Sergio Canabrava
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sergio Canabrava has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Alberto Diniz-Filho
Univ Fed Minas Gerais, Dept Ophthalmol & Otorhinolaryngol, Belo Horizonte, MG, Brazil
2 shared publicationsAna Carolina Canêdo Domingos Lima
Departamento de Catarata, Santa Casa de Belo Horizonte, Belo Horizonte, MG, Brazil
2 shared publications- Guilherme Ribeiro
Hospital Oftalmológico de Brasília, Brasília, DF, Brazil
2 shared publications Adi Einan-Lifshitz
From the Cataract Department, Santa Casa of Belo Horizonte, Minas Gerais, Brazil (Canabrava, Carvalho); Department of Ophthalmology, Shamir Medical Center (formerly Assaf-Harofeh), Tzrifin, Israel (Mahler, Einan-Lifshitz); Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel (Mahler, Einan-Lifshitz); Complexo Hospitalario Universitario A Coruña, A Coruña, Spain (de Rojas Silva, Gaona)
1 shared publication- Alberto Diniz-Filho
Department of Ophthalmology and Otorhinolaryngology, Federal University of Minas Gerais, Belo Horizonte, Brazil
1 shared publication Alejandro Lopez Gaona
From the Cataract Department, Santa Casa of Belo Horizonte, Minas Gerais, Brazil (Canabrava, Carvalho); Department of Ophthalmology, Shamir Medical Center (formerly Assaf-Harofeh), Tzrifin, Israel (Mahler, Einan-Lifshitz); Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel (Mahler, Einan-Lifshitz); Complexo Hospitalario Universitario A Coruña, A Coruña, Spain (de Rojas Silva, Gaona)
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 13, e00175
Comment on: Shamil technique 3.0: a novel approach for extraocular scleral fixation of intraocular lenses
- 1 January 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 13, e00175
Open AccessComment on: Shamil technique 3.0: a novel approach for extraocular scleral fixation of intraocular lenses
- Open Access
- 16 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 13, e00140
Modified Canabrava technique with a 4-closed loop intraocular lens injected into the anterior chamber
The goal of this study was to describe and assess the efficacy of a new modification for scleral fixation of a 4-eyelet foldable intraocular lens (IOL) using a previous IOL injector in the anterior chamber. An uncontrolled case series was used to investigate the efficacy of this new modification of the original Canabrava technique. Intraocular pressure and visual acuity data were obtained preoperatively and postoperatively. Surgeries were performed with the new modification of the Canabrava technique in 12 patients with implantation incisions as small as 2.2 mm (3.2 to 2.2 mm). The follow-up period ranged from 1 to 13 months. Corrected distance visual acuity improved significantly in all 12 patients, from 0.38 to 0.31 logMAR, whereas the cell count from specular microscopy decreased in average (preoperatively 2191 cells/mm2; postoperatively 1843 cells/mm2) and median (preoperatively 2225 cells/mm2; postoperatively 1902 cells/mm2). This current modification of the Canabrava technique greatly simplifies the procedure, making it easier and faster and with a shorter learning curve.
- 16 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 13, e00140
Open AccessModified Canabrava technique with a 4-closed loop intraocular lens injected into the anterior chamber
The goal of this study was to describe and assess the efficacy of a new modification for scleral fixation of a 4-eyelet foldable intraocular lens (IOL) using a previous IOL injector in the anterior chamber. An uncontrolled case series was used to investigate the efficacy of this new modification of the original Canabrava technique. Intraocular pressure and visual acuity data were obtained preoperatively and postoperatively. Surgeries were performed with the new modification of the Canabrava technique in 12 patients with implantation incisions as small as 2.2 mm (3.2 to 2.2 mm). The follow-up period ranged from 1 to 13 months. Corrected distance visual acuity improved significantly in all 12 patients, from 0.38 to 0.31 logMAR, whereas the cell count from specular microscopy decreased in average (preoperatively 2191 cells/mm2; postoperatively 1843 cells/mm2) and median (preoperatively 2225 cells/mm2; postoperatively 1902 cells/mm2). This current modification of the Canabrava technique greatly simplifies the procedure, making it easier and faster and with a shorter learning curve.
- 1 August 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (8) , 901-902
Reply: Double-flanged polypropylene technique: 5-year results
An abstract is unavailable. This article is available as a PDF only.
- 1 August 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (8) , 901-902
Reply: Double-flanged polypropylene technique: 5-year results
An abstract is unavailable. This article is available as a PDF only.
- 20 July 2023
- Published by Springer Nature
- p. 49-54
History and Evolution of Double Flanged Suture Fixation
- 20 July 2023
- Published by Springer Nature
- p. 49-54
History and Evolution of Double Flanged Suture Fixation
- 1 June 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (6) , 565-570
Double-flanged polypropylene technique: 5-year results
Purpose: To assess the long-term (5-year) results and complications of the double-flanged polypropylene technique in patients with capsular tension segment fixation, nonfoldable intraocular lens (IOL) scleral fixation, and foldable IOL scleral fixation. Setting: Santa Casa de Belo Horizonte and Centro Oftalmológico de Minas Gerais. Design: Prospective case series. Methods: Eyes that underwent treatment using the double-flanged polypropylene technique between September 2016 to September 2021 were included. LogMAR visual acuity was recorded, as well as complications such as long-term polypropylene resistance, conjunctival erosion, conjunctival inflammation, flange exposure, internalization, endophthalmitis, retinal detachment, and cystoid macular edema. Results: 71 eyes of 61 patients were evaluated. The mean follow-up period for these eyes was 28.2 ± 14.3 (min: 4; max: 60; median: 26) months. 173 flanges were performed. 13 cases with sub-Tenon flanges (7.5%) were observed. 5 exposed flanges (2.89%), presented after a mean of 1.8 weeks postoperatively, were observed. 1 patient with large flanges presented with conjunctival inflammation and hyperemia. 2 late internalized flanges (1.1%) and 2 recently internalized flanges (1.1%) were observed. 3 eyes (4.22%) had retinal detachment. Moreover, cystoid macular edema was detected in 3 eyes (4.22%). No cases of endophthalmitis were observed. Conclusions: The double-flanged technique was proven to be stable when the correct technical procedure was followed. However, complications can be observed, especially with short scleral tunnels and in eyes where the flanges were not buried inside the sclera.
- 1 June 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (6) , 565-570
Double-flanged polypropylene technique: 5-year results
Purpose: To assess the long-term (5-year) results and complications of the double-flanged polypropylene technique in patients with capsular tension segment fixation, nonfoldable intraocular lens (IOL) scleral fixation, and foldable IOL scleral fixation. Setting: Santa Casa de Belo Horizonte and Centro Oftalmológico de Minas Gerais. Design: Prospective case series. Methods: Eyes that underwent treatment using the double-flanged polypropylene technique between September 2016 to September 2021 were included. LogMAR visual acuity was recorded, as well as complications such as long-term polypropylene resistance, conjunctival erosion, conjunctival inflammation, flange exposure, internalization, endophthalmitis, retinal detachment, and cystoid macular edema. Results: 71 eyes of 61 patients were evaluated. The mean follow-up period for these eyes was 28.2 ± 14.3 (min: 4; max: 60; median: 26) months. 173 flanges were performed. 13 cases with sub-Tenon flanges (7.5%) were observed. 5 exposed flanges (2.89%), presented after a mean of 1.8 weeks postoperatively, were observed. 1 patient with large flanges presented with conjunctival inflammation and hyperemia. 2 late internalized flanges (1.1%) and 2 recently internalized flanges (1.1%) were observed. 3 eyes (4.22%) had retinal detachment. Moreover, cystoid macular edema was detected in 3 eyes (4.22%). No cases of endophthalmitis were observed. Conclusions: The double-flanged technique was proven to be stable when the correct technical procedure was followed. However, complications can be observed, especially with short scleral tunnels and in eyes where the flanges were not buried inside the sclera.
- 6 April 2022
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 33 (4) , NP23-NP26
Late internalized double-flanged polypropylene with canabrava technique in patient with marfan syndrome
Introduction: This paper reports the first occurrence of a late internalized flange due to capsular contraction syndrome after undergoing the double-flanged surgical technique.Case Description: A 32-year-old woman with Marfan syndrome underwent phacoemulsification using the double-flanged technique in both eyes. Two years postoperatively, a slit lamp examination revealed a capsular bag with anterior phimosis (capsular contraction syndrome) and the external flange internalized. The patient was submitted for a new surgery to re-fixate the capsular bag. The procedure was successfully accomplished. The intraocular lens was centered by the end of the procedure without areas of traction. The patient presented with best corrected visual acuity of 20/25 in both eyes postoperatively.Conclusions: This paper recounts a successful re-approach of a late internalized double-flange two years after the first procedure in a patient that developed capsular contraction syndrome.
- 6 April 2022
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 33 (4) , NP23-NP26
Late internalized double-flanged polypropylene with canabrava technique in patient with marfan syndrome
Introduction: This paper reports the first occurrence of a late internalized flange due to capsular contraction syndrome after undergoing the double-flanged surgical technique.Case Description: A 32-year-old woman with Marfan syndrome underwent phacoemulsification using the double-flanged technique in both eyes. Two years postoperatively, a slit lamp examination revealed a capsular bag with anterior phimosis (capsular contraction syndrome) and the external flange internalized. The patient was submitted for a new surgery to re-fixate the capsular bag. The procedure was successfully accomplished. The intraocular lens was centered by the end of the procedure without areas of traction. The patient presented with best corrected visual acuity of 20/25 in both eyes postoperatively.Conclusions: This paper recounts a successful re-approach of a late internalized double-flange two years after the first procedure in a patient that developed capsular contraction syndrome.
- 25 January 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (3) , 383-384
Comment on: Flange erosion/exposure and the risk for endophthalmitis
An abstract is unavailable. This article is available as a PDF only.
- 25 January 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (3) , 383-384
Comment on: Flange erosion/exposure and the risk for endophthalmitis
An abstract is unavailable. This article is available as a PDF only.
- Open Access
- 1 January 2022
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 86 (2) , 113-120
18-month results of double-flanged 5-0 polypropylene suture transscleral bag fixation in subluxated cataracts
To evaluate the stability and efficacy of the double-flanged 5-0 polypropylene suture to fixate subluxated cataracts at 18 months and the possible complications of this new technique. This technique uses a 5-0 polypropylene monofilament to create two flanges with a thermocautery, for fixation of a capsular tension segment to the sclera to fix the subluxated capsular bag. This technique was implemented in 17 eyes requiring intraocular lens implantation in a setting of zonular dialysis due to trauma, Marfan syndrome, microspherophakia, idiopathic disease, and post-phacoemulsification status. Follow-up of the patients occurred at 18 months. Best-corrected visual acuity improved significantly from 0.85 to 0.39 (logMAR), whereas the spherical and cylindrical refractive errors and intraocular pressure remained stable from preoperation. No suture photodegradation or pseudophacodonesis were detected. The double-flanged 5-0 polypropylene suture transscleral bag fixation technique has shown favorable long-term outcomes in terms of bag intraocular lens/complex fixation and stability. In eyes with zonular weakness or dialysis, this technique appears to be a safe and knotless option for cataract surgery.
- 1 January 2022
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 86 (2) , 113-120
Open Access18-month results of double-flanged 5-0 polypropylene suture transscleral bag fixation in subluxated cataracts
To evaluate the stability and efficacy of the double-flanged 5-0 polypropylene suture to fixate subluxated cataracts at 18 months and the possible complications of this new technique. This technique uses a 5-0 polypropylene monofilament to create two flanges with a thermocautery, for fixation of a capsular tension segment to the sclera to fix the subluxated capsular bag. This technique was implemented in 17 eyes requiring intraocular lens implantation in a setting of zonular dialysis due to trauma, Marfan syndrome, microspherophakia, idiopathic disease, and post-phacoemulsification status. Follow-up of the patients occurred at 18 months. Best-corrected visual acuity improved significantly from 0.85 to 0.39 (logMAR), whereas the spherical and cylindrical refractive errors and intraocular pressure remained stable from preoperation. No suture photodegradation or pseudophacodonesis were detected. The double-flanged 5-0 polypropylene suture transscleral bag fixation technique has shown favorable long-term outcomes in terms of bag intraocular lens/complex fixation and stability. In eyes with zonular weakness or dialysis, this technique appears to be a safe and knotless option for cataract surgery.
- 8 October 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 9 (4) , e00058
Exposed polypropylene flange in the Canabrava double-flanged polypropylene technique
Scleral fixation is a versatile surgical approach in the setting of lens bag instability. Recently, a double-flanged polypropylene technique to fixate the intraocular lens in the sclera has been described. A common concern in using any flanged scleral fixation technique is the risk of infection and endophthalmitis secondary to exposed fixation material, which can erode through the conjunctiva. In this report, a case of an exposed polypropylene flange presenting 1 month postoperatively in a 70-year-old female patient who underwent a 4-flanged fixation procedure is described. The successful surgical management of this case is described as well as other operative considerations to reduce the risk of exposed fixation material and subsequent postoperative infection. The correct placement of scleral fixation material as well as regular clinical review is vital in reducing the risk of postoperative endophthalmitis.
- 8 October 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery Online Case Reports
- Vol. 9 (4) , e00058
Exposed polypropylene flange in the Canabrava double-flanged polypropylene technique
Scleral fixation is a versatile surgical approach in the setting of lens bag instability. Recently, a double-flanged polypropylene technique to fixate the intraocular lens in the sclera has been described. A common concern in using any flanged scleral fixation technique is the risk of infection and endophthalmitis secondary to exposed fixation material, which can erode through the conjunctiva. In this report, a case of an exposed polypropylene flange presenting 1 month postoperatively in a 70-year-old female patient who underwent a 4-flanged fixation procedure is described. The successful surgical management of this case is described as well as other operative considerations to reduce the risk of exposed fixation material and subsequent postoperative infection. The correct placement of scleral fixation material as well as regular clinical review is vital in reducing the risk of postoperative endophthalmitis.
- 13 July 2020
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 47 (2) , 265-269
Scleral fixation of a 4-eyelet foldable intraocular lens in patients with aphakia using a 4-flanged technique
A 29-gauge model test fine needle is used to create a beveled intrascleral tunnel; with microforceps, a 6-0 polypropylene suture is placed in the bore of the needle, which is used as a guide to pass and externalize the monofilament through the sclera. This maneuver is repeated by passing the suture ends through the intraocular lens (IOL) eyelets. The folded IOL is inserted and centered, the sutures are cut, and the flanges are created by thermocautery and inserted into the scleral tunnel. This technique was performed on 7 patients and visual acuity was recorded. The 4-flanged technique for scleral fixation using a 4-eyelet IOL was an effective and a safe treatment in the setting of aphakia.
- 13 July 2020
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 47 (2) , 265-269
Scleral fixation of a 4-eyelet foldable intraocular lens in patients with aphakia using a 4-flanged technique
A 29-gauge model test fine needle is used to create a beveled intrascleral tunnel; with microforceps, a 6-0 polypropylene suture is placed in the bore of the needle, which is used as a guide to pass and externalize the monofilament through the sclera. This maneuver is repeated by passing the suture ends through the intraocular lens (IOL) eyelets. The folded IOL is inserted and centered, the sutures are cut, and the flanges are created by thermocautery and inserted into the scleral tunnel. This technique was performed on 7 patients and visual acuity was recorded. The 4-flanged technique for scleral fixation using a 4-eyelet IOL was an effective and a safe treatment in the setting of aphakia.