HHHyundoo Hwang

Hyundoo Hwang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hyundoo Hwang has a total of 162 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Leveraging Smart Ring Metrics to Tailor Nature-Based Physical Activities for Affective Improvement: The Moderating Role of Activity Volume, Duration, and Intensity (Preprint)

    by Sujin Seong, Hye Won Kim, Jina Kim, Hyundoo Hwang, Min-Sup Shin

    BACKGROUND Effective management of daily stress and improvement of affect require personalized approaches. Nature-based physical activity has emerged as a promising intervention; however, many previous studies have relied on single quantitative indicators such as daily step counts, leaving a critical gap in understanding for whom and at what dose nature-based walking most effectively improves affect. Studies utilizing objective multimodal data from smart rings to explore personalized optimal activity conditions remain limited. OBJECTIVE This study aimed to examine whether the effect of nature-based walking on affective improvement varies according to baseline perceived stress, and to investigate how smart ring-derived activity sub-dimensions—volume (total steps), duration, and intensity metrics (cadence and heart rate)—moderate this relationship. METHODS This observational study enrolled 100 adult participants (mean age 52.39 years, SD 12.69; 84 females) who performed at least 30 minutes of free-living walking in an outdoor garden while wearing the Chitaring smart ring (Bredis Healthcare Inc.). Four activity metrics were derived: total steps, walking duration, cadence (steps per minute, SPM), and mean heart rate (beats per minute, BPM). Affective states were assessed before and after activity using the Korean Positive and Negative Affect Schedule (PANAS). Exploratory factor analysis identified a three-factor structure: Negative Affect (NA), Positive Affect (PA), and a newly isolated factor, Cognitive Affect (CA). Baseline perceived stress was measured using the 10-item Perceived Stress Scale (PSS-10); participants were categorized into Low Stress (n=40) and Moderate-to-High Stress (n=60) groups. Pearson correlations and moderation analyses examined group-by-activity interactions on affective change scores (ΔPA, ΔNA, ΔCA). RESULTS Baseline perceived stress was significantly positively correlated with ΔPA (r=0.20, P=.042) and negatively correlated with ΔNA (r=−0.24, P=.016), indicating that higher-stress participants experienced greater increases in positive affect and larger reductions in negative affect following walking. For the Low Stress group, activity exceeding approximately 1,500 steps or 60 minutes was associated with attenuation of affective benefits (ΔPA: r=−0.33). A significant group-by-duration interaction was observed for ΔCA (P=.023), with the Low Stress group showing a strong negative association (r=−0.41), whereas the Moderate-to-High Stress group showed no meaningful association (r=−0.04). No significant group-by-SPM or group-by-BPM interactions were observed for any affective outcome. CONCLUSIONS Baseline perceived stress emerged as the primary moderator of affective benefits derived from nature-based walking. An affective inflection point was identified, suggesting that excessive activity in a low-stress state may diminish positive affective gains. These findings support a shift away from universal benchmarks (e.g., the 10,000-step goal) toward personalized prescriptions calibrated to an individual’s psychological baseline, providing a framework for Just-In-Time Adaptive Interventions in mobile health therapeutics.

  • Open Access

    Evaluation of Analytical Performances of Magnetic Force-Assisted Electrochemical Sandwich Immunoassay for the Quantification of Carcinoembryonic Antigen

    by Boo Young Hwang, Eunsoo Kim, Seung-Ha Kim, Hyundoo Hwang

    Carcinoembryonic antigen (CEA) is a biomarker indicated in different cancers, targeted for quantitative analysis via immunoassay. Here we introduce a new technique called magnetic force-assisted electrochemical sandwich immunoassay (MESIA) for determination of CEA level in a drop of human serum using a fully automated point-of-care testing (POCT) device. The analytical performances of the assay are assessed based on precision, accuracy, limit of blank (LoB), limit of detection (LoD) and limit of quantitation (LoQ), linearity, Hook effect, interference, cross-reactivity, and method comparison following the guidelines of the Clinical Laboratory Standards Institute (CLSI). The LoD is 0.50 ng/ml. A linear relationship is shown in the range of 0.5–200 ng/ml. A high dose effect is not seen up to approximately 500,000 ng/ml. The recovery range is from 94.7 to 108.9%. The %CV of run-to-run and within-lab variations are less than 2.04 and 4.41% across the CEA concentrations, respectively, whereas reproducibility is 4.45–6.24%. Method comparison shows that the assay correlates well with the reference device (R2 = 0.9884). The assay demonstrates acceptable precision, accuracy, LoB, LoD and LoQ, hook effect, linearity, interference, cross-reactivity, and high correlation with its reference device. Thus, the system is suitable for the quantification of CEA in clinical practices with a POCT manner.


  • Open Access

    Cyclic tangential flow filtration system for isolation of extracellular vesicles

    by Kimin Kim, Jungjae Park, Jik-Han Jung, Ruri Lee, Ji-Ho Park, Jong Min Yuk, Hyundoo Hwang, Ju Hun Yeon

    Size-based filtration techniques have been developed for high-throughput isolation of extracellular vesicles (EVs). Conventional direct filtration systems have limitations in that large particles generally not only block the pores of the membrane but also damage the particles because of the high fluid pressure. Here, we propose a cyclic tangential flow filtration (TFF) system that includes two membranes with pore sizes of 200 and 30 nm, connected to a peristaltic pump that feeds the stream flowing to the membrane for continuous circulation. The cyclic TFF system is better able to isolate the specific 30–200 nm size range in one step through dual cyclic filtration compared with direct filtration (DF) and single cyclic TFF (scTFF). We further introduced a buffer-exchange process to the dcTFF system after filtration to remove contaminants for more efficient purification. As a result of comparative evaluation of dcTFF and ExoQuick, EVs isolated by dcTFF had more abundant exosome markers and active EVs. The cyclic TFF system not only has great potential to separate EVs with high selectivity and separation efficiency in small volumes of samples but can also be used in clinical applications, including medical diagnostic procedures.


  • Open Access

    Dynamic Mitochondrial Migratory Features Associated with Calcium Responses during T Cell Antigen Recognition

    by Luye He, Andrew D. Raddatz, Fangyuan Zhou, Hyundoo Hwang, Melissa L. Kemp, Hang Lu

    A T cell clone is able to distinguish Ags in the form of peptide–MHC complexes with high specificity and sensitivity; however, how subtle differences in peptide–MHC structures translate to distinct T cell effector functions remains unknown. We hypothesized that mitochondrial positioning and associated calcium responses play an important role in T cell Ag recognition. We engineered a microfluidic system to precisely manipulate and synchronize a large number of cell–cell pairing events, which provided simultaneous real-time signaling imaging and organelle tracking with temporal precision. In addition, we developed image-derived metrics to quantify calcium response and mitochondria movement. Using myelin proteolipid altered peptide ligands and a hybridoma T cell line derived from a mouse model of experimental autoimmune encephalomyelitis, we observed that Ag potency modulates calcium response at the single-cell level. We further developed a partial least squares regression model, which highlighted mitochondrial positioning as a strong predictor of calcium response. The model revealed T cell mitochondria sharply alter direction within minutes following exposure to agonist peptide Ag, changing from accumulation at the immunological synapse to retrograde movement toward the distal end of the T cell body. By quantifying mitochondria movement as a highly dynamic process with rapidly changing phases, our result reconciles conflicting prior reports of mitochondria positioning during T cell Ag recognition. We envision applying this pipeline of methodology to study cell interactions between other immune cell types to reveal important signaling phenomenon that is inaccessible because of data-limited experimental design.


  • MESIA: Magnetic force-assisted electrochemical sandwich immunoassays for quantification of prostate-specific antigen in human serum

    by Hyundoo Hwang, Eunjong Choi, Seungmok Han, Yunsung Lee, Taehwa Choi, Mikyoung Kim, Haegong Shin, Jaesik Kim, Jaekyu Choi


  • Evaluation of MARK BTM for Quantitative Measurement of Three Tumor Markers: Prostate Specific Antigen, Alpha Fetoprotein, and Carcinoembryonic Antigen

    by Hyundoo Hwang, Jaesik Kim, Jaekyu Choi, Kil Kim, Ho-Seong Han

    Background: Tumor marker assays have played a crucial role for screening cancers and monitoring cancer patients, as they reflect the status and prognosis of patients. Alpha fetoprotein (AFP), prostate specific antigen (PSA), and carcinoembryonic antigen (CEA) are the most commonly used tumor marker proteins. The MARK B (TM) immunoassay system is a novel platform based on magnetic nanoparticles and electrochemical immunoassay. Methods: The analytical performance of MARK B (TM) immunoassay system for determination of AFP, PSA, and CEA are evaluated. Comparisons of methods are also conducted by comparing the assay results of MARK B (TM) immunoassay system to that of cobas e 801 system. Results: The MARK B (TM) immunoassay system provides within-run, between-run, and between-day precisions for the three tumor markers, ranging from 1.13 - 7.46%. Data measured by the MARK B (TM) immunoassay system show high correlation with that of the cobas e 801 system, with a linear slope ranging from 0.966 to 1.042 and a correlation coefficient of r > 0.996 for the three markers. Conclusions: These results show that the MARK B (TM) immunoassay system can be used for the quantitative measurements of AFP, PSA, and CEA in clinical practice.


  • Open Access

    Biomarkers in Infectious Diseases

    by Hyundoo Hwang, Boo-Young Hwang, Juan Bueno


  • Synthesis of colloidal silver nanoparticle clusters and their application in ascorbic acid detection by SERS

    by Jorge L. Cholula-Díaz, Diana Lomelí-Marroquín, Bidhan Pramanick, Alfonso Nieto-Argüello, Luis A. Cantú-Castillo, Hyundoo Hwang


  • Mobile diagnostics: next-generation technologies for in vitro diagnostics

    by Joonchul Shin, Sudesna Chakravarty, Wooseok Choi, Kyungyeon Lee, Dongsik Han, Hyundoo Hwang, Jaekyu Choi, Hyo-Il Jung

    The emergence of a wide range of applications of smartphones along with advances in ‘liquid biopsy’ has significantly propelled medical research particularly in the field of in vitro diagnostics (IVD). Herein, we have presented a detailed analysis of IVD, its associated critical concerns and probable solutions. It also demonstrates the transition in terms of analytes from minimally invasive (blood) to non-invasive (urine, saliva and sweat) and depicts how the different features of a smartphone can be integrated for specific diagnostic purposes. This review basically highlights recent advances in the applications of smartphone-based biosensors in IVD taking into account the following factors: accuracy and portability; quantitative and qualitative analysis; and centralization and decentralization tests. Furthermore, the critical concerns and future direction of diagnostics based on smartphones are also discussed.