Michael I. Newton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael I. Newton has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Robert Harold Morris
School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK
29 shared publications - Glen McHale
University of Edinburgh
20 shared publications - Andrew M. J. Edwards
SOFT Group, School of Science and Technology, Nottingham Trent University 3 , Clifton Lane, Nottingham NG11 8NS, United Kingdom
6 shared publications - Carl Vernon Brown
Nottingham Trent University
6 shared publications - Martin Bencsik
School of Science and Technology, Nottingham Trent University, Clifton Lane, Nottingham NG11 8NS, UK
6 shared publications - Nicasio R. Geraldi
School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, UK
5 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 163 (1) , 64
A Low-Cost Benchtop NMR System for Measurements of Self-Diffusion Coefficients
The exponential decay of signals during Nuclear Magnetic Resonance (NMR) experiments results in part from the movement of molecules within the magnetic field gradients present in all real-world systems. For most samples, this motion is driven by molecular self-diffusion. NMR can be used to quantify this important sample parameter, which can reveal the molecular structure of a sample and the interaction of mobile molecules within it. This has a wide range of applications in areas such as the study of porous media, polymer characterization, and quality control in food systems. Most commercial systems that are currently available for diffusion measurements are expensive. This work utilizes a low-cost custom NMR probe system, consisting of a set of permanent magnets, a steel yoke arrangement, and a solenoid transmit-receive coil with custom electronics and a set of magnetic field gradient coils alongside a broadband spectrometer. Using this new system, we show that it is possible to use compact, lower-cost NMR probes to obtain self-diffusion coefficient measurements for two samples: water and 1-pentanol, achieving 3.4 × 10−9 m2s−1 and 4 × 10−10 m2s−1 values for the diffusion coefficients at room temperature (21 °C), compared to literature values of 2.023 × 10−9 m2s−1 at 20 °C and 2.05 × 10−10 m2s−1 at 15 °C, respectively. We thereby demonstrate that such a system allows for self-diffusion coefficient measurements using a pulsed gradient spin echo (PGSE) sequence at a fraction of the cost of typical diffusion measurement instruments.
- 2 November 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 163 (1) , 64
Open AccessA Low-Cost Benchtop NMR System for Measurements of Self-Diffusion Coefficients
The exponential decay of signals during Nuclear Magnetic Resonance (NMR) experiments results in part from the movement of molecules within the magnetic field gradients present in all real-world systems. For most samples, this motion is driven by molecular self-diffusion. NMR can be used to quantify this important sample parameter, which can reveal the molecular structure of a sample and the interaction of mobile molecules within it. This has a wide range of applications in areas such as the study of porous media, polymer characterization, and quality control in food systems. Most commercial systems that are currently available for diffusion measurements are expensive. This work utilizes a low-cost custom NMR probe system, consisting of a set of permanent magnets, a steel yoke arrangement, and a solenoid transmit-receive coil with custom electronics and a set of magnetic field gradient coils alongside a broadband spectrometer. Using this new system, we show that it is possible to use compact, lower-cost NMR probes to obtain self-diffusion coefficient measurements for two samples: water and 1-pentanol, achieving 3.4 × 10−9 m2s−1 and 4 × 10−10 m2s−1 values for the diffusion coefficients at room temperature (21 °C), compared to literature values of 2.023 × 10−9 m2s−1 at 20 °C and 2.05 × 10−10 m2s−1 at 15 °C, respectively. We thereby demonstrate that such a system allows for self-diffusion coefficient measurements using a pulsed gradient spin echo (PGSE) sequence at a fraction of the cost of typical diffusion measurement instruments.
- Open Access
- 7 November 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 118 (1) , 18
Towards Low-Cost Magnetic Resonance Relaxometry
Magnetic Resonance Relaxometry is a powerful technique that reveals a sample’s molecular dynamics thanks to the dependence of the T1 relaxation time on field strength. With applications in protein research, food systems, material development, and environmental science, relaxometry measurements are typically undertaken using a technique known as fast field cycling, where T1 is measured at a range of detection fields. However, the sample experiences relaxation in a variable field without the challenges associated with retuning a probe to each of the necessary frequencies of interest. This technique is limited by a maximum relaxation time, since the measurement and relaxation fields are typically applied using a fluid-cooled electromagnet, which will ultimately overheat for very long experimental times. In this work, we propose an alternative approach to permit measurements of samples with inherently long T1 values. We utilise a broadband spectrometer alongside a solenoid transmit-receive coil and custom tuning and matching boards, whilst two sets of magnets are moved around the coil, to achieve a range of different fields. By collecting a reduced number of points and utilising this method, we show it is still possible to make useful measurements on samples at a range of frequencies, which has great potential in quality assurance applications. We find a similar trend for food samples of corn oil, while manganese chloride, a common contrast agent, has more than a 100% difference when compared to traditional fast field cycling measurements.
- 7 November 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 118 (1) , 18
Open AccessTowards Low-Cost Magnetic Resonance Relaxometry
Magnetic Resonance Relaxometry is a powerful technique that reveals a sample’s molecular dynamics thanks to the dependence of the T1 relaxation time on field strength. With applications in protein research, food systems, material development, and environmental science, relaxometry measurements are typically undertaken using a technique known as fast field cycling, where T1 is measured at a range of detection fields. However, the sample experiences relaxation in a variable field without the challenges associated with retuning a probe to each of the necessary frequencies of interest. This technique is limited by a maximum relaxation time, since the measurement and relaxation fields are typically applied using a fluid-cooled electromagnet, which will ultimately overheat for very long experimental times. In this work, we propose an alternative approach to permit measurements of samples with inherently long T1 values. We utilise a broadband spectrometer alongside a solenoid transmit-receive coil and custom tuning and matching boards, whilst two sets of magnets are moved around the coil, to achieve a range of different fields. By collecting a reduced number of points and utilising this method, we show it is still possible to make useful measurements on samples at a range of frequencies, which has great potential in quality assurance applications. We find a similar trend for food samples of corn oil, while manganese chloride, a common contrast agent, has more than a 100% difference when compared to traditional fast field cycling measurements.
- Open Access
- 19 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (4) , 1679
Winter Carbon Dioxide Measurement in Honeybee Hives
Sensor technologies have sufficiently advanced to provide low-cost devices that can quantify carbon dioxide levels in honeybee hives with high temporal resolution and in a small enough package for hive deployment. Recent publications have shown that summer carbon dioxide levels vary throughout the day and night over ranges that typically exceed 5000 ppm. Such dramatic changes in a measurable parameter associated with bee physiology are likely to convey information about the colony health. In this work, we present data from four UK-based hives collected through the winter of 2022/2023, with a focus on seeing if carbon dioxide can indicate when colonies are at risk of failure. These hives have been fitted with two Sensirion SCD41 photoacoustic non-dispersive infrared (NDIR) carbon dioxide sensors, one in the queen excluder, at the top of the brood box, and one in the crown board, at the top of the hive. Hive scales have been used to monitor the hive mass, and internal and external temperature sensors have been included. Embedded accelerometers in the central frame of the brood box have been used to measure vibrations. Data showed that the high daily variation in carbon dioxide continued throughout the coldest days of winter, and the vibrational data suggested that daily fanning may be responsible for restoring lower carbon dioxide levels. The process of fanning will draw in colder air to the hive at a time when the bees should be using their energy to maintain the colony temperature. Monitoring carbon dioxide may provide feedback, prompting human intervention when the colony is close to collapse, and a better understanding may contribute to discussions on future hive design.
- 19 February 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (4) , 1679
Open AccessWinter Carbon Dioxide Measurement in Honeybee Hives
Sensor technologies have sufficiently advanced to provide low-cost devices that can quantify carbon dioxide levels in honeybee hives with high temporal resolution and in a small enough package for hive deployment. Recent publications have shown that summer carbon dioxide levels vary throughout the day and night over ranges that typically exceed 5000 ppm. Such dramatic changes in a measurable parameter associated with bee physiology are likely to convey information about the colony health. In this work, we present data from four UK-based hives collected through the winter of 2022/2023, with a focus on seeing if carbon dioxide can indicate when colonies are at risk of failure. These hives have been fitted with two Sensirion SCD41 photoacoustic non-dispersive infrared (NDIR) carbon dioxide sensors, one in the queen excluder, at the top of the brood box, and one in the crown board, at the top of the hive. Hive scales have been used to monitor the hive mass, and internal and external temperature sensors have been included. Embedded accelerometers in the central frame of the brood box have been used to measure vibrations. Data showed that the high daily variation in carbon dioxide continued throughout the coldest days of winter, and the vibrational data suggested that daily fanning may be responsible for restoring lower carbon dioxide levels. The process of fanning will draw in colder air to the hive at a time when the bees should be using their energy to maintain the colony temperature. Monitoring carbon dioxide may provide feedback, prompting human intervention when the colony is close to collapse, and a better understanding may contribute to discussions on future hive design.
- Open Access
A Monitoring System for Carbon Dioxide in Honeybee Hives: An Indicator of Colony Health
Non-dispersive infra-red (NDIR) detectors have become the dominant method for measuring atmospheric CO2, which is thought to be an important gas for honeybee colony health. In this work we describe a microcontroller-based system used to collect data from Senserion SCD41 NDIR sensors placed in the crown boards and queen excluders of honeybee colonies. The same sensors also provide relative humidity and temperature data. Several months of data have been recorded from four different hives. The mass change measurements, from hive scales, when foragers leave the hive were compared with the data from the gas sensors. Our data suggest that it is possible to estimate the colony size from the change in measured CO2, however no such link with the humidity is observed. Data are presented showing the CO2 decreasing over many weeks as a colony dies.
Open AccessA Monitoring System for Carbon Dioxide in Honeybee Hives: An Indicator of Colony Health
Non-dispersive infra-red (NDIR) detectors have become the dominant method for measuring atmospheric CO2, which is thought to be an important gas for honeybee colony health. In this work we describe a microcontroller-based system used to collect data from Senserion SCD41 NDIR sensors placed in the crown boards and queen excluders of honeybee colonies. The same sensors also provide relative humidity and temperature data. Several months of data have been recorded from four different hives. The mass change measurements, from hive scales, when foragers leave the hive were compared with the data from the gas sensors. Our data suggest that it is possible to estimate the colony size from the change in measured CO2, however no such link with the humidity is observed. Data are presented showing the CO2 decreasing over many weeks as a colony dies.
- Open Access
- 1 December 2022
- Published by MDPI AG in Engineering Proceedings
- Vol. 31 (1) , 57
A Spatially Resolved Temperature Measurement System for a Honeybee Colony Brood Box
Honeybee colonies depend on suitable temperatures for successful development. We demonstrate the use of a spatially resolved temperature measurement system for a honeybee colony by producing ten custom frames which results into four hundred eighty sensors across the hive. A first prototype used four layers of wax to embed the sensors, however, the honeybees rejected these and removed the wax before building new, irregular honeycomb. A second system using a single sheet of wax onto which the sensors were laid was accepted by the colony, and normal honeycomb was built. We showcase some of the data collected from this system.
- 1 December 2022
- Published by MDPI AG in Engineering Proceedings
- Vol. 31 (1) , 57
Open AccessA Spatially Resolved Temperature Measurement System for a Honeybee Colony Brood Box
Honeybee colonies depend on suitable temperatures for successful development. We demonstrate the use of a spatially resolved temperature measurement system for a honeybee colony by producing ten custom frames which results into four hundred eighty sensors across the hive. A first prototype used four layers of wax to embed the sensors, however, the honeybees rejected these and removed the wax before building new, irregular honeycomb. A second system using a single sheet of wax onto which the sensors were laid was accepted by the colony, and normal honeycomb was built. We showcase some of the data collected from this system.
- Open Access
- 9 May 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (19) , 191601
Dielectrowetting on curved surfaces
Programmable fluidic systems on curved and flexible substrates are of increasing interest. One approach to achieving programmability is the controlled sequential wetting and dewetting on a surface using voltage actuation. In particular, liquid dielectrophoresis techniques have recently been shown to provide the ability to form a spread liquid film on a normally liquid repellent, but rigid, substrate via applying a spatially periodic electrical potential underneath an initial sessile droplet. In this work, we demonstrate the creation of thin, rectangular shaped, films of electrically insulating liquid on the side of a curved and flexible liquid repellant substrate using dielectrophoresis forces. We find that the experimental threshold voltage for film formation has a monotonic dependence on the value of the substrate curvature in the range −0.4 mm−1 < < 0.26 mm−1. By considering the balance of stresses acting on the films, including the Laplace pressure and the Maxwell stress, we develop an analytical theoretical expression that is in excellent quantitative agreement with our curvature dependent experimental threshold voltage measurements. The resulting physical insights and the demonstration of programmable wettability on curved and flexible substrates with both positive and negative curvature provide the foundations for applications in imaging, displays, and biochemical analysis.- 9 May 2022
- Published by AIP Publishing in Applied Physics Letters
- Vol. 120 (19) , 191601
Open AccessDielectrowetting on curved surfaces
Programmable fluidic systems on curved and flexible substrates are of increasing interest. One approach to achieving programmability is the controlled sequential wetting and dewetting on a surface using voltage actuation. In particular, liquid dielectrophoresis techniques have recently been shown to provide the ability to form a spread liquid film on a normally liquid repellent, but rigid, substrate via applying a spatially periodic electrical potential underneath an initial sessile droplet. In this work, we demonstrate the creation of thin, rectangular shaped, films of electrically insulating liquid on the side of a curved and flexible liquid repellant substrate using dielectrophoresis forces. We find that the experimental threshold voltage for film formation has a monotonic dependence on the value of the substrate curvature in the range −0.4 mm−1 < < 0.26 mm−1. By considering the balance of stresses acting on the films, including the Laplace pressure and the Maxwell stress, we develop an analytical theoretical expression that is in excellent quantitative agreement with our curvature dependent experimental threshold voltage measurements. The resulting physical insights and the demonstration of programmable wettability on curved and flexible substrates with both positive and negative curvature provide the foundations for applications in imaging, displays, and biochemical analysis. - Open Access
- 13 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (18) , 8471
Editorial on Special Issue “Applications of Low Field Magnetic Resonance”
This Special Issue presents the latest advances in the applications of low field magnetic resonance
- 13 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (18) , 8471
Open AccessEditorial on Special Issue “Applications of Low Field Magnetic Resonance”
This Special Issue presents the latest advances in the applications of low field magnetic resonance
- 8 June 2021
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 37 (24) , 7328-7340
Lattice Boltzmann Simulations of Multiphase Dielectric Fluids
The dynamic effect of an electric field on dielectric liquids is called liquid dielectrophoresis. It is widely used in several industrial and scientific applications, including inkjet printing, microfabrication, and optical devices. Numerical simulations of liquid-dielectrophoresis are necessary to understand the fundamental physics of the phenomenon, but also to explore situations that might be difficult or expensive to implement experimentally. However, such modeling is challenging, as one needs to solve the electrostatic and fluid dynamics equations simultaneously. Here, we formulate a new lattice–Boltzmann method capable of modeling the dynamics of immiscible dielectric fluids coupled with electric fields within a single framework, thus eliminating the need of using separate algorithms to solve the electrostatic and fluid dynamics equations. We validate the numerical method by comparing it with analytical solutions and previously reported experimental results. Beyond the benchmarking of the method, we study the spreading of a droplet using a dielectrowetting setup and quantify the mechanism driving the variation of the apparent contact angle of the droplet with the applied voltage. Our method provides a useful tool to study liquid-dielectrophoresis and can be used to model dielectric fluids in general, such as liquid–liquid and liquid–gas systems.
- 8 June 2021
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 37 (24) , 7328-7340
Lattice Boltzmann Simulations of Multiphase Dielectric Fluids
The dynamic effect of an electric field on dielectric liquids is called liquid dielectrophoresis. It is widely used in several industrial and scientific applications, including inkjet printing, microfabrication, and optical devices. Numerical simulations of liquid-dielectrophoresis are necessary to understand the fundamental physics of the phenomenon, but also to explore situations that might be difficult or expensive to implement experimentally. However, such modeling is challenging, as one needs to solve the electrostatic and fluid dynamics equations simultaneously. Here, we formulate a new lattice–Boltzmann method capable of modeling the dynamics of immiscible dielectric fluids coupled with electric fields within a single framework, thus eliminating the need of using separate algorithms to solve the electrostatic and fluid dynamics equations. We validate the numerical method by comparing it with analytical solutions and previously reported experimental results. Beyond the benchmarking of the method, we study the spreading of a droplet using a dielectrowetting setup and quantify the mechanism driving the variation of the apparent contact angle of the droplet with the applied voltage. Our method provides a useful tool to study liquid-dielectrophoresis and can be used to model dielectric fluids in general, such as liquid–liquid and liquid–gas systems.
- Open Access
- 24 August 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (8) , 081601
Planar selective Leidenfrost propulsion without physically structured substrates or walls
The Leidenfrost effect allows droplets to be transported on a virtually frictionless layer of vapor above a superheated substrate. The substrates are normally topographically structured using subtractive techniques to produce saw-tooth, herringbone, and other patterns and bulk heated, leading to significant challenges in energy consumption and controlled operation. Here, we propose a planar lithographic approach to levitate and propel droplets using temperature profiles, which can be spatially patterned and controlled in time. We show that micro-patterned electrodes can be heated and provide control of the pressure profile and the vapor flow. Using these almost featureless planar substrates, we achieve self-directed motion of droplets, with velocities of approximately 30 mms−1, without topographically structuring the substrate or introducing physical walls. Our approach has the potential to be integrated into applications, such as digital microfluidics, where frictionless and contactless droplet transport may be advantageous.
- 24 August 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (8) , 081601
Open AccessPlanar selective Leidenfrost propulsion without physically structured substrates or walls
The Leidenfrost effect allows droplets to be transported on a virtually frictionless layer of vapor above a superheated substrate. The substrates are normally topographically structured using subtractive techniques to produce saw-tooth, herringbone, and other patterns and bulk heated, leading to significant challenges in energy consumption and controlled operation. Here, we propose a planar lithographic approach to levitate and propel droplets using temperature profiles, which can be spatially patterned and controlled in time. We show that micro-patterned electrodes can be heated and provide control of the pressure profile and the vapor flow. Using these almost featureless planar substrates, we achieve self-directed motion of droplets, with velocities of approximately 30 mms−1, without topographically structuring the substrate or introducing physical walls. Our approach has the potential to be integrated into applications, such as digital microfluidics, where frictionless and contactless droplet transport may be advantageous.
- Open Access
Advanced Sandwich Composite Cores for Patient Support in Advanced Clinical Imaging and Oncology Treatment
Ongoing advances in both imaging and treatment for oncology purposes have seen a significant rise in the use of not only the individual imaging modalities, but also their combination in single systems such as Positron Emission Tomography combined with Computed Tomography (PET–CT) and PET–MRI (Magnetic Resonance Imaging) when planning for advanced oncology treatment, the most demanding of which is proton therapy. This has identified issues in the availability of suitable materials upon which to support the patient undergoing imaging and treatment owing to the differing requirements for each of the techniques. Sandwich composites are often selected to solve this issue but there is little information regarding optimum materials for their cores. In this paper, we presented a range of materials which are suitable for such purposes and evaluated the performance for use in terms of PET signal attenuation, proton beam stopping, MRI signal shading and X-Ray CT visibility. We found that Extruded Polystyrene offers the best compromise for patient support and positioning structures across all modalities tested, allowing for significant savings in treatment planning time and delivering more efficient treatment with lower margins.
Open AccessAdvanced Sandwich Composite Cores for Patient Support in Advanced Clinical Imaging and Oncology Treatment
Ongoing advances in both imaging and treatment for oncology purposes have seen a significant rise in the use of not only the individual imaging modalities, but also their combination in single systems such as Positron Emission Tomography combined with Computed Tomography (PET–CT) and PET–MRI (Magnetic Resonance Imaging) when planning for advanced oncology treatment, the most demanding of which is proton therapy. This has identified issues in the availability of suitable materials upon which to support the patient undergoing imaging and treatment owing to the differing requirements for each of the techniques. Sandwich composites are often selected to solve this issue but there is little information regarding optimum materials for their cores. In this paper, we presented a range of materials which are suitable for such purposes and evaluated the performance for use in terms of PET signal attenuation, proton beam stopping, MRI signal shading and X-Ray CT visibility. We found that Extruded Polystyrene offers the best compromise for patient support and positioning structures across all modalities tested, allowing for significant savings in treatment planning time and delivering more efficient treatment with lower margins.