DCDavid W. Coutts

David W. Coutts

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David W. Coutts has a total of 313 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • MARVEL: approaching instrument assembly and commissioning

    by Jacob Pember, Ioannis Argyriou, Gerardo Avila, Vincent Benz, Alexis Brandeker, Lars A. Buchhave, Heather Cegla, David Coutts, Wim De Meester, Joris De Ridder, et al.

    The MARVEL dedicated radial velocity facility will soon be commissioned at the Mercator Observatory at La Palma, Spain. MARVEL comprises four 0.8m telescopes, each feeding starlight via optical fibres into a single high-resolution spectrograph tuned for precision radial velocity measurements. The four telescopes and their domes have been successfully installed at the observatory site, and are regularly being used for initial photometric observations. In this proceeding we provide a general status update of the facility, covering the procurement, assembly, and laboratory testing of spectrometer optics, mechanics, and detector; developments in the calibration system; the PLC-based control software; the dedicated solar telescope; and a photometry programme that is already underway, making use of the MARVEL telescopes before the installation of the spectrograph.


  • On-sky demonstration of precision photometry with Bayer color filter arrays

    by Wilfred Gee, Olivier Guyon, Nemanja Jovanovic, Christian Schwab, David Coutts, Josh Walawender, Aru Mukherjea

    Consumer-level digital single-lens reflex (DSLR) cameras are typically not used in professional astronomy because of the systematic errors present in the data as a result of the strong intra- and interpixel variations associated with each of the three different colors (RGB) of the Bayer color filter array. Nevertheless, because the cost of DSLRs compared with traditional astronomical CCDs is so much lower, they represent a potentially underexplored area of scientific quality astronomical imaging, especially in the area of wide-field transient surveys. We demonstrate an algorithm that can achieve ≈ 1 % level photometry in each of the RGB color channels from a stellar source and discuss the application of this algorithm to a ground-based transiting exoplanet survey. The algorithm primarily takes advantage of the large number of stellar sources available for statistical averaging within a single image, using a “lucky point-spread function” approach to identify sources in the image that exhibit systematic errors consistent with a chosen target from the same image. The selection of the appropriate“lucky” reference stars is accomplished through a comparison of the stellar image morphology as it appears on the Bayer array and the reference stars. These references are linearly combined to form a synthetic comparison star that can be used for differential photometry with the target. One key to the algorithm is that all data are retained at the individual pixel-level until the final differential comparison, which helps to alleviate systematic effects that might otherwise cancel each other out during the flux-summing process. We demonstrate the algorithm on HD 339461, a mV = 8.93 G0-type star on which we achieve single-percent level photometry that approaches the fundamental noise floor possible from a single camera.


  • Fiber modal noise mitigation by a rotating double scrambler

    by Gert Raskin, Dmytro Rogozin, Tom Mladenov, Christian Schwab, David W. Coutts

    Fiber modal noise is a performance limiting factor in high-precision radial velocity measurements with multi-mode fiber fed high-resolution spectrographs. Traditionally, modal noise is mitigated by agitating the fiber, this way redistributing the light that propagates in the fiber over many different modes. However, in case of fibers with only a limited number of modes, e.g. at near-infrared wavelengths or in adaptive-optics assisted systems, this method becomes very inefficient. The strong agitation that would be needed stresses the fiber and can lead to focal ratio degradation. As an alternative approach, we propose to use a classic optical double scrambler and to rotate the scrambler’s first fiber end during each exposure. Because of the rotating illumination pattern of the scrambler’s second fiber, the modes that are excited vary continuously. This leads to very efficient averaging of the modal pattern at the fiber exit and to a strong reduction of modal noise. In this contribution, we present a prototype design and first laboratory results of the rotating double scrambler.


  • Rubidium transitions as wavelength reference for astronomical Doppler spectrographs

    by Dmytro Rogozin, Tobias Feger, Christian Schwab, Yulia V. Gurevich, Gert Raskin, David W. Coutts, Julian Stuermer, Andreas Seifahrt, Thorsten Fuehrer, Thomas Legero, et al.

    Precise wavelength calibration is a critical issue for high-resolution spectroscopic observations. The ideal calibration source should be able to provide a very stable and dense grid of evenly distributed spectral lines of constant intensity. A new method which satisfies all mentioned conditions has been developed by our group. The approach is to actively measure the exact position of a single spectral line of a Fabry-Perot etalon with very high precision with a wavelength-tuneable laser and compare it to an extremely stable wavelength standard. The ideal choice of standard is the D2 absorption line of Rubidium, which has been used as an optical frequency standard for decades. With this technique, the problem of stable wavelength calibration of spectrographs becomes a problem of how reliably we can measure and anchor one etalon line to the Rb transition. In this work we present our self-built module for Rb saturated absorption spectroscopy and discuss its stability.

  • Beam shaping of a broad-area laser diode using 3D integrated optics

    by Simon Gross, David W. Coutts, Mark Dubinskiy, Michael J. Withford

    Typical high power broad-area semiconductor lasers exhibit a highly astigmatic beam profile. However, many applications require a homogenous and circular symmetric beam. Thus coupling into circular multimode optical fibers is often employed. The strip-like astigmatic output of the diode laser underfills the circular multimode fiber, thus a decrease in beam quality occurs after fiber coupling due to mode mixing inside the optical fiber. This Letter presents a 3D integrated optics approach to shape the output of a broad-area laser diode. Ultrafast laser inscription is utilized to create a pair of photonic lanterns connected back to back inside a glass chip that captures and shapes the output of a commercial 976 nm wavelength broad-area laser diode with 95 μm emitter width. Compared to coupling to a 105 μm diameter, 0.15 numerical aperture step-index multimode fiber, the photonic chip-based approach results in a 13× higher beam quality and 7× greater brightness.


  • A diagnostic tool for microbends in fibre termination as a source of FRD

    by David W. Coutts

    Microbends in multimode optical fibers are shown to lead to focal ratio degradation which compromises fiber fed spectrograph design and performance. By propagating specific vortex mode patterns through multimode fibers containing a single controlled microbend the mechanisms for FRD can be understood. For example, we see both experimentally and through ray tracing analysis that a microbend can produce spiral patterns in the far-field. These patterns are potentially useful tools for diagnosing termination problems in fiber assemblies. For example, by analyzing the spiral patterns produced by a single microbend it is possible to determine the location of a microbend hidden in the fiber termination.


  • Developing an ultra-stable single mode fiber spectrograph for adaptive optics assisted observation in the infrared

    by Blaise C. Kuo Tiong, Christian Schwab, Tobias Feger, David W. Coutts, Surangkhana Rukdee, Leonardo Vanzi

    Ever more precise radial velocity instruments are needed to observe potential earth-like exoplanet targets that are beyond the range of current generation high resolution echelle spectrographs. Meanwhile, extreme adaptive optics systems at 8 meter class facilities have made ground based observations possible at the diffraction limit. In the field of Doppler spectroscopy, one way to take advantage of these AO capabilities is by the development of ultra-stable single mode fiber fed spectrographs.1 Coupling the light efficiently into SMFs with an extreme adaptive optics system offers significant advantage in removing modal noise, reducing instrument size, enabling superior environmental control and curbing cost. We report the design and challenges in building an ultra-stable spectrograph for the near infrared range. The design wavelength range is 650 to 1500 nm.

  • The RHEA single-mode spectrograph

    by Tobias Feger, Christian Schwab, Blaise C. Kuo Tiong, Michael J. Ireland, David W. Coutts, Adam Rains

    RHEA is a compact high-resolution single-mode spectrograph that can easily be produced in larger quantities as budgets allow. The instrument will be housed in a temperature-stabilized vacuum chamber which is surrounded by several layers of thermal shielding. The optical design employs cost-effective commercially available compo- nents, a cooled CMOS detector, and a double-fiber input which permits simultaneous wavelength calibration.


  • Rubidium traced etalon wavelength calibrators: towards deployment at observatories

    by Christian Schwab, Tobias Feger, Julian Stürmer, Andreas Seifahrt, Yulia V. Gurevich, Dmytro Rogozin, David W. Coutts, Gert Raskin, Jacob L. Bean, Thorsten Fuehrer, et al.

    Precise wavelength calibration is a persistent problem for highest precision Doppler spectroscopy. The ideal calibrator provides an extremely stable spectrum of equidistant, narrow lines over a wide bandwidth, is reliable over timescales of years, and is simple to operate. Unlike traditional hollow cathode lamps, etalons provide an engineered spectrum with adjustable line distance and width and can cover a very broad spectral bandwidth. We have shown that laser locked etalons provide the necessary stability with an ideal spectral format for calibrating precision Echelle spectrographs, in a cost-effective and robust package. Anchoring the etalon spectrum to a very precisely known hyperfine transition of rubidium delivers cm/s-level stability over timescales of years. We have engineered a fieldable system which is currently being constructed as calibrator for the MAROON-X, HERMES, KPF, FIES and iLocater spectrographs.


  • A high resolution echelle spectrograph for exoplanet searches with small aperture telescopes

    by Logan DuBois, Nathan Lentini, Christian Schwab, Blaise C. Kuo Tiong, Tobias Feger, David W. Coutts, Cassandra Fallscheer

    High precision Doppler observations of bright stars can be made efficiently with small aperture telescopes. We are constructing a high resolution echelle spectrograph for the new 0.6 m telescope at Central Washington University. The spectrograph is fed by a multimode fiber and operates in the visible wavelength range of 380-670 nm. The spectrograph uses a white pupil design with 100 mm beam diameter and a monolithic R4 echelle grating.