Qianbin Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qianbin Zhao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Jun Zhang
Queensland Quantum and Advanced Technologies Research Institute Griffith University Nathan Queensland Australia
5 shared publications - Dan Yuan
School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, QLD 4072, Australia
4 shared publications - Sheng Yan
Institute for Advanced Study, Shenzhen University, Shenzhen 518060, China
4 shared publications - Weihua Li
School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, New South Wales 2522, Australia
4 shared publications - Boran Zhang
School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
2 shared publications Boran Zhang
School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 1 January 2023
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 4
An On-Chip Viscoelasticity Sensor for Biological Fluids
There are so many non-Newtonian fluids in our daily life, such as milk, blood, cytoplasm, and mucus, most of which are viscoelastic heterogeneous liquid containing cells, inorganic ion, metabolites, and hormones. In microfluidic microparticle-manipulating applications, the target particles are practically distributed within the biological fluids like blood and urine. The viscoelasticity of biological fluid is constantly ignored for simplicity especially when the fluid is substantially diluted and contains rather complex components. However, even the fluid’s ultraweak viscoelasticity actually affects the microparticle migration and may bring a completely different behavior compared with the Newtonian fluids. As a result, a robust and easy operated on-chip viscoelasticity sensor is potential and desired in many research and industrial fields, including assay sample preparation, clinical diagnostics, and on-chip sensor. In this work, we employed stable non-Newtonian fluid–polyethylene oxide (PEO) solutions with various concentrations to investigate and calibrate effects of the weak fluidic viscoelasticity on microparticle behaviors in a double-layered microfluidic channel. An analogy-based database of fluidic patterns for viscoelasticity sensing and relaxation time measurement was established. Then, we tested different biological fluids including blood plasma and fetal bovine serum and proved that they exhibited similar viscoelasticity effects to the PEO solutions with the corresponding concentration, which reached a good agreement with available results by references. The detection limitation of relaxation time can reach 1 ms. It promised a robust and integrated on-chip microfluidic viscoelasticity sensor for different biological fluids without complicated calculations.
- 1 January 2023
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 4
Top Cited PapersOpen AccessAn On-Chip Viscoelasticity Sensor for Biological Fluids
There are so many non-Newtonian fluids in our daily life, such as milk, blood, cytoplasm, and mucus, most of which are viscoelastic heterogeneous liquid containing cells, inorganic ion, metabolites, and hormones. In microfluidic microparticle-manipulating applications, the target particles are practically distributed within the biological fluids like blood and urine. The viscoelasticity of biological fluid is constantly ignored for simplicity especially when the fluid is substantially diluted and contains rather complex components. However, even the fluid’s ultraweak viscoelasticity actually affects the microparticle migration and may bring a completely different behavior compared with the Newtonian fluids. As a result, a robust and easy operated on-chip viscoelasticity sensor is potential and desired in many research and industrial fields, including assay sample preparation, clinical diagnostics, and on-chip sensor. In this work, we employed stable non-Newtonian fluid–polyethylene oxide (PEO) solutions with various concentrations to investigate and calibrate effects of the weak fluidic viscoelasticity on microparticle behaviors in a double-layered microfluidic channel. An analogy-based database of fluidic patterns for viscoelasticity sensing and relaxation time measurement was established. Then, we tested different biological fluids including blood plasma and fetal bovine serum and proved that they exhibited similar viscoelasticity effects to the PEO solutions with the corresponding concentration, which reached a good agreement with available results by references. The detection limitation of relaxation time can reach 1 ms. It promised a robust and integrated on-chip microfluidic viscoelasticity sensor for different biological fluids without complicated calculations.
- 1 December 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (12) , 122002
Experimental exploration on stable expansion phenomenon of sheath flow in viscous microfluidics
Microfluidic technologies have been developed for decades, especially in bio-chemical research and applications. Among them, sheath flow is one of the most well-known techniques used for focusing microparticles into extremely narrow widths. With varying Reynolds numbers, sheath flow displays different behaviors, including diffusion, stable thread, and turbulence. In this study, a previously unknown phenomenon, namely, stable expansion, is originally reported in a 200 × 70 μm microchannel with a Reynolds number ranging from ∼10 to ∼110. This stable expansion of focusing width differs from all the reported phenomena in the literature and is experimentally explored in this study. First, the phenomenon is introduced, identified, and comprehensively described using different experimental samples and methods. Subsequently, an image processing algorithm of post-analysis is proposed and calibrated by the theoretical results of stable thread. Based on the calibrated standard protocol, the effects of flow rates and a hysteresis phenomenon due to variation in the flow rate are revealed and studied. In addition, the effects of fluid viscosity are investigated by introducing a mixture of deionized (DI) water and glycerin. It is found that, in this 200 × 70 μm2 (weight × height) microchannel made of PDMS, the stable expansion phenomenon will occur when the Reynolds number exceeds 10, and the expanded width will increase with total flow rate. Moreover, it is found that the expanded width in a flow rate reducing route is displayed to be wider than that in an increasing route. On the other hand, a high viscosity contrast (>40) between the middle sample and sheath flows can eliminate the focusing width expansion. The results indicate that this originally revealed phenomenon is experimentally repeatable and worth further studying to help researchers better understand the mechanism of microfluidics.
- 1 December 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (12) , 122002
Experimental exploration on stable expansion phenomenon of sheath flow in viscous microfluidics
Microfluidic technologies have been developed for decades, especially in bio-chemical research and applications. Among them, sheath flow is one of the most well-known techniques used for focusing microparticles into extremely narrow widths. With varying Reynolds numbers, sheath flow displays different behaviors, including diffusion, stable thread, and turbulence. In this study, a previously unknown phenomenon, namely, stable expansion, is originally reported in a 200 × 70 μm microchannel with a Reynolds number ranging from ∼10 to ∼110. This stable expansion of focusing width differs from all the reported phenomena in the literature and is experimentally explored in this study. First, the phenomenon is introduced, identified, and comprehensively described using different experimental samples and methods. Subsequently, an image processing algorithm of post-analysis is proposed and calibrated by the theoretical results of stable thread. Based on the calibrated standard protocol, the effects of flow rates and a hysteresis phenomenon due to variation in the flow rate are revealed and studied. In addition, the effects of fluid viscosity are investigated by introducing a mixture of deionized (DI) water and glycerin. It is found that, in this 200 × 70 μm2 (weight × height) microchannel made of PDMS, the stable expansion phenomenon will occur when the Reynolds number exceeds 10, and the expanded width will increase with total flow rate. Moreover, it is found that the expanded width in a flow rate reducing route is displayed to be wider than that in an increasing route. On the other hand, a high viscosity contrast (>40) between the middle sample and sheath flows can eliminate the focusing width expansion. The results indicate that this originally revealed phenomenon is experimentally repeatable and worth further studying to help researchers better understand the mechanism of microfluidics.
- 2 November 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (23) , 4556-4573
Investigation of particle manipulation mechanism and size sorting strategy in a double-layered microchannel
Traditionally, comprehensive laboratorial experiments on newly proposed microfluidic devices are necessary for theoretical validation, technological design, methodological calibration and optimization. Multiple parameters and characteristics, such as the flow rate, particle size, microchannel dimensions, etc., should be studied by controlled trials, which could inevitably result in extensive experiments and a heavy burden on researchers. In this work, a novel numerical model was introduced to simulate particle migration within a complicated double-layered microchannel. Using the hybrid meshing method, the proposed model achieved a significant improvement in meshing quality, and remarkably reduced the required calculation resources at the same time. The robust, efficient and resource-saving numerical model was calibrated and validated with experimental results. Based on this model, 1) the mechanism of microparticle manipulation within the microchannel was revealed; 2) the primary reason for the microparticle focusing failure was investigated; and 3) the optimal microparticle sorting strategy at different flow rates was analyzed. In experiments, the obtained optimal strategy could approach a good sorting performance with a high recovery rate and high concentration ratio in a high-throughput manner. The proposed numerical model shows great potential in mechanism investigation and functional prediction for microfluidic technologies using unconventional designs.
- 2 November 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 22 (23) , 4556-4573
Investigation of particle manipulation mechanism and size sorting strategy in a double-layered microchannel
Traditionally, comprehensive laboratorial experiments on newly proposed microfluidic devices are necessary for theoretical validation, technological design, methodological calibration and optimization. Multiple parameters and characteristics, such as the flow rate, particle size, microchannel dimensions, etc., should be studied by controlled trials, which could inevitably result in extensive experiments and a heavy burden on researchers. In this work, a novel numerical model was introduced to simulate particle migration within a complicated double-layered microchannel. Using the hybrid meshing method, the proposed model achieved a significant improvement in meshing quality, and remarkably reduced the required calculation resources at the same time. The robust, efficient and resource-saving numerical model was calibrated and validated with experimental results. Based on this model, 1) the mechanism of microparticle manipulation within the microchannel was revealed; 2) the primary reason for the microparticle focusing failure was investigated; and 3) the optimal microparticle sorting strategy at different flow rates was analyzed. In experiments, the obtained optimal strategy could approach a good sorting performance with a high recovery rate and high concentration ratio in a high-throughput manner. The proposed numerical model shows great potential in mechanism investigation and functional prediction for microfluidic technologies using unconventional designs.
- Open Access
- 28 April 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (5) , 461
A Review of Secondary Flow in Inertial Microfluidics
Inertial microfluidic technology, which can manipulate the target particle entirely relying on the microchannel characteristic geometry and intrinsic hydrodynamic effect, has attracted great attention due to its fascinating advantages of high throughput, simplicity, high resolution and low cost. As a passive microfluidic technology, inertial microfluidics can precisely focus, separate, mix or trap target particles in a continuous and high-flow-speed manner without any extra external force field. Therefore, it is promising and has great potential for a wide range of industrial, biomedical and clinical applications. In the regime of inertial microfluidics, particle migration due to inertial effects forms multiple equilibrium positions in straight channels. However, this is not promising for particle detection and separation. Secondary flow, which is a relatively minor flow perpendicular to the primary flow, may reduce the number of equilibrium positions as well as modify the location of particles focusing within channel cross sections by applying an additional hydrodynamic drag. For secondary flow, the pattern and magnitude can be controlled by the well-designed channel structure, such as curvature or disturbance obstacle. The magnitude and form of generated secondary flow are greatly dependent on the disturbing microstructure. Therefore, many inventive and delicate applications of secondary flow in inertial microfluidics have been reported. In this review, we comprehensively summarize the usage of the secondary flow in inertial microfluidics.
- 28 April 2020
- Published by MDPI AG in Micromachines
- Vol. 11 (5) , 461
Open AccessA Review of Secondary Flow in Inertial Microfluidics
Inertial microfluidic technology, which can manipulate the target particle entirely relying on the microchannel characteristic geometry and intrinsic hydrodynamic effect, has attracted great attention due to its fascinating advantages of high throughput, simplicity, high resolution and low cost. As a passive microfluidic technology, inertial microfluidics can precisely focus, separate, mix or trap target particles in a continuous and high-flow-speed manner without any extra external force field. Therefore, it is promising and has great potential for a wide range of industrial, biomedical and clinical applications. In the regime of inertial microfluidics, particle migration due to inertial effects forms multiple equilibrium positions in straight channels. However, this is not promising for particle detection and separation. Secondary flow, which is a relatively minor flow perpendicular to the primary flow, may reduce the number of equilibrium positions as well as modify the location of particles focusing within channel cross sections by applying an additional hydrodynamic drag. For secondary flow, the pattern and magnitude can be controlled by the well-designed channel structure, such as curvature or disturbance obstacle. The magnitude and form of generated secondary flow are greatly dependent on the disturbing microstructure. Therefore, many inventive and delicate applications of secondary flow in inertial microfluidics have been reported. In this review, we comprehensively summarize the usage of the secondary flow in inertial microfluidics.
- 11 July 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (17) , 2811-2821
Sheathless separation of microalgae from bacteria using a simple straight channel based on viscoelastic microfluidics
Microalgae cells have been recognized as a promising sustainable resource to meet worldwide growing demands for renewable energy, food, livestock feed, water, cosmetics, pharmaceuticals, and materials. In order to ensure high-efficiency and high-quality production of biomass, biofuel, or bio-based products, purification procedures prior to the storage and cultivation of the microalgae from contaminated bacteria are of great importance. The present work proposed and developed a simple, sheathless, and efficient method to separate microalgae Chlorella from bacteria Bacillus Subtilis in a straight channel using the viscoelasticity of the medium. Microalgae and bacteria migrate to different lateral positions closer to the channel centre and channel walls respectively. Fluorescent microparticles with 1 μm and 5 μm diameters were first used to mimic the behaviours of bacteria and microalgae to optimize the separating conditions. Subsequently, size-based separation in Newtonian fluid and in viscoelastic fluid in straight channels with different aspect ratios was compared and demonstrated. Under the optimal condition, the removal ratio for 1 μm microparticles and separation efficiency for 5 μm particles can reach up to 98.28% and 93.85% respectively. For bacteria and microalgae cells separation, the removal ratio for bacteria and separation efficiency for microalgae cells is 92.69% and 100% respectively. This work demonstrated the continuous and sheathless separation of microalgae from bacteria for the first time by viscoelastic microfluidics. This technique can also be applied as an efficient and user-friendly method to separate mammalian cells or other kinds of cells.
- 11 July 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (17) , 2811-2821
Sheathless separation of microalgae from bacteria using a simple straight channel based on viscoelastic microfluidics
Microalgae cells have been recognized as a promising sustainable resource to meet worldwide growing demands for renewable energy, food, livestock feed, water, cosmetics, pharmaceuticals, and materials. In order to ensure high-efficiency and high-quality production of biomass, biofuel, or bio-based products, purification procedures prior to the storage and cultivation of the microalgae from contaminated bacteria are of great importance. The present work proposed and developed a simple, sheathless, and efficient method to separate microalgae Chlorella from bacteria Bacillus Subtilis in a straight channel using the viscoelasticity of the medium. Microalgae and bacteria migrate to different lateral positions closer to the channel centre and channel walls respectively. Fluorescent microparticles with 1 μm and 5 μm diameters were first used to mimic the behaviours of bacteria and microalgae to optimize the separating conditions. Subsequently, size-based separation in Newtonian fluid and in viscoelastic fluid in straight channels with different aspect ratios was compared and demonstrated. Under the optimal condition, the removal ratio for 1 μm microparticles and separation efficiency for 5 μm particles can reach up to 98.28% and 93.85% respectively. For bacteria and microalgae cells separation, the removal ratio for bacteria and separation efficiency for microalgae cells is 92.69% and 100% respectively. This work demonstrated the continuous and sheathless separation of microalgae from bacteria for the first time by viscoelastic microfluidics. This technique can also be applied as an efficient and user-friendly method to separate mammalian cells or other kinds of cells.
- Open Access
- 25 October 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (11) , 315
The Continuous Concentration of Particles and Cancer Cell Line Using Cell Margination in a Groove-Based Channel
In the capillary venules, blood cells auto-separate with red blood cells aggregating near the centre of vessel and the nucleated cells marginating toward the wall of vessel. In this experiment, we used cell margination to help enrich the Jurkat cells via a groove-based channel which provides a vertical expansion-contraction structure, wherein the red blood cells invade the grooves and push the Jurkat cells to the bottom of the channel. The secondary flows induced by the anisotropic grooves bring the Jurkat cells to the right sidewall. Rigid, 13-µm diameter polystyrene particles were spiked into the whole blood to verify the operating principle under various working conditions, and then tests were carried out using Jurkat cells (~15 µm). The performance of this device was quantified by analysing the cell distribution in a transverse direction at the outlet, and then measuring the cell concentration from the corresponding outlets. The results indicate that Jurkat cells were enriched by 22.3-fold with a recovery rate of 83.4%, thus proving that this microfluidic platform provides a gentle and passive way to isolate intact and viable Jurkat cells.
- 25 October 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (11) , 315
Open AccessThe Continuous Concentration of Particles and Cancer Cell Line Using Cell Margination in a Groove-Based Channel
In the capillary venules, blood cells auto-separate with red blood cells aggregating near the centre of vessel and the nucleated cells marginating toward the wall of vessel. In this experiment, we used cell margination to help enrich the Jurkat cells via a groove-based channel which provides a vertical expansion-contraction structure, wherein the red blood cells invade the grooves and push the Jurkat cells to the bottom of the channel. The secondary flows induced by the anisotropic grooves bring the Jurkat cells to the right sidewall. Rigid, 13-µm diameter polystyrene particles were spiked into the whole blood to verify the operating principle under various working conditions, and then tests were carried out using Jurkat cells (~15 µm). The performance of this device was quantified by analysing the cell distribution in a transverse direction at the outlet, and then measuring the cell concentration from the corresponding outlets. The results indicate that Jurkat cells were enriched by 22.3-fold with a recovery rate of 83.4%, thus proving that this microfluidic platform provides a gentle and passive way to isolate intact and viable Jurkat cells.
- Open Access
- 1 November 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (11) , 195
Tunable Particle Focusing in a Straight Channel with Symmetric Semicircle Obstacle Arrays Using Electrophoresis-Modified Inertial Effects
In this work, a novel microfluidic platform for tunable particle focusing in a straight channel with symmetric semicircle obstacle arrays using electrophoresis (EP)-modified inertial effects was presented. By exerting an EP force on the charged microparticles, a relative velocity gap between microspheres and fluid in a straight channel with symmetric semicircle obstacle arrays was implemented. The relative velocity and fluid shear will induce shear-slip lift force (Saffman lift force) perpendicular to the mainstream direction. Therefore, the focusing pattern can be altered using the electrophoresis-induced Saffman force. The effects of electric field direction, flow rate, electric field magnitude, and particle size were also studied. This demonstrates the possibility of adjusting the particle inertial focusing pattern in a straight channel with with symmetric semicircle obstacle arrays using electrophoresis. Manipulation of the lateral migration of focusing streaks increases controllability in applications such as blood cell filtration and the separation of cells by size.
- 1 November 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (11) , 195
Open AccessTunable Particle Focusing in a Straight Channel with Symmetric Semicircle Obstacle Arrays Using Electrophoresis-Modified Inertial Effects
In this work, a novel microfluidic platform for tunable particle focusing in a straight channel with symmetric semicircle obstacle arrays using electrophoresis (EP)-modified inertial effects was presented. By exerting an EP force on the charged microparticles, a relative velocity gap between microspheres and fluid in a straight channel with symmetric semicircle obstacle arrays was implemented. The relative velocity and fluid shear will induce shear-slip lift force (Saffman lift force) perpendicular to the mainstream direction. Therefore, the focusing pattern can be altered using the electrophoresis-induced Saffman force. The effects of electric field direction, flow rate, electric field magnitude, and particle size were also studied. This demonstrates the possibility of adjusting the particle inertial focusing pattern in a straight channel with with symmetric semicircle obstacle arrays using electrophoresis. Manipulation of the lateral migration of focusing streaks increases controllability in applications such as blood cell filtration and the separation of cells by size.