Rafaella Regina Alves Peixoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rafaella Regina Alves Peixoto has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
Solange Cadore
9 shared publications- Sonia Fernández-Menéndez
Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Oviedo, Spain
5 shared publications Belén Fernández-Colomer
4 shared publications- Christiane Duyck
Department of Analytical Chemistry, Federal Fluminense University (UFF), Niterói, 24020-141, Brazil
4 shared publications Alfredo Sanz-Medel
3 shared publications- Andrea Oliveira
Departamento de Química, Universidade Federal do Paraná, Curitiba CEP 81531-980, PR, Brazil
3 shared publications
Latest Publications
- 1 January 2026
- Published by Sociedade Brasileira de Quimica (SBQ) in Química Nova
FREQUENT ANALYTICAL QUESTIONS (FAQ) - 20 DÚVIDAS COMUNS EM QUÍMICA ANALÍTICA
FREQUENT ANALYTICAL QUESTIONS (FAQ) - 20 COMMON QUESTIONS IN ANALYTICAL CHEMISTRY. Twenty frequently asked questions in analytical chemistry are presented in a clear, instructive, and accessible manner. In the context of classical analysis, the text addresses questions related to types of solutions and their preparation, as well as key definitions of qualitative and quantitative methods, volumetric analysis, and heavy metals. It also covers essential topics such as analytical sequence, use of certified reference materials, distinctions among analytical methods, procedures, and techniques, and the main analytical figures of merit. Finally, fundamental aspects of instrumental analysis – including noise, background signals, detectability, detection and quantification limits, and calibration – are discussed, along with statistical considerations related to precision, linear modeling, and significance testing.
- 1 January 2026
- Published by Sociedade Brasileira de Quimica (SBQ) in Química Nova
FREQUENT ANALYTICAL QUESTIONS (FAQ) - 20 DÚVIDAS COMUNS EM QUÍMICA ANALÍTICA
FREQUENT ANALYTICAL QUESTIONS (FAQ) - 20 COMMON QUESTIONS IN ANALYTICAL CHEMISTRY. Twenty frequently asked questions in analytical chemistry are presented in a clear, instructive, and accessible manner. In the context of classical analysis, the text addresses questions related to types of solutions and their preparation, as well as key definitions of qualitative and quantitative methods, volumetric analysis, and heavy metals. It also covers essential topics such as analytical sequence, use of certified reference materials, distinctions among analytical methods, procedures, and techniques, and the main analytical figures of merit. Finally, fundamental aspects of instrumental analysis – including noise, background signals, detectability, detection and quantification limits, and calibration – are discussed, along with statistical considerations related to precision, linear modeling, and significance testing.
- 1 January 2025
- Published by Sociedade Brasileira de Quimica (SBQ) in Química Nova
DICROMATOMETRIA EM MICROESCALA: MOTIVAÇÃO PARA DIMINUIR OS IMPACTOS AMBIENTAIS NO ENSINO DA QUÍMICA ANALÍTICA
MICROSCALE DICHROMETRY: THE MOTIVATION FOR LOWERING THE ENVIRONMENTAL IMPACTS IN ANALYTICAL CHEMISTRY TEACHING. The introduction of the concepts of Green Analytical Chemistry in the teaching of Chemistry has been growing, in view of the formation of students more attentive to sustainable development. However, many experimental classes still employ reagents of high toxicity, which generate class I residues, as is the case of dichrometry, a titulometric method. Using the determination of iron in a dietary supplement and in a steel sponge as motivating examples, this paper presents microtitration as a greener alternative for classroom use. The method is compared to the classical approach, highlighting differences in chemical exposure and waste volume, emphasizing the environmental benefits of microtitration. The experiment allowed students to develop critical thinking about traditional methods and became familiar with the manipulation of microvolumes and microscale reasoning. Their evaluations of the proposed practice were recorded and discussed, for a possible replacement of the classical method.
- 1 January 2025
- Published by Sociedade Brasileira de Quimica (SBQ) in Química Nova
DICROMATOMETRIA EM MICROESCALA: MOTIVAÇÃO PARA DIMINUIR OS IMPACTOS AMBIENTAIS NO ENSINO DA QUÍMICA ANALÍTICA
MICROSCALE DICHROMETRY: THE MOTIVATION FOR LOWERING THE ENVIRONMENTAL IMPACTS IN ANALYTICAL CHEMISTRY TEACHING. The introduction of the concepts of Green Analytical Chemistry in the teaching of Chemistry has been growing, in view of the formation of students more attentive to sustainable development. However, many experimental classes still employ reagents of high toxicity, which generate class I residues, as is the case of dichrometry, a titulometric method. Using the determination of iron in a dietary supplement and in a steel sponge as motivating examples, this paper presents microtitration as a greener alternative for classroom use. The method is compared to the classical approach, highlighting differences in chemical exposure and waste volume, emphasizing the environmental benefits of microtitration. The experiment allowed students to develop critical thinking about traditional methods and became familiar with the manipulation of microvolumes and microscale reasoning. Their evaluations of the proposed practice were recorded and discussed, for a possible replacement of the classical method.
- 26 April 2024
- Published by Elsevier in Food Research International
- Vol. 187, 114431
Bioaccessibility and bioavailability of essential and potentially toxic trace elements in potato cultivars: A comprehensive nutritional evaluation
- 26 April 2024
- Published by Elsevier in Food Research International
- Vol. 187, 114431
Bioaccessibility and bioavailability of essential and potentially toxic trace elements in potato cultivars: A comprehensive nutritional evaluation
- 1 January 2023
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
Fit-for-Purpose MIP OES Method to Meet the Requirements of the Brazilian Regulations for K and Na in Coconut Water, and Nutritional Assessment
The Brazilian regulations for processed coconut water establish the range concentrations of Na and K, being necessary high-throughput analytical methods, as microwave-induced plasma optical emission spectrometry (MIP OES) for quality control. Samples of natural (green and mature) and processed coconut water were treated by acid decomposition assisted by microwave radiation before their MIP OES analysis. Recoveries for Na and K were 103 and 95%, whereas the relative standard deviation (RSDs) were 7.6 and 1.3%, respectively. The limit of detection (LOD) was 1.77 mg kg-1 for K and 2.31 mg kg-1 for Na. Sodium and K were determined in the ranges of, respectively, 27-490 and 1,600-3,500 mg L-1 in natural samples, whereas in processed samples the ranges were 26-168 and 814-2,054 mg L-1. K-means cluster analysis identified a group of processed samples with compositions similar to green coconut water. All the processed samples were in accordance with the established regulation, except one dehydrated sample for which K content was below the accepted range. Natural coconut water is an excellent source of K in the diet as its daily consumption can supply more than 20% of the recommended daily ingestion of K for adults and 30% for children.
- 1 January 2023
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
Fit-for-Purpose MIP OES Method to Meet the Requirements of the Brazilian Regulations for K and Na in Coconut Water, and Nutritional Assessment
The Brazilian regulations for processed coconut water establish the range concentrations of Na and K, being necessary high-throughput analytical methods, as microwave-induced plasma optical emission spectrometry (MIP OES) for quality control. Samples of natural (green and mature) and processed coconut water were treated by acid decomposition assisted by microwave radiation before their MIP OES analysis. Recoveries for Na and K were 103 and 95%, whereas the relative standard deviation (RSDs) were 7.6 and 1.3%, respectively. The limit of detection (LOD) was 1.77 mg kg-1 for K and 2.31 mg kg-1 for Na. Sodium and K were determined in the ranges of, respectively, 27-490 and 1,600-3,500 mg L-1 in natural samples, whereas in processed samples the ranges were 26-168 and 814-2,054 mg L-1. K-means cluster analysis identified a group of processed samples with compositions similar to green coconut water. All the processed samples were in accordance with the established regulation, except one dehydrated sample for which K content was below the accepted range. Natural coconut water is an excellent source of K in the diet as its daily consumption can supply more than 20% of the recommended daily ingestion of K for adults and 30% for children.
- 27 January 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (3) , 474-496
Aerosol dilution for the introduction of complex matrix samples in plasma-based spectrometry techniques: a tutorial review
Aerosol dilution (AD) is a sample introduction tool that allows the direct analysis of complex matrix samples by plasma-based analytical techniques. In AD, a controlled gas stream (dilution gas) is added at the tertiary aerosol zone, between the spray chamber and the torch. As a result of the dilution of the aerosol, there is an improvement in plasma matrix tolerance and plasma robustness, when compared with pneumatic nebulization without AD. Therefore, solutions with higher total dissolved solids can be introduced with minimal sample treatment for the determination of trace and ultra-trace elements. The use of AD also brings other benefits such as minimization of dilution errors, liquid waste, and sample contamination. A review of the application of AD was conducted, considering more than one hundred papers. An increase in the number of publications was observed after the introduction of AD ICP-MS integrated systems. The effects of AD on plasma, analytical signal, signal/background ratio, and interferences were examined. Strategies for AD ICP-MS optimization that led to its best performance monitored other parameters, such as plasma applied power and sampling depth, in conjunction with the dilution gas flow rate, while maintaining a sum of nebulizer gas and dilution gas flow rates around 1 L min−1. Additionally, improved operational conditions were obtained by using the signal/background ratio instead of the net signal intensity of analytes. Applications of AD for the analysis of food, environmental, geological, pharmaceutical, biological and clinical samples are also exemplified and discussed. In future studies, AD should be deeper exploited in optical emission spectrometry, chemical speciation, single particle, and laser ablation-based analysis.
- 27 January 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (3) , 474-496
Aerosol dilution for the introduction of complex matrix samples in plasma-based spectrometry techniques: a tutorial review
Aerosol dilution (AD) is a sample introduction tool that allows the direct analysis of complex matrix samples by plasma-based analytical techniques. In AD, a controlled gas stream (dilution gas) is added at the tertiary aerosol zone, between the spray chamber and the torch. As a result of the dilution of the aerosol, there is an improvement in plasma matrix tolerance and plasma robustness, when compared with pneumatic nebulization without AD. Therefore, solutions with higher total dissolved solids can be introduced with minimal sample treatment for the determination of trace and ultra-trace elements. The use of AD also brings other benefits such as minimization of dilution errors, liquid waste, and sample contamination. A review of the application of AD was conducted, considering more than one hundred papers. An increase in the number of publications was observed after the introduction of AD ICP-MS integrated systems. The effects of AD on plasma, analytical signal, signal/background ratio, and interferences were examined. Strategies for AD ICP-MS optimization that led to its best performance monitored other parameters, such as plasma applied power and sampling depth, in conjunction with the dilution gas flow rate, while maintaining a sum of nebulizer gas and dilution gas flow rates around 1 L min−1. Additionally, improved operational conditions were obtained by using the signal/background ratio instead of the net signal intensity of analytes. Applications of AD for the analysis of food, environmental, geological, pharmaceutical, biological and clinical samples are also exemplified and discussed. In future studies, AD should be deeper exploited in optical emission spectrometry, chemical speciation, single particle, and laser ablation-based analysis.
- Open Access
- 1 February 2020
- Published by Elsevier in Journal of Functional Foods
- Vol. 65
Phosphorus and zinc are less bioaccessible in soy-based beverages in comparison to bovine milk
- 1 February 2020
- Published by Elsevier in Journal of Functional Foods
- Vol. 65
Open AccessPhosphorus and zinc are less bioaccessible in soy-based beverages in comparison to bovine milk