Han Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Han Zhang has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
- Daisuke Fujita
National Institute for Materials Science
5 shared publications Hongxin Wang
National Institute for Materials Science
5 shared publications- Koji Kimoto
National Institute for Materials Science
4 shared publications - Ikumu Watanabe
National Institute for Materials Science
3 shared publications Akihiro Ikeda
JEOL Ltd, Akishima, Japan
2 shared publicationsAkira Niwata
JEOL Ltd, Akishima, Japan
2 shared publications
Latest Publications
- Open Access
- 2 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (13)
Characterizing the effects of temperature on the thermal vibration properties of individual nanowires
We study the effects of temperature on the properties of thermal vibrations of individual LaB6 single-crystal nanowires inside a transmission electron microscope using a method which combines high spatial resolution, high temporal resolution, and in situ temperature control. We find that the vibrations can be accurately modeled by classical formalisms, despite the small size of the resonator. We observe a vibration frequency decrease with temperature which enables us to measure the temperature coefficient of Young's modulus, finding a value of αE≅−9×10−5K−1 over the 300–700 K temperature range. We additionally introduce a method to precisely measure the vibration amplitude, which agrees well with values predicted by the Boltzmann equipartition theorem over the entire temperature range.
- 2 October 2025
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 138 (13)
Open AccessCharacterizing the effects of temperature on the thermal vibration properties of individual nanowires
We study the effects of temperature on the properties of thermal vibrations of individual LaB6 single-crystal nanowires inside a transmission electron microscope using a method which combines high spatial resolution, high temporal resolution, and in situ temperature control. We find that the vibrations can be accurately modeled by classical formalisms, despite the small size of the resonator. We observe a vibration frequency decrease with temperature which enables us to measure the temperature coefficient of Young's modulus, finding a value of αE≅−9×10−5K−1 over the 300–700 K temperature range. We additionally introduce a method to precisely measure the vibration amplitude, which agrees well with values predicted by the Boltzmann equipartition theorem over the entire temperature range.
- Open Access
- 18 October 2023
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 24 (1) , 2265434
Mapping stress inside living cells by atomic force microscopy in response to environmental stimuli
The response of cells to environmental stimuli, under either physiological or pathological conditions, plays a key role in determining cell fate toward either adaptive survival or controlled death. The efficiency of such a feedback mechanism is closely related to the most challenging human diseases, including cancer. Since cellular responses are implemented through physical forces exerted on intracellular components, more detailed knowledge of force distribution through modern imaging techniques is needed to ensure a mechanistic understanding of these forces. In this work, we mapped these intracellular forces at a whole-cell scale and with submicron resolution to correlate intracellular force distribution to the cytoskeletal structures. Furthermore, we visualized dynamic mechanical responses of the cells adapting to environmental modulations in situ. Such task was achieved by using an informatics-assisted atomic force microscope (AFM) indentation technique where a key step was Markov-chain Monte Carlo optimization to search for both the models used to fit indentation force–displacement curves and probe geometry descriptors. We demonstrated force dynamics within cytoskeleton, as well as nucleoskeleton in living cells which were subjected to mechanical state modulation: myosin motor inhibition, micro-compression stimulation and geometrical confinement manipulation. Our results highlight the alteration in the intracellular prestress to attenuate environmental stimuli; to involve in cellular survival against mechanical signal-initiated death during cancer growth and metastasis; and to initiate cell migration.
- 18 October 2023
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 24 (1) , 2265434
Open AccessMapping stress inside living cells by atomic force microscopy in response to environmental stimuli
The response of cells to environmental stimuli, under either physiological or pathological conditions, plays a key role in determining cell fate toward either adaptive survival or controlled death. The efficiency of such a feedback mechanism is closely related to the most challenging human diseases, including cancer. Since cellular responses are implemented through physical forces exerted on intracellular components, more detailed knowledge of force distribution through modern imaging techniques is needed to ensure a mechanistic understanding of these forces. In this work, we mapped these intracellular forces at a whole-cell scale and with submicron resolution to correlate intracellular force distribution to the cytoskeletal structures. Furthermore, we visualized dynamic mechanical responses of the cells adapting to environmental modulations in situ. Such task was achieved by using an informatics-assisted atomic force microscope (AFM) indentation technique where a key step was Markov-chain Monte Carlo optimization to search for both the models used to fit indentation force–displacement curves and probe geometry descriptors. We demonstrated force dynamics within cytoskeleton, as well as nucleoskeleton in living cells which were subjected to mechanical state modulation: myosin motor inhibition, micro-compression stimulation and geometrical confinement manipulation. Our results highlight the alteration in the intracellular prestress to attenuate environmental stimuli; to involve in cellular survival against mechanical signal-initiated death during cancer growth and metastasis; and to initiate cell migration.
- 9 December 2022
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 22 (24) , 10034-10039
Direct Observation of Thermal Vibration Modes Using Frequency-Selective Electron Microscopy
Thermal vibration properties of nanometer-scale objects are critical for their application in devices such as nanomechanical resonators. An imaging method has been developed which allows the direct visualization of higher-order thermal vibration modes at room temperature, which have so far been inaccessible to observation due to their subangstrom amplitudes and the much stronger overlapped first mode. This technique, combining aberration-corrected scanning transmission electron microscopy with broad-band signal acquisition in the time domain, can display the amplitude distribution of several thermal vibration modes simultaneously by selecting specific frequency windows. This is showcased by mapping the first six thermal vibration modes of a singly clamped nanowire and comparing them to natural vibration mode profiles obtained by finite element calculations. This implementation furthers our understanding of the collective Brownian motion of nanostructures and extends the analysis capabilities of electron microscopy.
- 9 December 2022
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 22 (24) , 10034-10039
Direct Observation of Thermal Vibration Modes Using Frequency-Selective Electron Microscopy
Thermal vibration properties of nanometer-scale objects are critical for their application in devices such as nanomechanical resonators. An imaging method has been developed which allows the direct visualization of higher-order thermal vibration modes at room temperature, which have so far been inaccessible to observation due to their subangstrom amplitudes and the much stronger overlapped first mode. This technique, combining aberration-corrected scanning transmission electron microscopy with broad-band signal acquisition in the time domain, can display the amplitude distribution of several thermal vibration modes simultaneously by selecting specific frequency windows. This is showcased by mapping the first six thermal vibration modes of a singly clamped nanowire and comparing them to natural vibration mode profiles obtained by finite element calculations. This implementation furthers our understanding of the collective Brownian motion of nanostructures and extends the analysis capabilities of electron microscopy.
- 8 November 2021
- Published by Springer Nature in Nature Nanotechnology
- Vol. 17 (1) , 21-26
High-endurance micro-engineered LaB6 nanowire electron source for high-resolution electron microscopy
The size tunability and chemical versatility of nanostructures enable electron sources of high brightness and temporal coherence, both of which are important characteristics for high-resolution electron microscopy1,2,3. Despite intensive research efforts in the field, so far, only conventional field emitters based on a bulk tungsten (W) needle have been able to yield atomic-resolution images. The absence of viable alternatives is in part caused by insufficient fabrication precision for nanostructured sources, which require an alignment precision of subdegree angular deviation of a nanometre-sized emission area with the macroscopic emitter axis4. To overcome this challenge, in this work we micro-engineered a LaB6 nanowire-based electron source that emitted a highly collimated electron beam with good lateral and angular alignment. We integrated a passive collimator structure into the support needle tip for the LaB6 nanowire emitter. The collimator formed an axially symmetric electric field around the emission tip of the nanowire. Furthermore, by means of micromanipulation, the support needle tip was bent to align the emitted electron beam with the emitter axis. After installation in an aberration-corrected transmission electron microscope, we characterized the performance of the electron source in a vacuum of 10−8 Pa and achieved atomic resolution in both broad-beam and probe-forming modes at 60 kV beam energy. The natural, unmonochromated 0.20 eV electron energy loss spectroscopy resolution, 20% probe-forming efficiency and 0.4% probe current peak-to-peak noise ratio paired with modest vacuum requirements make the LaB6 nanowire-based electron source an attractive alternative to the standard W-based sources for low-cost electron beam instruments.
- 8 November 2021
- Published by Springer Nature in Nature Nanotechnology
- Vol. 17 (1) , 21-26
High-endurance micro-engineered LaB6 nanowire electron source for high-resolution electron microscopy
The size tunability and chemical versatility of nanostructures enable electron sources of high brightness and temporal coherence, both of which are important characteristics for high-resolution electron microscopy1,2,3. Despite intensive research efforts in the field, so far, only conventional field emitters based on a bulk tungsten (W) needle have been able to yield atomic-resolution images. The absence of viable alternatives is in part caused by insufficient fabrication precision for nanostructured sources, which require an alignment precision of subdegree angular deviation of a nanometre-sized emission area with the macroscopic emitter axis4. To overcome this challenge, in this work we micro-engineered a LaB6 nanowire-based electron source that emitted a highly collimated electron beam with good lateral and angular alignment. We integrated a passive collimator structure into the support needle tip for the LaB6 nanowire emitter. The collimator formed an axially symmetric electric field around the emission tip of the nanowire. Furthermore, by means of micromanipulation, the support needle tip was bent to align the emitted electron beam with the emitter axis. After installation in an aberration-corrected transmission electron microscope, we characterized the performance of the electron source in a vacuum of 10−8 Pa and achieved atomic resolution in both broad-beam and probe-forming modes at 60 kV beam energy. The natural, unmonochromated 0.20 eV electron energy loss spectroscopy resolution, 20% probe-forming efficiency and 0.4% probe current peak-to-peak noise ratio paired with modest vacuum requirements make the LaB6 nanowire-based electron source an attractive alternative to the standard W-based sources for low-cost electron beam instruments.
- 5 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Photoemission from an ultrabright and ultrafast LaB6 nanowire electron emitter studied at atomic scale
Lanthanum hexaboride (LaB 6 ) nanowire emitters have been demonstrated to work as monochromatic ultrabright field emitters. A small atomic array consisting of only a few La atoms at the foremost (100) facet generates a stark contrast of the surrounding work function. With the help of femtosecond laser pulses, we will show that this special surface morphology is also directly reflected in the photoemission as a function of wavelength. By comparing the measured total absorption energy with the density of states (DOS), emission channels with different initial and final states are revealed to explain the observed results. Moreover, an electron biprism interference measurement is performed, showing excellent transverse beam quality with a normalized emittance of ε n = 1.41 pm rad and a normalized peak brightness of B n,p = 9 × 10 13 A/(m 2 sr). These results show that LaB 6 nanowire emitters are ultrafast and ultrabright, which could benefit novel applications like dielectric laser acceleration (DLA) and ultrafast electron diffraction (UED).
- 5 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Photoemission from an ultrabright and ultrafast LaB6 nanowire electron emitter studied at atomic scale
Lanthanum hexaboride (LaB 6 ) nanowire emitters have been demonstrated to work as monochromatic ultrabright field emitters. A small atomic array consisting of only a few La atoms at the foremost (100) facet generates a stark contrast of the surrounding work function. With the help of femtosecond laser pulses, we will show that this special surface morphology is also directly reflected in the photoemission as a function of wavelength. By comparing the measured total absorption energy with the density of states (DOS), emission channels with different initial and final states are revealed to explain the observed results. Moreover, an electron biprism interference measurement is performed, showing excellent transverse beam quality with a normalized emittance of ε n = 1.41 pm rad and a normalized peak brightness of B n,p = 9 × 10 13 A/(m 2 sr). These results show that LaB 6 nanowire emitters are ultrafast and ultrabright, which could benefit novel applications like dielectric laser acceleration (DLA) and ultrafast electron diffraction (UED).
- Open Access
- 26 April 2021
- Published by Springer Nature in Research Square
Micro-engineered Nanowire Electron Source for Atomic Resolution Imaging
The size tunability and chemical versatility of nanostructures provide attractive engineering potential to realize an electron source of high brightness and spatial temporal coherence, which is a characteristic ever pursued by high resolution electron microscopy. (1–3) Regardless of the intensive research efforts, electron sources that have ever produced atomic resolution images are still limited to the conventional field emitters based on a bulk W needle. It is due to the lack of fabrication precision for nanostructured sources, that is required to align a nanometric emission volume along a macroscopic emitter axis with sub-degree angular deviation. (4) In this work, we produced a LaB6 nanowire electron source which was micro-engineered to ensure a highly collimated electron beam with perfect lateral and angular alignment. Such electron source was validated by installing in an aberration-corrected transmission electron microscope, where atomic resolution in both broad-beam and probe-forming modes were demonstrated at 60kV beam energy. The recorded un-monochromated 0.20eV electron energy loss spectroscopy (EELS) resolution, together with 20% probe forming efficiency and 0.4% probe current peak-to-peak noise ratio under a wide vacuum range, presented the unique advantages of nanotechnology and promised high performance low-cost electron beam instruments.
- 26 April 2021
- Published by Springer Nature in Research Square
Open AccessMicro-engineered Nanowire Electron Source for Atomic Resolution Imaging
The size tunability and chemical versatility of nanostructures provide attractive engineering potential to realize an electron source of high brightness and spatial temporal coherence, which is a characteristic ever pursued by high resolution electron microscopy. (1–3) Regardless of the intensive research efforts, electron sources that have ever produced atomic resolution images are still limited to the conventional field emitters based on a bulk W needle. It is due to the lack of fabrication precision for nanostructured sources, that is required to align a nanometric emission volume along a macroscopic emitter axis with sub-degree angular deviation. (4) In this work, we produced a LaB6 nanowire electron source which was micro-engineered to ensure a highly collimated electron beam with perfect lateral and angular alignment. Such electron source was validated by installing in an aberration-corrected transmission electron microscope, where atomic resolution in both broad-beam and probe-forming modes were demonstrated at 60kV beam energy. The recorded un-monochromated 0.20eV electron energy loss spectroscopy (EELS) resolution, together with 20% probe forming efficiency and 0.4% probe current peak-to-peak noise ratio under a wide vacuum range, presented the unique advantages of nanotechnology and promised high performance low-cost electron beam instruments.
- 21 January 2021
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 21 (3) , 1538-1545
Mechanomics Biomarker for Cancer Cells Unidentifiable through Morphology and Elastic Modulus
Cellular mechanical properties are potential cancer biomarkers used for objective cytology to replace the current subjective method relying on cytomorphology. However, heterogeneity among intra/intercellular mechanics and the interplay between cytoskeletal prestress and elastic modulus obscured the difference detectable between malignant and benign cells. In this work, we collected high density nanoscale prestress and elastic modulus data from a single cell by AFM indentation to generate a cellular mechanome. Such high dimensional mechanome data was used to train a malignancy classifier through machine learning. The classifier was tested on 340 single cells of various origins, malignancy, and degrees of similarity in morphology and elastic modulus. The classifier showed instrument-independent robustness and classification accuracy of 89% with an AUC-ROC value of 93%. A signal-to-noise ratio 8 times that of the human-cytologist-based morphological method was also demonstrated, in differentiating precancerous hyperplasia cells from normal cells derived from the same lung cancer patient.
- 21 January 2021
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 21 (3) , 1538-1545
Mechanomics Biomarker for Cancer Cells Unidentifiable through Morphology and Elastic Modulus
Cellular mechanical properties are potential cancer biomarkers used for objective cytology to replace the current subjective method relying on cytomorphology. However, heterogeneity among intra/intercellular mechanics and the interplay between cytoskeletal prestress and elastic modulus obscured the difference detectable between malignant and benign cells. In this work, we collected high density nanoscale prestress and elastic modulus data from a single cell by AFM indentation to generate a cellular mechanome. Such high dimensional mechanome data was used to train a malignancy classifier through machine learning. The classifier was tested on 340 single cells of various origins, malignancy, and degrees of similarity in morphology and elastic modulus. The classifier showed instrument-independent robustness and classification accuracy of 89% with an AUC-ROC value of 93%. A signal-to-noise ratio 8 times that of the human-cytologist-based morphological method was also demonstrated, in differentiating precancerous hyperplasia cells from normal cells derived from the same lung cancer patient.
- Open Access
- 31 January 2020
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 21 (1) , 267-277
Stress mapping reveals extrinsic toughening of brittle carbon fiber in polymer matrix
We conducted an in situ study on CFRP fracturing process using atomic-force-microscopy-based stress-sensitive indentation. Tensile stress distribution during fracture initiation and propagation was directly observed quantitatively. It led to a discovery that previously believed catastrophic fracture of individual carbon fiber develops in a controllable manner in the polymer matrix, exhibiting 10 times increase of fracture toughness. Plastic deformation in crack-bridging polymer matrix was accounted for the toughening mechanism. The model was applied to explain low temperature strength weakening of CFRP bulk material when matrix plasticity was intentionally ‘shut down’ by cryogenic cooling. Graphical abstract
- 31 January 2020
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 21 (1) , 267-277
Open AccessStress mapping reveals extrinsic toughening of brittle carbon fiber in polymer matrix
We conducted an in situ study on CFRP fracturing process using atomic-force-microscopy-based stress-sensitive indentation. Tensile stress distribution during fracture initiation and propagation was directly observed quantitatively. It led to a discovery that previously believed catastrophic fracture of individual carbon fiber develops in a controllable manner in the polymer matrix, exhibiting 10 times increase of fracture toughness. Plastic deformation in crack-bridging polymer matrix was accounted for the toughening mechanism. The model was applied to explain low temperature strength weakening of CFRP bulk material when matrix plasticity was intentionally ‘shut down’ by cryogenic cooling. Graphical abstract
- Open Access
- 28 March 2019
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 20 (1) , 412-420
Stress dependence of indentation modulus for carbon fiber in polymer composite
Elastic modulus measured through atomic force microscopy (AFM)-based indentation on single carbon fiber (CF) is found with dependence on lateral applied stress. An in situ indentation experiment inside a high-resolution transmission electron microscope was performed to quantitatively understand this phenomenon by observing microstructure change in the indented area. Change of graphitic basal plane misalignment angle during indentation was linked to a continuous change of modulus with the help of finite element simulation. The established relationship between modulus and indentation force was further used to calculate residual stress distribution in CF imbedded in a CF reinforced polymer composite using the AFM indentation technique. The stress-induced formation of nanoscale defects in the CF and their transformation into fracture were directly characterized. GRAPHICAL ABSTRACT
- 28 March 2019
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 20 (1) , 412-420
Open AccessStress dependence of indentation modulus for carbon fiber in polymer composite
Elastic modulus measured through atomic force microscopy (AFM)-based indentation on single carbon fiber (CF) is found with dependence on lateral applied stress. An in situ indentation experiment inside a high-resolution transmission electron microscope was performed to quantitatively understand this phenomenon by observing microstructure change in the indented area. Change of graphitic basal plane misalignment angle during indentation was linked to a continuous change of modulus with the help of finite element simulation. The established relationship between modulus and indentation force was further used to calculate residual stress distribution in CF imbedded in a CF reinforced polymer composite using the AFM indentation technique. The stress-induced formation of nanoscale defects in the CF and their transformation into fracture were directly characterized. GRAPHICAL ABSTRACT
- 14 March 2018
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 122 (13) , 7187-7193
Informatics-Aided Raman Microscopy for Nanometric 3D Stress Characterization
- 14 March 2018
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 122 (13) , 7187-7193
Informatics-Aided Raman Microscopy for Nanometric 3D Stress Characterization