Paul J. Govaerts
Research Subjects
Paul J. Govaerts has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
- Geert De Ceulaer
The Eargroup, Herentalsebaan 75, B-2100 Antwerp-Deurne, Belgium
9 shared publications - Bart Vaerenberg
The Eargroup, Herentalsebaan 75, B-2100 Antwerp-Deurne, Belgium
4 shared publications - David Pascoal
The Eargroup, Herentalsebaan 75, B-2100 Antwerp-Deurne, Belgium
4 shared publications Geert De Ceulaer
The Eargroup, Antwerp-Deurne, Belgium
4 shared publicationsKaren Schauwers
The EargroupAntwerp-Deurne, Belgium
4 shared publicationsBart Vaerenberg
3 shared publications
Latest Publications
- Open Access
- 30 October 2023
- Published by AVES YAYINCILIK A.Ş. in B-ENT
- Vol. 20 (1) , 53-57
Restoring Hearing After Resection of Vestibular Schwannoma by Cochlear Nerve Preservation and Cochlear Implantation: Long-Term Follow-Up of Two Cases
Hearing outcomes of two cases of growing sporadic vestibular schwannoma, resected via a translabyrinthine approach with simultaneous cochlear implantation are reported. After gross total resection and anatomical preservation of the facial and cochlear nerve, the integrity of the cochlear nerve—on an electrophysiological level—was evaluated using the intracochlear test electrode of the Auditory Nerve Test System. After confirming electrically-evoked auditory brainstem recordings, cochlear implantation and hearing rehabilitation were performed as per the single-sided deafness protocol. This report describes the audiological outcome with respect to speech understanding in quiet and noise, local ization of sounds as well as phoneme discrimination up to one year after surgery. Cite this article as: Jacxsens L, Lammers MJW, Jacquemin L, et al. Restoring hearing after resection of vestibular schwannoma by cochlear nerve preservation and cochlear implantation: long-term follow-up of two cases. B-ENT. 2024;20(1):53-57
- 30 October 2023
- Published by AVES YAYINCILIK A.Ş. in B-ENT
- Vol. 20 (1) , 53-57
Open AccessRestoring Hearing After Resection of Vestibular Schwannoma by Cochlear Nerve Preservation and Cochlear Implantation: Long-Term Follow-Up of Two Cases
Hearing outcomes of two cases of growing sporadic vestibular schwannoma, resected via a translabyrinthine approach with simultaneous cochlear implantation are reported. After gross total resection and anatomical preservation of the facial and cochlear nerve, the integrity of the cochlear nerve—on an electrophysiological level—was evaluated using the intracochlear test electrode of the Auditory Nerve Test System. After confirming electrically-evoked auditory brainstem recordings, cochlear implantation and hearing rehabilitation were performed as per the single-sided deafness protocol. This report describes the audiological outcome with respect to speech understanding in quiet and noise, local ization of sounds as well as phoneme discrimination up to one year after surgery. Cite this article as: Jacxsens L, Lammers MJW, Jacquemin L, et al. Restoring hearing after resection of vestibular schwannoma by cochlear nerve preservation and cochlear implantation: long-term follow-up of two cases. B-ENT. 2024;20(1):53-57
- 6 October 2021
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 43 (2) , 669-675
Speech Audiometrical Results Before and After Reimplantation of Cochlear Implants
Objectives: This study aimed to compare the audiological outcomes of cochlear reimplantation with those of the first cochlear implant (CI). Design: A retrospective analysis was performed on the data of all CI recipients who received the first CI at the age of 8 years or above and who were subsequently reimplanted on the same side. All participants who received their first implant after January 1, 2000, and who were reimplanted before January 1, 2021, were included. CI recipients who were unable to perform an open-set of Flemish monosyllable speech audiometry were excluded. The participants’ clinical files were reviewed in terms of the cause of hearing loss, age at the first and second implantation, device types, the time between the first and second surgery, speech reception scores before and after reimplantation, and the reason for reimplantation. Results: Reimplantation was due to device failure in 19 out of 22 patients, performance decrement in two patients, and medical reasons in one patient. The interval between the first and second CI ranged from 8 to 218 mo. Within-subject analysis showed the speech reception performance with the second CI to be significantly better than that with the first CI at all follow-up time points, with average within-patient gains of 17%, 16%, 12%, and 15% at 3 mo, 9 mo, 3 years, and the highest scores achieved, respectively. After reimplantation, the performance was better than the last results before reimplantation, and this was significant from 9 mo after reimplantation onwards. Three patients (14%) had a performance degradation with the second CI, which was probably owing to (1) difficulties in reimplantation surgery leading to a reduced number of active channels, (2) insufficient experience with the second CI as the reimplantation has been performed recently, and (3) advanced fenestral and retrofenestral otosclerosis. Conclusions: The present study shows that speech reception performance after reimplantation yields faster and better results than the first implant. It takes a couple of months to get better results than those before the reimplantation. Only in a minority of participants, a small deterioration may be observed. It seems that soft failures in the absence of measurable technical abnormalities call for caution with regard to reimplantation.
- 6 October 2021
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 43 (2) , 669-675
Speech Audiometrical Results Before and After Reimplantation of Cochlear Implants
Objectives: This study aimed to compare the audiological outcomes of cochlear reimplantation with those of the first cochlear implant (CI). Design: A retrospective analysis was performed on the data of all CI recipients who received the first CI at the age of 8 years or above and who were subsequently reimplanted on the same side. All participants who received their first implant after January 1, 2000, and who were reimplanted before January 1, 2021, were included. CI recipients who were unable to perform an open-set of Flemish monosyllable speech audiometry were excluded. The participants’ clinical files were reviewed in terms of the cause of hearing loss, age at the first and second implantation, device types, the time between the first and second surgery, speech reception scores before and after reimplantation, and the reason for reimplantation. Results: Reimplantation was due to device failure in 19 out of 22 patients, performance decrement in two patients, and medical reasons in one patient. The interval between the first and second CI ranged from 8 to 218 mo. Within-subject analysis showed the speech reception performance with the second CI to be significantly better than that with the first CI at all follow-up time points, with average within-patient gains of 17%, 16%, 12%, and 15% at 3 mo, 9 mo, 3 years, and the highest scores achieved, respectively. After reimplantation, the performance was better than the last results before reimplantation, and this was significant from 9 mo after reimplantation onwards. Three patients (14%) had a performance degradation with the second CI, which was probably owing to (1) difficulties in reimplantation surgery leading to a reduced number of active channels, (2) insufficient experience with the second CI as the reimplantation has been performed recently, and (3) advanced fenestral and retrofenestral otosclerosis. Conclusions: The present study shows that speech reception performance after reimplantation yields faster and better results than the first implant. It takes a couple of months to get better results than those before the reimplantation. Only in a minority of participants, a small deterioration may be observed. It seems that soft failures in the absence of measurable technical abnormalities call for caution with regard to reimplantation.
- 3 January 2021
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 278 (12) , 4671-4679
Variability of fitting parameters across cochlear implant centres
Objective As a follow-up to the studies by Vaerenberg et al. (Sci World J 501738:1–12, 2014) and Browning et al. (Cochlear Implant Int 21(3):1–13, 2020), who used questionnaires, we determined whether there are between-centre variations in the fitting of cochlear implants by analysing the methodology, fitting parameters and hearing results of patients from four centres with real data. The purpose of this study is to highlight the lack of streamlined mapping guides and outcome measures with respect to cochlear implant (CI) fittings. Methods A retrospective study with ninety-seven post-lingual adults with a nucleus cochlear implant placed between 2003 and 2013 was included to ensure at least 5 years of follow-up. The studied data were as follows: the methodology, including the fitter’s professional background, the method of activation, the sequence of fitting sessions, the objectives measures and hearing outcomes; and the fitting parameters, including the speech processors, programming strategy, stimulation mode, T and C levels, T-SPL and C-SPL, maxima, pulse width, loudness growth and hearing results. Results This investigation highlights some common practices across professionals and CI centres: the activation of a CI is behavioural; impedances are systematically measured at each fitting; and some parameters are rarely modified. However, there are also differences, either between centres, such as the sequences of fitting sessions (p < 0.05) or their approach to spectral bands (p < 0.05), or even within centres, such as the policy regarding T and C levels at high frequencies compared to those at low and mid-frequencies. Conclusion There are important variations between and within centres that reflect a lack of CI-related policies and outcome measures in the fitting of CI. Clinical trials registry NCT03700268
- 3 January 2021
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 278 (12) , 4671-4679
Variability of fitting parameters across cochlear implant centres
Objective As a follow-up to the studies by Vaerenberg et al. (Sci World J 501738:1–12, 2014) and Browning et al. (Cochlear Implant Int 21(3):1–13, 2020), who used questionnaires, we determined whether there are between-centre variations in the fitting of cochlear implants by analysing the methodology, fitting parameters and hearing results of patients from four centres with real data. The purpose of this study is to highlight the lack of streamlined mapping guides and outcome measures with respect to cochlear implant (CI) fittings. Methods A retrospective study with ninety-seven post-lingual adults with a nucleus cochlear implant placed between 2003 and 2013 was included to ensure at least 5 years of follow-up. The studied data were as follows: the methodology, including the fitter’s professional background, the method of activation, the sequence of fitting sessions, the objectives measures and hearing outcomes; and the fitting parameters, including the speech processors, programming strategy, stimulation mode, T and C levels, T-SPL and C-SPL, maxima, pulse width, loudness growth and hearing results. Results This investigation highlights some common practices across professionals and CI centres: the activation of a CI is behavioural; impedances are systematically measured at each fitting; and some parameters are rarely modified. However, there are also differences, either between centres, such as the sequences of fitting sessions (p < 0.05) or their approach to spectral bands (p < 0.05), or even within centres, such as the policy regarding T and C levels at high frequencies compared to those at low and mid-frequencies. Conclusion There are important variations between and within centres that reflect a lack of CI-related policies and outcome measures in the fitting of CI. Clinical trials registry NCT03700268
- Open Access
- 5 June 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (6) , 1758
Speech Perception Changes in the Acoustically Aided, Nonimplanted Ear after Cochlear Implantation: A Multicenter Study
In recent years there has been an increasing percentage of cochlear implant (CI) users who have usable residual hearing in the contralateral, nonimplanted ear, typically aided by acoustic amplification. This raises the issue of the extent to which the signal presented through the cochlear implant may influence how listeners process information in the acoustically stimulated ear. This multicenter retrospective study examined pre- to postoperative changes in speech perception in the nonimplanted ear, the implanted ear, and both together. Results in the latter two conditions showed the expected increases, but speech perception in the nonimplanted ear showed a modest yet meaningful decrease that could not be completely explained by changes in unaided thresholds, hearing aid malfunction, or several other demographic variables. Decreases in speech perception in the nonimplanted ear were more likely in individuals who had better levels of speech perception in the implanted ear, and in those who had better speech perception in the implanted than in the nonimplanted ear. This raises the possibility that, in some cases, bimodal listeners may rely on the higher quality signal provided by the implant and may disregard or even neglect the input provided by the nonimplanted ear.
- 5 June 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (6) , 1758
Open AccessSpeech Perception Changes in the Acoustically Aided, Nonimplanted Ear after Cochlear Implantation: A Multicenter Study
In recent years there has been an increasing percentage of cochlear implant (CI) users who have usable residual hearing in the contralateral, nonimplanted ear, typically aided by acoustic amplification. This raises the issue of the extent to which the signal presented through the cochlear implant may influence how listeners process information in the acoustically stimulated ear. This multicenter retrospective study examined pre- to postoperative changes in speech perception in the nonimplanted ear, the implanted ear, and both together. Results in the latter two conditions showed the expected increases, but speech perception in the nonimplanted ear showed a modest yet meaningful decrease that could not be completely explained by changes in unaided thresholds, hearing aid malfunction, or several other demographic variables. Decreases in speech perception in the nonimplanted ear were more likely in individuals who had better levels of speech perception in the implanted ear, and in those who had better speech perception in the implanted than in the nonimplanted ear. This raises the possibility that, in some cases, bimodal listeners may rely on the higher quality signal provided by the implant and may disregard or even neglect the input provided by the nonimplanted ear.
- 13 May 2020
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 21 (5) , 260-268
Cochlear implant telemedicine: Remote fitting based on psychoacoustic self-tests and artificial intelligence
Objective: This study aims to assess the feasibility of autonomous cochlear implant (CI) fitting by adult CI recipients based on psychoacoustic self-testing and artificial intelligence (AI). Design: A feasibility study was performed on six adult CI recipients implanted with a Nucleus device. Two weeks after processor activation in the clinic, a ‘self-fitting’ session was organized in a supervised simulated home environment. The CI recipient performed pure tone audiometry and spectral discrimination tests as self-tests. The AI application FOX analysed the results and recommended a new map. The participants filled out a questionnaire and were tested again after 2 months of take-home experience. Results: Four out of six patients performed the self-tests without any help from the audiologist and four were fitted by FOX without any manual intervention. All patients were comfortable with the concept of self-testing and automated fitting. Patients acknowledged that at this stage the remote supervision of an audiologist remains essential. Conclusions: The study showed that audiological self-assessment and remote CI fitting with AI under the supervision of an audiologist is feasible, at least in a number of CI recipients. Currently, there are still some technical and regulatory challenges to be addressed before this can become routine practice.
- 13 May 2020
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 21 (5) , 260-268
Cochlear implant telemedicine: Remote fitting based on psychoacoustic self-tests and artificial intelligence
Objective: This study aims to assess the feasibility of autonomous cochlear implant (CI) fitting by adult CI recipients based on psychoacoustic self-testing and artificial intelligence (AI). Design: A feasibility study was performed on six adult CI recipients implanted with a Nucleus device. Two weeks after processor activation in the clinic, a ‘self-fitting’ session was organized in a supervised simulated home environment. The CI recipient performed pure tone audiometry and spectral discrimination tests as self-tests. The AI application FOX analysed the results and recommended a new map. The participants filled out a questionnaire and were tested again after 2 months of take-home experience. Results: Four out of six patients performed the self-tests without any help from the audiologist and four were fitted by FOX without any manual intervention. All patients were comfortable with the concept of self-testing and automated fitting. Patients acknowledged that at this stage the remote supervision of an audiologist remains essential. Conclusions: The study showed that audiological self-assessment and remote CI fitting with AI under the supervision of an audiologist is feasible, at least in a number of CI recipients. Currently, there are still some technical and regulatory challenges to be addressed before this can become routine practice.
- 2 September 2019
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 21 (5) , 299-305
From manual to artificial intelligence fitting: Two cochlear implant case studies
Objective: To assess whether CI programming by means of a software application using artificial intelligence (AI), FOX®, may improve cochlear implant (CI) performance. Patients: Two adult CI recipients who had mixed auditory results with their manual fitting were selected for an AI-assisted fitting. Even after 17 months CI experience and 19 manual fitting sessions, the first subject hadn’t developed open set word recognition. The second subject, after 9 months of manual fitting, had developed good open set word recognition, but his scores remained poor at soft and loud presentation levels. Main outcome measure(s): Cochlear implant fitting parameters, pure tone thresholds, bisyllabic word recognition, phonemic discrimination scores and loudness scaling curves. Results: For subject 1, a first approach trying to optimize the home maps by means of AI-proposed adaptations was not successful whereas a second approach based on the use of Automaps (an AI approach based on universal, i.e. population based group statistics) during 3 months allowed the development of open set word recognition. For subject 2, the word recognition scores improved at soft and loud intensities with the AI suggestions. The AI-suggested modifications seem to be atypical. Conclusions: The two case studies illustrate that adults implanted with manual CI fitting may experience an improvement in their auditory results with AI-assisted fitting.
- 2 September 2019
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 21 (5) , 299-305
From manual to artificial intelligence fitting: Two cochlear implant case studies
Objective: To assess whether CI programming by means of a software application using artificial intelligence (AI), FOX®, may improve cochlear implant (CI) performance. Patients: Two adult CI recipients who had mixed auditory results with their manual fitting were selected for an AI-assisted fitting. Even after 17 months CI experience and 19 manual fitting sessions, the first subject hadn’t developed open set word recognition. The second subject, after 9 months of manual fitting, had developed good open set word recognition, but his scores remained poor at soft and loud presentation levels. Main outcome measure(s): Cochlear implant fitting parameters, pure tone thresholds, bisyllabic word recognition, phonemic discrimination scores and loudness scaling curves. Results: For subject 1, a first approach trying to optimize the home maps by means of AI-proposed adaptations was not successful whereas a second approach based on the use of Automaps (an AI approach based on universal, i.e. population based group statistics) during 3 months allowed the development of open set word recognition. For subject 2, the word recognition scores improved at soft and loud intensities with the AI suggestions. The AI-suggested modifications seem to be atypical. Conclusions: The two case studies illustrate that adults implanted with manual CI fitting may experience an improvement in their auditory results with AI-assisted fitting.
- 27 August 2019
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 20 (6) , 299-311
Speech polar plots for different directionality settings of SONNET cochlear implant processor
Objectives: The newest CI processor from MED-EL company, the SONNET, has two new directional microphone settings. Besides the Omnidirectional microphone mode, it has the possibility to switch to Natural or Adaptive directionality. Both new modes favour perception of sound coming from a front-facing direction compared to sounds from sources at alternate azimuths. Natural directionality mimics the pinna effect of the normal external ear. Design: We undertook to verify the effect of these options in vivo by means of clinical audiological tests. Speech reception thresholds were successively measured for a variety of speech presentation azimuths while keeping the noise azimuths constant. Complete ‘Speech Reception Threshold (SRT)-Polar-Plots’ were obtained from these data for the Omnidirectional and Natural directionality modes of the SONNET. In addition, one ‘SRT-point’ was also measured in the ‘Adaptive’ mode for speech coming from 45° azimuth. Study sample: A group of 13 adult CI recipients participated. Only one of these subjects had previous experience with the SONNET processor. Results: Complete ‘SRT-Polar-Plots’ could be measured in Natural and Omnidirectional modes in CI recipients within an acceptable timeframe. The pinna-following directionality for Natural mode could be confirmed. Median SRT in noise for speech coming from the 45° azimuth speaker was −5.6 dB SNR for Omnidirectional, −9.1 dB SNR for Natural and −12.8 dB SNR for Adaptive microphone. Natural and Adaptive significantly improved performance compared to Omnidirectional mode at this optimal azimuth of 45° with a median improvement in SRT of 3.5 and 7.2 dB respectively. Conclusions: A novel audiological method, ‘SRT-Polar-Plot’, was developed and described. Significant directionality benefits for Natural and Adaptive mode were confirmed in vivo using this technique.
- 27 August 2019
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 20 (6) , 299-311
Speech polar plots for different directionality settings of SONNET cochlear implant processor
Objectives: The newest CI processor from MED-EL company, the SONNET, has two new directional microphone settings. Besides the Omnidirectional microphone mode, it has the possibility to switch to Natural or Adaptive directionality. Both new modes favour perception of sound coming from a front-facing direction compared to sounds from sources at alternate azimuths. Natural directionality mimics the pinna effect of the normal external ear. Design: We undertook to verify the effect of these options in vivo by means of clinical audiological tests. Speech reception thresholds were successively measured for a variety of speech presentation azimuths while keeping the noise azimuths constant. Complete ‘Speech Reception Threshold (SRT)-Polar-Plots’ were obtained from these data for the Omnidirectional and Natural directionality modes of the SONNET. In addition, one ‘SRT-point’ was also measured in the ‘Adaptive’ mode for speech coming from 45° azimuth. Study sample: A group of 13 adult CI recipients participated. Only one of these subjects had previous experience with the SONNET processor. Results: Complete ‘SRT-Polar-Plots’ could be measured in Natural and Omnidirectional modes in CI recipients within an acceptable timeframe. The pinna-following directionality for Natural mode could be confirmed. Median SRT in noise for speech coming from the 45° azimuth speaker was −5.6 dB SNR for Omnidirectional, −9.1 dB SNR for Natural and −12.8 dB SNR for Adaptive microphone. Natural and Adaptive significantly improved performance compared to Omnidirectional mode at this optimal azimuth of 45° with a median improvement in SRT of 3.5 and 7.2 dB respectively. Conclusions: A novel audiological method, ‘SRT-Polar-Plot’, was developed and described. Significant directionality benefits for Natural and Adaptive mode were confirmed in vivo using this technique.
- 11 July 2017
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 56 (11) , 837-843
The use of cochlear's SCAN and wireless microphones to improve speech understanding in noise with the Nucleus6® CP900 processor
Objectives: The newest Nucleus CI processor, the CP900, has two new options to improve speech-in-noise perception: (1) use of an adaptive directional microphone (SCAN mode) and (2) wireless connection to MiniMic1 and MiniMic2 wireless remote microphones. Design: An analysis was made of the absolute and relative benefits of these technologies in a real-world mimicking test situation. Speech perception was tested using an adaptive speech-in-noise test (sentences-in-babble noise). In session A, SRTs were measured in three conditions: (1) Clinical Map, (2) SCAN and (3) MiniMic1. Each was assessed for three distances between speakers and CI recipient: 1 m, 2 m and 3 m. In session B, the benefit of the use of MiniMic2 was compared to benefit of MiniMic1 at 3 m. Study sample: A group of 13 adult CP900 recipients participated. Results: SCAN and MiniMic1 improved performance compared to the standard microphone with a median improvement in SRT of 2.7–3.9 dB for SCAN at 1 m and 3 m, respectively, and 4.7–10.9 dB for the MiniMic1. MiniMic1 improvements were significant. MiniMic2 showed an improvement in SRT of 22.2 dB compared to 10.0 dB for MiniMic1 (3 m). Conclusions: Digital wireless transmission systems (i.e. MiniMic) offer a statistically and clinically significant improvement in speech perception in challenging, realistic listening conditions.
- 11 July 2017
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 56 (11) , 837-843
The use of cochlear's SCAN and wireless microphones to improve speech understanding in noise with the Nucleus6® CP900 processor
Objectives: The newest Nucleus CI processor, the CP900, has two new options to improve speech-in-noise perception: (1) use of an adaptive directional microphone (SCAN mode) and (2) wireless connection to MiniMic1 and MiniMic2 wireless remote microphones. Design: An analysis was made of the absolute and relative benefits of these technologies in a real-world mimicking test situation. Speech perception was tested using an adaptive speech-in-noise test (sentences-in-babble noise). In session A, SRTs were measured in three conditions: (1) Clinical Map, (2) SCAN and (3) MiniMic1. Each was assessed for three distances between speakers and CI recipient: 1 m, 2 m and 3 m. In session B, the benefit of the use of MiniMic2 was compared to benefit of MiniMic1 at 3 m. Study sample: A group of 13 adult CP900 recipients participated. Results: SCAN and MiniMic1 improved performance compared to the standard microphone with a median improvement in SRT of 2.7–3.9 dB for SCAN at 1 m and 3 m, respectively, and 4.7–10.9 dB for the MiniMic1. MiniMic1 improvements were significant. MiniMic2 showed an improvement in SRT of 22.2 dB compared to 10.0 dB for MiniMic1 (3 m). Conclusions: Digital wireless transmission systems (i.e. MiniMic) offer a statistically and clinically significant improvement in speech perception in challenging, realistic listening conditions.
- Open Access
- 3 May 2017
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 18 (4) , 198-206
Computer-assisted CI fitting: Is the learning capacity of the intelligent agent FOX beneficial for speech understanding?
Objective: The software application FOX (‘Fitting to Outcome eXpert’) is an intelligent agent to assist in the programing of cochlear implant (CI) processors. The current version utilizes a mixture of deterministic and probabilistic logic which is able to improve over time through a learning effect. This study aimed at assessing whether this learning capacity yields measurable improvements in speech understanding. Methods: A retrospective study was performed on 25 consecutive CI recipients with a median CI use experience of 10 years who came for their annual CI follow-up fitting session. All subjects were assessed by means of speech audiometry with open set monosyllables at 40, 55, 70, and 85 dB SPL in quiet with their home MAP. Other psychoacoustic tests were executed depending on the audiologist's clinical judgment. The home MAP and the corresponding test results were entered into FOX. If FOX suggested to make MAP changes, they were implemented and another speech audiometry was performed with the new MAP. Results: FOX suggested MAP changes in 21 subjects (84%). The within-subject comparison showed a significant median improvement of 10, 3, 1, and 7% at 40, 55, 70, and 85 dB SPL, respectively. All but two subjects showed an instantaneous improvement in their mean speech audiometric score. Discussion: Persons with long-term CI use, who received a FOX-assisted CI fitting at least 6 months ago, display improved speech understanding after MAP modifications, as recommended by the current version of FOX. This can be explained only by intrinsic improvements in FOX's algorithms, as they have resulted from learning. This learning is an inherent feature of artificial intelligence and it may yield measurable benefit in speech understanding even in long-term CI recipients.
- 3 May 2017
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 18 (4) , 198-206
Open AccessComputer-assisted CI fitting: Is the learning capacity of the intelligent agent FOX beneficial for speech understanding?
Objective: The software application FOX (‘Fitting to Outcome eXpert’) is an intelligent agent to assist in the programing of cochlear implant (CI) processors. The current version utilizes a mixture of deterministic and probabilistic logic which is able to improve over time through a learning effect. This study aimed at assessing whether this learning capacity yields measurable improvements in speech understanding. Methods: A retrospective study was performed on 25 consecutive CI recipients with a median CI use experience of 10 years who came for their annual CI follow-up fitting session. All subjects were assessed by means of speech audiometry with open set monosyllables at 40, 55, 70, and 85 dB SPL in quiet with their home MAP. Other psychoacoustic tests were executed depending on the audiologist's clinical judgment. The home MAP and the corresponding test results were entered into FOX. If FOX suggested to make MAP changes, they were implemented and another speech audiometry was performed with the new MAP. Results: FOX suggested MAP changes in 21 subjects (84%). The within-subject comparison showed a significant median improvement of 10, 3, 1, and 7% at 40, 55, 70, and 85 dB SPL, respectively. All but two subjects showed an instantaneous improvement in their mean speech audiometric score. Discussion: Persons with long-term CI use, who received a FOX-assisted CI fitting at least 6 months ago, display improved speech understanding after MAP modifications, as recommended by the current version of FOX. This can be explained only by intrinsic improvements in FOX's algorithms, as they have resulted from learning. This learning is an inherent feature of artificial intelligence and it may yield measurable benefit in speech understanding even in long-term CI recipients.
- Open Access
- 18 October 2016
- Published by Wiley in BioMed Research International
- Vol. 2016, 1-14
Linguistic Factors Influencing Speech Audiometric Assessment
In speech audiometric testing, hearing performance is typically measured by calculating the number of correct repetitions of a speech stimulus. We investigate to what extent the repetition accuracy of Dutch speech stimuli presented against a background noise is influenced by nonauditory processes. We show that variation in verbal repetition accuracy is partially explained by morpholexical and syntactic features of the target language. Verbs, prepositions, conjunctions, determiners, and pronouns yield significantly lower correct repetitions than nouns, adjectives, or adverbs. The reduced repetition performance for verbs and function words is probably best explained by the similarities in the perceptual nature of verbal morphology and function words in Dutch. For sentences, an overall negative effect of syntactic complexity on speech repetition accuracy was found. The lowest number of correct repetitions was obtained with passive sentences, reflecting the cognitive cost of processing a noncanonical sentence structure. Taken together, these findings may have important implications for the audiological practice. In combination with hearing loss, linguistic complexity may increase the cognitive demands to process sentences in noise, leading to suboptimal functional hearing in day-to-day listening situations. Using test sentences with varying degrees of syntactic complexity may therefore provide useful information to measure functional hearing benefits.
- 18 October 2016
- Published by Wiley in BioMed Research International
- Vol. 2016, 1-14
Open AccessLinguistic Factors Influencing Speech Audiometric Assessment
In speech audiometric testing, hearing performance is typically measured by calculating the number of correct repetitions of a speech stimulus. We investigate to what extent the repetition accuracy of Dutch speech stimuli presented against a background noise is influenced by nonauditory processes. We show that variation in verbal repetition accuracy is partially explained by morpholexical and syntactic features of the target language. Verbs, prepositions, conjunctions, determiners, and pronouns yield significantly lower correct repetitions than nouns, adjectives, or adverbs. The reduced repetition performance for verbs and function words is probably best explained by the similarities in the perceptual nature of verbal morphology and function words in Dutch. For sentences, an overall negative effect of syntactic complexity on speech repetition accuracy was found. The lowest number of correct repetitions was obtained with passive sentences, reflecting the cognitive cost of processing a noncanonical sentence structure. Taken together, these findings may have important implications for the audiological practice. In combination with hearing loss, linguistic complexity may increase the cognitive demands to process sentences in noise, leading to suboptimal functional hearing in day-to-day listening situations. Using test sentences with varying degrees of syntactic complexity may therefore provide useful information to measure functional hearing benefits.