FXFeng Xiong

Feng Xiong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Feng Xiong has a total of 278 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Artificial synapse with tunable dynamic range for neuromorphic computing with ion intercalated bilayer graphene

    by Yuzhi He, Purun (Simon) Cao, Shahin Hashemkhani, Yihan Liu, Daniel Vaz, Keya Joy, Nathan Youngblood, Rajkumar Kubendran, M. P. Anantram, Feng Xiong


  • A CMOS‐Compatible Protonic Memristor Made from H‐Graphene/ZrO2/HxWO3 Stacks with Asymmetrical Proton Concentration

    by Yihan Liu, Yuzhi He, Feng Xiong

    Protonic memristor has recently garnered extensive research interest as one of the most promising memories for nonvolatile data storage and neuromorphic computing applications. However, the CMOS‐combability in protonic device fabrication and operating is difficult to achieve. In this study, a proton‐based H‐graphene/ZrO2/HxWO3 memristor device is demonstrated, which showcases resistive switching behavior in multiple operating environments such as vacuum, atmosphere, and high high‐humidity environment. The fabrication and operating processes are also CMOS‐compatible, enabling the integration of protonic memristors in Si‐based integrated circuits. Multistate resistive switching is demonstrated by a short writing voltage pulse (1–20 µs in pulse width) enabled by the rapid diffusion speed of proton, which renders it a good candidate for applications in high‐speed nonvolatile memory and artificial synapse for persistent reverberatory neuromorphic system and fast pattern learning via spike‐rate‐dependent plasticity (SRDP) rule.


  • Open Access

    Artificial Synapse with Tunable Dynamic Range for Neuromorphic Computing with Ion Intercalated Bilayer Graphene

    by Yuzhi He, Purun (Simon) Cao, Shahin Hashemkhani, Yihan Liu, Daniel Vaz, Keya Joy, Nathan Youngblood, Rajkumar Kubendran, M. P. Anantram, Feng Xiong

    In neuromorphic computing, a tunable dynamic range in artificial synapses is crucial, as it allows devices to emulate the human brain's efficiency in processing complex information with analog programmable states. Here, we introduce an electrochemical random-access memory (ECRAM) based on bilayer graphene. Our device achieves a large and programmable dynamic range through lithium-ion (Li+) intercalation, pulse modulation, and geometric engineering. We systematically investigated how pulse parameters, including amplitude, duty cycle, frequency, and signal type, affect conductance and dynamic range. Our results demonstrate that higher pulse amplitudes and/or longer duty cycles enhance Li+ intercalation efficiency; while lower frequencies pulse trains facilitate ion intercalation, significantly influencing conductance and dynamic range. Additionally, we explored how geometric factors such as channel length in bilayer and multi-layer graphene and the introduction of hole structures may affect intercalation kinetics and subsequently device performance. First-principles density functional theory (DFT) calculations were also performed to support that the interlayer space in bilayer graphene is energetically favorable for Li transport, and that hole structures promote efficient Li intercalation by providing barrierless pathways through the exposed edges of the bilayer. These findings confirm bilayer graphene as a promising material for developing high-performance artificial synapses with tunable characteristics.

  • Highly aligned electroactive ultrafine fibers promote the differentiation of mesenchymal stem cells into Schwann-like cells for nerve regeneration

    by Shuo Wei, Feng Xiong, Haonan Gu, Zhuojun Zhang, Hongyun Xuan, Yan Jin, Ye Xue, Biyun Li, Wei Feng, Huihua Yuan


  • Open Access

    Thermoelectric active cooling for transient hot spots in microprocessors

    by Yihan Liu, Hao-Yuan Cheng, Jonathan A. Malen, Feng Xiong

    Modern microprocessor performance is limited by local hot spots induced at high frequency by busy integrated circuit elements such as the clock generator. Locally embedded thermoelectric devices (TEDs) are proposed to perform active cooling whereby thermoelectric effects enhance passive cooling by the Fourier law in removing heat from the hot spot to colder regions. To mitigate transient heating events and improve temperature stability, we propose a novel analytical solution that describes the temperature response of a periodically heated hot spot that is actively cooled by a TED driven electrically at the same frequency. The analytical solution that we present is validated by experimental data from frequency domain thermal reflectance (FDTR) measurements made directly on an actively cooled Si thermoelectric device where the pump laser replicates the transient hot spot. We herein demonstrate a practical method to actively cancel the transient temperature variations on circuit elements with TEDs. This result opens a new path to optimize the design of cooling systems for transient localized hot spots in integrated circuits.


  • Open Access

    DNA-based doping and fabrication of PN diodes

    by Ruobing Bai, Yihan Liu, Bomin Zhang, Beishan Chen, Feng Xiong, Haitao Liu

    This paper reports the fabrication of silicon PN diode by using DNA nanostructure as the etching template for SiO2 and also as the n-dopant of Si. DNA nanotubes were deposited onto p-type silicon wafer that has a thermal SiO2 layer. The DNA nanotubes catalyze the etching of SiO2 by HF vapor to expose the underlying Si. The phosphate groups in the DNA nanotube were used as the doping source to locally n-dope the Si wafer to form vertical P-N junctions. Prototype PN diodes were fabricated and exhibited expected blockage behavior with a knee voltage of ca. 0.7 V. Our work highlights the potential of DNA nanotechnology in future fabrication of nanoelectronics.


  • Open Access

    Building Time-Surfaces by Exploiting the Complex Volatility of an ECRAM Memristor

    by Marco Rasetto, Qingzhou Wan, Himanshu Akolkar, Feng Xiong, Bertram Shi, Ryad Benosman

    Memristors have emerged as a promising technology for efficient neuromorphic architectures owing to their ability to act as programmable synapses, combining processing and memory into a single device. Although they are most commonly used for static encoding of synaptic weights, recent work has begun to investigate the use of their dynamical properties, such as Short Term Plasticity (STP), to integrate events over time in event-based architectures. However, we are still far from completely understanding the range of possible behaviors and how they might be exploited in neuromorphic computation. This work focuses on a newly developed LixWO3-based three-terminal memristor that exhibits tunable STP and a conductance response modeled by a double exponential decay. We derive a stochastic model of the device from experimental data and investigate how device stochasticity, STP, and the double exponential decay affect accuracy in a hierarchy of time-surfaces (HOTS) architecture. We found that the device’s stochasticity does not affect accuracy, that STP can reduce the effect of salt and pepper noise in signals from event-based sensors, and that the double exponential decay improves accuracy by integrating temporal information over multiple time scales. Our approach can be generalized to study other memristive devices to build a better understanding of how control over temporal dynamics can enable neuromorphic engineers to fine-tune devices and architectures to fit their problems at hand.


  • Toward Real‐Time Blood Pressure Monitoring via High‐Fidelity Iontronic Tonometric Sensors with High Sensitivity and Large Dynamic Ranges

    by Qingzhou Wan, Qian Chen, Mark A Freithaler, Sridhar Reddy Velagala, Yihan Liu, Albert C. To, Aman Mahajan, Ramakrishna Mukkamala, Feng Xiong

    Continuous, noninvasive blood pressure (CNIBP) monitoring provides valuable hemodynamic information that renders detection of the early onset of cardiovascular diseases. Wearable mechano‐electric pressure sensors that mount on the skin are promising candidates for monitoring continuous blood pressure (BP) pulse waveforms due to their excellent conformability, simple sensing mechanisms, and convenient signal acquisition. However, it is challenging to acquire high‐fidelity BP pulse waveforms since it requires highly sensitive sensors (sensitivity larger than 4 × 10−5 kPa−1) that respond linearly with pressure change over a large dynamic range, covering the typical BP range (5–25 kPa). Herein, this work introduces a high‐fidelity, iontronic‐based tonometric sensor (ITS) with high sensitivity (4.82 kPa−1), good linearity (R2 > 0.995), and a large dynamic range (up to 180% output change) over a broad working range (0 to 38 kPa). Additionally, the ITS demonstrates a low limit of detection at 40 Pa, a fast load response time (35 ms) and release time (35 ms), as well as a stable response over 5000 load per release cycles, paving ways for potential applications in human‐interface interaction, electronic skins, and robotic haptics. This work further explores the application of the ITS in monitoring real‐time, beat‐to‐beat BP by measuring the brachial and radial pulse waveforms. This work provides a rational design of a wearable pressure sensor with high sensitivity, good linearity, and a large dynamic range for real‐time CNIBP monitoring.


  • Open Access

    Long-term Pegylated GH for Children With GH Deficiency: A Large, Prospective, Real-world Study

    by Ling Hou, Ke Huang, Chunxiu Gong, Feihong Luo, Haiyan Wei, Liyang Liang, Hongwei Du, Jianping Zhang, Yan Zhong, Ruimin Chen, et al.

    Context The evidence of long-term polyethylene glycol recombinant human GH (PEG-rhGH) in pediatric GH deficiency (GHD) is limited. Objective This study aimed to examine the effectiveness and safety of long-term PEG-rhGH in children with GHD in the real world, as well as to examine the effects of dose on patient outcomes. Design A prospective, observational, posttrial study (NCT03290235). Setting, participants and intervention Children with GHD were enrolled from 81 centers in China in 4 individual clinical trials and received weekly 0.2 mg/kg/wk (high-dose) or 0.1 to P < 0.0001), with a mean change of 0.53 ± 0.30, 0.89 ± 0.48, 1.35 ± 0.63, 1.63 ± 0.75 at 6 months, 12 months, 24 months, and 36 months, respectively. In addition, the changes in Ht SDS from baseline were significantly improved in the high-dose subgroup compared with the low-dose subgroup at 6, 12, 24, and 36 months after treatment (all P < 0.05). A total of 12 (1.03%) patients developed serious adverse events. There was no serious adverse event related to the treatment, and no AEs leading to treatment discontinuation or death occurred. Conclusions PEG-rhGH showed long-term effectiveness and safety in treating children with GHD. Both dose subgroups showed promising outcomes, whereas PEG-rhGH 0.2 mg/kg/wk might show additional benefit.


  • Designing fast and efficient electrically driven phase change photonics using foundry compatible waveguide-integrated microheaters

    by John R. Erickson, Vivswan Shah, Qingzhou Wan, Nathan Youngblood, Feng Xiong

    Phase change chalcogenides such as Ge2Sb2Te5 (GST) have recently enabled advanced optical devices for applications such as in-memory computing, reflective displays, tunable metasurfaces, and reconfigurable photonics. However, designing phase change optical devices with reliable and efficient electrical control is challenging due to the requirements of both high amorphization temperatures and extremely fast quenching rates for reversible switching. Here, we use a Multiphysics simulation framework to model three waveguide-integrated microheaters designed to switch optical phase change materials. We explore the effects of geometry, doping, and electrical pulse parameters to optimize the switching speed and minimize energy consumption in these optical devices.