Ricarda Torre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ricarda Torre has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Hendrikus Petrus Antonius Nouws
REQUIMTE/LAQV, Instituto Superior de Engenharia do Porto, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida 431, 4249-015 Porto, Portugal
4 shared publications - Estefanía Costa-Rama
Universidad de Oviedo
3 shared publications Cristina Delerue-Matos
2 shared publications- Cristina Delerue-Matos
REQUIMTE/LAQV, ISEP/IPP—Polytechnic of Porto—School of Engineering, Rua Doutor António Bernardino de Almeida, 431, 4249-015 Porto, Portugal
2 shared publications Isabel Seguro
1 shared publication- Joana Soares Amaral
CIMO, LA SusTEC, Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal
1 shared publication
Latest Publications
- Open Access
- 21 April 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 462
Turn-off/on fluorescent sensor for SARS-CoV-2 detection using waste-derived carbon dots
- 21 April 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 462
Open AccessTurn-off/on fluorescent sensor for SARS-CoV-2 detection using waste-derived carbon dots
- Open Access
Advances in Carbon Dot-Based Optical (Bio)Sensors for Contaminant Detection in Wastewater-Based Epidemiology
Wastewater-based epidemiology (WBE) has emerged as a powerful approach for population-level monitoring of chemical exposure, health status, and disease transmission by analysing wastewater. Although chromatographic and molecular techniques remain the gold standard in WBE, their high cost, infrastructural demands, and limited suitability for decentralized and real-time monitoring motivate the development of complementary sensing technologies. In this context, optical (bio)sensors, particularly fluorescence-based platforms, have attracted increasing attention due to their high sensitivity, rapid response, and potential for on-site monitoring. This review discusses recent advances in fluorescent optical (bio)sensors for WBE, with a particular focus on carbon dots (CDs), including waste- and biomass-derived CDs produced via green synthesis as well as CDs obtained from commercial chemicals. The applicability of CD-based sensors to wastewater-relevant analytes is evaluated, highlighting current achievements, as well as existing limitations and challenges related to real-sample validation and the translation of these platforms into robust, field-deployable systems for their implementation in sustainable wastewater monitoring and public health surveillance.
Open AccessAdvances in Carbon Dot-Based Optical (Bio)Sensors for Contaminant Detection in Wastewater-Based Epidemiology
Wastewater-based epidemiology (WBE) has emerged as a powerful approach for population-level monitoring of chemical exposure, health status, and disease transmission by analysing wastewater. Although chromatographic and molecular techniques remain the gold standard in WBE, their high cost, infrastructural demands, and limited suitability for decentralized and real-time monitoring motivate the development of complementary sensing technologies. In this context, optical (bio)sensors, particularly fluorescence-based platforms, have attracted increasing attention due to their high sensitivity, rapid response, and potential for on-site monitoring. This review discusses recent advances in fluorescent optical (bio)sensors for WBE, with a particular focus on carbon dots (CDs), including waste- and biomass-derived CDs produced via green synthesis as well as CDs obtained from commercial chemicals. The applicability of CD-based sensors to wastewater-relevant analytes is evaluated, highlighting current achievements, as well as existing limitations and challenges related to real-sample validation and the translation of these platforms into robust, field-deployable systems for their implementation in sustainable wastewater monitoring and public health surveillance.
- Open Access
- 18 August 2025
- Published by Elsevier in Electrochimica Acta
- Vol. 540
Molecularly imprinted polymer-based sensor for the determination of 2,4-dinitrophenol in food supplements
- 18 August 2025
- Published by Elsevier in Electrochimica Acta
- Vol. 540
Open AccessMolecularly imprinted polymer-based sensor for the determination of 2,4-dinitrophenol in food supplements
- Open Access
- 5 February 2020
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 11 (1) , 1-8
Diamine oxidase-modified screen-printed electrode for the redox-mediated determination of histamine
Histamine is an important biogenic amine because of its role in immune responses and the regulation of physiological functions. It is also used as a food freshness indicator, so its maximum concentration in fish is legally regulated. Although several robust and sensitive methods for histamine detection are already available, it continues to be a challenge to develop simple and portable devices that allow rapid histamine screening at any point of the fish production chain. Thus, in this work, a simple, miniaturized and low-cost sensor for histamine analysis was developed. The construction of the sensor only takes 30 min and consists of the immobilization of the enzyme diamine oxidase on the surface of a screen-printed carbon electrode by cross-linking. The quantification of histamine was achieved by chronoamperometry (+ 0.2V, 120 s) using hexacyanoferrate (III) as a redox mediator. This selective sensor provided a low limit of detection (0.97 mg L−1) and accurate and precise results and was successfully applied to the analysis of spiked tuna and mackerel extracts, obtaining recovery values of 99–100%. Moreover, the sensor shows good stability, maintaining 87.7% of its initial signal after 35 days.
- 5 February 2020
- Published by Springer Nature in Journal of Analytical Science and Technology
- Vol. 11 (1) , 1-8
Open AccessDiamine oxidase-modified screen-printed electrode for the redox-mediated determination of histamine
Histamine is an important biogenic amine because of its role in immune responses and the regulation of physiological functions. It is also used as a food freshness indicator, so its maximum concentration in fish is legally regulated. Although several robust and sensitive methods for histamine detection are already available, it continues to be a challenge to develop simple and portable devices that allow rapid histamine screening at any point of the fish production chain. Thus, in this work, a simple, miniaturized and low-cost sensor for histamine analysis was developed. The construction of the sensor only takes 30 min and consists of the immobilization of the enzyme diamine oxidase on the surface of a screen-printed carbon electrode by cross-linking. The quantification of histamine was achieved by chronoamperometry (+ 0.2V, 120 s) using hexacyanoferrate (III) as a redox mediator. This selective sensor provided a low limit of detection (0.97 mg L−1) and accurate and precise results and was successfully applied to the analysis of spiked tuna and mackerel extracts, obtaining recovery values of 99–100%. Moreover, the sensor shows good stability, maintaining 87.7% of its initial signal after 35 days.
- 8 February 2019
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 11 (9) , 1264-1269
Amperometric enzyme sensor for the rapid determination of histamine
The concentration of histamine, a biogenic amine, in fish is considered a fish spoilage indicator. Therefore, the development of a rapid-response and portable tool that allows its on-site analysis is very interesting since the consumption of high amounts of histamine causes scombroid poisoning. Thus, in this work a simple enzymatic sensor for the determination of histamine, based on a screen-printed carbon electrode and the enzyme diamine oxidase, was developed. The enzyme was immobilized on the electrode surface through a simple cross-linking procedure employing glutaraldehyde and bovine serum albumin. Chronoamperometry was used as the detection technique; the sensor showed a short response time (60 s, −0.3 V) and the measurements were performed by only using 40 μL of sample solution. The sensor provides a useful linear range (between 1 and 75 mg L−1 in fish extract), excellent reproducibility (RSD = 2.6%) and is reusable for up to 7 measurements. The feasibility of the sensor was tested performing histamine analysis in fish extracts achieving recovery values of 103%.
- 8 February 2019
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 11 (9) , 1264-1269
Amperometric enzyme sensor for the rapid determination of histamine
The concentration of histamine, a biogenic amine, in fish is considered a fish spoilage indicator. Therefore, the development of a rapid-response and portable tool that allows its on-site analysis is very interesting since the consumption of high amounts of histamine causes scombroid poisoning. Thus, in this work a simple enzymatic sensor for the determination of histamine, based on a screen-printed carbon electrode and the enzyme diamine oxidase, was developed. The enzyme was immobilized on the electrode surface through a simple cross-linking procedure employing glutaraldehyde and bovine serum albumin. Chronoamperometry was used as the detection technique; the sensor showed a short response time (60 s, −0.3 V) and the measurements were performed by only using 40 μL of sample solution. The sensor provides a useful linear range (between 1 and 75 mg L−1 in fish extract), excellent reproducibility (RSD = 2.6%) and is reusable for up to 7 measurements. The feasibility of the sensor was tested performing histamine analysis in fish extracts achieving recovery values of 103%.