Eray Uzgoren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Eray Uzgoren has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Wei Shyy
Department of Mechanical and Aerospace Engineering , The Hong Kong University of Science and Technology , Clear Water Bay , Kowloon , Hong Kong
8 shared publications - Jaeheon Sim
Saudi Aramco
4 shared publications - Musbaudeen O. Bamgbopa
Dubai Electricity and Water Authority (DEWA)
3 shared publications Rajkeshar Singh
GE Global Research
3 shared publications- Abdullah Mohiuddin
Department of Mechanical Engineering, Faculty of Engineering, University of Alberta, Edmonton, AB T6G 2R3, Canada
1 shared publication Eray Timur
Sustainable Environment and Energy Systems; Middle East Technical University Northern Cyprus Campus; Kalkanli, Guzelyurt Mersin 10 Turkey
1 shared publication
Latest Publications
- 26 September 2017
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 37 (3) , 1191-1200
Comparison of dynamic PTC thermal models using semi‐analytical and finite volume methods
Resource potential estimation of concentrating solar power (CSP) applications with parabolic through collectors (PTC) needs to address time-dependent heat transfer fluid (HTF) temperature at collector field's outlet. HTF temperature distribution depends on several time-dependent variables; i.e., HTF temperature at PTC inlet, direct beam radiation, HTF flow rate and its properties, and PTC parameters, i.e., overall heat transfer coefficient. The present paper develops a time-dependent one-dimensional thermal model for PTCs using the analytical solution of governing partial differential equation assuming time-invariant material properties, inlet temperature, and incident irradiation. Time-dependency component is then integrated into the analytical solution using a time advancing numerical scheme. The results are presented in a generalized non-dimensional form, which features familiar parameters, i.e., . It is shown that in contrast to the developed semi-analytical method, mesh-based methods suffer from an additional error source due to smoothening around . As a result, it is also showed that the developed method can use time steps 10 to 25 times larger than mesh-based methods that achieve similar accuracy levels. In addition, developed method's each time-step is found to be about 13 times faster. The combined speed-up is identified as 130–325 for PTC simulations that have high variations in inlet temperature. © 2017 American Institute of Chemical Engineers Environ Prog, 2017- 26 September 2017
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 37 (3) , 1191-1200
Comparison of dynamic PTC thermal models using semi‐analytical and finite volume methods
Resource potential estimation of concentrating solar power (CSP) applications with parabolic through collectors (PTC) needs to address time-dependent heat transfer fluid (HTF) temperature at collector field's outlet. HTF temperature distribution depends on several time-dependent variables; i.e., HTF temperature at PTC inlet, direct beam radiation, HTF flow rate and its properties, and PTC parameters, i.e., overall heat transfer coefficient. The present paper develops a time-dependent one-dimensional thermal model for PTCs using the analytical solution of governing partial differential equation assuming time-invariant material properties, inlet temperature, and incident irradiation. Time-dependency component is then integrated into the analytical solution using a time advancing numerical scheme. The results are presented in a generalized non-dimensional form, which features familiar parameters, i.e., . It is shown that in contrast to the developed semi-analytical method, mesh-based methods suffer from an additional error source due to smoothening around . As a result, it is also showed that the developed method can use time steps 10 to 25 times larger than mesh-based methods that achieve similar accuracy levels. In addition, developed method's each time-step is found to be about 13 times faster. The combined speed-up is identified as 130–325 for PTC simulations that have high variations in inlet temperature. © 2017 American Institute of Chemical Engineers Environ Prog, 2017- 20 June 2017
- Published by Springer Nature in Annals of Operations Research
- Vol. 262 (1) , 153-184
Photovoltaic power plant design considering multiple uncertainties and risk
- 20 June 2017
- Published by Springer Nature in Annals of Operations Research
- Vol. 262 (1) , 153-184
Photovoltaic power plant design considering multiple uncertainties and risk
- 1 April 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 98, 1036-1043
Computational analysis of a solar energy induced vortex generator
- 1 April 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 98, 1036-1043
Computational analysis of a solar energy induced vortex generator
- 25 February 2015
- Published by Wiley in International Journal of Energy Research
- Vol. 39 (8) , 1094-1108
A methodology to assess suitability of a site for small scale wet and dry CSP systems
- 25 February 2015
- Published by Wiley in International Journal of Energy Research
- Vol. 39 (8) , 1094-1108
A methodology to assess suitability of a site for small scale wet and dry CSP systems
- 1 August 2013
- Published by Elsevier in Energy Conversion and Management
- Vol. 72, 117-124
Quasi-dynamic model for an organic Rankine cycle
- 1 August 2013
- Published by Elsevier in Energy Conversion and Management
- Vol. 72, 117-124
Quasi-dynamic model for an organic Rankine cycle
- 1 July 2013
- Published by Elsevier in Applied Energy
- Vol. 107, 219-228
Numerical analysis of an organic Rankine cycle under steady and variable heat input
- 1 July 2013
- Published by Elsevier in Applied Energy
- Vol. 107, 219-228
Numerical analysis of an organic Rankine cycle under steady and variable heat input
- 23 July 2012
- Published by ASME International
- p. 195-202
Numerical Analysis of a Solar Organic Rankine Cycle (ORC) Unit With R245fa as Working Fluid
This paper presents a solar Organic Rankine Cycle (ORC) for electricity generation; where a regression based approach is used for the working fluid. Models of the unit’s sub-components (pump, evaporator, expander and condenser) are also presented. Heat supplied by the solar field can heat the water up to 80–95 °C at mass flow rates of 2–12 kg/s and deliver energy to the ORC’s heat exchanger unit. Simulation results of steady state operation using the developed model shows a maximum power output of around 40 kWe. Both refrigerant and hot water mass flow rates in the system are identified as critical parameters to optimize the power production and the cycle efficiency.
- 23 July 2012
- Published by ASME International
- p. 195-202
Numerical Analysis of a Solar Organic Rankine Cycle (ORC) Unit With R245fa as Working Fluid
This paper presents a solar Organic Rankine Cycle (ORC) for electricity generation; where a regression based approach is used for the working fluid. Models of the unit’s sub-components (pump, evaporator, expander and condenser) are also presented. Heat supplied by the solar field can heat the water up to 80–95 °C at mass flow rates of 2–12 kg/s and deliver energy to the ORC’s heat exchanger unit. Simulation results of steady state operation using the developed model shows a maximum power output of around 40 kWe. Both refrigerant and hot water mass flow rates in the system are identified as critical parameters to optimize the power production and the cycle efficiency.
- 6 October 2010
- Published by Wiley in International Journal for Numerical Methods in Fluids
- Vol. 67 (11) , 1373-1392
Adaptive Lagrangian-Eulerian computation of propagation and rupture of a liquid plug in a tube
- 6 October 2010
- Published by Wiley in International Journal for Numerical Methods in Fluids
- Vol. 67 (11) , 1373-1392
Adaptive Lagrangian-Eulerian computation of propagation and rupture of a liquid plug in a tube