Ian S. Armstrong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ian S. Armstrong has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Parthiban Arumugam
Nuclear Medicine, Manchester University NHS Foundation Trust, Oxford Road, Manchester, UK
9 shared publicationsChristine M. Tonge
Nuclear Medicine, Central Manchester University Hospitals, Oxford Road, Manchester, M13 9WL, UK
5 shared publicationsMatthew J. Memmott
Nuclear Medicine, Manchester University NHS Foundation Trust, Oxford Road, Manchester, UK
4 shared publicationsCharles Hayden
Siemens Medical Solutions USA, Inc, Molecular Imaging, Knoxville, TN, USA
3 shared publicationsJackie M. James
Nuclear Medicine Centre, Central Manchester University Hospitals NHS Foundation Trust
2 shared publicationsKimberley J. Saint
Nuclear Medicine, Manchester University NHS Foundation Trust, Oxford Road, Manchester, UK
2 shared publications
Latest Publications
- 23 August 2024
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 41, 102023
How to differentiate obstructive from non-obstructive CAD with PET: Developments in high-resolution regional quantification of MBF and MFR
- 23 August 2024
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 41, 102023
How to differentiate obstructive from non-obstructive CAD with PET: Developments in high-resolution regional quantification of MBF and MFR
- 1 May 2022
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 52 (3) , 286-301
Advances in PET/CT Technology: An Update
- 1 May 2022
- Published by Elsevier in Seminars in Nuclear Medicine
- Vol. 52 (3) , 286-301
Advances in PET/CT Technology: An Update
- 1 August 2021
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 28 (4) , 1334-1346
Assessment of motion correction in dynamic rubidium-82 cardiac PET with and without frame-by-frame adjustment of attenuation maps for calculation of myocardial blood flow
- 1 August 2021
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 28 (4) , 1334-1346
Assessment of motion correction in dynamic rubidium-82 cardiac PET with and without frame-by-frame adjustment of attenuation maps for calculation of myocardial blood flow
- 19 February 2021
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 29 (4) , 1596-1606
The prevalence of image degradation due to motion in rest-stress rubidium-82 imaging on a SiPM PET-CT system
- 19 February 2021
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 29 (4) , 1596-1606
The prevalence of image degradation due to motion in rest-stress rubidium-82 imaging on a SiPM PET-CT system
- Open Access
- 20 October 2020
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 28 (1) , 350-353
What is the optimal activity ratio for same-day myocardial perfusion SPECT?
- 20 October 2020
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 28 (1) , 350-353
Open AccessWhat is the optimal activity ratio for same-day myocardial perfusion SPECT?
- Open Access
- 21 May 2020
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 29 (1) , 56-68
A preliminary evaluation of a high temporal resolution data-driven motion correction algorithm for rubidium-82 on a SiPM PET-CT system
- 21 May 2020
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 29 (1) , 56-68
Open AccessA preliminary evaluation of a high temporal resolution data-driven motion correction algorithm for rubidium-82 on a SiPM PET-CT system
- 1 March 2019
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 40 (3) , 287-293
Spatial dependence of activity concentration recovery for a conjugate gradient (Siemens xSPECT) algorithm using manufacturer-defined reconstruction presets
Siemens absolute quantitative reconstruction, xSPECT, is available with manufacturer-defined reconstruction presets to assist with optimization. This phantom study evaluates the impact of these presets on the spatial dependence of activity concentration recovery (ACR). Single-photon emission computed tomography/computed tomography scans of a 5 : 1 and 10 : 1 (sphere : background) contrast NEMA phantom were performed on a Siemens Intevo 6. Three sphere position configurations, achieved by rotating the sphere mount through 0°, 120° and 240°, were used and three replicate images of each configuration were acquired. xSPECT reconstruction was performed using ‘Fast’, ‘Standard’ and ‘Best’ presets. Maximum voxel and A50 threshold ACR were measured in each sphere. The average ACR per sphere was calculated across replicates. Percentage variation of ACR, about this average, for each sphere within a given configuration across replicates and also alternative configurations was calculated. Within a given sphere configuration, percentage variation for maximum voxel ACR in like-for-like spheres across replicates was within 11% for all three presets across all sphere sizes, and within 3% for 10 : 1 and 9% for 5 : 1 contrast in the three largest spheres. Substantial variation of ACR was observed when comparing like-for-like spheres in different configurations. In the three largest spheres, variation in maximum ACR of up to 35 and 32% was measured for 10 : 1 and 5 : 1 contrast, respectively. Variation in activity concentration may be substantially greater than perceived from using a single phantom configuration. The spatial dependence observed using the manufacturer presets highlights the need for evaluation of user-defined reconstruction parameters.
- 1 March 2019
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 40 (3) , 287-293
Spatial dependence of activity concentration recovery for a conjugate gradient (Siemens xSPECT) algorithm using manufacturer-defined reconstruction presets
Siemens absolute quantitative reconstruction, xSPECT, is available with manufacturer-defined reconstruction presets to assist with optimization. This phantom study evaluates the impact of these presets on the spatial dependence of activity concentration recovery (ACR). Single-photon emission computed tomography/computed tomography scans of a 5 : 1 and 10 : 1 (sphere : background) contrast NEMA phantom were performed on a Siemens Intevo 6. Three sphere position configurations, achieved by rotating the sphere mount through 0°, 120° and 240°, were used and three replicate images of each configuration were acquired. xSPECT reconstruction was performed using ‘Fast’, ‘Standard’ and ‘Best’ presets. Maximum voxel and A50 threshold ACR were measured in each sphere. The average ACR per sphere was calculated across replicates. Percentage variation of ACR, about this average, for each sphere within a given configuration across replicates and also alternative configurations was calculated. Within a given sphere configuration, percentage variation for maximum voxel ACR in like-for-like spheres across replicates was within 11% for all three presets across all sphere sizes, and within 3% for 10 : 1 and 9% for 5 : 1 contrast in the three largest spheres. Substantial variation of ACR was observed when comparing like-for-like spheres in different configurations. In the three largest spheres, variation in maximum ACR of up to 35 and 32% was measured for 10 : 1 and 5 : 1 contrast, respectively. Variation in activity concentration may be substantially greater than perceived from using a single phantom configuration. The spatial dependence observed using the manufacturer presets highlights the need for evaluation of user-defined reconstruction parameters.
- 15 June 2018
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 25 (5) , 1546-1549
Understanding the impact of advanced PET reconstruction in cardiac PET: The devil is in the details
- 15 June 2018
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 25 (5) , 1546-1549
Understanding the impact of advanced PET reconstruction in cardiac PET: The devil is in the details
- Top Cited PapersOpen Access
- 25 May 2018
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 25 (5) , 1784-1846
Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation
- 25 May 2018
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 25 (5) , 1784-1846
Top Cited PapersOpen AccessSingle Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation