ABAna Raquel Benetti

Ana Raquel Benetti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ana Raquel Benetti has a total of 143 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of non-carious cervical restorations with different cavity configurations: a microscopy and OCT analysis

    by Ayla Macyelle De Oliveira Correia, Peter Hamilton Tomlins, Robert William Read, Taciana Marco Ferraz Caneppele, Eduardo Bresciani, Ana Raquel Benetti

    The aim of this in vitro study was to assess marginal and internal gap formation in simulated non-­carious cervical lesions (NCCLs) of different cavity configurations and restored with either bulk-fill or nanofilled resin composite, before and after thermocycling. NCCLs with 2.3 mm diameter and approximately 3.5 mm3 volume were prepared in 40 human molars in two cavity configurations (n = 20): saucer (1.3 mm depth) or wedge (1.9 mm depth) shape. The adhesive Clearfil SE Bond was used in all groups. These cavities were randomly divided according to the resin composite used (n = 10): Filtek Z350 XT or Filtek One Bulk Fill Restorative. The marginal and internal adaptation of the composite at cavity margins was assessed before and after thermal aging (TA) (5000 cycles between 5 and 55°C) using a plane light microscope and optical coherence tomography (OCT), respectively. The 3D images captured by OCT were analyzed by obtaining 16 B-scans per specimen using a custom-made script for software MATLAB R2019a, Update 3. Data were analyzed by two-way analysis of variance and paired t-tests (α = 0.05). Regarding the marginal gap, there was no statistically significant difference between the saucer and wedge cavity configurations, before or after TA, nor between cavities restored with bulk-fill or nanofilled composite (p > 0.05). Likewise, for the internal gap, no significant differences were found for the cavity configuration nor the resin composite (p > 0.05). Restorations placed in saucer or wedge cavity configurations showed similar marginal and internal adaptation, regardless of the type of resin composite, and gap formation was not aggravated by thermocycling.

  • Open Access

    Dynamics of hydrogen-rich species in light-cured dental materials

    by Maksym Golub, Jörg Pieper, Mark T.F. Telling, Tilo Seydel, Bernhard Frick, Ana R. Benetti, Heloisa N. Bordallo


  • Qualitative and quantitative assessment of tooth wear in young individuals

    by Maria Tummasdóttir Ellingsgaard, Floora Khesrawi, Anne Peutzfeldt, Nuno Vibe Hermann, Liselotte Sonnesen, Ana Raquel Benetti


  • Adhæsion til de hårde tandvæv med multimodale adhæsiver

    by Ana Raquel Benetti, Anne Peutzfeldt, Ankur Razdan

    English summary: Multimodal adhesives: Nor Tannlegeforen Tid. 2024; 134: 590-5. Multimodal or universal dental adhesives offer the clinician the possibility of choosing between etch-and-rinse or self-etching strategies. This literature review focuses on the performance of such bonding systems when bonding to dental hard tissues. The database PubMed was searched using the term “dental adhesive”. Among the selected articles priority was given to relevant meta-analyses and clinical studies from the past five years. Several laboratory and clinical studies support the use of multimodal adhesives for bonding to hard dental tissues. Multimodal dental adhesives perform best in enamel in combination with selective enamel etching. In dentine these adhesives’ performance is at large influenced by the functional monomer present in their formulation. Despite the well-documented overall performance of multimodal dental adhesives, their effectiveness is product-dependent regardless of the chosen bonding strategy.

  • Open Access

    Clinical and digital assessment of tooth wear

    by Zahra Al-Seelawi, Nuno V. Hermann, Anne Peutzfeldt, Sara Baram, Merete Bakke, Liselotte Sonnesen, Angeliki Tsakanikou, Christos Rahiotis, Ana R. Benetti

    The aim of this study was to compare the assessment of tooth wear performed on digital models with the one conducted at the clinical examination. Seventy-eight volunteers (29 males and 49 females, age range 20–30 years) with at least 24 teeth, normal oral function, and a neutral transverse relationship were examined. During the clinical examination, dental wear was registered according to the Basic Erosive Wear Examination (BEWE) index. Subsequently, the BEWE index was blindly applied by two examiners on digital models obtained from the volunteers. Data were analyzed using weighted Cohen’s kappa coefficient and correlation tests with a confidence interval of 95%. All volunteers showed signs of tooth wear. Anterior teeth showed increased severity of tooth wear than first molars. Early loss of tooth substance could be identified on the digital models, including in areas with challenging direct intraoral visual access. Approximately 50% of the scores based on clinical examination agreed with those based on examination of digital models (k = 0.543, p < 0.01). A moderate, positive correlation was observed between scores registered clinically and on digital models (Spearman's rho = 0.560, p < 0.001). Considering the rather low agreement between the clinical and digital scores, alternatives to using BEWE on digital models are needed.


  • Open Access

    Dimensional changes of endodontic sealers—An in vitro model simulating a clinical extrusion scenario during 18 months

    by Ankur Razdan, Ana R. Benetti, Azam Bakhshandeh, Tron A. Darvann, Lars Bjørndal

    Objectives: To examine the dimensional changes of endodontic sealers during 18 months using three‐dimensional (3D) surface scanning and subtraction radiography in a novel in vitro sealer‐extrusion model.Material and Methods: Fifty endodontically instrumented acrylic teeth were randomly allocated to five groups (n = 10) filled with Apexit Plus, AH Plus, BioRoot RCS, TubliSeal EWT, and gutta‐percha (control). Freshly mixed sealers were intentionally extruded during obturation. All teeth were immersed in a physiologic solution for up to 18 months. Blinded 3D surface scans (resolution: ~10 μm) and digital radiographs of the teeth were obtained at baseline (immediately after obturation); and then after 1 week, and at 1, 3, and 18 months. For blinded assessment of sealer dimensional change, 3D models and radiographs were superimposed using specific software. Volumetric differences, root mean square (RMS), and area change from subtraction radiography measured at each period within each sealer group were thereafter calculated. Repeated measures analyses were done with Bonferroni adjustment for multiple comparisons; standard errors, p values, and 95% confidence intervals (CI) were reported.Results: Analyses of the volumetric data confirmed significant, progressive material loss for Apexit Plus when compared to the other investigated sealers or the control group (p ≤ 0.02). Immersion period significantly influenced the volumetric dimensional changes of Apexit Plus already after 1 month (p < 0.01). For TubliSeal EW, the effect of the immersion period on the dimensional changes was noted after immersion for 3 months (p ≤ 0.02), while for BioRoot RCS this was evident only at 18 months (p < 0.01). Same trends were noted for the RMS data, whereas progressive dimensional changes using subtraction radiography only revealed significant changes for Apexit Plus (p = 0.01).Conclusions: The largest dimensional changes were shown by Apexit Plus, followed by Tubliseal EWT and BioRoot RCS. AH Plus remained stable throughout 18 months.


  • Open Access

    Optical coherence tomography systems for evaluation of marginal and internal fit of ceramic reconstructions

    by Hiba Al-Imam, Ana R. Benetti, Pete Tomlins, Klaus Gotfredsen

    To evaluate the marginal and internal fit of lithium disilicate and zirconia crowns using two optical coherence tomography (OCT) systems in order to estimate inter-system variations.Ten lithium dis...


  • Open Access

    Intraoral scanner featuring transillumination for proximal caries detection. An in vitro validation study on permanent posterior teeth

    by Stavroula Michou, Christoph Vannahme, Azam Bakhshandeh, Kim R. Ekstrand, Ana R. Benetti


  • Retentionscementer i en «nøddeskal»

    by Ana Benetti, Anne Peutzfeldt, Jan Tore Samuelsen, Klaus Gotfredsen

    English summary: Luting cements in a nutshell: Nor Tannlegeforen Tid. 2021; 131: 562–73 Choosing luting cements can be challenging given the constant development of resin cements and ceramic materials for indirect restorations. This review article gathers the most commonly used luting cements in current dental practice, focusing particularly on these cements’ composition and properties, which have an impact on their clinical indication. The article includes adhesive and non-adhesive luting cements for both final and temporary fixation of indirect restorations. Resin cements are categorized according to their polymerization reaction and the mechanism of adhesion to the hard dental tissues, while glass ionomer cements are divided into water-based and resin-reinforced versions. Among the non-adhesive cements included in this article is the well-known zinc phosphate cement used for final cementation, as well as zinc oxide-based cements for temporary cementation.

  • Detecting early erosive tooth wear using an intraoral scanner system

    by Stavroula Michou, Christoph Vannahme, Kim R. Ekstrand, Ana R. Benetti