J. C. Macy
Research Subjects
J. C. Macy has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
C. E. Dumont
Department of Orthopedic Surgery, University of Zürich, Balgrist, Switzerland
1 shared publicationC. M.L. Werner
1 shared publication- Christian Gerber
Balgrist Campus Research and Development Center, Zürich, Switzerland
1 shared publication H. A.C. Jacob
1 shared publicationR. Thalmann
1 shared publication- Richard Walter Nyffeler
Orthopädie Sonnenhof, Bern, Switzerland
1 shared publication
Latest Publications
- Open Access
- 1 January 2017
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2017 (1) , 4347161
Fixation of a Proximal Humeral Fracture Using a Novel Intramedullary Cage Construct following a Failed Conservative Treatment
A majority of proximal humeral fractures are preferably treated conservatively. However, surgical management may be beneficial in proximal humeral fractures with significant displacement or angulation. Unfortunately, the complication rates associated with current surgical procedures for fracture fixation, ORIF and IM devices, can be unacceptably high. A new technology, termed the PH Cage, addresses the technical limitations associated with current technologies available for fixation of proximal humeral fractures. It allows for intramedullary fixation of a PH fracture and provides direct load bearing support to the articular surface and buttresses the medial column during healing. We are presenting our first experience with the PH Cage for the fixation of a PH fracture, which had previously failed conservative management.
- 1 January 2017
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2017 (1) , 4347161
Open AccessFixation of a Proximal Humeral Fracture Using a Novel Intramedullary Cage Construct following a Failed Conservative Treatment
A majority of proximal humeral fractures are preferably treated conservatively. However, surgical management may be beneficial in proximal humeral fractures with significant displacement or angulation. Unfortunately, the complication rates associated with current surgical procedures for fracture fixation, ORIF and IM devices, can be unacceptably high. A new technology, termed the PH Cage, addresses the technical limitations associated with current technologies available for fixation of proximal humeral fractures. It allows for intramedullary fixation of a PH fracture and provides direct load bearing support to the articular surface and buttresses the medial column during healing. We are presenting our first experience with the PH Cage for the fixation of a PH fracture, which had previously failed conservative management.
- 1 January 2003
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 85 (1) , 48-55
EFFECT OF SELECTIVE CAPSULORRHAPHY ON THE PASSIVE RANGE OF MOTION OF THE GLENOHUMERAL JOINT
Background: Capsulorrhaphy of the glenohumeral joint is a common surgical procedure for the treatment of instability caused by increased capsular laxity. The effect of capsulorrhaphy on the range of motion of the shoulder is poorly understood.
- 1 January 2003
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 85 (1) , 48-55
EFFECT OF SELECTIVE CAPSULORRHAPHY ON THE PASSIVE RANGE OF MOTION OF THE GLENOHUMERAL JOINT
Background: Capsulorrhaphy of the glenohumeral joint is a common surgical procedure for the treatment of instability caused by increased capsular laxity. The effect of capsulorrhaphy on the range of motion of the shoulder is poorly understood.
- 1 September 2002
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 84 (7) , 1070-1074
The Effect Of Rotational Malunion Of The Radius And The Ulna On Supination And Pronation: An Experimental Investigation
We have assessed the influence of isolated and combined rotational malunion of the radius and ulna on the rotation of the forearm. Osteotomies were made in both the radius and the ulna at the mid-diaphyseal level of five cadaver forearms and stabilised with intramedullary metal implants. Malunion about the axis of the respective forearm bone was produced at intervals of 10°. The ranges of pronation and supination were recorded by a potentiometer under computer control. We examined rotational malunions of 10° to 80° of either the radius or ulna alone and combined rotational malunions of 20° to 60° of both the radius and ulna.
- 1 September 2002
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 84 (7) , 1070-1074
The Effect Of Rotational Malunion Of The Radius And The Ulna On Supination And Pronation: An Experimental Investigation
We have assessed the influence of isolated and combined rotational malunion of the radius and ulna on the rotation of the forearm. Osteotomies were made in both the radius and the ulna at the mid-diaphyseal level of five cadaver forearms and stabilised with intramedullary metal implants. Malunion about the axis of the respective forearm bone was produced at intervals of 10°. The ranges of pronation and supination were recorded by a potentiometer under computer control. We examined rotational malunions of 10° to 80° of either the radius or ulna alone and combined rotational malunions of 20° to 60° of both the radius and ulna.