Taksid Charasseangpaisarn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Taksid Charasseangpaisarn has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Chairat Wiwatwarrapan
Chulalongkorn Univ, Fac Dent, Dept Prosthodont, 254 Pathurnwan, Bangkok 10330, Thailand
2 shared publications Kamolporn Wattanasirmkit
2 shared publicationsAtikom Surintanasarn
1 shared publication- Atima Kurjirattikan
College of Dental Medicine, Rangsit University, Pathum Thani 12000, Thailand
1 shared publication - C Jongwannasiri
King Mongkut's University of Technology Thonburi (Ratchaburi Learning Park), Ratchaburi 70150, Thailand
1 shared publication - Chanidapa Sangkanchanavanich
College of Dental Medicine, Rangsit University, Pathum Thani 12000, Thailand
1 shared publication
Latest Publications
- 14 October 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 176
Effect of surface treatments on the flexural properties of repaired conventional and alternative denture base materials
- 14 October 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 176
Effect of surface treatments on the flexural properties of repaired conventional and alternative denture base materials
- Open Access
- 11 September 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (9) , 586
Influence of Zirconia Type and Surface Treatment on the Shear Bond Strength Between Veneering Porcelain and Zirconia
Background: Proximal contact loss is a major problem in zirconia restorations on implant abutments. This study investigated the effect of surface treatments on the shear bond strength (SBS) between veneering porcelain and translucent zirconia (4Y-PSZ and 5Y-PSZ) compared with conventional zirconia (3Y-TZP). Methods: Forty-four specimens of each zirconia type (10.0 × 7.0 × 1.0 mm) were prepared and randomly assigned to four surface treatment groups: control (C), grinding with 150-grit silicon carbide paper (GR), airborne-particle abrasion with alumina particles (AB), and glazing (GL). Surface roughness (Ra) was measured for one specimen from each treatment group. Veneering porcelain cylinders (2.38 mm in diameter, 0.5 mm in thickness) were fabricated and bonded to the zirconia surfaces. SBS was evaluated using a universal testing machine (n = 10). Data were analyzed using two-way ANOVA and Tukey’s HSD test (α = 0.05). Results: The GL group exhibited the lowest Ra, whereas the AB group showed the highest Ra. Regarding zirconia type, 3Y-TZP demonstrated significantly higher SBS than 5Y-PSZ, while no significant differences were found between 3Y-TZP and 4Y-PSZ or between 4Y-PSZ and 5Y-PSZ. The AB and GL groups showed significantly higher SBS than the C group, whereas the GR group did not differ significantly from the C group. Conclusions: Airborne-particle abrasion and glazing effectively enhanced SBS across the zirconia types evaluated prior to veneering.
- 11 September 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (9) , 586
Open AccessInfluence of Zirconia Type and Surface Treatment on the Shear Bond Strength Between Veneering Porcelain and Zirconia
Background: Proximal contact loss is a major problem in zirconia restorations on implant abutments. This study investigated the effect of surface treatments on the shear bond strength (SBS) between veneering porcelain and translucent zirconia (4Y-PSZ and 5Y-PSZ) compared with conventional zirconia (3Y-TZP). Methods: Forty-four specimens of each zirconia type (10.0 × 7.0 × 1.0 mm) were prepared and randomly assigned to four surface treatment groups: control (C), grinding with 150-grit silicon carbide paper (GR), airborne-particle abrasion with alumina particles (AB), and glazing (GL). Surface roughness (Ra) was measured for one specimen from each treatment group. Veneering porcelain cylinders (2.38 mm in diameter, 0.5 mm in thickness) were fabricated and bonded to the zirconia surfaces. SBS was evaluated using a universal testing machine (n = 10). Data were analyzed using two-way ANOVA and Tukey’s HSD test (α = 0.05). Results: The GL group exhibited the lowest Ra, whereas the AB group showed the highest Ra. Regarding zirconia type, 3Y-TZP demonstrated significantly higher SBS than 5Y-PSZ, while no significant differences were found between 3Y-TZP and 4Y-PSZ or between 4Y-PSZ and 5Y-PSZ. The AB and GL groups showed significantly higher SBS than the C group, whereas the GR group did not differ significantly from the C group. Conclusions: Airborne-particle abrasion and glazing effectively enhanced SBS across the zirconia types evaluated prior to veneering.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 33, e20250065
Trueness comparison of various intraoral scanners and hybrid workflow for ceramic restoration
The scanned abutment file for the digital design of restorations can be either obtained directly using the intraoral scanner (IOS) or scanning the impression or the working model with the extraoral scanner (EOS). The trueness of the scanned file pertains to its effect on the accuracy of the restoration. Objective This study aimed to compare the trueness of scan files from different intraoral scanners (IOSs) and the hybrid workflow using the E3 extraoral scanner (EOS) for ceramic restoration. Methodology The model of the mandibular right first molar was prepared for the ceramic crown, and it was scanned with the EOS in reference Standard Tessellation Language (STL) file format. The following seven experimental groups were investigated. The IOSs—iTero Element 5D (IT), Trios 4 (TF), Medit i700 (MI), Primescan (PM), Virtuo Vivo (VV)—were directly scanned on the prepared model. The silicone impression of the prepared model was scanned with EOS (IS). The working model poured from the impression was scanned with the EOS (WS). The test STL file was trimmed and superimposed on the reference STL file for the trueness assessment using Geomagic Control X. The point deviation at the surface and margin of each group were compared. The mean deviation was calculated and statistically analyzed with One-way ANOVA (α=0.05). The minimum and maximum deviation of each area were also recorded. Results Compared with the other groups, the impression scan group had a significantly greatest deviation (p<0.05) in surface (37.65±1.14 µm), margin (63.57±5.85 µm) and overall (50.61±3.28 µm). The WS group showed significantly greater deviation (p<0.05) in surface (23.93±1.20 µm), margin (46.18±2.00 µm) and overall (35.05±1.16 µm) than the IOS groups. In some IOS groups, the deviation was also significantly different (p<0.05). Conclusion The IOS is recommended for obtaining the scanned file due to its lesser deviation when compared to the hybrid workflow. While statistical differences exist among IOSs, the clinical relevance of these differences appears minimal. If the IOS does not exist, scanning the working model is preferred over scanning impressions directly. However, further clinical validation studies are necessary to confirm this finding.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 33, e20250065
Open AccessTrueness comparison of various intraoral scanners and hybrid workflow for ceramic restoration
The scanned abutment file for the digital design of restorations can be either obtained directly using the intraoral scanner (IOS) or scanning the impression or the working model with the extraoral scanner (EOS). The trueness of the scanned file pertains to its effect on the accuracy of the restoration. Objective This study aimed to compare the trueness of scan files from different intraoral scanners (IOSs) and the hybrid workflow using the E3 extraoral scanner (EOS) for ceramic restoration. Methodology The model of the mandibular right first molar was prepared for the ceramic crown, and it was scanned with the EOS in reference Standard Tessellation Language (STL) file format. The following seven experimental groups were investigated. The IOSs—iTero Element 5D (IT), Trios 4 (TF), Medit i700 (MI), Primescan (PM), Virtuo Vivo (VV)—were directly scanned on the prepared model. The silicone impression of the prepared model was scanned with EOS (IS). The working model poured from the impression was scanned with the EOS (WS). The test STL file was trimmed and superimposed on the reference STL file for the trueness assessment using Geomagic Control X. The point deviation at the surface and margin of each group were compared. The mean deviation was calculated and statistically analyzed with One-way ANOVA (α=0.05). The minimum and maximum deviation of each area were also recorded. Results Compared with the other groups, the impression scan group had a significantly greatest deviation (p<0.05) in surface (37.65±1.14 µm), margin (63.57±5.85 µm) and overall (50.61±3.28 µm). The WS group showed significantly greater deviation (p<0.05) in surface (23.93±1.20 µm), margin (46.18±2.00 µm) and overall (35.05±1.16 µm) than the IOS groups. In some IOS groups, the deviation was also significantly different (p<0.05). Conclusion The IOS is recommended for obtaining the scanned file due to its lesser deviation when compared to the hybrid workflow. While statistical differences exist among IOSs, the clinical relevance of these differences appears minimal. If the IOS does not exist, scanning the working model is preferred over scanning impressions directly. However, further clinical validation studies are necessary to confirm this finding.
- Open Access
- 10 August 2021
- Published by Wiley in International Journal of Dentistry
- Vol. 2021, 1-9
The Influence of Different Surface Cleansing Agents on Shear Bond Strength of Contaminated Lithium Disilicate Ceramic: An In Vitro Study
Background and Purpose. Contamination of the lithium disilicate (LDS) during the try-in procedure is unavoidable and may weaken the bond strength of restoration. The purpose of this study was to investigate the efficacy of different surface cleansing agents on the shear bond strength (SBS) of contaminated LDS. Materials and Methods. Seventy LDS specimens were randomly divided into seven groups. The first group was noncontaminated surface (PC). The six other groups were contaminated with the saliva and silicone disclosing medium and treated with no surface cleansing agent (NC); phosphoric acid (PO); Ivoclean (IV); sodium hydroxide solution (NA); Restorative Cleansing Agent (RC); and hydrofluoric acid (HF). Then, LDS specimens were cementated with Panavia V5 to resin composite rod. Each specimen was subjected to an SBS test. The modes of failure was inspected under light microscope. The surface element of each group was examined by SEM-EDS. Results. The results were analyzed with one-way ANOVA and Tamhane’s T2. The mean SBS value of NC was significantly lower than others ( ), and HF was significantly higher than others ( ). However, PC, PO, IV, NA, and RC were not significantly different from each other ( ). The mode of failure was mostly adhesive failure in every group. The surface showed similar amount of elements in every group. Conclusions. The SBS of LDS was reduced by saliva and silicone disclosing medium contamination which can be restored using acid- and alkaline-based surface cleansing agents before the cementation procedure.
- 10 August 2021
- Published by Wiley in International Journal of Dentistry
- Vol. 2021, 1-9
Open AccessThe Influence of Different Surface Cleansing Agents on Shear Bond Strength of Contaminated Lithium Disilicate Ceramic: An In Vitro Study
Background and Purpose. Contamination of the lithium disilicate (LDS) during the try-in procedure is unavoidable and may weaken the bond strength of restoration. The purpose of this study was to investigate the efficacy of different surface cleansing agents on the shear bond strength (SBS) of contaminated LDS. Materials and Methods. Seventy LDS specimens were randomly divided into seven groups. The first group was noncontaminated surface (PC). The six other groups were contaminated with the saliva and silicone disclosing medium and treated with no surface cleansing agent (NC); phosphoric acid (PO); Ivoclean (IV); sodium hydroxide solution (NA); Restorative Cleansing Agent (RC); and hydrofluoric acid (HF). Then, LDS specimens were cementated with Panavia V5 to resin composite rod. Each specimen was subjected to an SBS test. The modes of failure was inspected under light microscope. The surface element of each group was examined by SEM-EDS. Results. The results were analyzed with one-way ANOVA and Tamhane’s T2. The mean SBS value of NC was significantly lower than others ( ), and HF was significantly higher than others ( ). However, PC, PO, IV, NA, and RC were not significantly different from each other ( ). The mode of failure was mostly adhesive failure in every group. The surface showed similar amount of elements in every group. Conclusions. The SBS of LDS was reduced by saliva and silicone disclosing medium contamination which can be restored using acid- and alkaline-based surface cleansing agents before the cementation procedure.
- 16 June 2021
- Published by Chiang Mai University in Chiang Mai University Journal of Natural Sciences
- Vol. 20 (3)
Reduction of Insertion Torque on Orthodontic Mini-screw Implant by means of Reduced Friction
In this article, the reduction of insertion torque on the orthodontic mini-screw implants (OMI) was studied. Three types of diamond-like carbon (DLC) films (DLC, Si-DLC, and F-DLC) were deposited on the OMIs by plasma-based ion implantation technique. The maximum insertion torque (MIT) value was measured using a physiodispenser during insertion on a mandibular pig jaw. Ten OMIs of each condition were used to evaluate the MIT values compared to the Ti-6Al-4V typed OMI. The statistical analysis of data was analyzed by One-way analysis of variance (ANOVA) and Tukey HSD. The results indicated that the Ti-6Al-4V showed the highest MIT but not significantly different from the F-DLC (P >0.05). DLC and Si-DLC showed a significant reduction in MIT comparing to the Ti-6Al-4V (P P Keywords: Diamond-like carbon, Friction, Insertion torque, Mini-screw implant Funding: The authors declare that there is no research funding for this article. Citation: Jongwannasiri, C., Charasseangpaisarn, T., and Watanabe, S. 2021. Reduction of insertion torque on orthodontic mini-screw implant by means of reduced friction. CMUJ. Nat. Sci. 20(3): e2021060.
- 16 June 2021
- Published by Chiang Mai University in Chiang Mai University Journal of Natural Sciences
- Vol. 20 (3)
Reduction of Insertion Torque on Orthodontic Mini-screw Implant by means of Reduced Friction
In this article, the reduction of insertion torque on the orthodontic mini-screw implants (OMI) was studied. Three types of diamond-like carbon (DLC) films (DLC, Si-DLC, and F-DLC) were deposited on the OMIs by plasma-based ion implantation technique. The maximum insertion torque (MIT) value was measured using a physiodispenser during insertion on a mandibular pig jaw. Ten OMIs of each condition were used to evaluate the MIT values compared to the Ti-6Al-4V typed OMI. The statistical analysis of data was analyzed by One-way analysis of variance (ANOVA) and Tukey HSD. The results indicated that the Ti-6Al-4V showed the highest MIT but not significantly different from the F-DLC (P >0.05). DLC and Si-DLC showed a significant reduction in MIT comparing to the Ti-6Al-4V (P P Keywords: Diamond-like carbon, Friction, Insertion torque, Mini-screw implant Funding: The authors declare that there is no research funding for this article. Citation: Jongwannasiri, C., Charasseangpaisarn, T., and Watanabe, S. 2021. Reduction of insertion torque on orthodontic mini-screw implant by means of reduced friction. CMUJ. Nat. Sci. 20(3): e2021060.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1380 (1) , 012062
Preliminary testing for reduction of insertion torque of orthodontic mini-screw implant using diamond-like carbon films
Nowadays, titanium alloy is widely used as orthodontic mini-screw implants due to its suitable mechanical properties and excellence in biocompatibility. However, the excessive torques applied during the insertion of orthodontic mini-screw implant can cause necrosis of the surrounding bone. In this article, the insertion torque of orthodontic mini-screw implants is aimed to reduce during treatment by means of surface coating. The three types of coatings, namely, DLC, F-DLC 2:1 and Si-DLC 2:1 coated on orthodontic mini-screw implants were chosen to take into account the insertion torque values compared with uncoated surface. The friction behaviors of the films in ambient air and dry air were assessed using ball-on-disk friction testing. Cytotoxicity tests were performed using MTT assay. The insertion torque values were measured by physiodispenser. The results indicated that, both measured in ambient air and dry air, the addition of F into the DLC films slightly influenced the friction coefficients, while doping with Si strongly influenced the films. These films also exhibited less cytotoxicity on their surfaces. Furthermore, the insertion torque values decreased when coated orthodontic mini-screw implants with F-DLC 2:1 and Si-DLC 2:1 films. Therefore, the F-DLC 2:1 and Si-DLC 2:1 films can be considered to apply on orthodontic mini-screw implant for reducing the insertion torque.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1380 (1) , 012062
Open AccessPreliminary testing for reduction of insertion torque of orthodontic mini-screw implant using diamond-like carbon films
Nowadays, titanium alloy is widely used as orthodontic mini-screw implants due to its suitable mechanical properties and excellence in biocompatibility. However, the excessive torques applied during the insertion of orthodontic mini-screw implant can cause necrosis of the surrounding bone. In this article, the insertion torque of orthodontic mini-screw implants is aimed to reduce during treatment by means of surface coating. The three types of coatings, namely, DLC, F-DLC 2:1 and Si-DLC 2:1 coated on orthodontic mini-screw implants were chosen to take into account the insertion torque values compared with uncoated surface. The friction behaviors of the films in ambient air and dry air were assessed using ball-on-disk friction testing. Cytotoxicity tests were performed using MTT assay. The insertion torque values were measured by physiodispenser. The results indicated that, both measured in ambient air and dry air, the addition of F into the DLC films slightly influenced the friction coefficients, while doping with Si strongly influenced the films. These films also exhibited less cytotoxicity on their surfaces. Furthermore, the insertion torque values decreased when coated orthodontic mini-screw implants with F-DLC 2:1 and Si-DLC 2:1 films. Therefore, the F-DLC 2:1 and Si-DLC 2:1 films can be considered to apply on orthodontic mini-screw implant for reducing the insertion torque.
- 1 July 2019
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 63 (3) , 271-276
Effect of different cleansing agents and adhesive resins on bond strength of contaminated zirconia
This study was observed the effect of cleansing agents and adhesive resins on shear bond strength (SBS), surface morphology and phase transformation of saliva and silicone disclosing medium contaminated zirconia. The 110 zirconia specimens size 5×5×1mm were fabricated and randomly divided into 5 surface treated groups: Non-contaminated (PC) Saliva and silicone disclosing medium contaminated without cleansing (NC) Surface contaminated and cleansing with Phosphoric acid (PO) Ivoclean (IC) or Hydrofluoric acid (HF). The twenty of each surface treated specimens were selected and bonded with Panavia F2.0 (P) and Superbond C&B (S) for SBS test (n=10). The data was analyzed by Kruskal-Wallis H and Mann-Whitney U test. The remaining specimens of each surface treated groups were examined by SEM and XRD. The saliva and silicone disclosing medium contaminated zirconia without cleansing group (PNC) had the lowest SBS when Panavia F2.0 was used for cementation (p0.05). However, there were no difference in SBS among groups when cementation with Superbond C&B (SPC, SNC, SPO, SIC and SHF) (p>0.05). There was no morphologic changing that could be observed by SEM. The XRD showed little phase transformation when surfaces were contaminated and cleaned. The saliva and silicone disclosing medium contaminated zirconia should be cleaned with Phosphoric acid, Ivoclean or Hydrofluoric acid for 20s prior to cementation with Panavia F2.0. However, the surface cleansing was not necessary when cementation with Superbond C&B.
- 1 July 2019
- Published by Japan Prosthodontic Society in Journal of Prosthodontic Research
- Vol. 63 (3) , 271-276
Effect of different cleansing agents and adhesive resins on bond strength of contaminated zirconia
This study was observed the effect of cleansing agents and adhesive resins on shear bond strength (SBS), surface morphology and phase transformation of saliva and silicone disclosing medium contaminated zirconia. The 110 zirconia specimens size 5×5×1mm were fabricated and randomly divided into 5 surface treated groups: Non-contaminated (PC) Saliva and silicone disclosing medium contaminated without cleansing (NC) Surface contaminated and cleansing with Phosphoric acid (PO) Ivoclean (IC) or Hydrofluoric acid (HF). The twenty of each surface treated specimens were selected and bonded with Panavia F2.0 (P) and Superbond C&B (S) for SBS test (n=10). The data was analyzed by Kruskal-Wallis H and Mann-Whitney U test. The remaining specimens of each surface treated groups were examined by SEM and XRD. The saliva and silicone disclosing medium contaminated zirconia without cleansing group (PNC) had the lowest SBS when Panavia F2.0 was used for cementation (p0.05). However, there were no difference in SBS among groups when cementation with Superbond C&B (SPC, SNC, SPO, SIC and SHF) (p>0.05). There was no morphologic changing that could be observed by SEM. The XRD showed little phase transformation when surfaces were contaminated and cleaned. The saliva and silicone disclosing medium contaminated zirconia should be cleaned with Phosphoric acid, Ivoclean or Hydrofluoric acid for 20s prior to cementation with Panavia F2.0. However, the surface cleansing was not necessary when cementation with Superbond C&B.
- Open Access
- 1 December 2016
- Published by Elsevier in Journal of Dental Sciences
- Vol. 11 (4) , 443-448
Ultrasonic cleaning reduces the residual monomer in acrylic resins
- 1 December 2016
- Published by Elsevier in Journal of Dental Sciences
- Vol. 11 (4) , 443-448
Open AccessUltrasonic cleaning reduces the residual monomer in acrylic resins
- 1 December 2015
- Published by Elsevier in Ultrasonics
- Vol. 63, 163-167
The effect of various frequencies of ultrasonic cleaner in reducing residual monomer in acrylic resin
- 1 December 2015
- Published by Elsevier in Ultrasonics
- Vol. 63, 163-167
The effect of various frequencies of ultrasonic cleaner in reducing residual monomer in acrylic resin