Xinrui Lu
Xinrui Lu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Ali M. Memari
Department of Architectural Engineering and Department of Civil and Environmental Engineering, The Pennsylvania State University, University Park, PA 16802, USA
3 shared publications Ali Memari
3 shared publicationsAli M. Memari
Department of Architectural Engineering and Department of Civil and Environmental Engineering, Penn State University, University Park, PA, USA
2 shared publications- Corey Gracie-Griffin
Department of Architectural Engineering, Penn State University, University Park, PA 16802, USA
1 shared publication - Hojae Yi
Department of Agricultural and Biological Engineering, Pennsylvania State University, University Park, USA
1 shared publication - Mahsa Hashemi
Falcon Group, Rockville, MD 20855, USA
1 shared publication
Latest Publications
- Open Access
Energy Performance Evaluation and Indoor Environmental Quality Study of a Home Renovated Using Hempcrete
Hempcrete is being recognized as an alternative bio-based insulation material for use in residential construction. A mixture of hemp fiber and hurd, lime, and water, this product can substitute fiberglass batt insulation and rigid foam insulation and reduce the carbon emissions associated with residential construction. While there are some studies on the thermal resistance of hempcrete and walls made with hempcrete, actual data on indoor environmental quality (IEQ) and energy performance of homes built with hempcrete are scarce. The research reported here presents an indoor environmental quality study based on measurements of the air inside a renovated house in New Castle, Pennsylvania, USA, that used hempcrete for walls. This paper also reports on the energy performance of the case study house based on energy modeling using the BEopt software tool using a comparative approach to show energy saving potential compared to the case of conventional batt insulation use. The project was initiated by DON Enterprises, Inc. to renovate a blighted house in New Castle, in an effort to demonstrate the feasibility of incorporating hempcrete into sustainable home building. This paper reports experimentally measured IEQ results and develops energy models and analyses of home energy use and discusses the evaluation of the energy efficiency of hempcrete walls compared with conventional fiberglass batt insulation.
Open AccessEnergy Performance Evaluation and Indoor Environmental Quality Study of a Home Renovated Using Hempcrete
Hempcrete is being recognized as an alternative bio-based insulation material for use in residential construction. A mixture of hemp fiber and hurd, lime, and water, this product can substitute fiberglass batt insulation and rigid foam insulation and reduce the carbon emissions associated with residential construction. While there are some studies on the thermal resistance of hempcrete and walls made with hempcrete, actual data on indoor environmental quality (IEQ) and energy performance of homes built with hempcrete are scarce. The research reported here presents an indoor environmental quality study based on measurements of the air inside a renovated house in New Castle, Pennsylvania, USA, that used hempcrete for walls. This paper also reports on the energy performance of the case study house based on energy modeling using the BEopt software tool using a comparative approach to show energy saving potential compared to the case of conventional batt insulation use. The project was initiated by DON Enterprises, Inc. to renovate a blighted house in New Castle, in an effort to demonstrate the feasibility of incorporating hempcrete into sustainable home building. This paper reports experimentally measured IEQ results and develops energy models and analyses of home energy use and discusses the evaluation of the energy efficiency of hempcrete walls compared with conventional fiberglass batt insulation.
- Open Access
Comparison of the Experimental Measurement Methods for Building Envelope Thermal Transmittance
Building energy consumption and ways to reduce it have drawn increasing attention in recent decades. Thermal transmittance is not only a code-enforced parameter during the design and retrofit phase of building assemblies, but also strongly related to the accuracy of whole-building energy modeling. There are several existing methods to measure the building envelope thermal transmittance, and with the development of new techniques, more practical and precise measurement methods have been explored. The study discussed here focused on comparing methods to measure the building envelope thermal transmittance, both in laboratory and for in-situ measurement. Typical research studies related to the Hot Box Test Method, the Heat Flow Meter Method and the Infrared Thermography Method are described and compared. This paper provides a state-of-the-art review of the up-to-date measurement methods for building envelope thermal transmittance and provides alternatives for engineers, architects and researchers to practically measure the building envelope thermal transmittance.
Open AccessComparison of the Experimental Measurement Methods for Building Envelope Thermal Transmittance
Building energy consumption and ways to reduce it have drawn increasing attention in recent decades. Thermal transmittance is not only a code-enforced parameter during the design and retrofit phase of building assemblies, but also strongly related to the accuracy of whole-building energy modeling. There are several existing methods to measure the building envelope thermal transmittance, and with the development of new techniques, more practical and precise measurement methods have been explored. The study discussed here focused on comparing methods to measure the building envelope thermal transmittance, both in laboratory and for in-situ measurement. Typical research studies related to the Hot Box Test Method, the Heat Flow Meter Method and the Infrared Thermography Method are described and compared. This paper provides a state-of-the-art review of the up-to-date measurement methods for building envelope thermal transmittance and provides alternatives for engineers, architects and researchers to practically measure the building envelope thermal transmittance.
- Open Access
- 1 March 2020
- Published by College Publishing in Journal of Green Building
- Vol. 15 (2) , 29-43
EVALUATION OF SELECTED DYNAMIC MODELS IN COMPARISON WITH HOT BOX TEST RESULTS FOR MEASUREMENT OF BUILDING ENVELOPE THERMAL PROPERTIES
This research is mainly focused on the experimental measurement of R-value by several different models. Building energy consumption accounts for about 40% of the total energy use in the U.S, and therefore accurate energy simulation is desired. The R-value is one of the key parameters that can influence the energy simulation results and therefore is of great importance. The Average Model has long been the most widely accepted method to measure the thermal properties of building components. However, its steady-state assumption and dependence on temperature difference limit its use especially for in-situ measurement. In this study, several dynamic models, including the Pentaur Model and R-C Network Models, are studied with test data obtained from a series of hot box tests performed in the Building Enclosure Testing Laboratory. The results show that the 3R2C model has the best performance and a desirable stability of accuracy with respect to different levels of temperature difference, and therefore is recommended for practical measurement. The results also indicate that unlike the Average Model, the accuracy of dynamic models does not necessarily depend on the level of temperature difference.
- 1 March 2020
- Published by College Publishing in Journal of Green Building
- Vol. 15 (2) , 29-43
Open AccessEVALUATION OF SELECTED DYNAMIC MODELS IN COMPARISON WITH HOT BOX TEST RESULTS FOR MEASUREMENT OF BUILDING ENVELOPE THERMAL PROPERTIES
This research is mainly focused on the experimental measurement of R-value by several different models. Building energy consumption accounts for about 40% of the total energy use in the U.S, and therefore accurate energy simulation is desired. The R-value is one of the key parameters that can influence the energy simulation results and therefore is of great importance. The Average Model has long been the most widely accepted method to measure the thermal properties of building components. However, its steady-state assumption and dependence on temperature difference limit its use especially for in-situ measurement. In this study, several dynamic models, including the Pentaur Model and R-C Network Models, are studied with test data obtained from a series of hot box tests performed in the Building Enclosure Testing Laboratory. The results show that the 3R2C model has the best performance and a desirable stability of accuracy with respect to different levels of temperature difference, and therefore is recommended for practical measurement. The results also indicate that unlike the Average Model, the accuracy of dynamic models does not necessarily depend on the level of temperature difference.
- 1 November 2019
- Published by Elsevier in Journal of Building Engineering
- Vol. 26
Application of infrared thermography for in-situ determination of building envelope thermal properties
- 1 November 2019
- Published by Elsevier in Journal of Building Engineering
- Vol. 26
Application of infrared thermography for in-situ determination of building envelope thermal properties
- 1 August 2019
- Published by American Society of Civil Engineers (ASCE) in Practice Periodical on Structural Design and Construction
- Vol. 24 (3)
Comparative Energy Analysis and Life-Cycle Assessment of Innovative Residential Wall Systems in Cold Regions
This research mainly focused on energy simulation for residential buildings with different types of wall systems in Boston. Building-envelope systems have a significant influence on the whole building’s energy performance, and therefore quantitative comparisons are of interest. In this study, several types of high-performance wall systems, including advanced framing, structural insulated panels, insulated concrete forms, and the exterior insulation and finish system, as well as the most common wood-stud wall system, were studied with the use of building energy simulation. The results show that all of these types of wall systems effectively reduce the annual energy consumption, and the insulated concrete form is the best-performing method and has annual energy savings of 8.94% compared with the standard 50.8 × 101.6 mm (2 × 4 in.) wood-frame wall in Boston. The results also validate the anti-insulation effect at Philadelphia and Syracuse, which means that in some cases, increasing the insulation beyond a certain level may actually increase the use of energy for cooling. A life-cycle assessment was also performed, and the results show that the insulated concrete form wall system with a 152.4-mm (6-in.) concrete core has the best long-term energy performance, with overall life-cycle savings of 8%.
- 1 August 2019
- Published by American Society of Civil Engineers (ASCE) in Practice Periodical on Structural Design and Construction
- Vol. 24 (3)
Comparative Energy Analysis and Life-Cycle Assessment of Innovative Residential Wall Systems in Cold Regions
This research mainly focused on energy simulation for residential buildings with different types of wall systems in Boston. Building-envelope systems have a significant influence on the whole building’s energy performance, and therefore quantitative comparisons are of interest. In this study, several types of high-performance wall systems, including advanced framing, structural insulated panels, insulated concrete forms, and the exterior insulation and finish system, as well as the most common wood-stud wall system, were studied with the use of building energy simulation. The results show that all of these types of wall systems effectively reduce the annual energy consumption, and the insulated concrete form is the best-performing method and has annual energy savings of 8.94% compared with the standard 50.8 × 101.6 mm (2 × 4 in.) wood-frame wall in Boston. The results also validate the anti-insulation effect at Philadelphia and Syracuse, which means that in some cases, increasing the insulation beyond a certain level may actually increase the use of energy for cooling. A life-cycle assessment was also performed, and the results show that the insulated concrete form wall system with a 152.4-mm (6-in.) concrete core has the best long-term energy performance, with overall life-cycle savings of 8%.
- 6 May 2019
- Published by Taylor & Francis in Advances in Building Energy Research
- Vol. 15 (5) , 583-602
Determination of exterior convective heat transfer coefficient for low-rise residential buildings
This study is focused on the determination of exterior convective heat transfer coefficient for low-rise residential buildings. The convective heat transfer coefficient is an important parameter in building heat transfer analysis and building energy simulation. While there are many open literature studies based on either laboratory measurement or field testing, researchers have used different sources of wind data, testing conditions and building types, and therefore an applicable correlation especially for low-rise residential buildings is somewhat missing. In this study, a new calculation model is applied that comprehensively considers the influence of sky temperature, ground temperature as well as view factors. Several correlations are developed for both the convective heat transfer coefficient and the ground temperature, and an appropriate sky temperature model is selected. Based on the test data, an ASHRAE formula is also used to estimate the local wind speed using the free stream wind speed. The results of this study will provide new correlations of the convective heat transfer coefficient that can be used for low-rise residential buildings in the energy simulation process.
- 6 May 2019
- Published by Taylor & Francis in Advances in Building Energy Research
- Vol. 15 (5) , 583-602
Determination of exterior convective heat transfer coefficient for low-rise residential buildings
This study is focused on the determination of exterior convective heat transfer coefficient for low-rise residential buildings. The convective heat transfer coefficient is an important parameter in building heat transfer analysis and building energy simulation. While there are many open literature studies based on either laboratory measurement or field testing, researchers have used different sources of wind data, testing conditions and building types, and therefore an applicable correlation especially for low-rise residential buildings is somewhat missing. In this study, a new calculation model is applied that comprehensively considers the influence of sky temperature, ground temperature as well as view factors. Several correlations are developed for both the convective heat transfer coefficient and the ground temperature, and an appropriate sky temperature model is selected. Based on the test data, an ASHRAE formula is also used to estimate the local wind speed using the free stream wind speed. The results of this study will provide new correlations of the convective heat transfer coefficient that can be used for low-rise residential buildings in the energy simulation process.
- 1 March 2019
- Published by International Association for Sustainable Development and Management in International Journal of Architecture, Engineering and Construction
- Vol. 8 (1)
Performance Evaluation of Building Envelope Systems Incorporating Conventional and Innovative Insulation Materials
International Journal of Architecture, Engineering and Construction; Xueqing Zhang, Editor-in-Chief, Hong Kong University of Science and Technology; IJAEC; zhangxq@ust.hk.
- 1 March 2019
- Published by International Association for Sustainable Development and Management in International Journal of Architecture, Engineering and Construction
- Vol. 8 (1)
Performance Evaluation of Building Envelope Systems Incorporating Conventional and Innovative Insulation Materials
International Journal of Architecture, Engineering and Construction; Xueqing Zhang, Editor-in-Chief, Hong Kong University of Science and Technology; IJAEC; zhangxq@ust.hk.
- 1 November 2018
- Published by Elsevier in Energy and Buildings
- Vol. 178, 130-139
Comparative study of Hot Box Test Method using laboratory evaluation of thermal properties of a given building envelope system type
- 1 November 2018
- Published by Elsevier in Energy and Buildings
- Vol. 178, 130-139
Comparative study of Hot Box Test Method using laboratory evaluation of thermal properties of a given building envelope system type