Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hyun-Ung Oh has a total of 122 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation on Effectiveness of Modeling of Metallic Mesh Fabric for Deployable Antenna Based on Static and Dynamic Property Tests

    by Jung-Soo Park, Kwang Woo Kim, Bong-Geon Chae, Hyun-Ung Oh

    In this study, we identified the stiffness, natural frequency, and damping properties of a metallic mesh fabric applied to spaceborne antennas and proposed finite element models (FEMs) based on static and dynamic property tests. Tensile tests along the course and wale directions were performed to analyze the static characteristics of the metallic mesh fabric, and dynamic property tests were conducted to evaluate natural frequencies and damping properties under pre–tensions. By applying pre–tensions of 1, 3, and 5 N to each edge of the mesh fabric, the 1st natural frequencies were derived as approximately 35, 50, and 60 Hz. Furthermore, by applying direct dynamic loads to the fabric, high damping properties (ζ ≈ 1.0) were confirmed. FEMs of the mesh fabric were developed using a 1D beam–based detailed model and a 2D shell–based simplified model. The effectiveness of both models was validated by comparing numerical results with experimental data, showing discrepancies below 5% for static stiffness in the linear elastic region and within 5.4% for the 1st natural frequency. To evaluate dynamic behavior under an agile attitude maneuver, the simplified mesh model was applied to a 4 m deployable antenna model. Under the maneuver profile, dynamic responses rapidly attenuated due to high damping, with residual vibrations showing peak displacements below 0.02 mm decaying to the origin within 0.2 s. For the proposed 4 m deployable antenna with the SUS316L Atlas–Atlas mesh, the post–disturbance dynamic influence was confirmed to be negligible, indicating that post–maneuver residual vibrations do not cause surface accuracy distortions or degradation in the antenna’s electrical RF performance in orbit.

  • Open Access

    Experimental investigation of effective thermal conductivity of knitted metal mesh fabrics for spaceborne deployable mesh reflector antennas

    by Hyun-Mo Sung, Min-Young Son, Bong-Geon Chae, Hyun-Ung Oh

  • Open Access

    Evaluation of Response Characteristics of Spaceborne Electronic Equipment Considering Mounting Boundary Conditions

    by Kyeong-Jae Lee, Hyun-Ung Oh

    In this study, the response characteristics of spaceborne electronic equipment under actual mounting boundary conditions were evaluated, and an equivalent contact stiffness-based modeling technique was proposed to compensate for the limitations of conventional boundary-condition-based analysis. Finite element analyses were performed for three configurations: an initial design, a structure with increased contact area, and a structure with added stiffeners. Random vibration tests were then conducted with accelerometers directly attached to the PCBs and housings under actual mounting conditions, and the results were compared with conventional analysis results. The conventional analysis overpredicted the actual responses for all configurations, showing discrepancies in response magnitude, housing bottom-surface behavior, and natural frequency distribution. These discrepancies were attributed to insufficient representation of the bottom-surface contact effect formed under actual mounting conditions. Therefore, an empirical equation for the equivalent contact stiffness was established by incorporating fastening force, effective contact area ratio, bottom-surface thickness, and effective span length, and implemented using CBUSH-element-based contact modeling. The proposed method improved the correlation between test and analysis results for all three configurations, demonstrating its applicability for reliable response prediction and overdesign reduction at the early design stage.

  • Open Access

    Image-Based Focus Retention Verification of a Commercial Optical Microscope Module in Launch Environments

    by Ji-Won Chae, Yeon-Hyeok Park, Hyun-Ung Oh

    Recent growth in space biomedicine has increased the need for compact optical microscope modules for biological observation under microgravity. In this study, two nominally identical commercial off-the-shelf (COTS) microscope units were evaluated under launch vibration and shock environments. One unit was mounted with a laminated viscoelastic passive vibration isolator, while the other was mounted without isolation. Random vibration and shock tests were performed to evaluate structural characteristics and focus retention. During random vibration, the non-isolated configuration showed high acceleration responses and clear focus degradation. In contrast, the isolated configuration reduced the overall acceleration response by up to 3.96 times and maintained a focus retention ratio above the study-specific screening threshold of 0.8. LLSS results and visual inspection showed no clear change in global structural characteristics or visible damage. After shock testing, both configurations remained above the same threshold with no marked focus degradation. Under the applied test conditions, broadband random vibration caused greater focus degradation than short-duration shock loading. These results indicate that image-based focus retention assessment should complement structural assessment when verifying COTS optical microscope modules for space biomedical applications.

  • Soft x-ray shielding characteristics of natural wood films with varying densities evaluated using a Ga2O3 Schottky diode detector

    by Thanh Huong Vo, Woo-Min Cho, Sunjae Kim, Hyun-Ung Oh, Wan Sik Hwang

    This study evaluates the x-ray shielding effectiveness of natural wood films with different densities using a Ga2O3-based Schottky barrier diode detector. Photocurrent suppression, as an indicator of shielding performance, is systematically correlated with wood density through both database-modeled attenuation data and experimental results under continuous soft x-ray exposure. The results demonstrate that higher-density wood samples exhibit markedly enhanced shielding efficiency, approaching that of lightweight metallic and polymeric materials in the 1–20 keV soft x-ray range. Temperature-dependent measurements further reveal that the shielding performance of the wood films decreases with increasing temperature, likely due to thermal degradation of the material. Despite this, high-density wood films maintain shielding efficiencies exceeding 85% up to 423 K, highlighting their potential as lightweight, eco-friendly, and thermally resilient secondary shielding materials for aerospace and high-altitude applications.


  • Open Access

    Design of a Deployable Pantograph Rib Structure-Based Parabolic Antenna

    by Hyeongseok Kang, Kwang-Woo Kim, Seonggun Joe, Hyun-Ung Oh, Byungkyu Kim

    Space mesh antennas require large-diameter reflectors to achieve aperture surfaces with high gain. To date, many pioneering studies have pursued deployable mechanisms capable of achieving high deployment ratios, primarily focusing on ring and umbrella structures for spaceborne antennas. In this work, a conceptual design of a Deployable Pantograph Rib structure-based parabolic Antenna (De-PaRA) is presented by employing pantograph structures that ensure high stowage efficiency. This approach addresses the shortcomings of conventional space antenna mechanisms. In parallel, this study aims to overcome the structural safety issues that may arise from insufficient axial stiffness of the rib geometry after deployment. To achieve these objectives, superelastic shape memory alloy (SMA) wires were integrated along the antenna ribs to reinforce axial stiffness while maintaining constant inter-rib spacing. Modal analysis demonstrated that SMA wire integration increases the axial stiffness by approximately 2-fold, with eigenfrequency rising from 9.932 to 14.3 Hz. A prototype with a 1.6 m deployed diameter, achieving a volume deployment ratio of 58.8, was quantitatively evaluated through multi-body dynamics simulations and experiments. These results demonstrate reliable deployment operation and mechanical feasibility.


  • Open Access

    Validation of PCB Strain-Based Methodology for Structural Design of Spaceborne Electronic Equipment Under Vertical Mounting Conditions in Launch Environments

    by Jae-Cheol Hwang, Kwang-Woo Kim, Hyun-Ung Oh

    Spaceborne electronic equipment printed circuit boards (PCBs) installed under vertical mounting boundary conditions are exposed to a tougher environment than horizontal mounting due to the boundary conditions under the launch environment. Steinberg’s theory, which was previously applied to evaluate the structural safety of spaceborne electronic equipment, generates large errors and leads to inaccurate results. Although the vertical mounting of spaceborne electronic equipment is increasing due to its thermal/structural advantages, no high-reliability methodology or research has been developed to secure structural safety in the launch environment. In this study, the Oh-Park methodology, a highly reliable technique for evaluating the structural safety of solder joints in space-use electrical components based on the strain of the PCB, was verified for vertical spaceborne electronic equipment. Consequently, fatigue life tests were performed on specimens with structures similar to those of the actual spaceborne electronic equipment. The results were compared and analyzed with predictions made using Steinberg’s theory and Oh-Park methodology, respectively. The structural safety assessment using the Oh-Park methodology represented the test results more accurately, indicating that the critical strain-based methodology is effective for the design of vertical spaceborne electronic equipment exhibiting more complex behaviors due to their structural characteristics.


  • Open Access

    Characteristics of Force Transmissibility in PLOVIS-II Cooler Micro-Vibration Isolation System

    by Yeon-Hyeok Park, Mun-Shin Jo, Hoon-Young Kim, Hyun-Ung Oh

    This study investigates the basic characteristics of force transmissibility for a passive launch and on-orbit vibration isolation system (PLOVIS-II), which was developed to examine the microvibration attenuation of a spaceborne cryogenic cooler. The design, based on a coil spring-type passive vibration isolation system without an additional launch-lock device, demonstrated an effective vibration attenuation performance in both launch and on-orbit vibration isolation. In this study, a test setup and method were developed to measure the force transmissibility of an isolator along each axis using a voice-coil-type non-contact vibration excitation instrument. In addition, the test results included the position sensitivity of PLOVIS-II, considering the worst misalignment of the isolation system, and its performance was compared with that of PLOVIS-I proposed in a previous study.