Everlyne A. Songa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Everlyne A. Songa has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Emmanuel Iheanyichukwu Iwuoha
SensorLab (University of the Western Cape Sensor Laboratories) 4th Floor Chemical Sciences Building University of the Western Cape Bellville Cape Town South Africa
6 shared publications - Priscilla Gloria Lorraine Baker
SensorLab research group, Department of Chemistry, University of the Western Cape
6 shared publications - Nazeem Jahed
University of the Western Cape
5 shared publications - Omotayo Ademola Arotiba
Department of Chemical Sciences University of Johannesburg Johannesburg South Africa
3 shared publications Joseph H.O. Owino
2 shared publicationsTesfaye Waryo
SensorLab, University of the Western Cape, Private Bag X 17, Bellville, 7535, South Africa
2 shared publications
Latest Publications
- 28 May 2019
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 99 (11) , 1017-1068
Recent advances in sorbents applications and techniques used for solid-phase extraction of atrazine and its metabolites deisopropylatrazine and deethylatrazine: a review
SPE is the most widely used technique for extraction, clean-up, and pre-concentration of various samples since sample preparation is a crucial step in the analytical process. SPE has been used to pre-concentrate atrazine (ATZ) and its metabolites from different sample matrices at extremely low levels. ATZ is a herbicide for destroying weeds in plants; however, ATZ and its metabolites are toxic above permitted concentrations of 3 ppb. The objective of this review is to provide a summary of recent advances, applications and techniques of SPE sorbents in sample preparation used for extracting ATZ and its primary metabolites prior to chromatographic analysis. The sorbents considered include silica-based sorbents, activated carbon (AC), nanostructured materials (NMs), graphitised carbon black (GCB), molecularly-imprinted polymers (MIP) and polymer sorbents (PS) focusing on SPE. The efficiency of sorbents is demonstrated in terms of recoveries achieved and lowest detection limit (LOD). Of late, research interest in the production of AC has been focused on agricultural residues. Agricultural sorbents derived from agricultural wastes have demonstrated outstanding abilities for the removal of ATZ though there is very limited application of them for SPE. These sorbents are seen as alternatives to known commercial sorbent for remediation of ATZ. Therefore, future prospects are proposed to improve development of new SPE sorbents that are based on affordability, selectivity and efficiency.
- 28 May 2019
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 99 (11) , 1017-1068
Recent advances in sorbents applications and techniques used for solid-phase extraction of atrazine and its metabolites deisopropylatrazine and deethylatrazine: a review
SPE is the most widely used technique for extraction, clean-up, and pre-concentration of various samples since sample preparation is a crucial step in the analytical process. SPE has been used to pre-concentrate atrazine (ATZ) and its metabolites from different sample matrices at extremely low levels. ATZ is a herbicide for destroying weeds in plants; however, ATZ and its metabolites are toxic above permitted concentrations of 3 ppb. The objective of this review is to provide a summary of recent advances, applications and techniques of SPE sorbents in sample preparation used for extracting ATZ and its primary metabolites prior to chromatographic analysis. The sorbents considered include silica-based sorbents, activated carbon (AC), nanostructured materials (NMs), graphitised carbon black (GCB), molecularly-imprinted polymers (MIP) and polymer sorbents (PS) focusing on SPE. The efficiency of sorbents is demonstrated in terms of recoveries achieved and lowest detection limit (LOD). Of late, research interest in the production of AC has been focused on agricultural residues. Agricultural sorbents derived from agricultural wastes have demonstrated outstanding abilities for the removal of ATZ though there is very limited application of them for SPE. These sorbents are seen as alternatives to known commercial sorbent for remediation of ATZ. Therefore, future prospects are proposed to improve development of new SPE sorbents that are based on affordability, selectivity and efficiency.
- Top Cited Papers
Recent approaches to improving selectivity and sensitivity of enzyme-based biosensors for organophosphorus pesticides: A review
- 1 July 2011
- Published by Taylor & Francis in Analytical Letters
- Vol. 44 (11) , 2031-2046
Determination of Selected Heavy Metals Using Amperometric Horseradish Peroxidase (HRP) Inhibition Biosensor
Fabrication of an amperometric biosensor for determination of heavy metals in tap water based on the inhibition of horseradish peroxidase activity is reported. The inhibition of the biosensor's response to 0.95 mM H2O2 at −200 mV (vs. Ag/AgCl) followed the order, Cd2+ < Cu2+ < Pb2+. The detection limits were 0.09 ppb, 0.03 ppb, and 0.10 ppb for Cd2+, Pb2+, and Cu2+, respectively. Kinetic parameters (apparent Michaelis-Menten constant) and Imax (maximum current) obtained in the absence ( = 1.16 mM, Imax = 0.51 µA) and the presence ( = 1.13 mM, Imax = 0.36) of 3.13 ppm Cd2+ showed that the enzyme inhibition process was reversible and non-competitive, and the corresponding KI (inhibition constant) value was 0.026 mM. After two weeks, the biosensor retained >95% of its initial response and gave a reproducibility of 3.8% and precision of 2.1%.
- 1 July 2011
- Published by Taylor & Francis in Analytical Letters
- Vol. 44 (11) , 2031-2046
Determination of Selected Heavy Metals Using Amperometric Horseradish Peroxidase (HRP) Inhibition Biosensor
Fabrication of an amperometric biosensor for determination of heavy metals in tap water based on the inhibition of horseradish peroxidase activity is reported. The inhibition of the biosensor's response to 0.95 mM H2O2 at −200 mV (vs. Ag/AgCl) followed the order, Cd2+ < Cu2+ < Pb2+. The detection limits were 0.09 ppb, 0.03 ppb, and 0.10 ppb for Cd2+, Pb2+, and Cu2+, respectively. Kinetic parameters (apparent Michaelis-Menten constant) and Imax (maximum current) obtained in the absence ( = 1.16 mM, Imax = 0.51 µA) and the presence ( = 1.13 mM, Imax = 0.36) of 3.13 ppm Cd2+ showed that the enzyme inhibition process was reversible and non-competitive, and the corresponding KI (inhibition constant) value was 0.026 mM. After two weeks, the biosensor retained >95% of its initial response and gave a reproducibility of 3.8% and precision of 2.1%.
- 1 June 2009
- Published by Elsevier in Bioelectrochemistry
- Vol. 75 (2) , 117-123
Electrochemical detection of glyphosate herbicide using horseradish peroxidase immobilized on sulfonated polymer matrix
- 1 June 2009
- Published by Elsevier in Bioelectrochemistry
- Vol. 75 (2) , 117-123
Electrochemical detection of glyphosate herbicide using horseradish peroxidase immobilized on sulfonated polymer matrix
- 12 February 2009
- Published by Wiley in Electroanalysis
- Vol. 21 (3-5) , 671-674
Electrochemical Nanobiosensor for Glyphosate Herbicide and Its Metabolite
- 12 February 2009
- Published by Wiley in Electroanalysis
- Vol. 21 (3-5) , 671-674
Electrochemical Nanobiosensor for Glyphosate Herbicide and Its Metabolite
- 1 January 2009
- Published by Walter de Gruyter GmbH in Pure and Applied Chemistry
- Vol. 81 (1) , 123-139
Amperometric nanobiosensor for quantitative determination of glyphosate and glufosinate residues in corn samples
This study presents a simple, sensitive, rapid, and low-cost amperometric method for direct and quantitative determination of glyphosate and glufosinate herbicides. Electrochemical synthesis and characterization of poly(2,5-dimethoxyaniline)-poly(4-styrenesulfonic acid) (PDMA-PSS) nanoparticles was achieved by cyclic voltammetry (CV) and scanning electron microscopy (SEM). The nanobiosensor was constructed by immobilizing the enzyme horseradish peroxidase (HRP) electrostatically onto the surface of a rotating gold disk electrode modified with PDMA-PSS nanoparticles. The biosensing principle was based on determination of the sensor response to glyphosate and glufosinate by amperometric methods. Hydrogen peroxide (H2O2) was used to measure activity of the enzyme before injection of the herbicides into the electrolyte solution. The enzyme electrode was stable for a long period of time and was used for over 60 measurements. Glyphosate and glufosinate analyses were realized on spiked corn samples within a concentration range of 2.0-78.0 μg L-1, corroborating that the nanobiosensor is sensitive enough to detect herbicides in these matrices. Based on a 20-μL sample injection volume, the detection limits were 0.1 μg L-1 (10-10 M) for both glyphosate and glufosinate without sample clean-up or preconcentration.
- 1 January 2009
- Published by Walter de Gruyter GmbH in Pure and Applied Chemistry
- Vol. 81 (1) , 123-139
Amperometric nanobiosensor for quantitative determination of glyphosate and glufosinate residues in corn samples
This study presents a simple, sensitive, rapid, and low-cost amperometric method for direct and quantitative determination of glyphosate and glufosinate herbicides. Electrochemical synthesis and characterization of poly(2,5-dimethoxyaniline)-poly(4-styrenesulfonic acid) (PDMA-PSS) nanoparticles was achieved by cyclic voltammetry (CV) and scanning electron microscopy (SEM). The nanobiosensor was constructed by immobilizing the enzyme horseradish peroxidase (HRP) electrostatically onto the surface of a rotating gold disk electrode modified with PDMA-PSS nanoparticles. The biosensing principle was based on determination of the sensor response to glyphosate and glufosinate by amperometric methods. Hydrogen peroxide (H2O2) was used to measure activity of the enzyme before injection of the herbicides into the electrolyte solution. The enzyme electrode was stable for a long period of time and was used for over 60 measurements. Glyphosate and glufosinate analyses were realized on spiked corn samples within a concentration range of 2.0-78.0 μg L-1, corroborating that the nanobiosensor is sensitive enough to detect herbicides in these matrices. Based on a 20-μL sample injection volume, the detection limits were 0.1 μg L-1 (10-10 M) for both glyphosate and glufosinate without sample clean-up or preconcentration.
- Open Access
Electrochemical Immunosensor Based on Polythionine/Gold Nanoparticles for the Determination of Aflatoxin B1
An aflatoxin B1 (AFB1) electrochemical immunosensor was developed by the immobilisation of aflatoxin B1-bovine serum albumin (AFB1-BSA) conjugate on a polythionine (PTH)/gold nanoparticles (AuNP)-modified glassy carbon electrode (GCE). The surface of the AFB1-BSA conjugate was covered with horseradish peroxidase (HRP), in order to prevent non-specific binding of the immunosensors with ions in the test solution. The AFB1 immunosensor exhibited a quasi-reversible electrochemistry as indicated by a cyclic voltammetric (CV) peak separation (ΔEp) value of 62 mV. The experimental procedure for the detection of AFB1 involved the setting up of a competition between free AFB1 and the immobilised AFB1-BSA conjugate for the binding sites of free anti-aflatoxin B1 (anti-AFB1) antibody. The immunosensor’s differential pulse voltammetry (DPV) responses (peak currents) decreased as the concentration of free AFB1 increased within a dynamic linear range (DLR) of 0.6 - 2.4 ng/mL AFB1 and a limit of detection (LOD) of 0.07 ng/mL AFB1. This immunosensing procedure eliminates the need for enzyme-labeled secondary antibodies normally used in conventional ELISA–based immunosensors.
Open AccessElectrochemical Immunosensor Based on Polythionine/Gold Nanoparticles for the Determination of Aflatoxin B1
An aflatoxin B1 (AFB1) electrochemical immunosensor was developed by the immobilisation of aflatoxin B1-bovine serum albumin (AFB1-BSA) conjugate on a polythionine (PTH)/gold nanoparticles (AuNP)-modified glassy carbon electrode (GCE). The surface of the AFB1-BSA conjugate was covered with horseradish peroxidase (HRP), in order to prevent non-specific binding of the immunosensors with ions in the test solution. The AFB1 immunosensor exhibited a quasi-reversible electrochemistry as indicated by a cyclic voltammetric (CV) peak separation (ΔEp) value of 62 mV. The experimental procedure for the detection of AFB1 involved the setting up of a competition between free AFB1 and the immobilised AFB1-BSA conjugate for the binding sites of free anti-aflatoxin B1 (anti-AFB1) antibody. The immunosensor’s differential pulse voltammetry (DPV) responses (peak currents) decreased as the concentration of free AFB1 increased within a dynamic linear range (DLR) of 0.6 - 2.4 ng/mL AFB1 and a limit of detection (LOD) of 0.07 ng/mL AFB1. This immunosensing procedure eliminates the need for enzyme-labeled secondary antibodies normally used in conventional ELISA–based immunosensors.
- Open Access
An Electrochemical DNA Biosensor Developed on a Nanocomposite Platform of Gold and Poly(propyleneimine) Dendrimer
An electrochemical DNA nanobiosensor was prepared by immobilization of a 20mer thiolated probe DNA on electro-deposited generation 4 (G4) poly(propyleneimine) dendrimer (PPI) doped with gold nanoparticles (AuNP) as platform, on a glassy carbon electrode (GCE). Field emission scanning electron microscopy results confirmed the codeposition of PPI (which was linked to the carbon electrode surface by C-N covalent bonds) and AuNP ca 60 nm. Voltammetric interrogations showed that the platform (GCE/PPI-AuNP) was conducting and exhibited reversible electrochemistry (E°′ = 235 mV) in pH 7.2 phosphate buffer saline solution (PBS) due to the PPI component. The redox chemistry of PPI was pH dependent and involves a two electron, one proton process, as interpreted from a 28 mV/pH value obtained from pH studies. The charge transfer resistance (Rct) from the electrochemical impedance spectroscopy (EIS) profiles of GCE/PPI-AuNP monitored with ferro/ferricyanide (Fe(CN)63-/4-) redox probe, decreased by 81% compared to bare GCE. The conductivity (in PBS) and reduced Rct (in Fe(CN)63-/4-) values confirmed PPI-AuNP as a suitable electron transfer mediator platform for voltammetric and impedimetric DNA biosensor. The DNA probe was effectively wired onto the GCE/PPI-AuNP via Au-S linkage and electrostatic interactions. The nanobiosensor responses to target DNA which gave a dynamic linear range of 0.01 - 5 nM in PBS was based on the changes in Rct values using Fe(CN)63-/4- redox probe.
Open AccessAn Electrochemical DNA Biosensor Developed on a Nanocomposite Platform of Gold and Poly(propyleneimine) Dendrimer
An electrochemical DNA nanobiosensor was prepared by immobilization of a 20mer thiolated probe DNA on electro-deposited generation 4 (G4) poly(propyleneimine) dendrimer (PPI) doped with gold nanoparticles (AuNP) as platform, on a glassy carbon electrode (GCE). Field emission scanning electron microscopy results confirmed the codeposition of PPI (which was linked to the carbon electrode surface by C-N covalent bonds) and AuNP ca 60 nm. Voltammetric interrogations showed that the platform (GCE/PPI-AuNP) was conducting and exhibited reversible electrochemistry (E°′ = 235 mV) in pH 7.2 phosphate buffer saline solution (PBS) due to the PPI component. The redox chemistry of PPI was pH dependent and involves a two electron, one proton process, as interpreted from a 28 mV/pH value obtained from pH studies. The charge transfer resistance (Rct) from the electrochemical impedance spectroscopy (EIS) profiles of GCE/PPI-AuNP monitored with ferro/ferricyanide (Fe(CN)63-/4-) redox probe, decreased by 81% compared to bare GCE. The conductivity (in PBS) and reduced Rct (in Fe(CN)63-/4-) values confirmed PPI-AuNP as a suitable electron transfer mediator platform for voltammetric and impedimetric DNA biosensor. The DNA probe was effectively wired onto the GCE/PPI-AuNP via Au-S linkage and electrostatic interactions. The nanobiosensor responses to target DNA which gave a dynamic linear range of 0.01 - 5 nM in PBS was based on the changes in Rct values using Fe(CN)63-/4- redox probe.
- 28 October 2008
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 49 (2) , 498-501
Novel therapeutic biosensor for indinavir—A protease inhibitor antiretroviral drug
- 28 October 2008
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 49 (2) , 498-501
Novel therapeutic biosensor for indinavir—A protease inhibitor antiretroviral drug