STSteven Tilley

Steven Tilley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steven Tilley has a total of 59 co-authors. Here are the top co-authors by number of shared publications:

  • Joseph Webster Stayman

    Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States

    11 shared publications
  • Wojciech Zbijewski

    Department of Biomedical Engineering, Johns Hopkins University, Room 726, Taylor Building, 720 Rutland Avenue, Baltimore, Maryland, MD 21205, USA, Baltimore, Maryland, UNITED STATES

    5 shared publications
  • Jeffrey H Siewerdsen

    Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America

    4 shared publications
  • Jeffrey H. Siewerdsen

    Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD

    3 shared publications
  • Karim S. Karim

    Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, ON, Canada

    3 shared publications
  • Qian Cao

    Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America

    3 shared publications

Latest Publications

  • SpaceXray: Feasibility and Diagnostic Capabilities of On-Orbit Medical Radiography

    by Sheyna E. Gifford, Michael Pohlen, Adam S. Wang, David J. Lerner, Anna Wadhwa, Michael Cairnie, Jeanne Walter, Karim S. Karim, Steven Tilley, Amol Karnick, et al.

    By acquiring the first human and equipment radiographs in space, this study demonstrated the feasibility of on-orbit radiography and expanded diagnostic capabilities for crew health and hardware evaluation.


  • Open Access

    Opportunistic Identification of Coronary Artery Calcium and Valve/Vascular Calcifications on Chest X-Ray: Improvements With Single-ExposureDual-Energy Imaging

    by Patrik Rogalla, Jonatas Favero Prietto Dos Santos, Bernd J. Wintersperger, Jay Potipcoe, Steve Tilley, Nathan Speck, Neda Afkhami, Karim S. Karim, Sean Carey, Farah Cadour, et al.

    Purpose: To evaluate whether single-exposure, dual-energy chest X-ray (DEX) improves visualization of coronary artery calcium (CAC) and valve/vascular calcifications compared to conventional X-ray. Materials and Methods: Sixty-one bone-marrow transplant patients (22- 79 years; median 61; IQR 15; w/m, 24/37), underwent single-exposure dual-energy X-ray (Reveal 35C, KA imaging) in pa and lateral projection, followed by a standard-of-care chest CT. Two DEX pairs (pa/lateral) were calculated: a composite image (COMP) and a bone image with soft-tissue subtraction (BI). The COMP pair was reviewed by 2 chest radiologists, assessing the presence/absence of CAC and valve/vascular calcifications on a confidence scale from −2 (confidently not present) to 2 (confidently present). Subsequently, the BI pair was revealed, and readers reevaluated both pairs (COMP and BI) jointly using the identical scale. CTCAC scores were categorized according to the CAC-DRS (0-3) and served as standard of reference, valve/vascular calcifications were categorized on CT as present or absent. Results: For detecting CAC on DEX in any CAC-DRS category (1-3), in category 2-3, in category 3, and for valve/vascular calcifications, the ROC-AUC (combined for both readers) for COMP images was 0.74 (CI: 0.64-0.84), 0.81 (CI: 0.68-0.94), 0.84 (CI: 0.69-0.98), and 0.90 (CI: 0.83-0.99), and for the BI images 0.91 (CI: 0.83-0.98), 0.94 (CI: 0.86- 1.00), 0.89 (CI: 0.77-1.00), and 0.98 (CI: 0.96-1.00), with P = .0003, P = .044, P = .42, and P = .55, respectively. The Intraclass-Correlation-Coefficient (ICC) for CAC on COMP/BI was 0.973/0.954, and for valve/vascular calcifications 0.971/0.965. Conclusion: Single-exposure, dual-energy acquisition improves diagnostic confidence for coronary artery calcium and valve/vascular calcification identification on chest X-rays.


  • Portable triple layer single-exposure spectral X-ray detector for non-destructive test X-ray imaging applications

    by Steven Tilley Ii, Curtis Larocca, Gary Allan, Jim Harp, Ka Imaging, Karim S. Karim, University of Waterloo

    Dual-energy subtraction (DES) imaging is well known to subtract materials of different atomic numbers (e.g. high Z and low Z values) and thus, enable material classification. Current approaches to DES imaging have trade-offs, such as motion artifacts, low sensitivity due to losses in a mid-filter, and a lack of portability. Recently, a portable triple-layer flat panel detector (FPD) was demonstrated for use in single-shot diagnostic medical DES imaging that could simultaneously provide improved sensitivity and removal of patient motion artifacts. In this work, we evaluate the feasibility of such a detector for portable NDT X-ray imaging. Various image quality metrics and practical images are provided.

  • Model-based dual-energy tomographic image reconstruction of objects containing known metal components

    by Stephen Z Liu, Qian Cao, Matthew Tivnan, Steven Tilley Ii, Jeffrey H Siewerdsen, J Webster Stayman, Wojciech Zbijewski

    Dual-energy (DE) decomposition has been adopted in orthopedic imaging to measure bone composition and visualize intraarticular contrast enhancement. One of the potential applications involves monitoring of callus mineralization for longitudinal assessment of fracture healing. However, fracture repair usually involves internal fixation hardware that can generate significant artifacts in reconstructed images. To address this challenge, we develop a novel algorithm that combines simultaneous reconstruction-decomposition using a previously reported method for model-based material decomposition (MBMD) augmented by the known-component (KC) reconstruction framework to mitigate metal artifacts. We apply the proposed algorithm to simulated DE data representative of a dedicated extremity cone-beam CT (CBCT) employing an x-ray unit with three vertically arranged sources. The scanner generates DE data with non-coinciding high- and low-energy projection rays when the central source is operated at high tube potential and the peripheral sources at low potential. The proposed algorithm was validated using a digital extremity phantom containing varying concentrations of Ca-water mixtures and Ti implants. Decomposition accuracy was compared to MBMD without the KC model. The proposed method suppressed metal artifacts and yielded estimated Ca concentrations that approached the reconstructions of an implant-free phantom for most mixture regions. In the vicinity of simple components, the errors of Ca density estimates obtained by incorporating KC in MBMD were ∼1.5–5× lower than the errors of conventional MBMD; for cases with complex implants, the errors were ∼3–5× lower. In conclusion, the proposed method can achieve accurate bone mineral density measurements in the presence of metal implants using non-coinciding DE projections acquired on a multisource CBCT system.


  • Open Access

    Blind deconvolution in model-based iterative reconstruction for CT using a normalized sparsity measure

    by Lorenz Hehn, Steven Tilley, Franz Pfeiffer, Joseph Webster Stayman

    Model-based iterative reconstruction techniques for CT that include a description of the noise statistics and a physical forward model of the image formation process have proven to increase image quality for many applications. Specifically, including models of the system blur into the physical forward model and thus implicitly performing a deconvolution of the projections during tomographic reconstruction, could demonstrate distinct improvements, especially in terms of resolution. However, the results strongly rely on an exact characterization of all components contributing to the system blur. Such characterizations can be laborious and even a slight mismatch can diminish image quality significantly. Therefore, we introduce a novel objective function, which enables us to jointly estimate system blur parameters during tomographic reconstruction. Conventional objective functions are biased in terms of blur and can yield lowest cost to blurred reconstructions with low noise levels. A key feature of our objective function is a new normalized sparsity measure for CT based on total-variation regularization, constructed to be less biased in terms of blur. We outline a solving strategy for jointly recovering low-dimensional blur parameters during tomographic reconstruction. We perform an extensive simulation study, evaluating the performance of the regularization and the dependency of the different parts of the objective function on the blur parameters. Scenarios with different regularization strengths and system blurs are investigated, demonstrating that we can recover the blur parameter used for the simulations. The proposed strategy is validated and the dependency of the objective function with the number of iterations is analyzed. Finally, our approach is experimentally validated on test-bench data of a human wrist phantom, where the estimated blur parameter coincides well with visual inspection. Our findings are not restricted to attenuation-based CT and may facilitate the recovery of more complex imaging model parameters.


  • Model-based material decomposition with a penalized nonlinear least-squares CT reconstruction algorithm

    by Steven Tilley, Wojciech Zbijewski, Joseph Webster Stayman

    Spectral information in CT may be used for material decomposition to produce accurate reconstructions of material density and to separate materials with similar overall attenuation. Traditional methods separate the reconstruction and decomposition steps, often resulting in undesirable trade-offs (e.g. sampling constraints, a simplified spectral model). In this work, we present a model-based material decomposition algorithm which performs the reconstruction and decomposition simultaneously using a multienergy forward model. In a kV-switching simulation study, the presented method is capable of reconstructing iodine at 0.5 mg ml −1 with a contrast-to-noise ratio greater than two, as compared to 3.0 mg ml −1 for image domain decomposition. The presented method also enables novel acquisition methods, which was demonstrated in this work with a combined kV-switching/split-filter acquisition explored in simulation and physical test bench studies. This novel design used four spectral channels to decompose three materials: water, iodine, and gadolinium. In simulation, the presented method accurately reconstructed concentration value estimates with RMSE values of 4.86 mg ml −1 for water, 0.108 mg ml −1 for iodine and 0.170 mg ml −1 for gadolinium. In test-bench data, the RMSE values were 134 mg ml −1 , 5.26 mg ml −1 and 1.85 mg ml −1 , respectively. These studies demonstrate the ability of model-based material decomposition to produce accurate concentration estimates in challenging spatial/spectral sampling acquisitions.


  • Penalized-Likelihood Reconstruction With High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging

    by Steven Tilley, Matthew Jacobson, Qian Cao, Michael Brehler, Alejandro Sisniega, Wojciech Zbijewski, J. Webster Stayman

    We present a novel reconstruction algorithm based on a general cone-beam CT forward model which is capable of incorporating the blur and noise correlations that are exhibited in flat-panel CBCT measurement data. Specifically, the proposed model may include scintillator blur, focal-spot blur, and noise correlations due to light spread in the scintillator. The proposed algorithm (GPL-BC) uses a Gaussian Penalized- Likelihood objective function which incorporates models of Blur and Correlated noise. In a simulation study, GPL-BC was able to achieve lower bias as compared to deblurring followed by FDK as well as a model-based reconstruction method without integration of measurement blur. In the same study, GPLBC was able to achieve better line-pair reconstructions (in terms of segmented-image accuracy) as compared to deblurring followed by FDK, a model based method without blur, and a model based method with blur but not noise correlations. A prototype extremities quantitative cone-beam CT test bench was used to image a physical sample of human trabecular bone. These data were used to compare reconstructions using the proposed method and model based methods without blur and/or correlation to a registered µCT image of the same bone sample. The GPL-BC reconstructions resulted in more accurate trabecular bone segmentation. Multiple trabecular bone metrics, including Trabecular Thickness (Tb.Th.) were computed for each reconstruction approach as well as the µCT volume. The GPL-BC reconstruction provided the most accurate Tb.Th. measurement, 0.255mm, as compared to the µCT derived value of 0.193mm, followed by the GPL-B reconstruction, the GPL-I reconstruction, and then the FDK reconstruction (0.271mm, 0.309mm, and 0.335mm, respectively).


  • Deformable known component model-based reconstruction for coronary CT angiography

    by X. Zhang, S. Tilley, S. Xu, A. Mathews, E. R. McVeigh, J. W. Stayman

    Purpose: Atherosclerosis detection remains challenging in coronary CT angiography for patients with cardiac implants. Pacing electrodes of a pacemaker or lead components of a defibrillator can create substantial blooming and streak artifacts in the heart region, severely hindering the visualization of a plaque of interest. We present a novel reconstruction method that incorporates a deformable model for metal leads to eliminate metal artifacts and improve anatomy visualization even near the boundary of the component. Methods: The proposed reconstruction method, referred as STF-dKCR, includes a novel parameterization of the component that integrates deformation, a 3D-2D preregistration process that estimates component shape and position, and a polyenergetic forward model for x-ray propagation through the component where the spectral properties are jointly estimated. The methodology was tested on physical data of a cardiac phantom acquired on a CBCT testbench. The phantom included a simulated vessel, a metal wire emulating a pacing lead, and a small Teflon sphere attached to the vessel wall, mimicking a calcified plaque. The proposed method was also compared to the traditional FBP reconstruction and an interpolation-based metal correction method (FBP-MAR). Results: Metal artifacts presented in standard FBP reconstruction were significantly reduced in both FBP-MAR and STF- dKCR, yet only the STF-dKCR approach significantly improved the visibility of the small Teflon target (within 2 mm of the metal wire). The attenuation of the Teflon bead improved to 0.0481 mm-1 with STF-dKCR from 0.0166 mm-1 with FBP and from 0.0301 mm-1 with FBP-MAR – much closer to the expected 0.0414 mm-1. Conclusion: The proposed method has the potential to improve plaque visualization in coronary CT angiography in the presence of wire-shaped metal components.


    • 1 July 2016
      • Vol. 2016, 29-32

    Design of dual multiple aperture devices for dynamical fluence field modulated CT.

    by Aswin John Mathews, Steven Tilley, Grace Gang, Satomi Kawamoto, Wojciech Zbijewski, Jeffrey H Siewerdsen, Reuven Levinson, J Webster Stayman

    A Multiple Aperture Device (MAD) is a novel x-ray beam modulator that uses binary filtration on a fine scale to spatially modulate an x-ray beam. Using two MADs in series enables a large variety of fluence profiles by shifting the MADS relative to each other. This work details the design and control of dual MADs for a specific class of desired fluence patterns. Specifically, models of MAD operation are integrated into a best fit objective followed by CMA-ES optimization. To illustrate this framework we demonstrate the design process for an abdominal phantom with the goal of uniform detected signal. Achievable fluence profiles show good agreement with target fluence profiles, and the ability to flatten projections when a phantom is scanned is demonstrated. Simulated data reconstruction using traditional tube current modulation (TCM) and MAD filtering with TCM are investigated with the dual MAD system demonstrating more uniformity in noise and illustrating the potential for dose reduction under a maximum noise level constraint.


    • 1 July 2016
      • Vol. 2016, 463-466

    Modeling Shift-Variant X-Ray Focal Spot Blur for High-Resolution Flat-Panel Cone-Beam CT.

    by Steven Tilley, Wojciech Zbijewski, Jeffrey H Siewerdsen, J Webster Stayman

    Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We present a shift-variant focal-spot blur model and incorporate it into a model-based iterative-reconstruction algorithm. We apply this algorithm to simulation and CBCT test-bench data. In a trabecular bone simulation study, we find traditional reconstruction approaches without a blur model exhibit shift-variant resolution properties that depend greatly on the acquisition protocol (e.g. short vs. full scans) and the anode angles of the rays used to reconstruct a particular region. For physical CBCT experiments focal spot blur was characterized and a spatial resolution phantom was scanned and reconstructed. In both experiments image quality using the shift-variant model was significantly improved over approaches that modeled no blur or only a shift-invariant blur, suggesting a potential means to overcome traditional CBCT spatial resolution and system design limitations.