTC was found in the multinodular goiter: 61 (64%) subjects were diagnosed with this type of DTC, while 31 (33%) carcinomas were found in abnormal, solitary "cold" nodules. The most frequent histopathological finding amongst nodules and multinodular goiter detected by scintigraphy was papillary thyroid carcinoma. Thyroid carcinoma was found in two patients with Graves' disease and in one patient with a normal scintigraphic finding. The values of thyroid hormones were normal in 71% of DTC and elevated in fewer cases (21%). The ultrasound examination showed high-risk features in only 18 subjects (19%). Conclusion: Our results have shown that DTC is the most common finding in the multinodal goiter, and that it occurs much less often within the "cold" thyroid nodules. In a small percentage of subjects, thyroid neoplasm was found in patients with hyperthyroidism. The results of the study showed that thyroid gland scintigraphy with 99mTc-pertechnetate still has a significant diagnostic role in the examination of thyroid nodules.

  • Open Access

    Alarm system for surveillance of patients receiving high doses of radioiodine (131I) therapy in the case of unauthorised abandoning of a controlled area

    by Milovan D. Matović, Miroslav D. Ravlić, Marija Ž. Jeremić, Slobodan M. Janković, Marina Ž. Vlajković

    After receiving high doses of radioiodine the patients have to remain isolated within the ?restricted area?, until the radioactivity of the body drops below a certain level. The aim of this paper was to present our alarming system designed to discover patients who attempt to abandon the ?restricted area? and inform medical staff about the event. The system consists of a survey-meter with a pancake probe directed towards the corridor. The survey-meter is connected to a trigger circuit which gives a signal in the case when the measured count rate exceeds a preset value. This signal sets ?on? the alarm device, blinking light, programmable siren and IP camera, in order to warn the patient and inform the personnel when such a case occurs. In order to test the consistency and sensitivity of our system we measured ten times the ambient dose equivalent, H*(10), from the source of 925 MBq (25 mCi) 131I, kept at a distance of 1 m. The average ambient dose equivalent was 77.73 ? 31.57 (0.084 mSvh-1 per MBq, or 3.1 mSvh-1 per mCi). We measured ten times the same source at various distances (1-2.25 m) from the probe. In each position, the system was triggered. Also we tested the system on 40 patients treated with radioiodine instructed to pass through the corridor. Each of their attempts triggered the system. According to our experience gained over the past few years, this alarm system intended for patients receiving radionuclide therapy ensures a high level of safety for both the patients and medical staff.


  • Open Access

    Increased accuracy of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy using iterative reconstruction of images

    by Milos Stevic, Marina Vlajkovic

    Background/Aim. Filtered back projection (FBP) is a common way of processing myocardial perfusion imaging (MPI) studies. There are artifacts in FBP which can cause falsepositive results. Iterative reconstruction (IR) is developed to reduce false positive findings in MPI studies. The aim of this study was to evaluate the difference in the number of false positive findings in MPI studies, between FBP and IR processing. Methods. We examined 107 patients with angina pectoris with MPI and coronary angiography (CAG), 77 man and 30 woman, aged 32?82. MPI studies were processed with FBP and with IR. Positive finding at MPI was visualization of the perfusion defect. Positive finding at CAG was stenosis of coronary artery. Perfusion defect at MPI without coronary artery stenosis at CAG was considered like false positive. The results were statistically analyzed with bivariate correlation, and with one sample t-test. Results. There were 20.6% normal, and 79.4% pathologic findings at FBP, 30.8% normal and 69.2% pathologic with IR and 37.4% normal and 62.6% pathologic at CAG. FBP produced 19 false-positive findings, at IR 11 false positive findings. The correlation between FBP and CAG was 0.658 (p < 0.01) and between IR and CAG 0.784 (p < 0.01). The number of false positive findings at MPI with IR was significantly lower than at FBP (p < 0.01). Conclusion. Our study shows that IR processing MPI scintigraphy has less number of false positive findings, therefore it is our choice for processing MPI studies.

  • Open Access

    Diagnostic nuclear medicine in pediatric oncology-what we should know before scanning?

    by Marina Vlajkovic, Milovan Matovic

    Cancer is second only to trauma as a cause of death in children, accounting for approximately 10% of all childhood deaths. The application of radioisotopes in the treatment of malignant diseases in children consists of detecting and estimating the degree of tumour spread by application of tumour-specific and non-specific radiopharmaceuticals, as well as the treatment of some malignant diseases. Paramount to any successful nuclear medicine examination is the establishment of acquisition protocols that allow high quality images to be obtained while ALARA principles are followed. Pediatric-specific issues should be anticipated and addressed in the planning of the studies to maximize the utility of the technique in this challenging group of patients, so the goal of this article is to summarize general prerequisites for the application of nuclear medicine diagnostic procedures in pediatric oncology patients.

  • Open Access

    Sentinel node biopsy for skin melanoma

    by Predrag Kovacevic, Milan Visnjic, Marina Vlajkovic, Tatjana Kovacevic, Aleksandar Visnjic

    Background/Aim. Skin melanoma is one of the most malignant diseases with increasing incidence rate. Sentinel node biopsy (SNB) is very important for early detection of metastatic spread. The aim of the study was to analyze the first 40 patients with skin melanoma of 1 to 4 mm Breslow thickness when SNB was indicated. Methods. The patient characteristics, localization of the primary melanoma as well as histology grade were analyzed. SNB with intraoperative radiocolloid and methylene blue dye detection was performed. Results. Complication rate after SNB was analyzed and seroma was found in 5% of the patients. The therapeutic node dissection was performed in 10 patients with positive sentinel biopsy. The follow-up lasted two years. In five patients the false negative SNB was defined after the mean time of 11 months and the therapeutic dissection was performed. Conclusion. SNB in melanoma patients is a useful diagnostic procedure. It is advised for melanoma of 1 to 4 mm Breslow thickness.


  • The Significance of Radiopharmaceutical Choice on the Estimation of the Absolute Renal Function in Different Stages of Renal Failure

    by S. Ilic, M. Vlajkovic, M. Bogicevic, M. Rajic, V. Stefanovic

    Objective: An abnormal filtration fraction due to divergence between glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) may lead to different estimations of absolute renal function, depending on the radiopharmaceutical administered. The purpose of this study was to estimate GFR and ERPF by measuring the clearances of technetium-99m diethylenetriamine pen- taacetic acid (99mTc-DTPA) and iodine-131 sodium o-iodo- hippurate (131I-OIH) in patients with renal failure and evaluate the significance of these radiopharmaceuticals in the prognosis of the disease. Methods: This study included 25 patients who were followed up during different phases of acute renal failure (ARF) as well as 46 patients with incipient and advanced chronic renal failure (CRF). Results were compared with those obtained in 20 healthy volunteers. Clearance of 99mTc-DTPA and 131I-OIH was measured by the technique of a single blood sample taken 180 and 44 min after administration of the radiotracer, respectively. Results: In the patients with ARF, absolute values of GFR and ERPF decreased during oligoanuric and diuretic phases, but the lower filtration fraction suggested a greater reduction of GFR. In the recovery phase of ARF, both GFR and ERPF improved and an almost normal filtration fraction suggested a more prominent GFR increase. The recovery of ARF patients was in accordance with 131I-OIH clearance values recorded in the oligoanuric phase. The GFR and ERPF decreased concordantly in patients in the incipient stage while in advanced CRF, a slightly greater decrease in GFR was recorded. Conclusions: In ARF, the degree of the initial fall in GFR does not serve as a prognostic indicator whereas the degree of the initial fall of ERPF does have prognostic significance. The decrease in GFR parallels the decrease in ERPF in CRF and a measurement of either parameter should give a comparable estimate of renal function.