Georgina Elizabeth King
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Georgina Elizabeth King has a total of 153 co-authors. Here are the top co-authors by number of shared publications:
Frédéric Herman
Institute of Earth Surface Dynamics, University of Lausanne, Switzerland
14 shared publications- Melanie Bartz
Institute of Earth Surface Dynamics, University of Lausanne, Switzerland
11 shared publications - Benny Guralnik
Institute of Earth Surface Dynamics, University of Lausanne, Lausanne, 1015, Switzerland
10 shared publications - Frédéric Herman
Institute of Earth Surface Dynamics, University of Lausanne, Lausanne, Switzerland
10 shared publications - Shigeru Sueoka
Tono Geoscience Center, Japan Atomic Energy Agency, Toki, Japan
10 shared publications Pierre G. Valla
Institute of Earth Surface Dynamics, University of Lausanne, Lausanne, 1015, Switzerland
9 shared publications
Latest Publications
- Open Access
- 17 September 2026
- Published by Elsevier in Quaternary Geochronology
- Vol. 96
Dose rate and age calculator (DRAC v1.3): An update
- 17 September 2026
- Published by Elsevier in Quaternary Geochronology
- Vol. 96
Open AccessDose rate and age calculator (DRAC v1.3): An update
- Open Access
- 7 July 2026
- Published by Copernicus GmbH
- p. 1-19
Reply on RC2
The electron spin resonance (ESR) of quartz can be used as a low temperature thermochronometric system, however, to date no field validation of the approach has been made. Here we explore the ESR signals of quartz from six samples from the MIZ1 borehole (Tono, Japan). Previous studies have shown that this low-relief region underwent Quaternary exhumation at rates of -1. We investigate whether quartz ESR signals can resolve such low rates of exhumation, or whether the samples are in thermal equilibrium with ambient borehole temperature. ESR thermochronometry requires that both sample-specific signal saturation and thermal decay are constrained in the laboratory, which makes measurements highly time-consuming. To overcome this, the development of a standardised growth curve (SGC) was explored, which allowed more rapid constraint of the trapped-charge concentrations of each of the samples. Thermal kinetic parameters were determined using an isothermal decay experiment for each individual sample and except for sample MIZ1-08, it was possible to fit all the isothermal decay data together to yield a single set of kinetic parameters that successfully described the dataset. The ESR thermochronometry results show that the MIZ1 samples are in thermal equilibrium for the Al-centre, and that Monte-Carlo inversion of the ESR data yields present-day borehole temperature within 1σ uncertainties for all samples except the lowest temperature sample. In contrast, inversion of the different Ti-centre options (A, B, D) yields temperatures 15–20 °C above contemporary borehole temperature, indicating rock cooling equivalent to a total exhumation of ~1 km over the same period. The cause of this discrepancy is unclear but may relate to sub-linearity of Ti-centre dose response, that led to underestimation of the trapped-charge concentration and hence an overestimation of borehole temperature. Our results validate ESR-thermochronometry of the Al-centre and show that an SGC and common thermal kinetic parameters may be used to expediate sample measurements, however ESR-thermochronometric data from the Ti-centre should be used cautiously until further validation data are available.
- 7 July 2026
- Published by Copernicus GmbH
- p. 1-19
Open AccessReply on RC2
The electron spin resonance (ESR) of quartz can be used as a low temperature thermochronometric system, however, to date no field validation of the approach has been made. Here we explore the ESR signals of quartz from six samples from the MIZ1 borehole (Tono, Japan). Previous studies have shown that this low-relief region underwent Quaternary exhumation at rates of -1. We investigate whether quartz ESR signals can resolve such low rates of exhumation, or whether the samples are in thermal equilibrium with ambient borehole temperature. ESR thermochronometry requires that both sample-specific signal saturation and thermal decay are constrained in the laboratory, which makes measurements highly time-consuming. To overcome this, the development of a standardised growth curve (SGC) was explored, which allowed more rapid constraint of the trapped-charge concentrations of each of the samples. Thermal kinetic parameters were determined using an isothermal decay experiment for each individual sample and except for sample MIZ1-08, it was possible to fit all the isothermal decay data together to yield a single set of kinetic parameters that successfully described the dataset. The ESR thermochronometry results show that the MIZ1 samples are in thermal equilibrium for the Al-centre, and that Monte-Carlo inversion of the ESR data yields present-day borehole temperature within 1σ uncertainties for all samples except the lowest temperature sample. In contrast, inversion of the different Ti-centre options (A, B, D) yields temperatures 15–20 °C above contemporary borehole temperature, indicating rock cooling equivalent to a total exhumation of ~1 km over the same period. The cause of this discrepancy is unclear but may relate to sub-linearity of Ti-centre dose response, that led to underestimation of the trapped-charge concentration and hence an overestimation of borehole temperature. Our results validate ESR-thermochronometry of the Al-centre and show that an SGC and common thermal kinetic parameters may be used to expediate sample measurements, however ESR-thermochronometric data from the Ti-centre should be used cautiously until further validation data are available.
- Open Access
- 7 July 2026
- Published by Copernicus GmbH
- p. 1-19
Reply on RC1
The electron spin resonance (ESR) of quartz can be used as a low temperature thermochronometric system, however, to date no field validation of the approach has been made. Here we explore the ESR signals of quartz from six samples from the MIZ1 borehole (Tono, Japan). Previous studies have shown that this low-relief region underwent Quaternary exhumation at rates of -1. We investigate whether quartz ESR signals can resolve such low rates of exhumation, or whether the samples are in thermal equilibrium with ambient borehole temperature. ESR thermochronometry requires that both sample-specific signal saturation and thermal decay are constrained in the laboratory, which makes measurements highly time-consuming. To overcome this, the development of a standardised growth curve (SGC) was explored, which allowed more rapid constraint of the trapped-charge concentrations of each of the samples. Thermal kinetic parameters were determined using an isothermal decay experiment for each individual sample and except for sample MIZ1-08, it was possible to fit all the isothermal decay data together to yield a single set of kinetic parameters that successfully described the dataset. The ESR thermochronometry results show that the MIZ1 samples are in thermal equilibrium for the Al-centre, and that Monte-Carlo inversion of the ESR data yields present-day borehole temperature within 1σ uncertainties for all samples except the lowest temperature sample. In contrast, inversion of the different Ti-centre options (A, B, D) yields temperatures 15–20 °C above contemporary borehole temperature, indicating rock cooling equivalent to a total exhumation of ~1 km over the same period. The cause of this discrepancy is unclear but may relate to sub-linearity of Ti-centre dose response, that led to underestimation of the trapped-charge concentration and hence an overestimation of borehole temperature. Our results validate ESR-thermochronometry of the Al-centre and show that an SGC and common thermal kinetic parameters may be used to expediate sample measurements, however ESR-thermochronometric data from the Ti-centre should be used cautiously until further validation data are available.
- 7 July 2026
- Published by Copernicus GmbH
- p. 1-19
Open AccessReply on RC1
The electron spin resonance (ESR) of quartz can be used as a low temperature thermochronometric system, however, to date no field validation of the approach has been made. Here we explore the ESR signals of quartz from six samples from the MIZ1 borehole (Tono, Japan). Previous studies have shown that this low-relief region underwent Quaternary exhumation at rates of -1. We investigate whether quartz ESR signals can resolve such low rates of exhumation, or whether the samples are in thermal equilibrium with ambient borehole temperature. ESR thermochronometry requires that both sample-specific signal saturation and thermal decay are constrained in the laboratory, which makes measurements highly time-consuming. To overcome this, the development of a standardised growth curve (SGC) was explored, which allowed more rapid constraint of the trapped-charge concentrations of each of the samples. Thermal kinetic parameters were determined using an isothermal decay experiment for each individual sample and except for sample MIZ1-08, it was possible to fit all the isothermal decay data together to yield a single set of kinetic parameters that successfully described the dataset. The ESR thermochronometry results show that the MIZ1 samples are in thermal equilibrium for the Al-centre, and that Monte-Carlo inversion of the ESR data yields present-day borehole temperature within 1σ uncertainties for all samples except the lowest temperature sample. In contrast, inversion of the different Ti-centre options (A, B, D) yields temperatures 15–20 °C above contemporary borehole temperature, indicating rock cooling equivalent to a total exhumation of ~1 km over the same period. The cause of this discrepancy is unclear but may relate to sub-linearity of Ti-centre dose response, that led to underestimation of the trapped-charge concentration and hence an overestimation of borehole temperature. Our results validate ESR-thermochronometry of the Al-centre and show that an SGC and common thermal kinetic parameters may be used to expediate sample measurements, however ESR-thermochronometric data from the Ti-centre should be used cautiously until further validation data are available.
- Open Access
- 22 June 2026
- Published by Elsevier in Earth and Planetary Science Letters
- Vol. 690
The KTB monazite fission-track profile: initial insights into ultra-low temperature thermochronology from a natural laboratory
- 22 June 2026
- Published by Elsevier in Earth and Planetary Science Letters
- Vol. 690
Open AccessThe KTB monazite fission-track profile: initial insights into ultra-low temperature thermochronology from a natural laboratory
- Open Access
- 4 June 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Comment on egusphere-2026-2204
The electron spin resonance (ESR) of quartz can be used as a low temperature thermochronometric system, however, to date no field validation of the approach has been made. Here we explore the ESR signals of quartz from six samples from the MIZ1 borehole (Tono, Japan). Previous studies have shown that this low-relief region underwent Quaternary exhumation at rates of -1. We investigate whether quartz ESR signals can resolve such low rates of exhumation, or whether the samples are in thermal equilibrium with ambient borehole temperature. ESR thermochronometry requires that both sample-specific signal saturation and thermal decay are constrained in the laboratory, which makes measurements highly time-consuming. To overcome this, the development of a standardised growth curve (SGC) was explored, which allowed more rapid constraint of the trapped-charge concentrations of each of the samples. Thermal kinetic parameters were determined using an isothermal decay experiment for each individual sample and except for sample MIZ1-08, it was possible to fit all the isothermal decay data together to yield a single set of kinetic parameters that successfully described the dataset. The ESR thermochronometry results show that the MIZ1 samples are in thermal equilibrium for the Al-centre, and that Monte-Carlo inversion of the ESR data yields present-day borehole temperature within 1σ uncertainties for all samples except the lowest temperature sample. In contrast, inversion of the different Ti-centre options (A, B, D) yields temperatures 15–20 °C above contemporary borehole temperature, indicating rock cooling equivalent to a total exhumation of ~1 km over the same period. The cause of this discrepancy is unclear but may relate to sub-linearity of Ti-centre dose response, that led to underestimation of the trapped-charge concentration and hence an overestimation of borehole temperature. Our results validate ESR-thermochronometry of the Al-centre and show that an SGC and common thermal kinetic parameters may be used to expediate sample measurements, however ESR-thermochronometric data from the Ti-centre should be used cautiously until further validation data are available.
- 4 June 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Open AccessComment on egusphere-2026-2204
The electron spin resonance (ESR) of quartz can be used as a low temperature thermochronometric system, however, to date no field validation of the approach has been made. Here we explore the ESR signals of quartz from six samples from the MIZ1 borehole (Tono, Japan). Previous studies have shown that this low-relief region underwent Quaternary exhumation at rates of -1. We investigate whether quartz ESR signals can resolve such low rates of exhumation, or whether the samples are in thermal equilibrium with ambient borehole temperature. ESR thermochronometry requires that both sample-specific signal saturation and thermal decay are constrained in the laboratory, which makes measurements highly time-consuming. To overcome this, the development of a standardised growth curve (SGC) was explored, which allowed more rapid constraint of the trapped-charge concentrations of each of the samples. Thermal kinetic parameters were determined using an isothermal decay experiment for each individual sample and except for sample MIZ1-08, it was possible to fit all the isothermal decay data together to yield a single set of kinetic parameters that successfully described the dataset. The ESR thermochronometry results show that the MIZ1 samples are in thermal equilibrium for the Al-centre, and that Monte-Carlo inversion of the ESR data yields present-day borehole temperature within 1σ uncertainties for all samples except the lowest temperature sample. In contrast, inversion of the different Ti-centre options (A, B, D) yields temperatures 15–20 °C above contemporary borehole temperature, indicating rock cooling equivalent to a total exhumation of ~1 km over the same period. The cause of this discrepancy is unclear but may relate to sub-linearity of Ti-centre dose response, that led to underestimation of the trapped-charge concentration and hence an overestimation of borehole temperature. Our results validate ESR-thermochronometry of the Al-centre and show that an SGC and common thermal kinetic parameters may be used to expediate sample measurements, however ESR-thermochronometric data from the Ti-centre should be used cautiously until further validation data are available.
- Open Access
- 26 May 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Comment on egusphere-2026-2204
The electron spin resonance (ESR) of quartz can be used as a low temperature thermochronometric system, however, to date no field validation of the approach has been made. Here we explore the ESR signals of quartz from six samples from the MIZ1 borehole (Tono, Japan). Previous studies have shown that this low-relief region underwent Quaternary exhumation at rates of -1. We investigate whether quartz ESR signals can resolve such low rates of exhumation, or whether the samples are in thermal equilibrium with ambient borehole temperature. ESR thermochronometry requires that both sample-specific signal saturation and thermal decay are constrained in the laboratory, which makes measurements highly time-consuming. To overcome this, the development of a standardised growth curve (SGC) was explored, which allowed more rapid constraint of the trapped-charge concentrations of each of the samples. Thermal kinetic parameters were determined using an isothermal decay experiment for each individual sample and except for sample MIZ1-08, it was possible to fit all the isothermal decay data together to yield a single set of kinetic parameters that successfully described the dataset. The ESR thermochronometry results show that the MIZ1 samples are in thermal equilibrium for the Al-centre, and that Monte-Carlo inversion of the ESR data yields present-day borehole temperature within 1σ uncertainties for all samples except the lowest temperature sample. In contrast, inversion of the different Ti-centre options (A, B, D) yields temperatures 15–20 °C above contemporary borehole temperature, indicating rock cooling equivalent to a total exhumation of ~1 km over the same period. The cause of this discrepancy is unclear but may relate to sub-linearity of Ti-centre dose response, that led to underestimation of the trapped-charge concentration and hence an overestimation of borehole temperature. Our results validate ESR-thermochronometry of the Al-centre and show that an SGC and common thermal kinetic parameters may be used to expediate sample measurements, however ESR-thermochronometric data from the Ti-centre should be used cautiously until further validation data are available.
- 26 May 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-19
Open AccessComment on egusphere-2026-2204
The electron spin resonance (ESR) of quartz can be used as a low temperature thermochronometric system, however, to date no field validation of the approach has been made. Here we explore the ESR signals of quartz from six samples from the MIZ1 borehole (Tono, Japan). Previous studies have shown that this low-relief region underwent Quaternary exhumation at rates of -1. We investigate whether quartz ESR signals can resolve such low rates of exhumation, or whether the samples are in thermal equilibrium with ambient borehole temperature. ESR thermochronometry requires that both sample-specific signal saturation and thermal decay are constrained in the laboratory, which makes measurements highly time-consuming. To overcome this, the development of a standardised growth curve (SGC) was explored, which allowed more rapid constraint of the trapped-charge concentrations of each of the samples. Thermal kinetic parameters were determined using an isothermal decay experiment for each individual sample and except for sample MIZ1-08, it was possible to fit all the isothermal decay data together to yield a single set of kinetic parameters that successfully described the dataset. The ESR thermochronometry results show that the MIZ1 samples are in thermal equilibrium for the Al-centre, and that Monte-Carlo inversion of the ESR data yields present-day borehole temperature within 1σ uncertainties for all samples except the lowest temperature sample. In contrast, inversion of the different Ti-centre options (A, B, D) yields temperatures 15–20 °C above contemporary borehole temperature, indicating rock cooling equivalent to a total exhumation of ~1 km over the same period. The cause of this discrepancy is unclear but may relate to sub-linearity of Ti-centre dose response, that led to underestimation of the trapped-charge concentration and hence an overestimation of borehole temperature. Our results validate ESR-thermochronometry of the Al-centre and show that an SGC and common thermal kinetic parameters may be used to expediate sample measurements, however ESR-thermochronometric data from the Ti-centre should be used cautiously until further validation data are available.
- Open Access
- 23 April 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-19
ESR-thermochronometry of the MIZ1 borehole, Tono, Japan
The electron spin resonance (ESR) of quartz can be used as a low temperature thermochronometric system, however, to date no field validation of the approach has been made. Here we explore the ESR signals of quartz from six samples from the MIZ1 borehole (Tono, Japan). Previous studies have shown that this low-relief region underwent Quaternary exhumation at rates of -1. We investigate whether quartz ESR signals can resolve such low rates of exhumation, or whether the samples are in thermal equilibrium with ambient borehole temperature. ESR thermochronometry requires that both sample-specific signal saturation and thermal decay are constrained in the laboratory, which makes measurements highly time-consuming. To overcome this, the development of a standardised growth curve (SGC) was explored, which allowed more rapid constraint of the trapped-charge concentrations of each of the samples. Thermal kinetic parameters were determined using an isothermal decay experiment for each individual sample and except for sample MIZ1-08, it was possible to fit all the isothermal decay data together to yield a single set of kinetic parameters that successfully described the dataset. The ESR thermochronometry results show that the MIZ1 samples are in thermal equilibrium for the Al-centre, and that Monte-Carlo inversion of the ESR data yields present-day borehole temperature within 1σ uncertainties for all samples except the lowest temperature sample. In contrast, inversion of the different Ti-centre options (A, B, D) yields temperatures 15–20 °C above contemporary borehole temperature, indicating rock cooling equivalent to a total exhumation of ~1 km over the same period. The cause of this discrepancy is unclear but may relate to sub-linearity of Ti-centre dose response, that led to underestimation of the trapped-charge concentration and hence an overestimation of borehole temperature. Our results validate ESR-thermochronometry of the Al-centre and show that an SGC and common thermal kinetic parameters may be used to expediate sample measurements, however ESR-thermochronometric data from the Ti-centre should be used cautiously until further validation data are available.
- 23 April 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-19
Open AccessESR-thermochronometry of the MIZ1 borehole, Tono, Japan
The electron spin resonance (ESR) of quartz can be used as a low temperature thermochronometric system, however, to date no field validation of the approach has been made. Here we explore the ESR signals of quartz from six samples from the MIZ1 borehole (Tono, Japan). Previous studies have shown that this low-relief region underwent Quaternary exhumation at rates of -1. We investigate whether quartz ESR signals can resolve such low rates of exhumation, or whether the samples are in thermal equilibrium with ambient borehole temperature. ESR thermochronometry requires that both sample-specific signal saturation and thermal decay are constrained in the laboratory, which makes measurements highly time-consuming. To overcome this, the development of a standardised growth curve (SGC) was explored, which allowed more rapid constraint of the trapped-charge concentrations of each of the samples. Thermal kinetic parameters were determined using an isothermal decay experiment for each individual sample and except for sample MIZ1-08, it was possible to fit all the isothermal decay data together to yield a single set of kinetic parameters that successfully described the dataset. The ESR thermochronometry results show that the MIZ1 samples are in thermal equilibrium for the Al-centre, and that Monte-Carlo inversion of the ESR data yields present-day borehole temperature within 1σ uncertainties for all samples except the lowest temperature sample. In contrast, inversion of the different Ti-centre options (A, B, D) yields temperatures 15–20 °C above contemporary borehole temperature, indicating rock cooling equivalent to a total exhumation of ~1 km over the same period. The cause of this discrepancy is unclear but may relate to sub-linearity of Ti-centre dose response, that led to underestimation of the trapped-charge concentration and hence an overestimation of borehole temperature. Our results validate ESR-thermochronometry of the Al-centre and show that an SGC and common thermal kinetic parameters may be used to expediate sample measurements, however ESR-thermochronometric data from the Ti-centre should be used cautiously until further validation data are available.
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Putting rates on the buzz-saw? Constraining the timing and rate of cirque valley incision, Rhône valley, Switzerland.
The observation that topography trends with snowline altitude despite large differences in tectonic uplift in various locations provides the foundation of the glacial buzz-saw hypothesis. However, despite numerous modelling studies, very few quantitative data are available that document the timing or rate of glacial topography formation. Consequently, challenges remain to explain why some localities (e.g. Alaska, southern Andes) seem to escape the glacial buzz-saw. This data gap is driven by the difficulty in constraining rates of glacial erosion over kyr-Myr timescales.Here, we use a novel thermochronometry technique, based on the Electron Spin Resonance (ESR) of quartz minerals, to constrain the timing of cirque basin formation adjacent to the Rhône valley, Switzerland. The Fully basin, near the town of Sion, sits above the ~1.5 km deep glacial Rhône valley, and is thought to have been incised by ~400 m during the Quaternary. Samples were collected in a transect across the basin, and complement samples previously investigated using ESR-thermochronometry from the Rhône valley (Wen et al., 2024).Forward modelling using a modified version of Pecube together with the kinetic parameters of existing ESR samples from the area (Wen et al., 2024) shows that ESR-thermochronometry data should be able to constrain the timing of cirque basin incision. This will provide the first dates and rates of glacial buzz-saw activity and will be contrasted with the timing of Rhône valley incision.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessPutting rates on the buzz-saw? Constraining the timing and rate of cirque valley incision, Rhône valley, Switzerland.
The observation that topography trends with snowline altitude despite large differences in tectonic uplift in various locations provides the foundation of the glacial buzz-saw hypothesis. However, despite numerous modelling studies, very few quantitative data are available that document the timing or rate of glacial topography formation. Consequently, challenges remain to explain why some localities (e.g. Alaska, southern Andes) seem to escape the glacial buzz-saw. This data gap is driven by the difficulty in constraining rates of glacial erosion over kyr-Myr timescales.Here, we use a novel thermochronometry technique, based on the Electron Spin Resonance (ESR) of quartz minerals, to constrain the timing of cirque basin formation adjacent to the Rhône valley, Switzerland. The Fully basin, near the town of Sion, sits above the ~1.5 km deep glacial Rhône valley, and is thought to have been incised by ~400 m during the Quaternary. Samples were collected in a transect across the basin, and complement samples previously investigated using ESR-thermochronometry from the Rhône valley (Wen et al., 2024).Forward modelling using a modified version of Pecube together with the kinetic parameters of existing ESR samples from the area (Wen et al., 2024) shows that ESR-thermochronometry data should be able to constrain the timing of cirque basin incision. This will provide the first dates and rates of glacial buzz-saw activity and will be contrasted with the timing of Rhône valley incision.
- Open Access
- 13 March 2026
- Published by Copernicus GmbH
GChron: 7 years and counting of Open Access Geochronology!
Geochronology is fundamental to many aspects of the Geosciences. Constraining timing and rates is essential for understanding geological, geomorphological and environmental processes. However, advances in geochronological methods and new applications are often hidden within the various Geoscience sub-disciplines which limits the opportunity for exchange innovations between geochronologists specialised in different techniques.Launched in 2019, GChron provides a platform for the discussion and dissemination of innovative geochronological research that cuts across disciplines, thereby facilitating better communication between experts in different geochronological techniques. It is hoped that this enhanced communication will foster innovation between techniques, providing clear benefits to the Geosciences.Since 2019, GChron’s submissions have stabilised at ~50 per year, attracting cutting-edge contributions from researchers worldwide.
- 13 March 2026
- Published by Copernicus GmbH
Open AccessGChron: 7 years and counting of Open Access Geochronology!
Geochronology is fundamental to many aspects of the Geosciences. Constraining timing and rates is essential for understanding geological, geomorphological and environmental processes. However, advances in geochronological methods and new applications are often hidden within the various Geoscience sub-disciplines which limits the opportunity for exchange innovations between geochronologists specialised in different techniques.Launched in 2019, GChron provides a platform for the discussion and dissemination of innovative geochronological research that cuts across disciplines, thereby facilitating better communication between experts in different geochronological techniques. It is hoped that this enhanced communication will foster innovation between techniques, providing clear benefits to the Geosciences.Since 2019, GChron’s submissions have stabilised at ~50 per year, attracting cutting-edge contributions from researchers worldwide.
- Open Access
- 4 March 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-19
Reply on CC2
Anomalous fading is a power law decay of trapped charge over time that is commonly observed in wide-bandgap semiconductors, leading to age underestimation in luminescence dating if unaccounted for. In this paper, we reappraise the mathematical foundations of luminescence signal correction and introduce two new closed-form analytical expressions for the two most commonly used age correction models, namely that of Huntley and Lamothe [Can. J. Earth Sci. 38, 1093–1106, 2001], and of Kars et al. [Radiat. Meas., 43, 786–790, 2008]. These expressions are amenable to straightforward uncertainty propagation, matching results from Monte-Carlo simulations at a fraction of the calculation cost. Additionally, we explore unorthodox combinations of signal fading and growth pathways, by coupling fading models to signal growth obeying general order kinetics, as well as the one-trap one-recombination center model.
- 4 March 2026
- Published by Copernicus GmbH
- Vol. 2025, 1-19
Open AccessReply on CC2
Anomalous fading is a power law decay of trapped charge over time that is commonly observed in wide-bandgap semiconductors, leading to age underestimation in luminescence dating if unaccounted for. In this paper, we reappraise the mathematical foundations of luminescence signal correction and introduce two new closed-form analytical expressions for the two most commonly used age correction models, namely that of Huntley and Lamothe [Can. J. Earth Sci. 38, 1093–1106, 2001], and of Kars et al. [Radiat. Meas., 43, 786–790, 2008]. These expressions are amenable to straightforward uncertainty propagation, matching results from Monte-Carlo simulations at a fraction of the calculation cost. Additionally, we explore unorthodox combinations of signal fading and growth pathways, by coupling fading models to signal growth obeying general order kinetics, as well as the one-trap one-recombination center model.