TMTinashe Mutsvangwa

Tinashe Mutsvangwa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tinashe Mutsvangwa has a total of 94 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Landmark-Constrained Multi-Object Model Fitting. An Application for 3D Reconstruction of X-Ray Images of the Human Foot

    by Catherine Namayega, Tinashe Em Mutsvangwa, Bernhard Egger, Bhushan Borotikar, Lindie Du Plessis

    In developing countries, two-dimensional (2D) Xrays are widely used in radiology due to their cost-effectiveness, accessibility, and lower radiation exposure compared to three-dimensional (3D) computed tomography (CT) scans. Despite the challenges in interpreting 3D anatomy from 2D images, these methods remain crucial in resource-limited settings. To improve diagnostic capabilities, techniques have been developed to reconstruct 3D images from 2D X-rays, utilising data-efficient and explainable model-to-modality approaches. This study presents simulation of landmark-constrained model fitting steps for 3D reconstruction of complex anatomy using a multi-object statistical shape, pose, and intensity model (SSPIM) and bi-planar digitally reconstructed radiographs (DRRs) forming the model-to-modality approach for clinical adoption. The resulting mean error from the 3D coordinate point reconstruction was 0.28 millimetres (mm) for calibration frame control points, 2.82 and 4.18 mm for the reconstruction of anatomical landmarks of the SSPIM sample and foot CT image, respectively. The average distances obtained from fitting the multi-object SSPIM to the SSPIM sample and the foot CT image anatomical landmarks were 0.32 and 1.94 mm, and 1.94 and 2.54 mm for the 12 ground-truth anatomical landmarks and the 12 reprojected landmarks, respectively. Although the results of this study indicate that there is still a need to improve the 3D-2D algorithm, it also confirms the capability and feasibility of reconstructing complex anatomy from X-rays using 2D landmarks and statistical models. The use of this pipeline potentially offers a cost-effective and clinically useful solution to improve diagnostic accuracy with available low-cost imaging, especially in underserved regions.

  • Hyperspectral Imaging for the Diagnosis of Latent Tuberculosis Infection

    by Ajibola S. Oladokun, Bessie Malila, Muki Shey, Tinashe Mutsvangwa

  • Capturing Complexity of the Foot Arch Bones: Evaluation of a Statistical Modelling Framework for Learning Shape, Pose and Intensity Features in a Continuous Domain

    by Catherine Namayega, Bhushan Borotikar, Martin Menten, Victoria Gibbon, Xolisile Thusini, Bernhard Egger, Arne Burssens, Emmanuel Audenaert, Tinashe E. M. Mutsvangwa


  • Bridging the Gap: Generalising State-of-the-Art U-Net Models to Sub-Saharan African Populations

    by Alyssa R. Amod, Alexandra Smith, Pearly Joubert, Confidence Raymond, Dong Zhang, Udunna C. Anazodo, Dodzi Motchon, Tinashe E. M. Mutsvangwa, Sébastien Quetin


  • Open Access

    Automated analysis of digital medical images in cervical cancer screening: A systematic review

    by Leshego Ledwaba, Rakiya Saidu, Bessie Malila, Louise Kuhn, Tinashe E.M. Mutsvangwa

    Background Cervical cancer screening programs are poorly implemented in LMICs due to a shortage of specialists and expensive diagnostic infrastructure. To address the barriers of implementation researchers have been developing low-cost portable devices and automating image analysis for decision support. However, as the knowledge base is growing rapidly, progress on the implementation status of novel imaging devices and algorithms in cervical cancer screening has become unclear. The aim of this project was to provide a systematic review summarizing the full range of automated technology systems used in cervical cancer screening. Method A search on academic databases was conducted and the search results were screened by two independent reviewers. Study selection was based on eligibility in meeting the terms of inclusion and exclusion criteria which were outlined using a Population, Intervention, Comparator and Outcome framework. Results 17 studies reported algorithms developed with source images from mobile device, viz. Pocket Colposcope, MobileODT EVA Colpo, Smartphone Camera, Smartphone-based Endoscope System, Smartscope, mHRME, and PiHRME. While 56 studies reported algorithms with source images from conventional/commercial acquisition devices. Most interventions were in the feasibility stage of development, undergoing initial clinical validations. Conclusion Researchers have proven superior prediction performance of computer aided diagnostics (CAD) in colposcopy (>80% accuracies) versus manual analysis (<70.0% accuracies). Furthermore, this review summarized evidence of the algorithms which are being created utilizing portable devices, to circumvent constraints prohibiting wider implementation in LMICs (such as expensive diagnostic infrastructure). However clinical validation of novel devices with CAD is not yet implemented adequately in LMICs.

  • Open Access

    Evaluating 3D human face reconstruction from a frontal 2D image, focusing on facial regions associated with foetal alcohol syndrome

    by Felix Atuhaire, Bernhard Egger, Tinashe Mutsvangwa

    Foetal alcohol syndrome (FAS) is a preventable condition caused by maternal alcohol consumption during pregnancy. The FAS facial phenotype is an important factor for diagnosis, alongside central nervous system impairments and growth abnormalities. Current methods for analysing the FAS facial phenotype rely on 3D facial image data, obtained from costly and complex surface scanning devices. An alternative is to use 2D images, which are easy to acquire with a digital camera or smart phone. However, 2D images lack the geometric accuracy required for accurate facial shape analysis. Our research offers a solution through the reconstruction of 3D human faces from single or multiple 2D images. We have developed a framework for evaluating 3D human face reconstruction from a single-input 2D image using a 3D face model for potential use in FAS assessment. We first built a generative morphable model of the face from a database of registered 3D face scans with diverse skin tones. Then we applied this model to reconstruct 3D face surfaces from single frontal images using a model-driven sampling algorithm. The accuracy of the predicted 3D face shapes was evaluated in terms of surface reconstruction error and the accuracy of FAS-relevant landmark locations and distances. Results show an average root mean square error of 2.62 mm. Our framework has the potential to estimate 3D landmark positions for parts of the face associated with the FAS facial phenotype. Future work aims to improve on the accuracy and adapt the approach for use in clinical settings. Significance: Our study presents a framework for constructing and evaluating a 3D face model from 2D face scans and evaluating the accuracy of 3D face shape predictions from single images. The results indicate low generalisation error and comparability to other studies. The reconstructions also provide insight into specific regions of the face relevant to FAS diagnosis. The proposed approach presents a potential cost-effective and easily accessible imaging tool for FAS screening, yet its clinical application needs further research.


  • Dynamic multi feature-class Gaussian process models

    by Jean-Rassaire Fouefack, Bhushan Borotikar, Marcel Lüthi, Tania S. Douglas, Valérie Burdin, Tinashe E.M. Mutsvangwa


  • Reconstruction of the mandible from partial inputs for virtual surgery planning

    by Ryan L. Gillingham, Tinashe E.M. Mutsvangwa, Johan van der Merwe

    Statistical Shape Models (SSMs) and Sparse Prediction Models (SPMs) based on regressions between cephalometric measurements were compared against standard practice in virtual surgery planning for reconstruction of mandibular defects. Emphasis was placed on the ability of the models to reproduce clinically relevant metrics. CT scans of 50 men and 50 women were collected and split into training and testing datasets according to an 80:20 ratio. The scans were segmented, and anatomical landmarks were identified. SPMs were constructed based on direct regressions between measurements derived from the anatomical landmarks. SSMs were developed by establishing correspondence between the segmented meshes, performing alignment, and principal component analysis. Anterior and bilateral defects were simulated by removing sections of the mandibles in the testing set. Measurement errors after reconstruction ranged from 1.07˚ to 2.2˚ and 0.66 mm to 2.02 mm for mirroring, from 0.45˚ to 3.67˚ and 0.66 mm to 2.54 mm for the SSMs, and from 1.74˚ to 5.01˚ and 0.64 mm to 2.89 mm for the SPMs. Surface-to-surface errors ranged from 1.01 mm to 1.29 mm and 1.06 mm to 1.33 mm for mirroring and SSMs, respectively. Based on the results, SSMs are recommended for VSP in the absence of normal patient anatomy.


  • Dynamic Multi-object Gaussian Process Models

    by Jean-Rassaire Fouefack, Bhushan Borotikar, Tania S. Douglas, Valérie Burdin, Tinashe E. M. Mutsvangwa


  • A Gaussian Process Model Based Generative Framework for Data Augmentation of Multi-modal 3D Image Volumes

    by Nicolas H. Nbonsou Tegang, Jean-Rassaire Fouefack, Bhushan Borotikar, Valérie Burdin, Tania S. Douglas, Tinashe E. M. Mutsvangwa