JLJohn Lazarus

John Lazarus

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


John Lazarus has a total of 130 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Renal trauma: an overview of current management

    by Willem Meyer du Plessis, John Michael Lazarus

    Background: Following liver and splenic injury, the kidney is the third most common abdominal organ to be injured and is frequently associated with injuries to other organs. Management has shifted to conservative treatment, which is associated with increased organ preservation. The urologist, as part of a multi-disciplinary team, must review the clinical status, associated organ injuries and imaging findings to decide how to intervene. Objectives: To provide an overview of the current management strategies and guidelines for renal trauma. Methods: A comprehensive literature review on renal trauma was conducted using the PubMed and Google Scholar databases, with a focus on recent findings and the latest guideline recommendations. Results: Sound clinical decision-making is required when selecting a management strategy. Selective non-operative management has become the new standard in haemodynamically stable patients. Advances in imaging, endoscopy and endovascular treatment have shifted the management of renal trauma towards minimally invasive approaches. Urinary diversion is reserved for cases with complications due to urinary extravasation. Renorrhaphy must be performed in suitable cases. Conclusion: Selective non-operative management has been embraced as the new standard in renal trauma, with a resultant decreased nephrectomy rate. The urologist must take all factors into account to identify those that may lead to adverse outcomes and to intervene promptly.

  • Open Access

    Correction to: Prevalence of meeting aerobic physical activity and resistance training guidelines in advanced prostate cancer: a descriptive study of racial and regional disparities in the IRONMAN registry

    by Aleksander Solberg, May Grydeland, Tormod S. Nilsen, Anne H. Storås, Ian D. Davis, Natalie Greaves, Simon Anderson, Andre P. Fay, Kim N. Chi, Deborah Enting, et al.

  • Open Access

    Integration of Robotic Surgery in African Urology: Measured Progress or Misplaced Priority? A Debate

    by Saleh A. Nedjim, Anteneh Tadesse Kifle, Bencheri Youssef, Kaleab Habtemichael Gebreselassie, Ouima J. D. Ziba, Marcella Derboise Christelle Biyouma, Abdullahi Khalid, Laurent Brureau, Obi Davies Ekwenna, Younes Ahallal, et al.

    In their article entitled “Morocco, a New Era of Robotic Surgery”, published in the Société Internationale d’Urologie Journal, El Anzaoui et al

  • The South African Prostate Biopsy Guidelines 2026

    by A Badenhorst, J Lazarus, A Adam, J John, Sba Mutambirwa, M Purdy, F Claassen, K Mathabe, A van der Merwe

  • Open Access

    Novel Dual-Action Pump Shows Promise to Reduce Intra-Renal Pressure and Improve Irrigant Flow in Flexible Ureteroscopy

    by Mark Wellmann, Jeff John, John Lazarus

    Background/Objective: To describe a novel dual-action pump (DAP) which is hypothesised to reduce mean intrarenal pressure (IRP) and increase irrigation flow during flexible ureterorenoscopy (fURS). The DAP incorporates a low-volume, user-controlled pumping/suctioning unit, to precisely control fluid boluses into the upper urinary tract via a ureterorenoscope and simultaneously draws out an identical volume of the delivered irrigant via a syphoning UAS. This human cadaveric study aims to assess the DAP’s impact on IRP and the irrigant flow rate compared to a traditional UAS. Methods: Twelve fresh frozen human cadaver renal units were studied in situ. An 11/13 UAS was placed under fluoroscopic guidance and a fURS was introduced. Continuous pressure was monitored. The DAP and syphoning UAS were compared to a conventional irrigation system in terms of IRP and irrigant flow at variable irrigant fluid heights and during fluid bolus administration. Results: The mean IRP was reduced by 79–141%. Maximum IRP was reduced by up to 180%. The mean irrigation flow rate was improved by 44–86%. The small sample size of 12 limits the results obtained. Conclusions: The novel DAP system shows promise in reducing intra-renal pressure and improving irrigant flow in flexible ureteroscopy.

  • Open Access

    The Porcine Model for Urological Research and Training: An Endoscopic and CT-Based Study

    by Jeff John, Graham Fieggen, Lisa Kaestner, John Lazarus

    Background/Objectives: For centuries, humans have employed animal models to progress biomedical science, to understand pathological and biological processes, and to develop and test drugs, vaccines, and surgical techniques. In the field of urology, Sampaio and his colleagues from Brazil were the pioneers in proposing that the porcine model is the most accurate representation of the human kidney. We aim to describe the relevant urinary anatomy of female Landrace pigs based on endoscopy and computed tomography (CT) scans and compare differences between the urinary anatomy of pigs and humans. Methods: Four white Landrace female pigs were used for the study: two for CT imaging and two for endoscopic assessment. CT-urograms were performed using a 64-channel tomography machine with 0.625 mm thick slices. For the endoscopic procedure, the intravaginal urethral meatus was cannulated using a cystoscope, followed by complete urethrocystoscopy. The ureteric orifices were then cannulated, and a retrograde pyelogram was performed, followed by ureterorenoscopy. The analyses were performed using SPSS (Version 28), and simulated data was created using R (version 3.5.0), with the significance set at p ≤ 0.05. The data obtained from two pigs was used to simulate an empirical data with 500 observations, using the mean and standard deviations from our n = 2 to produce a random normal distribution. Results: CT and endoscopic findings showed two multirenculate multipapillate kidneys, each receiving blood supply from a single renal artery that is further divided into cranial and caudal branches. The delayed phase of the urogram showed distal ureters passing posterior to the bladder and emptying into the bladder at the base. Urethroscopy revealed an intravaginal urethral meatus ventral to the anus, positioned midway between the mucocutaneous junction of the vulva and the cervix. Endoscopic view of the bladder neck showing patulous ureteric orifices at the bladder neck with no distinct interureteric ridge or trigone. Retrograde pyelogram showed a Group B drainage pattern in both pigs. Conclusions: While there are numerous similarities between the urinary systems of humans and pigs, there are important subtle differences that urologists and researchers need to be mindful of before using the porcine model for urological research and training.


  • Open Access

    A novel small fragment removal system holds promise to improve stone extraction during lithotripsy

    by John Lazarus, Mark Wellman, Jeff John

    Objective: To describe a novel small fragment removal system (SFRS) which is hypothesized to improve kidney stone fragment removal during laser lithotrypsy. The SFRS consists of three parts: a Syphon Ureteric Access Sheath (SUAS), a Dual Action Pump (DAP) and an Agitator. This clinical trial aims to assess the SFRS’s impact on intra-renal pressure (IRP) and irrigant flow rate compared to a traditional UAS and its stone fragment removal capabilities. Materials and methods: Patients who met the inclusion criteria were enrolled in this prospective single arm seamless Phase 1 and 2 clinical trial. The primary objective of Phase 1 was to evaluate the safety of the SFRS in terms of IRP changes. In Phase 2 we attempted to evaluate the device’s efficacy in removing stone fragments. During standard laser lithotripsy, the DAP and Syphon UAS were compared to a conventional UAS in terms of irrigant flow and IRP at baseline and during fluid bolus administration. Additionally, the percentage of stone fragments removed using the SFRS with the Agitator introduced (in place of the fURS) was assessed. Results: Twelve ( n = 12) patients were enrolled. The SFRS showed lower baseline IRP − 20,8 vs. 24,6mmHg for the traditional UAS ( p = 0,004). During fluid boluses the IRP was lower for the SFRS at 23,5 vs. 75,2mmHg ( p = 0,0002). Greater irrigant flow was seen with the SFRS of 39,2 vs. 34,9mL/min ( p = 0.002). Mean pre-op stone volume was 238mm 3 (range 70–562 mm 3 ), compared to 1,4mm 3 post-op (range 0–8mm 3 ). Conclusions: The novel SFRS holds clinical promise to improve patient safety by reducing IRP with a significant reduction in IRP during fluid bolus administration. It also has the potential to improve visibility via a significant increase in irrigant flow. Lastly, the SFRS was able to remove the overwhelming majority of stone fragments. The main limitation of the study is the small sample size.

  • Open Access

    Novel small fragment removal system may improve extraction of renal calculi: an in vitro study

    by John Lazarus, Mark Wellman, Jørgen Wulfsberg, Tommaso Ceccato, Jeff John

    Objective: To describe a novel Small Fragment Removal System (SFRS) which is hypothesized to improve stone fragment removal during flexible ureteroscopy in patients with urolithiasis. The SFRS consists of three parts: a Syphon Ureteric Access Sheath (SUAS), a Dual Action Pump (DAP) and an Agitator. This bench assessment aims to assess the SFRS’s impact on intra-renal pressure (IRP), irrigant flow rate and stone fragment removal compared to a traditional UAS. Materials and methods: A validated phantom kidney and fibre optic pressure sensor was used to assess IRP. Standardized irrigation via a flexible ureterorenoscope was instilled through a traditional UAS and compared to the novel SFRS. Both were 11/13Fr in size. Measured minute volume, IRP and percentage of stone fragments removed were compared. Results: The mean IRP using a traditional UAS and SFRS was 24,3mmHg and 9,4mmHg respectively. The flow rate of the traditional UAS was 25mL/min, compared to 31mL/min with the SFRS attached. During bolus fluid administration using the traditional UAS the maximum IRP increased to 41mmHg, compared to 9,3mmHg with the SFRS attached. A mean of 42,7% (0,103 g of 0,305 g) of weighed dry stones were removed with the traditional UAS compared to 77,6% (0,233 g of 0,299 g) with the SFRS attached, p = 0,017. Conclusions: The described Small Fragment Removal System (SFRS) is different from traditional UASs by incorporating a syphoning mechanism. In addition, it has a Dual Action Pump which both boluses and augments the aspiration of irrigant by the Syphon. It further includes a deflectable Agitator to flush out stone fragments.


  • Reply to Editorial Comment on “Intrarenal Pressure in RetrogradeIntrarenal Surgery: A Narrative Review”

    by Jeff John, Pawel Wisniewski, Graham Fieggen, Lisa Kaestner, John Lazarus