James Vernon Coe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
James Vernon Coe has a total of 193 co-authors. Here are the top co-authors by number of shared publications:
Kenneth R. Rodriguez
The Ohio State University Department of Chemistry 100 West 18th Avenue, Columbus, Ohio 43210-1173, USA
12 shared publicationsMarvin A. Malone
The Ohio State Univ. (United States)
11 shared publicationsShaun M. Williams
Department of Chemistry , The Ohio State University , Columbus, OH 43210-1173, USA
11 shared publications- Katherine E. Cilwa
Naval Medical Research Ctr. (United States)
10 shared publications Shannon Teeters-Kennedy
The Ohio State University
10 shared publicationsCharles L. Hitchcock
IR Medtek LLC Gahanna Ohio USA
8 shared publications
Latest Publications
- Open Access
- 2 February 2026
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 130 (6) , 1798-1809
IR Spectroscopy and Linear Support Vector Machine Analysis of Colorectal Liver Metastasis
The Colorectal Liver Metastasis (CLM) library contains 756,096 full range Fourier transform infrared (FTIR) microscope imaging spectra of 14 frozen tissue sections from 7 different consenting patients with liver metastasis of colorectal origin. A subset of 30 windows was defined in predominant tumor or nontumor regions for the training or testing of linear support vector machine (SVM) models. Since the number of consenting patients was small, the primary purpose of this work was to establish a physical chemistry perspective on the infrared (IR) spectroscopy of metastatic liver cancer using the large number of available spectra. The linear SVM model was trained with a Leave-One-Case-Out strategy to avoid case leakage, minimize overtraining, and offer simple feature selection. The primary result is the derivation and measurement of a spectral form for the average contribution to the tumor/nontumor decision at each spectral step, i.e., the "Decision Contribution Spectrum". Finally, the results are used toward the design of a fast mid-IR cancer probe for the operating room giving quick tumor decisions despite a reduced range of wavenumbers and an increased interval between wavenumber steps as compared to the FTIR input spectral data.
- 2 February 2026
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 130 (6) , 1798-1809
Open AccessIR Spectroscopy and Linear Support Vector Machine Analysis of Colorectal Liver Metastasis
The Colorectal Liver Metastasis (CLM) library contains 756,096 full range Fourier transform infrared (FTIR) microscope imaging spectra of 14 frozen tissue sections from 7 different consenting patients with liver metastasis of colorectal origin. A subset of 30 windows was defined in predominant tumor or nontumor regions for the training or testing of linear support vector machine (SVM) models. Since the number of consenting patients was small, the primary purpose of this work was to establish a physical chemistry perspective on the infrared (IR) spectroscopy of metastatic liver cancer using the large number of available spectra. The linear SVM model was trained with a Leave-One-Case-Out strategy to avoid case leakage, minimize overtraining, and offer simple feature selection. The primary result is the derivation and measurement of a spectral form for the average contribution to the tumor/nontumor decision at each spectral step, i.e., the "Decision Contribution Spectrum". Finally, the results are used toward the design of a fast mid-IR cancer probe for the operating room giving quick tumor decisions despite a reduced range of wavenumbers and an increased interval between wavenumber steps as compared to the FTIR input spectral data.
- Open Access
- 15 January 2026
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (1) , e70226
Ex Vivo Assessment of Keratinocytic Carcinomas Using a Fast Mid‐Infrared Probe
A fast mid‐infrared spectral probe was used to record infrared (IR) spectra of fresh skin tissue removed from patients with biopsy‐proven keratinocytic cancer (KC) during Mohs surgery. A 150‐patient library of IR spectral data was obtained to see if KC on the epidermal side (outside) of tissue samples can be differentiated from adjacent nonmalignant tissue and normal skin. A linear support vector machine model minimized overtraining predicting the contributions to decisions at each step in the spectrum. Training with an equal cost for KC and nontumor cases samples demonstrated a KC sensitivity of 93% ± 5% and specificity 82% ± 6% (threefold testing esd) on the full library. Success in this test problem warrants future studies to see if differentiation of melanoma from benign melanocytic as well as other skin lesions is possible on live skin. This study was approved by the Advarra Institutional Review Board, #PRO00053468.
- 15 January 2026
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (1) , e70226
Open AccessEx Vivo Assessment of Keratinocytic Carcinomas Using a Fast Mid‐Infrared Probe
A fast mid‐infrared spectral probe was used to record infrared (IR) spectra of fresh skin tissue removed from patients with biopsy‐proven keratinocytic cancer (KC) during Mohs surgery. A 150‐patient library of IR spectral data was obtained to see if KC on the epidermal side (outside) of tissue samples can be differentiated from adjacent nonmalignant tissue and normal skin. A linear support vector machine model minimized overtraining predicting the contributions to decisions at each step in the spectrum. Training with an equal cost for KC and nontumor cases samples demonstrated a KC sensitivity of 93% ± 5% and specificity 82% ± 6% (threefold testing esd) on the full library. Success in this test problem warrants future studies to see if differentiation of melanoma from benign melanocytic as well as other skin lesions is possible on live skin. This study was approved by the Advarra Institutional Review Board, #PRO00053468.
- Open Access
- 17 December 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (51) , 63573-63582
Linear Support Vector Machine Model of an IR Spectral Library: Application to Skin Cancer
The primary result of this work is the derivation and measurement of the average “Decision Contribution Spectrum” using a mouse tumor sample data set and the linear support vector machine (SVM) method from a perspective of spectroscopy. The “Decision Contribution Spectrum” gives the average contribution to the decision (tumor/nontumor in this case) at each step along the spectrum. A library of more than four thousand infrared (IR) spectra was obtained with a Fourier Transform Infrared (FTIR) microscope imaging system on a frozen section of an SKH1 mouse tumor - an accepted murine model for studying squamous cell carcinoma in that it very closely recapitulates the human disease. A linear SVM model was trained and tested avoiding overtraining and offering simple feature selection. It was used to see how much data can be removed without affecting the quality of decisions. Then, two further efforts are described to move IR spectroscopy toward future use in human skin cancer detection: (i) the design of a reduced range and reduced sampling for a fast and hand-held, mid-infrared spectral probe, and (ii) the use of a fiber-loop sensor probe (with FTIR in this preliminary study) on live SKH1 mice that had tumors to detect cancer externally and show no ill effects on the mice. The combination of the latter efforts supports the feasibility of using a fiber-loop sensor with a fast and hand-held mid-infrared spectral probe for the detection of skin cancer on humans. This work does not demonstrate a working human skin cancer probe, rather it provides evidence for judging whether work on live human skin is justified.
- 17 December 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (51) , 63573-63582
Open AccessLinear Support Vector Machine Model of an IR Spectral Library: Application to Skin Cancer
The primary result of this work is the derivation and measurement of the average “Decision Contribution Spectrum” using a mouse tumor sample data set and the linear support vector machine (SVM) method from a perspective of spectroscopy. The “Decision Contribution Spectrum” gives the average contribution to the decision (tumor/nontumor in this case) at each step along the spectrum. A library of more than four thousand infrared (IR) spectra was obtained with a Fourier Transform Infrared (FTIR) microscope imaging system on a frozen section of an SKH1 mouse tumor - an accepted murine model for studying squamous cell carcinoma in that it very closely recapitulates the human disease. A linear SVM model was trained and tested avoiding overtraining and offering simple feature selection. It was used to see how much data can be removed without affecting the quality of decisions. Then, two further efforts are described to move IR spectroscopy toward future use in human skin cancer detection: (i) the design of a reduced range and reduced sampling for a fast and hand-held, mid-infrared spectral probe, and (ii) the use of a fiber-loop sensor probe (with FTIR in this preliminary study) on live SKH1 mice that had tumors to detect cancer externally and show no ill effects on the mice. The combination of the latter efforts supports the feasibility of using a fiber-loop sensor with a fast and hand-held mid-infrared spectral probe for the detection of skin cancer on humans. This work does not demonstrate a working human skin cancer probe, rather it provides evidence for judging whether work on live human skin is justified.
- Open Access
- 4 November 2025
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (3) , e202500311
Fast Mid‐Infrared Spectral Probe Decisions Match H&E Stain Results for Keratinocytic Carcinoma
We designed a handheld and fast mid‐infrared fiber‐optic spectral probe using a quantum cascade laser (QCL) and a reduced range of wavelengths, to see if keratinocytic carcinoma (KC) could be distinguished from adjacent nonmalignant tissue using discarded skin tissues from Mohs surgery. This study employed two adjacent frozen sections of discarded tissue: one was stained with H&E (the gold standard for skin cancer diagnosis) to identify the location of cancer by a pathologist, while the other was left unstained for mid‐infrared spectral probing on and off cancer as guided by the adjacent H&E stain. A total of 346 spectra from 18 consenting patients were collected during Mohs surgery. After adding a dehumidifier, an accuracy of 95% was obtained on a case sample basis. It will be worthwhile to assess the probe's utility at the surface of live human skin (study approved by the Advarra Institutional Review Board [PRO00044823]).
- 4 November 2025
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (3) , e202500311
Open AccessFast Mid‐Infrared Spectral Probe Decisions Match H&E Stain Results for Keratinocytic Carcinoma
We designed a handheld and fast mid‐infrared fiber‐optic spectral probe using a quantum cascade laser (QCL) and a reduced range of wavelengths, to see if keratinocytic carcinoma (KC) could be distinguished from adjacent nonmalignant tissue using discarded skin tissues from Mohs surgery. This study employed two adjacent frozen sections of discarded tissue: one was stained with H&E (the gold standard for skin cancer diagnosis) to identify the location of cancer by a pathologist, while the other was left unstained for mid‐infrared spectral probing on and off cancer as guided by the adjacent H&E stain. A total of 346 spectra from 18 consenting patients were collected during Mohs surgery. After adding a dehumidifier, an accuracy of 95% was obtained on a case sample basis. It will be worthwhile to assess the probe's utility at the surface of live human skin (study approved by the Advarra Institutional Review Board [PRO00044823]).
- Open Access
- 31 October 2025
- Published by Wiley
Title Ex Vivo Assessment of Keratinocytic Carcinomas Using a Fast Mid-Infrared Probe
A fast mid-infrared spectral probe was used to record infrared (IR) spectra of fresh skin tissue removed from patients with biopsy-proven Keratinocytic cancer (KC) during Mohs surgery. A 150-patient library of IR spectral data was obtained to see if KC can be differentiated from adjacent nonmalignant tissue and normal skin. A linear Support Vector Machine model was found to minimize overtraining and predict the contributions to decisions at each step in the spectrum. Training demonstrated a KC Sensitivity of 93±5% and Specificity 84±6% (3-fold Testing esd) on the full library using equal cost for KC and nontumor cases. Success in this test problem warrants future studies to see if differentiation of melanoma from benign melanocytic as well as other skin lesions is possible. This study was approved by the Advarra Institutional Review Board, #PRO00053468.
- 31 October 2025
- Published by Wiley
Open AccessTitle Ex Vivo Assessment of Keratinocytic Carcinomas Using a Fast Mid-Infrared Probe
A fast mid-infrared spectral probe was used to record infrared (IR) spectra of fresh skin tissue removed from patients with biopsy-proven Keratinocytic cancer (KC) during Mohs surgery. A 150-patient library of IR spectral data was obtained to see if KC can be differentiated from adjacent nonmalignant tissue and normal skin. A linear Support Vector Machine model was found to minimize overtraining and predict the contributions to decisions at each step in the spectrum. Training demonstrated a KC Sensitivity of 93±5% and Specificity 84±6% (3-fold Testing esd) on the full library using equal cost for KC and nontumor cases. Success in this test problem warrants future studies to see if differentiation of melanoma from benign melanocytic as well as other skin lesions is possible. This study was approved by the Advarra Institutional Review Board, #PRO00053468.
- 14 July 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 127 (29) , 6516-6531
Etalon-Assisted Study of the Strong CO Ligand Vibrations of the fac-[Re(CO)3(bpy)(CH3CN)]+ Octahedral Complex
The strong CO ligand vibrations ofan octahedral complex, fac-[Re (CO)(3)(bpy)(CH3CN)](+), in acetonitrile are observed at 2040 and1932 cm(-1). Facial rhenium tricarbonyl systems offervery strong and isolatedCO vibrations with the potential for interactions between these vibrations.This work first identifies the dominant ion-pair species using attenuatedtotal reflection infrared (ATR-IR) absorption spectra on a dilutionseries and then determines the strength of these CO ligand vibrations(as isolated vibrations) with a combination of ATR-IR and etalon-basedmeasurements that determine the absolute complex index of refractionof the solution. Finally, the etalon experiments are modeled to studythe interaction between vibrations, which is a property not embeddedin the solution's complex index of refraction. The ATR-IR spectraare accomplished on a dilution series as well as a larger set of spectraas these solutions evaporated. The A & PRIME;(1) CO ligand band at2040 cm(-1) is fit with a sum of three Lorentzianfunctions characterizing the distribution of free, solvent-separated,and contact ion pairs of this octahedral complex vs concentration. The other CO ligand band at 1932 cm(-1) is broader and complicated by the dynamics of vibrational interactions,the unresolved splitting of the A & PRIME;(2) and A & DPRIME; CO vibrations,and ion-pair speciation. The etalon transmission measurements vs angle were on a 0.029 M solution, and Rabi splittingsof 19 and 38 cm(-1) were observed for the A & PRIME;(1)CO vibration and the unresolved A & PRIME;(2) + A & DPRIME; CO vibrations,respectively. The great strength of the CO ligand vibrations is evidentdespite the use of a dilute solution. Integrated band intensitiesare reported in comparison to hybrid density functional calculationsfor isolated vibrations. Then, the observed Rabi splittings are modeledto obtain the coupling strength of the CO ligand vibration with etaloncavity modes and with each other. In summary, this work develops amethod to determine the concentration of these solutions from theATR-IR spectrum, characterizes the ion-pairing, shows that the indexof refraction is not constant in the IR spectral region of interest,and develops an interaction Hamiltonian that characterizes cavity-vibrationand vibration-vibration coupling.
- 14 July 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 127 (29) , 6516-6531
Etalon-Assisted Study of the Strong CO Ligand Vibrations of the fac-[Re(CO)3(bpy)(CH3CN)]+ Octahedral Complex
The strong CO ligand vibrations ofan octahedral complex, fac-[Re (CO)(3)(bpy)(CH3CN)](+), in acetonitrile are observed at 2040 and1932 cm(-1). Facial rhenium tricarbonyl systems offervery strong and isolatedCO vibrations with the potential for interactions between these vibrations.This work first identifies the dominant ion-pair species using attenuatedtotal reflection infrared (ATR-IR) absorption spectra on a dilutionseries and then determines the strength of these CO ligand vibrations(as isolated vibrations) with a combination of ATR-IR and etalon-basedmeasurements that determine the absolute complex index of refractionof the solution. Finally, the etalon experiments are modeled to studythe interaction between vibrations, which is a property not embeddedin the solution's complex index of refraction. The ATR-IR spectraare accomplished on a dilution series as well as a larger set of spectraas these solutions evaporated. The A & PRIME;(1) CO ligand band at2040 cm(-1) is fit with a sum of three Lorentzianfunctions characterizing the distribution of free, solvent-separated,and contact ion pairs of this octahedral complex vs concentration. The other CO ligand band at 1932 cm(-1) is broader and complicated by the dynamics of vibrational interactions,the unresolved splitting of the A & PRIME;(2) and A & DPRIME; CO vibrations,and ion-pair speciation. The etalon transmission measurements vs angle were on a 0.029 M solution, and Rabi splittingsof 19 and 38 cm(-1) were observed for the A & PRIME;(1)CO vibration and the unresolved A & PRIME;(2) + A & DPRIME; CO vibrations,respectively. The great strength of the CO ligand vibrations is evidentdespite the use of a dilute solution. Integrated band intensitiesare reported in comparison to hybrid density functional calculationsfor isolated vibrations. Then, the observed Rabi splittings are modeledto obtain the coupling strength of the CO ligand vibration with etaloncavity modes and with each other. In summary, this work develops amethod to determine the concentration of these solutions from theATR-IR spectrum, characterizes the ion-pairing, shows that the indexof refraction is not constant in the IR spectral region of interest,and develops an interaction Hamiltonian that characterizes cavity-vibrationand vibration-vibration coupling.
- 25 January 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 127 (4) , 980-995
Etalon-Assisted Determination of the Complex Index of Refraction of a Solution for the Study of Strong Cavity–Vibrational Coupling of PF6– in Acetonitrile
A new method is established using an etalon cavity to assist in the determination of the wavelength-dependent complex index of refraction of a solution throughout the mid-infrared range. The results are used to study the cavity-vibration polaritons of PF6- in acetonitrile. Mixed states are formed by placing solution inside a pair of parallel plate mirrors with a wavelength-scale spacing, i.e., within an etalon, such that there are cavity states that are angle-tuned into resonance with the strong P-F vibrations. The dominant ν3 vibrations of PF6- consist of nearly triply degenerate oscillations of the partial-positively charged phosphorous against antisymmetric concerted motions of different sets of fluorine atoms with partial negative charges. These vibrations are dominant even though the solute is 29 times less concentrated than the solvent on a molar basis. The first part of the paper describes the method of determining the complex index of refraction of the solution from a combination of etalon transmission maxima and the attenuated total reflection (ATR) absorption spectrum of the solution. The results are presented as an analytical function including a sum of 37 vibrational contributions. Absolute integrated isolated band intensities were determined to be 463 ± 4, 462 ± 7, and 266 ± 4 km/mol for the three ν3 PF6- vibrations at 841.4, 847.4, and 854.0 cm-1, respectively, which sum to 1191 ± 9 km/mol for the ν3 band. Then, the results are used to simulate the measured etalon transmission using the transfer matrix (TM) method with and without the ν3 target vibrations. The etalon transmission simulations reconstruct the position of cavity modes in the absence of target vibrations. They provide input data for the testing of simple quantum mechanical models for the interaction of vibrations with cavity modes and the interactions of vibrations with other vibrations within the molecule and between solute and solvent. The model shows that the nearly degenerate ν3 vibrations interact with each other with a vibration-vibration coupling of 33 ± 5 cm-1. This is comparable to the cavity-vibration coupling of 30.4 ± 2.9 cm-1 of the two strongest vibrations of PF6-.
- 25 January 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 127 (4) , 980-995
Etalon-Assisted Determination of the Complex Index of Refraction of a Solution for the Study of Strong Cavity–Vibrational Coupling of PF6– in Acetonitrile
A new method is established using an etalon cavity to assist in the determination of the wavelength-dependent complex index of refraction of a solution throughout the mid-infrared range. The results are used to study the cavity-vibration polaritons of PF6- in acetonitrile. Mixed states are formed by placing solution inside a pair of parallel plate mirrors with a wavelength-scale spacing, i.e., within an etalon, such that there are cavity states that are angle-tuned into resonance with the strong P-F vibrations. The dominant ν3 vibrations of PF6- consist of nearly triply degenerate oscillations of the partial-positively charged phosphorous against antisymmetric concerted motions of different sets of fluorine atoms with partial negative charges. These vibrations are dominant even though the solute is 29 times less concentrated than the solvent on a molar basis. The first part of the paper describes the method of determining the complex index of refraction of the solution from a combination of etalon transmission maxima and the attenuated total reflection (ATR) absorption spectrum of the solution. The results are presented as an analytical function including a sum of 37 vibrational contributions. Absolute integrated isolated band intensities were determined to be 463 ± 4, 462 ± 7, and 266 ± 4 km/mol for the three ν3 PF6- vibrations at 841.4, 847.4, and 854.0 cm-1, respectively, which sum to 1191 ± 9 km/mol for the ν3 band. Then, the results are used to simulate the measured etalon transmission using the transfer matrix (TM) method with and without the ν3 target vibrations. The etalon transmission simulations reconstruct the position of cavity modes in the absence of target vibrations. They provide input data for the testing of simple quantum mechanical models for the interaction of vibrations with cavity modes and the interactions of vibrations with other vibrations within the molecule and between solute and solvent. The model shows that the nearly degenerate ν3 vibrations interact with each other with a vibration-vibration coupling of 33 ± 5 cm-1. This is comparable to the cavity-vibration coupling of 30.4 ± 2.9 cm-1 of the two strongest vibrations of PF6-.
- 28 January 2022
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 156 (4) , 044508
Effective mass of cavity-vibration polaritons formed in etalons with liquid carbon tetrachloride
Etalons are pairs of parallel plate mirrors with wavelength-scale spacing that exhibit cavity modes, giving transmission maxima (fringes) due to constructive interference. Infrared transmission measurements as a function of angle were used to determine the effective mass of etalon cavity modes using a gap filled with air and then liquid carbon tetrachloride. The air-filled etalon gives results in agreement with pure photon expectations established herein. Liquids with vibrations having strong infrared transition intensity (vibrational strong coupling mode) can strongly perturb the pattern of transmission resonances, creating mixed states of infrared cavity modes and molecular vibrations, i.e., cavity-vibration polaritons. The effective mass of one cavity-vibration polariton close to the strong vibration of carbon tetrachloride is 4.36 times heavier than the pure photon cavity mode expectation, i.e., the mass factor vs pure light. The mass factors are largest when closest to the strong vibrational frequency, and they converge to the one far away from the strong vibration. This work gives quantitative values of the effective mass of cavity-vibration polariton states and is a diagnostic for the mixing of vibrations with etalon transmission.
- 28 January 2022
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 156 (4) , 044508
Effective mass of cavity-vibration polaritons formed in etalons with liquid carbon tetrachloride
Etalons are pairs of parallel plate mirrors with wavelength-scale spacing that exhibit cavity modes, giving transmission maxima (fringes) due to constructive interference. Infrared transmission measurements as a function of angle were used to determine the effective mass of etalon cavity modes using a gap filled with air and then liquid carbon tetrachloride. The air-filled etalon gives results in agreement with pure photon expectations established herein. Liquids with vibrations having strong infrared transition intensity (vibrational strong coupling mode) can strongly perturb the pattern of transmission resonances, creating mixed states of infrared cavity modes and molecular vibrations, i.e., cavity-vibration polaritons. The effective mass of one cavity-vibration polariton close to the strong vibration of carbon tetrachloride is 4.36 times heavier than the pure photon cavity mode expectation, i.e., the mass factor vs pure light. The mass factors are largest when closest to the strong vibrational frequency, and they converge to the one far away from the strong vibration. This work gives quantitative values of the effective mass of cavity-vibration polariton states and is a diagnostic for the mixing of vibrations with etalon transmission.
- 26 July 2021
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 125 (30) , 8472-8483
Changing Vibration Coupling Strengths of Liquid Acetonitrile with an Angle-Tuned Etalon
This work is the first report on nonzero molecular vibration–vibration coupling in an infrared cavity–vibration experiment. Vibration–vibration coupling strength is determined as a cavity mode of parallel spaced mirrors (etalon mode or fringe) is angle-tuned in the region between two vibrations of liquid acetonitrile which are Fermi coupled, namely, a CN stretch dominated vibration and a nearby combination band dominated by the symmetric CH3 bend and C–C stretch. All other infrared cavity–vibration work to date involving more than one vibration has used a value of zero for vibration–vibration coupling; however, this work starts with Fermi coupled vibrations and reveals that there are changes in the vibration–vibration coupling and cavity–vibration couplings as the cavity mode is angle-tuned between the interacting vibrations. The ability to change fundamental vibrational dynamics within a cavity is an exciting result which helps to build a foundation for understanding molecular vibrational dynamics in parallel plate etalon cavities.
- 26 July 2021
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 125 (30) , 8472-8483
Changing Vibration Coupling Strengths of Liquid Acetonitrile with an Angle-Tuned Etalon
This work is the first report on nonzero molecular vibration–vibration coupling in an infrared cavity–vibration experiment. Vibration–vibration coupling strength is determined as a cavity mode of parallel spaced mirrors (etalon mode or fringe) is angle-tuned in the region between two vibrations of liquid acetonitrile which are Fermi coupled, namely, a CN stretch dominated vibration and a nearby combination band dominated by the symmetric CH3 bend and C–C stretch. All other infrared cavity–vibration work to date involving more than one vibration has used a value of zero for vibration–vibration coupling; however, this work starts with Fermi coupled vibrations and reveals that there are changes in the vibration–vibration coupling and cavity–vibration couplings as the cavity mode is angle-tuned between the interacting vibrations. The ability to change fundamental vibrational dynamics within a cavity is an exciting result which helps to build a foundation for understanding molecular vibrational dynamics in parallel plate etalon cavities.
- 15 January 2019
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 123 (6) , 1302-1306
Effect of Strongly Coupled Vibration–Cavity Polaritons on the Bulk Vibrational States within a Wavelength-Scale Cavity
A Rabi splitting of 43.0 ± 1.0 cm-1 (95 % conf.) was determined for the interaction of the CD3 deformation, the strongest fundamental vibration of the liquid CD3C≡N molecule, and fringe modes of a parallel plate Fabry-Pérot cavity containing this liquid. Note that vibration-cavity polaritons are also called dressed states, hybrid or mixed states. Since the experimental configuration has many orders of magnitude more vibrational oscillators than photons, vibrational oscillators not in dressed states far outnumber the dressed states. This work is distinguished from related vibration-cavity work by a method to extract the position, width, phase, and intensity of bulk vibrational signals including reconstruction of the position of the fringe without vibrational contributions. It reveals how the bulk vibrational oscillators are changed by interaction within the cavity even though they are not in dressed states. While the dressed states are obvious targets for manipulation of chemical response, it is interesting to consider whether the lesser but more prevalent changes of the bulk vibrations can also be used to change chemical response.
- 15 January 2019
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 123 (6) , 1302-1306
Effect of Strongly Coupled Vibration–Cavity Polaritons on the Bulk Vibrational States within a Wavelength-Scale Cavity
A Rabi splitting of 43.0 ± 1.0 cm-1 (95 % conf.) was determined for the interaction of the CD3 deformation, the strongest fundamental vibration of the liquid CD3C≡N molecule, and fringe modes of a parallel plate Fabry-Pérot cavity containing this liquid. Note that vibration-cavity polaritons are also called dressed states, hybrid or mixed states. Since the experimental configuration has many orders of magnitude more vibrational oscillators than photons, vibrational oscillators not in dressed states far outnumber the dressed states. This work is distinguished from related vibration-cavity work by a method to extract the position, width, phase, and intensity of bulk vibrational signals including reconstruction of the position of the fringe without vibrational contributions. It reveals how the bulk vibrational oscillators are changed by interaction within the cavity even though they are not in dressed states. While the dressed states are obvious targets for manipulation of chemical response, it is interesting to consider whether the lesser but more prevalent changes of the bulk vibrations can also be used to change chemical response.