MLMichael R. E. Lamont

Michael R. E. Lamont

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michael R. E. Lamont has a total of 176 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Hybrid adaptive optics for high throughput volumetric OCM, and suppression of multiple scattering and speckle (Conference Presentation)

    by Siyang Liu, Michael R. E. Lamont, Jeffrey A. Mulligan, Steven G. Adie

    Optical coherence microscopy (OCM) provides non-invasive, label-free, cellular-resolution imaging based on optical scattering contrast. Its interferometric detection captures the optical field, providing opportunities for computational reconstruction. However, the depth coverage of OCM is restricted by defocus and photon collection, and its penetration depth is limited by multiple scattering (MS). Here, we propose integrating hardware and computational adaptive optics in different ways, to improve the throughput, penetration depth, and contrast of volumetric OCM. This hybrid adaptive optics (hyAO) approach splits the image formation process into a combination of hardware and computation components. For sparse sample imaging, we generated astigmatism using hardware adaptive optics (HAO) to achieve a more equalized photon distribution across depth, and removed the applied aberration (and defocus) via computational adaptive optics (CAO). We applied this hyAO method to perform 3D time-lapse imaging of in vitro fibroblast cell dynamics over a 1mm×1mm×1mm field-of-view with 2μm isotropic spatial resolution and 3-minute temporal resolution. The hyAO approach is not only beneficial for high-throughput volumetric imaging, but is also capable of suppressing MS/speckle. For scattering sample imaging, HAO was used to illuminate the sample volume with diverse aberrated point spread functions to decorrelate the MS/speckle fields, and CAO was applied to computationally mitigate the resolution penalty of these intentionally induced aberrations. By imaging with this aberration-diverse OCT using 12 volumetric reconstructions, we achieved a 10 dB enhancement in signal-to-background ratio at a USAF target plane beneath a scattering layer (7.2 scattering mean-free-path), and a 3× speckle contrast reduction within the scattering layer.

  • In Vivo Multiphoton Microscopy of the Beating Mouse Heart in Health and Disease

    by David M. Small, Michael R.E. Lamont, Nathaniel H. Alan-Rahill, Nozomi Nishimura

    In vivo multiphoton microscopy of the beating mouse heart generates cell-resolved, volumetric images parameterized by cardiorespiratory phase-space. We compare displacement and deformation profiles throughout the cardiac cycle before and after injury.


  • Aberration-diverse optical coherence tomography for suppression of multiple scattering and speckle

    by Siyang Liu, Michael R. E. Lamont, Jeffrey A. Mulligan, Steven G. Adie

    Multiple scattering is a major barrier that limits the optical imaging depth in scattering media. In order to alleviate this effect, we demonstrate aberration-diverse optical coherence tomography (AD-OCT), which exploits the phase correlation between the deterministic signals from single-scattered photons to suppress the random background caused by multiple scattering and speckle. AD-OCT illuminates the sample volume with diverse aberrated point spread functions, and computationally removes these intentionally applied aberrations. After accumulating 12 astigmatism-diverse OCT volumes, we show a 10 dB enhancement in signal-to-background ratio via a coherent average of reconstructed signals from a USAF target located 7.2 scattering mean free paths below a thick scattering layer, and a 3× speckle contrast reduction from an incoherent average of reconstructed signals inside the scattering layer. This AD-OCT method, when implemented using astigmatic illumination, is a promising approach for ultra-deep volumetric optical coherence microscopy.


  • Aberration Diverse OCT for Imaging Beyond the Multiple Scattering Limit

    by Michael R.E. Lamont, Siyang Liu, Jeffrey A. Mulligan, Steven G. Adie

    Using hardware adaptive optics to introduce optical aberrations, and computational adaptive optics to compensate their resolution penalty, we perform coherent averaging of reconstructed aberration-diverse OCT datasets to suppress the effects of multiple scattering.

  • Coherent Supercontinuum Generation with Picosecond Pulses

    by Adrea R. Johnson, Xingchen Ji, Michael R. E. Lamont, Yoshitomo Okawachi, Michal Lipson, Alexander L. Gaeta

    We theoretically show the possibility of generating a coherent, octave-spanning supercontinuum with >1-ps pulses. Our proof-of-principle experiments demonstrate the feasibility of utilizing long waveguides and multiple cross sections for supercontinuum generation at ultralow pulse energies.


  • Open Access

    Self-organization in Kerr-cavity-soliton formation in parametric frequency combs

    by Y. Henry Wen, Michael R. E. Lamont, Steven H. Strogatz, Alexander L. Gaeta

    We show that self-organization and synchronization underlie Kerr-cavity-soliton formation in parametric frequency combs. By reducing the Lugiato-Lefever equation to a set of phase equations, we find that self-organization arises from a two-stage process via pump-degenerate and pump-nondegenerate four-wave mixing. The reduced phase equations are akin to the Kuramoto model of coupled oscillators and intuitively explain the origin of the pump phase offset, predict antisymmetrization of the intracavity field before phase synchronization, and clarify the role of chaos in Kerr-cavity-soliton formation in parametric combs.


  • Gigahertz frequency comb offset stabilization based on supercontinuum generation in silicon nitride waveguides

    by Alexander Klenner, Aline S. Mayer, Adrea R. Johnson, Kevin Luke, Michael R. E. Lamont, Yoshitomo Okawachi, Michal Lipson, Alexander L. Gaeta, Ursula Keller

    Silicon nitride (Si3N4) waveguides represent a novel photonic platform that is ideally suited for energy efficient and ultrabroadband nonlinear interactions from the visible to the mid-infrared. Chip-based supercontinuum generation in Si3N4 offers a path towards a fully-integrated and highly compact comb source for sensing and time-and-frequency metrology applications. We demonstrate the first successful frequency comb offset stabilization that utilizes a Si3N4 waveguide for octave-spanning supercontinuum generation and achieve the lowest integrated residual phase noise of any diode-pumped gigahertz laser comb to date. In addition, we perform a direct comparison to a standard silica photonic crystal fiber (PCF) using the same ultrafast solid-state laser oscillator operating at 1 µm. We identify the minimal role of Raman scattering in Si3N4 as a key benefit that allows to overcome the fundamental limitations of silica fibers set by Raman-induced self-frequency shift.


  • Compact Low-Noise Frequency Combs: Microchip or Photonic Crystal Fiber?

    by Alexander Klenner, Aline S. Mayer, Adrea R. Johnson, Kevin Luke, Michael R. E. Lamont, Yoshitomo Okawachi, Michal Lipson, Alexander L. Gaeta, Ursula Keller

    We stabilize a frequency comb generated by supercontinuum from a Si3N4-microchip and compare it to that generated in silica photonic crystal fibers. For high effective nonlinearities, spontaneous Raman scattering in silica can significantly degrade the supercontinuum coherence.

  • Top Cited Papers
    Open Access

    Octave-spanning coherent supercontinuum generation in a silicon nitride waveguide

    by Adrea R. Johnson, Aline S. Mayer, Alexander Klenner, Kevin Luke, Erin S. Lamb, Michael R. E. Lamont, Chaitanya Joshi, Yoshitomo Okawachi, Frank W. Wise, Michal Lipson, et al.

    We demonstrate the generation of a supercontinuum spanning more than 1.4 octaves in a silicon nitride waveguide using sub-100-fs pulses at 1 μm generated by either a 53-MHz, diode-pumped ytterbium (Yb) fiber laser or a 1-GHz, Yb:CaAlGdO4 (Yb:CALGO) laser. Our numerical simulations show that the broadband supercontinuum is fully coherent, and a spectral interference measurement is used to verify that the supercontinuum generated with the Yb:CALGO laser possesses a high degree of coherence over the majority of its spectral bandwidth. This coherent spectrum may be utilized for optical coherence tomography, spectroscopy, and frequency metrology.


  • Top Cited Papers
    Open Access

    Broadband mid-infrared frequency comb generation in a Si_3N_4 microresonator

    by Kevin Luke, Yoshitomo Okawachi, Michael R. E. Lamont, Alexander L. Gaeta, Michal Lipson

    We demonstrate broadband frequency comb generation in the mid-infrared (MIR) from 2.3 to 3.5 μm in a Si3N4 microresonator. We engineer the dispersion of the structure in the MIR using a Sellmeier equation we derive from experimental measurements performed on Si3N4 films from the UV to the IR. We use deposition–anneal cycling to decrease absorption losses due to vibrational transitions in the MIR and achieve a Q-factor of 1.0×106. To our knowledge, this is the highest Q reported in this wavelength range for any on-chip resonator.