Cheng-Kuan Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cheng-Kuan Su has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Yuh-Chang Sun
Department of Biomedical Engineering and Environmental Sciences, National Tsing-Hua University, Hsinchu, 30013, Taiwan
21 shared publications Yuh-Chang Sun
5 shared publicationsChun-Yi Wu
Department of Chemistry, National Chung Hsing University, Taichung City, 402, Taiwan, ROC
3 shared publicationsHsiao-Chu Chiu
Department of Chemistry, National Chung Hsing University, Taichung City, 402227, Taiwan, ROC
3 shared publicationsJyun-Ran Chen
Department of Chemistry, National Chung Hsing University, Taichung City, 402, Taiwan, ROC
3 shared publicationsPo-Jen Tseng
Department of Biomedical Engineering and Environmental Sciences, National Tsing-Hua University, Hsinchu, 30013, Taiwan
3 shared publications
Latest Publications
- 9 November 2026
- Published by Springer Nature in Microchimica Acta
- Vol. 193 (12) , 796
4D-printed, NIR-actuated, and power-controlled stream selector for automated solid-phase extraction of multiple trace metals
- 9 November 2026
- Published by Springer Nature in Microchimica Acta
- Vol. 193 (12) , 796
4D-printed, NIR-actuated, and power-controlled stream selector for automated solid-phase extraction of multiple trace metals
- 10 September 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1424, 346250
4D-printed Cd2+-responsive rolling needle panel meter
- 10 September 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1424, 346250
4D-printed Cd2+-responsive rolling needle panel meter
- Open Access
- 26 August 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (39) , 28717-28727
4D-Printed Temperature-Switchable Monolithic Packing for NIR-Actuated Elemental Speciation Analysis
Four-dimensional printing (4DP) technologies drive the use of stimuli-responsive materials in the fabrication of versatile analytical devices. In this study, a monolithic packing comprising a nonresponsive part and a graphene-incorporated thermoresponsive part was fabricated using digital light processing 4DP technique and N-isopropylacrylamide (NIPAM)-based photocurable resins with and without graphene to enable elemental speciation analysis in one solid-phase extraction column. The nonresponsive part selectively extracted Cr(III), As(III), and Se(IV) when its temperature was lower than the volume phase transition temperature (VPTT) of the polyNIPAM hydrogel. The graphene-incorporated part became hydrophobic for the selective extraction of Cr(VI), As(V), and Se(VI) when near-infrared (NIR) irradiation was applied to increase its temperature (>VPTT), resulting in the NIR-actuated switching of monolithic packing’s hydrophobicity for the speciation analysis of inorganic Cr, As, and Se. After optimizing the design, fabrication, and NIR actuation of the monolithic packing, the automated speciation scheme was coupled with inductively coupled plasma mass spectrometry to enable highly sensitive speciation of inorganic Cr, As, and Se; the method detection limits and absolute extraction efficiencies of these species were 0.1–0.6 ng L–1 and >87.3%, respectively. These species were analyzed in reference materials (CASS-6, SLRS-5, 1643f, and Seronorm Trace Elements Urine L-2) and environmental water and human urine samples to validate the reliability of this method. The results indicated that the 4D-printed NIR-actuated temperature-switchable monolithic packing showed promising capability and applicability to advance nonchromatographic speciation analysis of trace elements.
- 26 August 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (39) , 28717-28727
Open Access4D-Printed Temperature-Switchable Monolithic Packing for NIR-Actuated Elemental Speciation Analysis
Four-dimensional printing (4DP) technologies drive the use of stimuli-responsive materials in the fabrication of versatile analytical devices. In this study, a monolithic packing comprising a nonresponsive part and a graphene-incorporated thermoresponsive part was fabricated using digital light processing 4DP technique and N-isopropylacrylamide (NIPAM)-based photocurable resins with and without graphene to enable elemental speciation analysis in one solid-phase extraction column. The nonresponsive part selectively extracted Cr(III), As(III), and Se(IV) when its temperature was lower than the volume phase transition temperature (VPTT) of the polyNIPAM hydrogel. The graphene-incorporated part became hydrophobic for the selective extraction of Cr(VI), As(V), and Se(VI) when near-infrared (NIR) irradiation was applied to increase its temperature (>VPTT), resulting in the NIR-actuated switching of monolithic packing’s hydrophobicity for the speciation analysis of inorganic Cr, As, and Se. After optimizing the design, fabrication, and NIR actuation of the monolithic packing, the automated speciation scheme was coupled with inductively coupled plasma mass spectrometry to enable highly sensitive speciation of inorganic Cr, As, and Se; the method detection limits and absolute extraction efficiencies of these species were 0.1–0.6 ng L–1 and >87.3%, respectively. These species were analyzed in reference materials (CASS-6, SLRS-5, 1643f, and Seronorm Trace Elements Urine L-2) and environmental water and human urine samples to validate the reliability of this method. The results indicated that the 4D-printed NIR-actuated temperature-switchable monolithic packing showed promising capability and applicability to advance nonchromatographic speciation analysis of trace elements.
- 22 January 2026
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 298, 118437
4D-printed ELISA needle panel meter
- 22 January 2026
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 298, 118437
4D-printed ELISA needle panel meter
- Open Access
- 24 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (29) , 15642-15650
4D-Printed Redox-Responsive Needle-Flow Reactors Enabling Online Quantitative Profiling of Living Rat Brain Extracellular Lactate and Glucose
Various assays are performed based on the use of oxidase-based derivatization schemes coupled with chromogenic or fluorogenic reagents and spectrometric determination. To enable online quantitative profiling of living rat brain extracellular glucose and lactate without requiring a spectrophotometer or fluorometer, a flow reactor with a redox-responsive needle is fabricated using the digital light processing four-dimensional printing (4DP) technique and photocurable resins incorporating 2,2'-(ethylenedioxy)diethanethiol (EDT). Upon exposure to hydrogen peroxide (H2O2), oxidation of the thioether groups of the copolymer increases the polarity and swelling of the EDT-incorporated layer, inducing [H2O2]-dependent bending of the needle. Coupling this device with glucose- and lactate-oxidase-mediated reactions facilitates the reliable determination of glucose and lactate. Furthermore, the needle returns to its original state after treatment with a sodium borohydride solution, demonstrating the reversible, redox-responsive shape programming for repeated measurements. Integration of the microdialysis sampling apparatus, oxidase-based derivatization schemes, and 4D-printed redox-responsive needle-flow reactors into an online automatic analytical system achieves the method's detection limits of 0.3 μM for glucose and 0.4 μM for lactate. To verify the reliability and applicability of this method, we perform analyses of human urine and sweat, fetal bovine serum, and rat plasma with their spike analyses, compare the results with those obtained from assay kits, and profile living rat brain extracellular glucose and lactate levels with triggered neuronal depolarization. The findings demonstrate that 4DP technologies enable the efficient fabrication of redox-responsive analytical devices and enhance the applicability of conventional enzymatic assays for online quantitative chemical analysis.
- 24 June 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (29) , 15642-15650
Open Access4D-Printed Redox-Responsive Needle-Flow Reactors Enabling Online Quantitative Profiling of Living Rat Brain Extracellular Lactate and Glucose
Various assays are performed based on the use of oxidase-based derivatization schemes coupled with chromogenic or fluorogenic reagents and spectrometric determination. To enable online quantitative profiling of living rat brain extracellular glucose and lactate without requiring a spectrophotometer or fluorometer, a flow reactor with a redox-responsive needle is fabricated using the digital light processing four-dimensional printing (4DP) technique and photocurable resins incorporating 2,2'-(ethylenedioxy)diethanethiol (EDT). Upon exposure to hydrogen peroxide (H2O2), oxidation of the thioether groups of the copolymer increases the polarity and swelling of the EDT-incorporated layer, inducing [H2O2]-dependent bending of the needle. Coupling this device with glucose- and lactate-oxidase-mediated reactions facilitates the reliable determination of glucose and lactate. Furthermore, the needle returns to its original state after treatment with a sodium borohydride solution, demonstrating the reversible, redox-responsive shape programming for repeated measurements. Integration of the microdialysis sampling apparatus, oxidase-based derivatization schemes, and 4D-printed redox-responsive needle-flow reactors into an online automatic analytical system achieves the method's detection limits of 0.3 μM for glucose and 0.4 μM for lactate. To verify the reliability and applicability of this method, we perform analyses of human urine and sweat, fetal bovine serum, and rat plasma with their spike analyses, compare the results with those obtained from assay kits, and profile living rat brain extracellular glucose and lactate levels with triggered neuronal depolarization. The findings demonstrate that 4DP technologies enable the efficient fabrication of redox-responsive analytical devices and enhance the applicability of conventional enzymatic assays for online quantitative chemical analysis.
- Open Access
- 25 December 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (2) , 1281-1290
Fully 4D-Printed Near-Infrared-Actuated Lab-on-Valve Solid-Phase Extraction Devices
Four-dimensional printing (4DP) technologies can expand the functionality of stimuli-responsive devices to enable the integration of multiple stimuli-responsive parts into a compact device. Herein, we used digital light processing three-dimensional printing technique, flexible photocurable resins, and photocurable resins of the temperature-responsive hydrogels comprising N-isopropylacrylamide (NIPAM), N,N'-methylenebis(acrylamide) (MBA), and graphene for 4DP of a lab-on-valve (LOV) solid-phase extraction (SPE) device. This device featured flow manifolds and a monolithic packing connected by four near-infrared (NIR)-actuated temperature-responsive switching valves composed of a poly(NIPAM/MBA) (PNM) ball pushing a flexible membrane. NIR irradiation caused the deswelling of the PNM ball [temperature > volume phase transition temperature (VPTT) of the hydrogel], and the valve was opened to switch the flow direction. The termination of this irradiation caused the swelling of the PNM ball (temperature < VPTT of the hydrogel) to close the valve and thus recover the original flow direction to achieve the automatic NIR-actuated fluid control. The optimized 4D-printed NIR-actuated LOV-SPE device enabled a fully automatic SPE scheme coupled with inductively coupled plasma mass spectrometry for the determination of Mn, Co, Ni, Cu, Zn, Cd, and Pb ions (detection limits = 0.1,6.8 ng L-1). The reliability of this analytical method was validated by determining the metal ions in the four reference materials (CASS-6, SLRS-5, 1643f, and Trace Elements Urine L-2) and environmental water and human urine samples. Our results demonstrated the capability and applicability of 4DP technologies for advancing the automation of LOV-SPE schemes and related analytical methods.
- 25 December 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (2) , 1281-1290
Open AccessFully 4D-Printed Near-Infrared-Actuated Lab-on-Valve Solid-Phase Extraction Devices
Four-dimensional printing (4DP) technologies can expand the functionality of stimuli-responsive devices to enable the integration of multiple stimuli-responsive parts into a compact device. Herein, we used digital light processing three-dimensional printing technique, flexible photocurable resins, and photocurable resins of the temperature-responsive hydrogels comprising N-isopropylacrylamide (NIPAM), N,N'-methylenebis(acrylamide) (MBA), and graphene for 4DP of a lab-on-valve (LOV) solid-phase extraction (SPE) device. This device featured flow manifolds and a monolithic packing connected by four near-infrared (NIR)-actuated temperature-responsive switching valves composed of a poly(NIPAM/MBA) (PNM) ball pushing a flexible membrane. NIR irradiation caused the deswelling of the PNM ball [temperature > volume phase transition temperature (VPTT) of the hydrogel], and the valve was opened to switch the flow direction. The termination of this irradiation caused the swelling of the PNM ball (temperature < VPTT of the hydrogel) to close the valve and thus recover the original flow direction to achieve the automatic NIR-actuated fluid control. The optimized 4D-printed NIR-actuated LOV-SPE device enabled a fully automatic SPE scheme coupled with inductively coupled plasma mass spectrometry for the determination of Mn, Co, Ni, Cu, Zn, Cd, and Pb ions (detection limits = 0.1,6.8 ng L-1). The reliability of this analytical method was validated by determining the metal ions in the four reference materials (CASS-6, SLRS-5, 1643f, and Trace Elements Urine L-2) and environmental water and human urine samples. Our results demonstrated the capability and applicability of 4DP technologies for advancing the automation of LOV-SPE schemes and related analytical methods.
- 8 December 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1336, 343536
4D-printed programmable sample-/eluent-actuated solid-phase extraction device for trace metal analysis
- 8 December 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1336, 343536
4D-printed programmable sample-/eluent-actuated solid-phase extraction device for trace metal analysis
- 13 September 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (10) , 1-11
3D-printed thermally expanded monolithic foam for solid-phase extraction of multiple trace metals
Digital light processing (DLP) 3DP, commercial acrylate-based photocurable resins, and thermally expandable microspheres-incorporated flexible photocurable resins were employed to fabricate an SPE column with a thermally expanded monolithic foam for extracting Mn, Co, Ni, Cu, Zn, Cd, and Pb ions prior to the determination using inductively coupled plasma mass spectrometry. After optimization of the thermally activated foaming, the design and fabrication of the SPE column, and the automatic analytical system, the DLP 3D-printed SPE column with the thermally expanded monolithic foam extracted the metal ions with up to 14.8-fold enhancement (relative to that without incorporating the microspheres), with absolute extraction efficiencies all higher than 95.6%, and method detection limits in the range from 0.5 to 5.2 ng L–1. We validated the reliability and applicability of this method by determination of the metal ions in several reference materials (CASS-4, SLRS-5, 1643f, and Seronorm Trace Elements Urine L-2) and spiked seawater, river water, ground water, and human urine samples. The results illustrated that to incorporate the thermally expandable microspheres into the photocurable resins with a post-printing heating treatment enabled the DLP 3D-printed thermally expanded monolithic foam to substantially improve the extraction of the metal ions, thereby extending the applicability of SPE devices fabricated by vat photopolymerization 3DP techniques. Graphical abstract
- 13 September 2024
- Published by Springer Nature in Microchimica Acta
- Vol. 191 (10) , 1-11
3D-printed thermally expanded monolithic foam for solid-phase extraction of multiple trace metals
Digital light processing (DLP) 3DP, commercial acrylate-based photocurable resins, and thermally expandable microspheres-incorporated flexible photocurable resins were employed to fabricate an SPE column with a thermally expanded monolithic foam for extracting Mn, Co, Ni, Cu, Zn, Cd, and Pb ions prior to the determination using inductively coupled plasma mass spectrometry. After optimization of the thermally activated foaming, the design and fabrication of the SPE column, and the automatic analytical system, the DLP 3D-printed SPE column with the thermally expanded monolithic foam extracted the metal ions with up to 14.8-fold enhancement (relative to that without incorporating the microspheres), with absolute extraction efficiencies all higher than 95.6%, and method detection limits in the range from 0.5 to 5.2 ng L–1. We validated the reliability and applicability of this method by determination of the metal ions in several reference materials (CASS-4, SLRS-5, 1643f, and Seronorm Trace Elements Urine L-2) and spiked seawater, river water, ground water, and human urine samples. The results illustrated that to incorporate the thermally expandable microspheres into the photocurable resins with a post-printing heating treatment enabled the DLP 3D-printed thermally expanded monolithic foam to substantially improve the extraction of the metal ions, thereby extending the applicability of SPE devices fabricated by vat photopolymerization 3DP techniques. Graphical abstract